xikentech HD060 AC120V 15Amp Automatic Transfer Switch User Guide
- June 15, 2024
- xikentech
Table of Contents
HD060 AC120V 15Amp Automatic Transfer Switch
HCDC®
AC120V 15Amp Automatic Transfer Switch Model: HD060
IMPORTANT !
- THIS MODULE OPERATES ON A HAZARDOUS VOLTAGE !
- DISCONNECT AC POWER DURING INSTALLATION !
- Installation must be done according to local regulations and standards. If any doubt, consult a licensed technician.
- This module is not suited for portable applications.
FEATURES:
- HCDC HD060 Automatic transfer switch, an easy to mount 15Amp inline transfer relay provides switching between AC INPUT 2 (Utility or Shore Power) and AC INPUT 1 (Inverter or Generator) AC source. When AC INPUT 2 is powered, the load power will be switched to AC INPUT 2. When AC INPUT 2 is powered off, the load power will be switched to AC INPUT 1.
- Operating voltage AC 90 to 135V 50/60Hz. Maximum current 15 Amp.
- Transfer time less than 30mS (0.03 second). For most smart devices or computers, the switching action of 30mS time will not affect their normal operation.
- Internal four high power SPST relays switch design, effectively avoid the problem of DPDT relay high inductive load arcing. Live and Neutral wire are switched at the same time. The Ground wires of the two inputs and output are connected together internally and will not follow the switch on and off.
- IP68 Waterproof high level enclosure, suitable for indoor or outdoor use. Flame retardant rating V1. Case material: PC (Polycarbonate). Seal material: Silicone rubber. External screw: 304 stainless steel.
- AC INPUT 1 cable: Length 19 inch (0.5 meter), US standard NEMA 5-15P 3 prong plug. AC INPUT 2 and AC OUTPUT cables: Length 19 inch (0.5 meter), 14AWG (2.08 square millimeter) x 3 cores.
SPECIFICATIONS:
- Input or Output Voltage: ………………………… AC 90 – 135V 50/60Hz.
- Maximum Current: ……………………………….. 15 Amp.
- Transfer Time: …………………………………….. 30 millisecond.
- Input / Output Cable Length: …………………… 19 inch (0.5 meter).
- Enclosure Waterproof Rating: …………………. IP68.
INPUT / OUTPUT SWITCH STATUS:
AC INPUT 1
(Inverter or Generator)| AC INPUT 2
(Utility or Shore Power)| AC OUTPUT
---|---|---
Powered| Powered|
Powered from AC INPUT 2
Powered| No Powered|
Powered from AC INPUT 1
No Powered| Powered|
Powered from AC INPUT 2
No Powered| No Powered|
Output No Powered
CABLE CONNECTS:
AC INPUT 1: US standard NEMA 5-15P 3 prong plug. Recommended connect Inverter or Generator.
AC INPUT 2: 14AWG (2.08 square millimeter) x 3 cores. Recommended connect Utility or Shore Power.
AC OUTPUT: Power output, connect to Load.
AC INPUT 2 / AC OUTPUT Cables connect color: L – Black (AC Live Wire)
N – White (AC Neutral Wire)
G – Green (Ground Wire)
DANGER !!!
- Do not open the housing in order to avoid the risk of electroshocks.
- This module operates on a dangerous AC voltage !
- All repairs should be executed by qualified technicians.
SAFETY INSTRUCTIONS !!!
- Do not attempt to disassemble the unit as it does not contain any parts that are to be serviced by the user. (Tampering voids warranty)
- Do not touch unused terminals when the module is connected to the AC power.
- Handle the module gently and carefully. Dropping it can damage the circuit board and case.
- Never exceed the protection limit values indicated in the specifications.
- As safety requirement vary, please check with your local authorities.
- Disconnect the module from the AC power before connecting new devices.
- Wipe the device with a dry and clean cloth. Do not use detergents or other liquids that may damage the housing.
- Keep the device away from children.
- Facilitate the operation of the device by familiarizing yourself with its adjustments and indications.
- Xiken-Tech and HCDC modules are not suitable for use or as part of life support systems, or systems that might create hazardous situations of kind.
DIMENSIONS:
References
Read User Manual Online (PDF format)