DESCO TB-3073 Multi Mount Monitor
Description
The Desco Multi-Mount Monitor is a single workstation continuous monitor. It
continuously monitors the path-to-ground integrity of one operator and one ESD
worksurface. Mounting tabs make it suitable to install in workbench or
equipment settings. Connect the 19653 Remote Alarm accessory to the Multi-
Mount Monitor, and place it in the operator’s field of view for increased
alarm visibility. The Multi-Mount Monitor is designed with Wave Distortion
Technology which provides stable continuous monitoring of the path-to-ground
and presence of 1 megohm resistance of an operator’s wrist strap. Audio and
visual alarms activate (in less than 50 milliseconds) when the operator
unintentionally disconnects from the monitor or the wrist strap connection
points are intermittent. The Multi-Mount Monitor also monitors for a
worksurface path-to-ground of less than 10 megohms. All Multi-Mount Monitors
are calibrated to NIST standards.
Wave Distortion Technology is the Most Reliable Technology for the Continuous
Monitoring of Single-Wire (Conductor) Wrist Straps “Wave Distortion” or vector
impedance works by applying a continuous test voltage of 1.2 volts peak-to-
peak at 1 to 2 microamperes (0.000002 amperes) to the wrist strap that is
connected to the continuous or constant monitor. The test voltage creates a
square wave that the monitor circuit compares to established patterns. By
monitoring the “distortions”, or shape of the square wave, Wave Distortion
Technology determines if the monitored circuit is complete – the operator is
in the circuit and the total equivalent DC resistance is within
specifications. Wave Distortion Technology produces a very fast alarm time
(<50 milliseconds) and minimal false alarms. ANSI/ESD S20.20 section 7.3
states “Compliance verification records shall be established and maintained to
provide evidence of conformity to the technical requirements.” Per ANSI/ESD
S1.1 Annex A.3 Daily (wrist strap system) testing may be omitted if constant
monitoring used.” Per ESD Handbook ESD TR 20.20 section 5.3.2.4.4 “Typical
Test programs recommend that wrist straps that are used daily should be tested
daily. However, if the products that are being produced are of such value that
knowledge of a continuous, reliable ground is needed, and then continuous
monitoring should be considered or even required.”
The Multi-Mount Monitor and its accessories are available as the following item numbers:
Item | Description |
---|---|
19651 | Multi-Mount Monitor, North American Power Adapter |
19652 | Multi-Mount Monitor, Universal Power Adapter |
19653 | Remote Alarm |
19258| Power Adapter, 100-240VAC Input, 24VDC 150mA Output, IEC
Inlet
19260| Power Adapter, 100-240VAC Input, 24VDC 150mA Output,
North America Plug
19264| Power Adapter Extension Cord, 3′
98221| Wave Distortion Monitor Verification Tester
Packaging
19651 Multi-Mount Monitor, North America
- 1 Multi-Mount Monitor
- 1 Mat Monitor Cord (White)
- 1 Countersunk Washer
- 1 Flat Head Screw, 6-32 x 1/4″
- 2 Pan-Head Screws, #6 x 3/8″
- 1 Dual Lock Fastener Set, 2″ Length
- 1 Power Adapter, 24VDC, North America Plug
North American power adapter included with the 19651 Multi-Mount Monitor
19652 Multi-Mount Monitor, Universal Power Adapter
- 1 Multi-Mount Monitor
- 1 Mat Monitor Cord (White)
- 1 Countersunk Washer
- 1 Flat Head Screw, 6-32 x 1/4″
- 2 Pan-Head Screws, #6 x 3/8″
- 1 Dual Lock Fastener Set, 2″ Length
- 1 10mm Interchangeable Park Snap
- 1 10mm Operator Jack Adapter
- 1 Power Adapter, 24VDC, IEC Inlet
Universal power adapter included with the 19652 Multi-Mount Monitor
NOTE: The power cord must be purchased separately if ordering the 19652
Multi-Mount Monitor.
The power cords are available as the following item numbers:
Item | Plug Type |
---|
50545| Europe
50546| United Kingdom
19653 Remote Alarm
- 1 Remote Alarm
- 1 Remote Cable, 7′ Length
- 2 Pan-Head Screws, #6 x 3/8″
- 1 Dual Lock Fastener Set, 1″ Length
Desco 19653 Remote Alarm
Features and Components
Multi-Mount Monitor
Multi-Mount Monitor features and components
- A. Mat Monitor Switch: Use a probe to access the mini slide switch. Slide the switch to the right to enable the mat monitor circuit. Slide the switch to the left to disable the mat monitor circuit. This switch is enabled as default.
- B. Buzzer Volume Adjustment: Turn the trimpot clockwise to increase the buzzer volume. Turn the trimpot counter-clockwise to decrease the buzzer volume.
- C. Monitored Operator Jack: Insert the single-wire wrist cord here to monitor the operator’s connection to ground.
- D. Operator LEDs: Illuminates green when the operator is properly grounded. Illuminates solid red and audible alarm sounds when the operator is not properly grounded.
- E. Mat LEDs: Illuminates green when the worksurface is properly grounded. Illuminates red and audible alarm sounds when the worksurface is not properly grounded.
- F. Park Snap: Allows the operator to disconnect (and park) a wrist strap when leaving the workstation, without creating a false alarm. Touch the park snap and the monitor’s audible alarm will disable for approximately 10 seconds. Use this time to disconnect the wrist cord from the wristband, and attach it to the park snap or remove the banana plug from the jack. Upon returning to the workstation and disconnecting the wrist cord from the park snap, the operator has approximately 10 seconds to reconnect the wrist cord to a worn wristband before activating the alarm.
- G. Mat Monitor Screw Terminal: Verifies that the worksurface’s path-to-ground is <10 megohms. Connect the white mat monitor cord here.
- H. Power Jack: Connect the included 24VDC power adapter here.
- I. Remote Alarm Jack: Connects to the 19653 Remote Alarm accessory.
Remote Alarm
Remote Alarm features and components
- A. Multi-Mount Monitor Jack: Connects to the Multi-Mount Monitor.
- B. Operator LEDs: Illuminates green when the operator is properly grounded. Illuminates solid red and audible alarm sounds when the operator is not properly grounded.
- C. Mat LEDs: Illuminates green when the worksurface is properly grounded. Illuminates red and audible alarm sounds when the worksurface is not properly grounded.
Installation
Installing the Multi-Mount Monitor and Remote Alarm accessory
-
Remove the Multi-Mount Monitor from the carton, and inspect for damage.
-
Locate an appropriate AC outlet near the
Multi-Mount Monitor, and test it for proper wiring and grounding prior to use. The Desco AC Outlet Analyzer or similar test equipment may be used to verify the outlet’s functionality. Use item number 98132 for 120VAC North American outlets and item number 98131 for 220VAC UK outlets. -
Determine the mounting location of the Multi-Mount Monitor. Its LEDs should be visible to the operator. Secure the Multi-Mount Monitor to a surface using its mounting tabs and the included pan-head screws or dual lock fasteners.
-
Secure the ring termination of the white mat monitor cord to the mat monitor screw terminal on the side of the Multi-Mount Monitor. Ensure that the mat monitor switch is enabled if using this monitored circuit.
-
Connect the mat monitor cord from the side of the Multi-Mount Monitor to a grounded worksurface mat. Use the included countersunk washer and flat head screw to secure the cord to the grounded mat.
-
Connect the power adapter to the power jack located on the side of the Multi-Mount Monitor, and plug the power supply into the tested AC outlet.
Remote Alarm
- Determine the mounting location of the optional 19653 Remote Alarm. Locate it within reach of the included remote cable. Its LEDs should be visible to the operator. Secure the Remote Alarm to a surface using its mounting tabs and the included pan-head screws or dual lock fasteners.
- Connect the Remote Alarm to the Multi-Mount Monitor using the remote cable.
-
Mounting hole locations on the Multi-Mount Monitor (all dimensions are in inches)
-
Mounting hole locations on the Remote Alarm (all dimensions are in inches)
10mm Park Snap and 10mm Operator Jack Adapter
The 19652 Multi-Mount Monitor includes an interchangeable 10mm park snap and
10mm banana jack adapter for operators who use wrist cords with 10mm
terminations. Use the park snaps’ knurled rims to unscrew the 4mm park snap
from the monitor and install the 10mm park snap to the monitor. Plug the 10mm
operator jack adapter into the monitor’s operator jack.
- Changing the park snap on the 19652 Multi-Mount Monitor
Operation
- Fit the wristband snugly onto the wrist.
- Snap the wrist cord to the wristband.
- Plug the wrist cord into the operator jack. The green operator LED will illuminate. This indicates that the operator is properly grounded.
- If this does not happen, examine the wrist cord for continuity or damage and the wristband to ensure that it fits securely. If you have dry skin, apply an approved dissipative hand lotion such as Menda Reztore® ESD Hand Lotion.
- When leaving the workstation, first touch the monitor’s park snap. The monitor’s audible alarm will disable for approximately 10 seconds. Use this time to disconnect the wrist cord from the wristband and attach it to the park snap without sounding a false alarm.
- Upon returning to the workstation and disconnecting the wrist cord from the park snap, the monitor will provide approximately 10 seconds for the operator to reconnect the wrist cord to a worn wristband before sounding the monitor’s alarm.
Using the Multi-Mount Monitor and Remote Alarm in a workbench setting
Using the Multi-Mount Monitor at a machine station
Calibration
Frequency of recalibration should be based on the critical nature of those ESD
sensitive items handled and the risk of failure for the ESD protective
equipment and materials. In general, Desco recommends that calibration be
performed annually. Use the Desco 98221 Wave Distortion Monitor Verification
Tester to perform periodic verification (once every 6-12 months) of the Multi-
Mount Monitor. The verification tester can be used to check the test limits of
the Multi-Mount Monitor without removing it from the workstation.
See TB-3074 for more information.
Desco 98221 Wave Distortion Monitor Verification Tester
Specifications
Input Voltage and Frequency (External Adapter)| AC/DC Power Adapter
Power Input: 100-240VAC, 50/60 Hz Power Output: 24VDC @ 150mA Cable Length: 5
ft. (1.5 m)
---|---
Operating Temperature| 50 to 95°F (10 to 35°C)
Environmental Requirements| Indoor use only at altitudes less than 6500 ft. (2
km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to
50% @ 85°F (30°C)
Dimensions (Monitor)| 3.87″ L x 2.09″ W x .90″ H
(98 mm x 53 mm x 23 mm)
Dimensions (Remote Alarm)| 1.78″ L x 1.08″ W x .79″ H
(45 mm x 27 mm x 20 mm)
Weight (Monitor)| 0.14 lbs. (0.06 kg)
Weight (Remote Alarm)| 0.02 lbs. (0.01 kg)
Operator Test Range*| 500 kilohms to 10 megohms impedance
Worksurface Test Limit**| 10 megohms (±20%)
Operator Test Voltage| 1.2V peak-to-peak @ 1.2µA, open circuit
Worksurface Test Voltage| 5 to 7.5V, open circuit
Alarm Response Time| <50 ms
Certifications| CE
Country of Origin| United States of America
- This cannot be verified with standard DC test equipment. The continuous monitor is an impedance sensing device, and the limits are determined by the magnitude and angle of the impedance.
- The worksurface mat must have a conductive layer such as Dual Layer Rubber or Dissipative 3-Layer Vinyl with conductive buried layers. Desco workstation monitors are not recommended for use with homogeneous matting.
- ANSI/ESD S20.20 requires the use of a surface resistance meter for periodic verification of a worksurface’s resistance-to-ground (Rtg). Constant monitors may not be used as a substitute for this requirement.
Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request Instructions See the Desco Warranty – Desco.com/Limited- Warranty.aspx
- DESCO WEST – 3651 Walnut Avenue, Chino, CA 91710 • 909-627-8178
- DESCO EAST – One Colgate Way, Canton, MA 02021-1407 • 781-821-8370
- Website: Desco.com
- © 2023 DESCO INDUSTRIES INC Employee Owned
References
- Desco - Limited Warranty
- Desco - 19258 100-240VAC, 24VDC 150 MA Out, IEC Inlet Adapter
- Desco - 19260 Adapter, North American Plug, 100-240VAC In, 24VDC 150 MA Out
- Desco - 19652 Multi-Mount Continuous Monitor with Universal Plug
- Desco - 19653 Remote Alarm for Multi-Mount Monitor
- Desco - 98221 Wave Distortion Monitor Verification Tester