DC MONT DC300LFP-12V Lithium Iron Phosphate Battery User Manual

June 15, 2024
DC MONT

DC MONT DC300LFP-12V Lithium Iron Phosphate Battery

DC-MONT-DC300LFP-12V-Lithium-Iron-Phosphate-Battery-
PRO PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION AND MAINTENANCE, FOLLOW ALL PROVIDED WARNING & CAUTION, AND KEEP IT FOR FUTURE REFERENCE.

Product Specifications

  • Model No.: DC135LFP-12V
  • Dimensions: 330172215mm
  • Nominal Capacity: 135Ah
  • Energy: 1,728Wh
  • Cycle Life: 2,000 Cycles
  • Nominal Voltage: 12V
  • Recommended Charge Voltage: 50A
  • Max. Charge Current: 100A
  • Max. Continuous Discharge Current: 200A
  • Max. Pulse Discharge Current(5S): 200A
  • Max. Modules in Series/Parallel: N/A
  • Standard Operation Temperature: N/A
  • Charge Temperature: N/A
  • Storage Temperature: N/A

Product Usage Instructions

Battery Maintenance & Storage
Please follow the below instructions for battery maintenance and storage:

  • Read the user manual carefully before operation and maintenance.
  • Follow all provided warnings and cautions.
  • Keep the user manual for future reference.

Troubleshooting
If you encounter any problems during operation, please refer to the following troubleshooting instructions:

Problem: Overcharge
Suggested Solution: Disconnect your battery from charging for recovery.

Problem: Over-current / Short Circuit Protection
Suggested Solution: Disconnect your battery and activate it with a LiFePO4 battery charger if it recovers abnormally.

Problem: Over-discharge
Suggested Solution: Output will be automatically cut off by the built-in BMS. You are recommended to activate it with a LiFePO4 battery charger.

Problem: Temperature beyond normal ranges
Suggested Solution: The battery will be automatically disconnected from the load by the built-in BMS. Allow it to cool down or warm up to room temperatures, and activate it with a LiFePO4 battery charger if it recovers abnormally. Note: It is highly likely that your battery is damaged if it cannot be activated by the charger.

FAQ

  • Q: What should I do if my battery cannot be activated by the charger?
    A: If your battery cannot be activated by the charger, it is highly likely that the battery is damaged. Please contact us for professional help.

WARNING & CAUTION

  • This battery should be installed only by qualified personnel following safe electrical work practices.
  • ALWAYS use batteries under the same brand with equal voltage.
  • It is not recommended to mix batteries of a different age.
  • You are supposed to both connect 4 batteries in series and connect 2 batteries in parallel.
  • Fully charge it before series or parallel connection.
  • ALWAYS wear eye protection, gloves and mask when working with the battery.
  • Also remove any metal / conductive jewelry.
  • This battery should be installed on flat and level floor.
  • And there should be NO flammable or explosive materials with minimal dust and dirt.
  • NEVER touch the exposed electrolyte, and NEVER open or dismantle the lithium iron phosphate battery if the battery casing is damaged.
  • Flush with plenty of clean water and seek medical assistance in case your skin or eyes contact with it.
  • Use caution to eliminate the risk of dropping a metal tool on the battery.
  • It could spark or short circuit the battery and cause an explosion.
  • NEVER open or disassemble the battery.
  • DO NOT allow water to enter the battery.
  • NEVER smoke or allow a heat source, spark or flame near the battery.
  • Use a type D, foam or CO2 fire extinguisher in case of fire.
  • Avoid mechanical shock and DO NOT pierce, hammer or step on the battery.
  • NEVER solder battery terminals.
  • NEVER allow wires or other metal objects to short-circuit the terminals.
  • This battery should be charged with a charger whose parameters meet requirements of its technical specifications.
  • If charged after the lithium iron phosphate battery was discharged below the discharge cut-off voltage, or when it is damaged, this LiFePO4 battery can release a harmful mixture of gasses.
  • Make sure the battery is COMPLETELY dry before use or reactivation to prevent a safety hazard.
  • Regularly check if there is any damaged cable or loose connection.

BATTERY MAINTENANCE & STORAGE

  • The battery should be stored in a well ventilated and dry area in temperatures between -10℃ and 45℃.
  • Avoid sharp impacts or extreme pressure.
  • Avoid condensation caused by temperature changes during storage.
  • Failure to do so can lead to corrosion, rust and internal battery failure.
  • Regularly check if the battery is clean, dry and free of corrosion.
  • Make sure all equipment is connected and there is no potential parasitic loads which may discharge your battery.
  • Charge your battery at least once every 3 months to prevent over-discharge.
  • Fully charge your battery before it is to be used.
  • Use a damp cloth or non-metallic brush to clean the battery.
  • Make sure there is no charging load or source before cleaning.
  • Make sure that your battery is COMPLETELY dry before reactivating.

PARAMETERS

MODEL NO. DC135LFP-12V DC220LFP-12V DC300LFP-12V
Dimensions 330172215mm 532207215mm 522267220mm
Nominal Capacity 135Ah 220Ah 300Ah
Energy 1,728Wh 2,816Wh 3,840Wh
Cycle life

2,000 Cycles
Nominal Voltage| 12.8V
Recommended Charge Voltage| 14.8V
Max. Charge Current| 50A| 75A| 75A
Max. Continuous Discharge Current| 100A| 150A| 150A
Max. Pulse Discharge Current(≤5S)| 200A| 300A| 300A
Max. Modules in Series/Parallel| 4S & 2P
Standard Operation Temperature| 25±5°C
Charge Temperature| 0~45°C
Storage Temperature| 10~45°C

TROUBLESHOOTING

Please refer to the following instructions or contact us for professional help in case of any problem during operation.

PROBLEM SUGGESTED SOLUTION
Overcharge Disconnect your battery from charging for recovery.
Over-current /short circuit protection Disconnect your battery, and activate

it with LiFePO4 battery charger if it recovers abnormally.
Over-discharge| Output will be automatically cut off by built-in BMS. You are recommended to activate it with LiFePO4 battery charger.
Temperature beyond normal ranges| The battery will be automatically disconnected from the load by built-in BMS. Allow it to cool down or warm up to room temperatures, and activate it with LiFePO4 battery charger if it recovers abnormally.

Note: It is highly likely that your battery is damaged if it cannot be activated by the charger.

WARRANTY

What is Covered?
DC MONT warrants that this LiFePO4 battery will operate free from defects in material and workmanship under normal use during the Warranty Period of 2 Years. This Limited Warranty is to the original purchaser of the product and is not transferable to any other person or entity. Within the Warranty Period, DC MONT will either replace the product or provide you with a refund at our discretion provided that the fault is found to have been caused by a design or manufacturing defect under normal use and maintenance.

What is not Covered?
Each of the product has a built-in battery management system (BMS) designed to cut off power to prevent damage to the cells or electronics if it senses any of the following conditions: over-charge or over-discharge, over voltage, under voltage, over current while charging or discharging and under or over temperature. The user is responsible to manage battery use so the BMS protection system is not operating as a regulator controlled by the above mentioned protective functions. Damage caused by repetitive BMS protection cycling is considered abuse and is not covered.

This Limited Warranty does not cover product failure related to damages caused by abuse or negligence, tampering, non-adherence to DC MONT guidelines or from any of the following: loose terminal bolts, corroded hardware, failure to properly install and connect the battery, failure to properly charge and maintain the battery, breakage or damage from collision, fire, water, freezing, damage from extreme heat or cold, improper storage, reverse polarity connection, short circuit of the battery terminals.
This Limited Warranty does not cover repair, maintenance, and adjustment to the product required for reasons of neglect, misuse, accident, modification, improper environment (including lack of proper temperature or humidity), unusual physical or electrical stress or interference, failure of lightning, fire, or acts of God.

Warranty Disclaimer
DC MONT makes no representations or warranties regarding the product other than those expressly stated in this Limited Warranty. The foregoing Limited Warranties are exclusive and in lieu of all other express and implied warranties whatsoever. DC MONT specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. To the maximum extent permitted by applicable law, DC MONT shall not be liable for any damages whatsoever (including without limitation, special, incidental, consequential, or indirect damages for personal injury, loss of business profits, loss of business information, or any other pecuniary loss) arising out of the use of or inability to use this product. In any case, DC MONT’s entire liability under any provision of this warranty shall be limited to the amount actually paid by you for the product. Because some jurisdictions do not allow the exclusion of limitation of liability for consequential or incidental damages, the above limitation may not apply to you.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals