SQUARE D SQR55141 USB Socket Outlet Charger Installation Guide

June 15, 2024
SQUARE D

**SQUARE D SQR55141 USB Socket Outlet Charger Installation Guide

**

Dual USB A/A Charger with 15 / 20 A Duplex Tamper Resistant Receptacle

Retain for future use


Introduction

The USB charger will charge most compatible electronic devices directly without an adapter and can replace a standard duplex receptacle. Tamper resistant shutters provide compliance with the 2011 NEC 406.11. USB protection includes overheating, overcurrent, and overvoltage. This device can beinstalled using back or side wiring.

Application

May be used in: cafeteria, offices, residential, restaurants, meeting rooms, airport lounges, laboratories, salons, hotels, schools, libraries, and workstations.

Specifications

Cat. No.| SQR55141
Input voltage| 125 Vac, max.
Output voltage| 5 Vdc 4.8 A (2.4 A max. for each port)
Operating temperature| 32–104° F (0–40°C)
USB charger protocol| BC 1.2,
Compliance| UL®

Compatibility

| Includes (but not limited to): iPad®, iPad mini®, iPhone®, IPod®, tablets, Android mobile phones, Blackberry®, Windows® Phone by HTC, Kindle®, Nook™ e-reader, GPS, Galaxy Tab™, Bluetooth® headsets, digital cameras, and other USB compatible products. If the devices combined power requirement exceed the power capacity of the USB ports, the charger will automatically protect the devices. /

Precautions

DANGER

  • HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
  • Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, NOM-029-STPS or CSA Z462 or local equivalent.
  • This equipment must only be installed and serviced by qualified electrical personnel.
  • This equipment can only be applied at altitudes below 6,562 ft. (2,000 m).
  • Firmly mount the equipment on concrete or other noncombustible surfaces only.
  • Shield/mask the equipment before renovation and to avoid contamination and degradation.
  • Shield/mask the front cover during installation to prevent damage.
  • Turn off all power supplying this equipment before working on or inside equipment.
  • Always use a properly rated voltage sensing device to confirm power is off.
  • This USB receptacle cannot be used if it is replacing a receptacle with top and bottom outlets controlled by a separate circuit breaker.
  • Replace all devices, doors and covers before turning on power to this equipment.

Failure to follow these instructions will result in death or serious injury.

WARNING: This product can expose you to chemicals including Carbon black which is known to the State of California to cause cancer, and and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

NOTICE

HAZARD OF EQUIPMENT DAMAGE

  • Before charging with the product, ensure the device battery complies with the battery charging specification.
  • Turn off the power supply when cleaning the product. Use a soft dry cloth to wipe dirt and contamination from the surface. Do NOT use corrosive chemicals.
  • Charging time depends on the supported charging protocol, power, battery capacity, charging line quality, and other factors.
  • Do not insert foreign objects (e.g., small metal wires, paper clips, liquids, etc.) into USB charger.
  • Heat will emit from the product surface while charging is in progress.
  • Reserve charging is not allowed.
  • Indoor use only

Installation

  1. Tum off all power supplying this equipment before working on or inside equipment.
  2.  Use a properly rated voltage sensing device to confirm power is off.
  3. Wire the charger according to the diagram in Figure 1.
    • Connect the LINE cable wires to the LINE terminals.
    • the white wire connects to the NEUTRAL terminal.
    • the black wire connects to the HOT terminal.
    • Connect the grounding wire (only if there is a grounding wire).
    • For a box with no grounding terminal: connect the LINE cable’s bare copper (green) wire directly to the grounding terminal on the receptacle (not shown).
    • For a box with a grounding terminal: (shown in Figure 1) connect a 6-inch bare copper (green) 12 or 14 AWG wire to the grounding terminal on the receptacle; also, connect a similar wire to the grounding terminal on the box. Connect the ends of these wires to the LINE cable’s bare copper (green) wire using a wire connector. If these wires are already in place, check the connections.

Figure 1 : Wiring Diagram

  1. Tighten the connections and ensure that no bare conductors are exposed.
  2. Insert the device into the standard outlet wall box. Attach the device to the wall box using the supplied screws.
  3. Install the appropriate wall plate. See Figure 2.
  4. Restore power and test system.

Figure 2 : Wall Plate Installation

**X Series

XD Series

15A – SQWVS55141

XD Series Multigene

15A – SQWVM55141

Only for installation of XD Series cover plate. /

NOTE:   = color code: WH (white), LA (light almond), BK (black), GY (gray)

FCC Statement

Federal Communication Commission Interference Statement
The equipment has been tested and found to comply with the limits for a class B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment uses, generates and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause
harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to  correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Supplier’s Declaration of Conformity
Product Name: USB RECEPTACLE
Model Number: SQR55141WH, SQR55141BK, SQR55141GY, SQR55141LA, SQR55241WH, SQR55241BK, SQR55241GY, SQR55241LA
Supplier’s Name: Schneider Electric
Supplier’s Address: 800 Federal Street, Andover, MA 01810, USA
Supplier’s Website : www.se.com/us

FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ISED Statement
This Class [B] digital apparatus complies with Canadian CAN ICES-3(B). This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Warranty Information

Schneider Electric warranties its products to be free of defects in materials and workmanship for a period of two (2) years. There are no obligations or liabilities on the part of Schneider Electric for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation.

References