Installation Dimension
Note: The configured templates can be taped on the door surface to assist you in drilling.
Packing List
Deadbolt Lock Parts
Door Handle Parts
How to Adjust Latch Length
-
Determine if the latch needs to be adjusted to 2-3/4″ (70mm).
-
To adjust, rotate the latch until it stops.
-
Stretch the head of the latch and reset the direction
-
Determine if the latch needs to be adjusted to 2-3/4″ (70mm)
-
To adjust, insert a screwdriver into the hole and push.
-
Operate in reverse to return 2-3/8″ (60mm).
Tools to Prepare
Drill | Pencil | 1(25mm) Drill Bit | Phillips Head Screwdriver | Hammer |
---|---|---|---|---|
Chisel | Tape Measure | 1/16(2mm) Drill Bill | 2-118″(54mm) Drill Hole Saw |
Drill Holes Into Door
- Measure and check that the diameter of the hole in the door is 2-1/8″ (54mm)
- Confirm that the backset is 2-3/8 or 2-3/4′(60mm or 70mm)
- Measure and check that the diameter of the side hole in the door is 1(25mm)
- Applicable Door Thickness: 1-3/8″ (35mm) to 1-3/4 (45mm)
Insert the latch. Ensure it is parallel to the face of the door. Mark the outline of the face plate and 2 holes. Then take out the latch.
Chisel 5/32″(4mm) deep along the outline to allow the face plate to be aligned with the door edge.
Insert the latch into the door.
Installation Steps – Right Hand Door Vision
Step 1. Install Deadbolt Latch
Step 2. Install Exterior Assembly
Note: Tail piece must be installed vertically
Step 3. Install Mounting Plate
Note: The Touch Keypad Assembly, Mounting Plate and Interior Assembly
should be installed vertically.
Step 4. Prepare Interior Assembly
Very important! Please set the knob direction according to your door opening
direction.
Step 5. Install Interior Assembly
Note: Ensure the wires are tightly connected. If the Touch Keypad Assembly does not respond after the batteries are installed, please reconnect the wires. Please do not overtighten the screws.
Step 6. Install AA Alkaline Batteries (Not Included)
Note: Do not use rechargeable batteries or non-alkaline batteries. Do not touch the keypad until the blue light turns off.
Step 7. Set the Unlock Direction I Door Direction Selection
Default setting is applicable to right open door. If you want to change to
left open, there are 2 ways: In factory setting mode, press
the “One-Key Unlock” on the interior assembly for 5 seconds. Please note that
this operation is invalid after entering your administrator information.
- Before the administrator is entered (factory setting mode), enter “666888# to switch the left and right direction quickly (invalid after the administrator is entered).
- After entering the administrator information, follow the instructions to operate in the Touch Keypad Assembly. (Refer to “Door Direction Selection” on page 18)
Step 8. Test Lock
Test locking. Tap to wake up the screen, and long press The latch pops up.
Test
unlocking. In the factory setting mode, any fingerprint, card, key and initial
password “123456 # ” can unlock the system.
Step 9. Install the Handle Latch Use two 3/4″ (20mm) screws to
tighten the latch into the door. Do not over-lighten.
Step 10. Install Exterior Handle
Step 11. Install Interior Handle
Step 12. Install Bottom Screw and Washer
Step 13. Install the Strike Plates
Note that each strike plate and box corresponds to a latch. Please refer to page 3 to confirm which latch they belong to.
Programming and Operating Instructions
- The”#” is the confirm key. After entering the password, please press”#” to confirm, such as “6666 + #”.
- The “” is the return key. To return to the previous operation or exit the setting mode, please press “”.
- Add Administrator1) After entering the setting mode, input a fingerprint, a password or a card, and the system will automatically assign the key sequence number.
- The first administrator key is the system default serial number “001” and cannot be deleted.
- 9 administrator keys can be entered (001-009). The number of valid digits of the password is 6-10.
- Enter fingerprint for 5 times, password twice and card once.
- After successful entry, you can continue to enter other “administrator keys”, or press the”*” key to return.
- Delete Administrator 1) Enter the number and press”#” key to confirm, for example, “002” + “#”.
- If you want to know the serial number of the unlock information, please directly enter to unlock, and the system will automatically broadcast its corresponding serial number.
- Administrator number range is 001-009, and the “001” administrator cannot delete it.
- After the administrators are deleted, the system will automatically replace
their numbers when they are entered again.
- Add User 1) After entering the setting mode, input a fingerprint, a password or a card, and the system will automatically assign the key sequence number, for example, “01 0”.
- The number of valid digits of the password is 6-10.
- 100 fingerprints, 100 passwords and 100 magnetic cards can be entered (010-310). Enter fingerprint for 5 times, password twice and card once.
- After successful entry, you can continue to enter other “user keys”, or press the”*” key to return.
- Delete User 1) Enter the number and press”#” key to confirm, for example, “010” + “#”.
- If you want to know the serial number of the unlock information, please directly enter to unlock, and the system will automatically broadcast its corresponding serial number.
- Common user number range is 010-310.
- After the common users are deleted, the system will automatically replace their numbers when they are entered again.
- Volume AdjustmentThe volume has four levels: 1-Low volume; 2-Medium volume; 3-High volume; 0-Mute. Select the corresponding number as needed.
- Unlock Mode Setting 1) “Single unlock” means that the door can be unlocked by any fingerprint, password or card that has been entered.
- “Combined unlock”(double verification mode) means that the door can only be unlocked by a combination of two different ways.
- The administrator is not limited by the double verification mode.
-
Language Selection “4” is Chinese, “2” is English, please select the corresponding number as needed.
-
Door Direction Selection 1. Press “1” for left open door, press “2” for right open door. The default is “right open”, please select the corresponding number as needed.
2. Before the administrator is entered (factory setting mode), enter “666888#” to switch the left and right direction quickly (invalid after the administrator is entered).
3. Before the administrator is entered (factory setting mode), press the “One-key unlock” key for 5S to quickly switch the left and right direction (invalid after the administrator is entered); -
Automatic locking 1) Please select the “Automatic Locking” function to close or open according to your own needs.
- After the “automatic locking” function is turned on, please select the delayed automatic locking time according to the corresponding number: (1) 5 seconds; (2)10 seconds; (3)15 seconds; (4 )30 seconds; (5)60 seconds.
- After the “automatic locking” function is turned on, the door lock will automatically close after unlocking.
- When the door lock is connected to the door magnet, the “automatic locking” function will be turned off by default.
- Restore factory setting 1) All data will be cleared after restoring factory settings, and the default direction is “right open”.
- Enter the number “888” + “#” to verify the administrator to quickly restore the factory settings.
- Press the factory setting button on the back of the back panel for 6S to force the factory settings to be restored.(Fig.1)
-
internal locking function/ Electronic Back Lock(Fig.2)
Push the Internal locking button for opening electronic back lock. If the exposed color is red, it means that the internal locking function is opened (in this case, only the administrator can unlock normally from outside, and common users cannot unlock), green means off. -
0ne-key unlock(Fig.3)
- Press the “One-key unlock” button on the back panel to unlock or lock.
- The door can be locked and unlocked through the mechanical manual knob.
- Anti-peeping Password
You can enter random numbers before and after the correct password to confuse the judgment.
Q&A
Important!
- Please confirm whether the lock is suitable for your door thickness before installation.
- Before installation, pay attention to adjust the installation angle of the spindle and the knob direction of the Interior Assembly. If these two parts are installed incorrectly, you will find that the lock cannot work properly.
- The latches and interior handle must be installed horizontally, and the lock bodies and exterior handle must be installed vertically. Otherwise, latches will not work properly.
- For installation steps, please refer to the video we posted on Amazon’s product page. If you have any questions, please feel free to contact us.
Product Technical Parameters
No. | Function | Content | Details |
---|---|---|---|
1 | Unlock mode | Fingerprint + password + IC card + key | |
2 | Number of administrators | 9 people | 001-009 |
3 | Number of users | 300 people | 010-310 |
4 | Fingerprint | 100 pcs | Fingerprints need to be entered 5 times repeatedly |
(please enter from multiple angles)
5| Password| 100 sets| Password needs to be entered twice, press “#” key to
confirm (6-10 digits, the passwords must be the same twice)
6| Magnetic card| 100 pcs| Enter once
7| Virtual password
length| -16 pcs| This product has virtual anti-peeping password. Random
numbers can be entered before and after the correct password.
8| Low voltage alarm| 4.7V ±0.2V| When the voltage is below 4.7V, the red
indicator lamp will flash continuously for 5 times, with voice prompt “Low
battery, please replace in time”, you can continue to unlock; when the
voltage is below 4.5V, the red indicator lamp will flash continuously for 5
times, and the door cannot be unlocked. Emergency charging is supported.
9| Quiescent current| 60uA|
10| Dynamic current| >250mA|
11| Power voltage| 6V| Please select high quality 5# alkaline 1.5V battery.
---|---|---|---
12| Emergency power supply| 5VDC| At the bottom of the Touch Keypad Assembly.
USB type-C Port.
13| Working temperature| -25°C —70°C|
14| Working humidity| 20c/0-90c/or|
15| Audio navigation| English/ Chinese voice| Wake up the keypad screen, input
“8899#” to verify the administrator and quickly switch between Chinese and
English
16| Error alarm| Support| After wrong fingerprint/ password / card/ key is
continuously entered 10 times, the door will be locked for 1 minute.
17| Internal locking function| Electronic back lock| Push the internal locking
button to open/ close electronic back lock. (Only the administrator can unlock
normally after back lock, common users cannot unlock.
18| Quick lock| Outdoor quick lock| Long press on the panel to lock
immediately
20| Quick sleep| “#” key for quick sleep| Long press the “#” key to quickly
exit the system and sleep