Itowa MATCBPEN Remote Control COMBIPLUS User Manual
- June 14, 2024
- Itowa
Table of Contents
- MATCBPEN Remote Control COMBIPLUS
- Product Information
- Specifications
- Introduction
- GCFI Version
- Product Usage Instructions
- General Terms for Correct and Safe Use of the Radio Remote
- Keyboard Locking Process
- Remote Control
- Battery Charger
- Installation of the Receiver
- Start-Up
- Maintenance of the Charger
- Battery Charging
- Operation Mode
- Automatic Frequency Change Procedure
- Manual Frequency Change Procedure
- Checking the Selected Channel
- Channel Assignment Table
- Summary of Functionality of the Remote Control LEDs
- LED Information During Change of Frequency
- Information About Frequency Channel Through LED
- Keyboard Lock
- Summary to Change the Frequency Band (Not Valid for GCFI
- Summary to Change Manually the Frequency Band (Not Valid for
- Summary to Change the Transmission Time
- Packaging
- 1. Can I use the remote control without fully charging the
- 2. How do I lock the keyboard to prevent accidental button
- 3. What are the LED indicators on the remote control for?
- 4. How do I charge the batteries of the remote control?
- 5. Can I manually change the working frequency on the GCFI
- 6. What should I do if I encounter an incident or issue with
MATCBPEN Remote Control COMBIPLUS
Product Information
Specifications
-
Model: Remote Control COMBIPLUS EN
-
Model Number: MATCBPEN – Rev.4- 04/2024
-
Frequencies:
-
UHF Band: 433,050 – 434,775 MHz (UN 30 and 32 of the
C.N.A,F.) -
UHF Band: 868,000 – 870,000 MHz (UN 39 of the C.N.A.F.)
-
-
Signal Type: FM frequency modulation and FFSK encoding
Introduction
The COMBIPLUS remote control is designed for wireless control of
electromechanically operated machinery. It utilizes advanced
technology and microprocessors to ensure safe and reliable
operation. The system employs FM frequency modulation and FFSK
encoding for radio signals.
The remote control is equipped with various security mechanisms
to prevent unwanted operations and self-detect anomalies. The
receiver operates in the UHF band at specified frequencies
according to telecommunications regulations.
GCFI Version
The GCFI (Intelligent Frequency Change Management) version of
the remote control features an intelligent system that
automatically and randomly changes to vacant frequencies. This
helps avoid interference and ensures uninterrupted operation.
Product Usage Instructions
General Terms for Correct and Safe Use of the Radio Remote
Control
Before using the remote control, ensure that the batteries are
fully charged. It is important to follow the correct and safe usage
guidelines for optimal performance and safety.
Keyboard Locking Process
The remote control has a keyboard locking process to prevent
accidental button presses. This feature ensures that operations are
not triggered unintentionally.
Description of the Set
Remote Control
The remote control is the main component of the set. It allows
you to control the electromechanical machinery wirelessly. The
remote control has various maneuvers and LED indicators for status
information.
Description of Maneuvers
The remote control provides different maneuvers for controlling
the machinery. These maneuvers are designed to perform specific
operations and movements.
LED Information
The remote control features LED indicators that provide
information about the status and operation of the machinery. These
LEDs help in monitoring the remote control’s activity.
Battery Charger
The set includes a battery charger for charging the remote
control’s batteries. The charger ensures that the batteries are
fully charged before use.
Battery Charging Process
To charge the batteries, follow the specified battery charging
process. This process ensures efficient charging and extends
battery life.
Installation and Start-Up
Installation of the Receiver
Proper installation of the receiver is crucial for effective
communication between the remote control and electromechanical
machinery. Follow the installation instructions provided to ensure
a secure and reliable connection.
Start-Up
After installation, perform the start-up procedure to initialize
the remote control and establish communication with the machinery.
This procedure involves setting the transmission time and checking
the battery status.
Setting the Transmission Time
Set the desired transmission time for communication between the
remote control and machinery. This time determines how long each
command is transmitted.
Battery Status
Check the battery status to ensure that the remote control has
sufficient power for operation. Monitoring the battery status helps
prevent unexpected power failures during use.
Maintenance of the Remote Control
Regular maintenance of the remote control ensures optimal
performance and extends its lifespan. Follow the maintenance
guidelines provided to keep the remote control in good
condition.
Maintenance of the Charger
The charger also requires maintenance to ensure efficient
charging and prolong its lifespan. Follow the specified maintenance
procedures for the charger.
Battery Charging
Proper battery charging is essential for long-lasting
performance. Follow the recommended battery charging guidelines to
ensure optimal battery life and functionality.
Display of Equipment Code
The remote control features a display that shows the equipment
code. This code helps identify and differentiate between multiple
remote controls and machinery.
Display of the Working Channel
The working channel display on the remote control indicates the
current channel being used for communication with the machinery.
This information helps ensure correct channel selection and avoids
interference.
Changing the Working Frequency (Not Valid for GCFI
Versions)
Note: This section is not applicable to GCFI versions of the
remote control.
Operation Mode
Determine the desired operation mode for changing the working
frequency. The operation mode determines whether the frequency
change procedure is performed automatically or manually.
Automatic Frequency Change Procedure
If using the automatic frequency change procedure, follow the
specified steps to initiate the frequency change. This procedure
ensures a smooth transition to a new frequency without interrupting
operation.
Manual Frequency Change Procedure
If using the manual frequency change procedure, follow the
provided steps to manually select a new frequency. This procedure
allows for precise frequency selection based on specific
requirements.
Checking the Selected Channel
After changing the working frequency, verify the selected
channel to ensure proper communication with the machinery. This
step helps confirm that the desired frequency has been successfully
set.
Channel Assignment Table
Refer to the channel assignment table for a comprehensive
overview of available channels and their corresponding frequencies.
This table assists in selecting the appropriate channel for
communication.
Possible Incidents and Solutions
In case of any incidents or issues with the remote control,
refer to the provided solutions. This section helps troubleshoot
common problems and provides guidance for resolving them.
Quick Display Guide
Summary of Functionality of the Remote Control LEDs
Refer to the quick display guide for a summary of the remote
control’s LED indicators and their corresponding functionalities.
This guide helps understand the meaning of different LED patterns
and states.
LED Information During Change of Frequency
During the frequency change procedure, the LED indicators
provide specific information about the frequency change process.
Understanding these LED indications ensures proper execution of the
frequency change.
Information About Frequency Channel Through LED
The LED indicators also provide information about the current
frequency channel being used for communication. This information
helps ensure accurate frequency channel selection.
Keyboard Lock
Learn how to activate and deactivate the keyboard lock feature
to prevent accidental button presses. The keyboard lock ensures
that operations are not triggered unintentionally.
Summary to Change the Frequency Band (Not Valid for GCFI
Versions)
Note: This section is not applicable to GCFI versions of the
remote control.
Summary to Change Manually the Frequency Band (Not Valid for
GCFI Versions)
Note: This section is not applicable to GCFI versions of the
remote control.
Summary to Change the Transmission Time
Refer to the summary guide for changing the transmission time.
This guide provides step-by-step instructions for adjusting the
transmission time according to specific requirements.
Recyclability
Packaging
Properly dispose of the packaging material according to the
specified recyclability guidelines. This helps minimize
environmental impact and supports sustainable practices.
FAQ (Frequently Asked Questions)
1. Can I use the remote control without fully charging the
batteries?
No, it is recommended to fully charge the batteries before using
the remote control for the first time. This ensures optimal
performance and avoids unexpected power failures during
operation.
2. How do I lock the keyboard to prevent accidental button
presses?
To lock the keyboard, follow the specified keyboard locking
process provided in the user manual. This feature prevents
unintended operations and ensures safety during use.
3. What are the LED indicators on the remote control for?
The LED indicators on the remote control provide information
about the status and operation of the machinery. They help monitor
the remote control’s activity and ensure proper functionality.
4. How do I charge the batteries of the remote control?
Refer to the battery charging process outlined in the user
manual. Follow the specified steps and guidelines to ensure
efficient charging and extended battery life.
5. Can I manually change the working frequency on the GCFI
version?
No, the GCFI version of the remote control automatically changes
to vacant frequencies to avoid interference. Manual frequency
change is not applicable to the GCFI version.
6. What should I do if I encounter an incident or issue with
the remote control?
If you experience any incidents or issues, refer to the possible
incidents and solutions section of the user manual. Follow the
provided solutions to troubleshoot and resolve common problems.
User Manual
Remote Control COMBIPLUS EN
MATCBPEN – Rev.4- 04/2024
REMOTE CONTROL COMBIPLUS
USER MANUAL
PLEASE FULLY CHARGE THE BATTERIES BEFORE USING THE EQUIPMENT FOR THE
FIRST TIME
IT’S FORBIDDEN TO FULLY OR PARTIALLY REPRODUCE THIS MANUAL WITHOUT THE PRIOR
WRITTEN AUTHORISATION FROM ITOWA.
IN THE EVENT OF INFRINGEMENT, ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT
DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW. ITOWA RESERVES THE RIGHT
TO MODIFY THIS MANUAL WITHOUT PRIOR NOTIFICATION.
2
REMOTE CONTROL COMBIPLUS
USER MANUAL
INDEX:
1. INTRODUCTION
5
1.1. GCFI VERSION
5
2. GENERAL TERMS FOR THE CORRECT AND SAFE USE OF THE RADIO REMOTE CONTROL 6
2.1. KEYBOARD LOCKING PROCESS
6
3. DESCRIPTION OF THE SET
7
3.1. REMOTE CONTROL
7
3.1.1. DESCRIPTION OF MANOEUVRES
7
3.1.2. LED INFORMATION
8
3.2. BATTERY CHARGER
8
3.2.1. BATTERY CHARGING PROCESS
9
4. TECHNICAL SPECIFICATIONS
10
4.1. TRANSMITTER
10
4.2. BATTERY CHARGER
10
5. INSTALLATION AND START-UP
11
5.1. INSTALLATION OF THE RECEIVER
11
5.2. START-UP
11
5.2.1. SETTING THE TRANSMISSION TIME
11
5.2.2. BATTERY STATUS
12
6. MAINTENANCE OF THE REMOTE CONTROL
13
6.1. MAINTENANCE OF THE CHARGER
14
6.2. BATTERY CHARGING
14
7. DISPLAY OF THE EQUIPMENT CODE
15
8. DISPLAY OF THE WORKING CHANNEL
16
9. CHANGING THE WORKING FREQUENCY (NOT VALID FOR GCFI VERSIONS)
17
9.1. OPERATION MODE
17
9.2. AUTOMATIC FREQUENCY CHANGE PROCEDURE
18
9.3. MANUAL FREQUENCY CHANGE PROCEDURE
19
9.4. CHECKING THE SELECTED CHANNEL
21
9.5. CHANNEL ASSIGNMENT TABLE
22
10. POSSIBLE INCIDENTS AND SOLUTIONS
23
11. QUICK DISPLAY GUIDE
25
11.1. SUMMARY OF FUNCTIONALITY OF THE REMOTE CONTROL LEDS
25
11.2. LED INFORMATION DURING CHANGE OF FREQUENCY
25
11.3. INFORMATION ABOUT FREQUENCY CHANNEL THROUGH LED
26
11.4. KEYBOARD LOCK
26
3
REMOTE CONTROL COMBIPLUS
USER MANUAL
11.5. SUMMARY TO CHANGE THE FREQUENCY BAND (NOT VALID FOR GCFI VERSIONS) 26
11.6. SUMMARY TO CHANGE MANUALLY THE FREQUENCY BAND (NOT VALID FOR GCFI
VERSIONS)
27
27
11.7. SUMMARY TO CHANGE THE TRANSMISSION TIME
28
12. RECYCLABILITY
29
12.1. PACKAGING
29
4
REMOTE CONTROL COMBIPLUS
USER MANUAL
1. INTRODUCTION
The manual you have in your hands is a guide for the correct use of the
COMBIPLUS remote control.
This unit, together with the associated receiver, has been specifically
designed for the wireless remote control of electromechanically operated
machinery.
The radio signals used employ FM frequency modulation and FFSK encoding. The
most advanced technology and the latest generation microprocessors have been
used in electronic design. This allows total safety in the use of the radio
remote control.
To avoid unwanted operations, the system is provided with various security
mechanisms that will be described in the next chapters. Any self-detection of
anomalies blocks the execution of the operations..
The receiver works in the UHF band at frequencies between 433,050 and 434,775
MHz (UN 30 and 32 of the C.N.A,F.), or between 868,000 and 870,000 MHz (UN 39
of the C.N.A.F.) as prescribed in the telecommunications regulations I-ETS 300
220.
1.1. GCFI VERSION
The GCFI (Intelligent Frequency Change Management) version provides the
equipment with an intelligent system enabling it to change to vacant
frequencies automatically and at random, thereby avoiding interferences which
could cause continuous downtimes during operation.
ATTENTION!: EVERYTHING RELATED IN THIS MANUAL TO THE CHANGE OF FREQUENCY AND
THE WORKING CHANNEL, IS NOT VALID FOR THE GCFI VERSION.
5
REMOTE CONTROL COMBIPLUS
USER MANUAL
2. GENERAL TERMS FOR THE CORRECT AND SAFE USE OF THE RADIO REMOTE CONTROL
The user, in order to have the maximum security in the handling of the remote
control, must follow the rules described in this manual.
The operator of the remote control, when he has to perform any command of the
device, must be located in a place where he can visualize at all times the
manoeuvre he is performing. If it’s impossible to do so, he must be located in
a place where he can see the maximum possible manoeuvre, and in the hidden
places, an assistant is required. Never perform a manoeuvre that may have an
uncontrolled part.
Do not leave the transmitter of the remote control on the floor or on top of
metal blocks, in case you have to do it, activate the emergency stop (STOP
BUTTON) of the transmitter and put the key / switch in its OFF position or
lock the keyboard in if enabled (see section 2.1 – Keypad Lock Procedure).
When the operator of the remote control ends his working day or has to leave
the remote control, he must activate the emergency stop (STOP BUTTON) and
place the battery in the charger for its recharging.
2.1. KEYBOARD LOCKING PROCESS
Optionally, the device can have a keyboard lock/unlock system using a key sequence.
The remote control keyboard is locked by pressing the start button 5 times in less than 3 seconds, with the STOP BUTTON pressed, which is indicated by the simultaneous lighting up of the LED and the LED .
To unlock the keyboard, press the start button again 5 times in less than 3 seconds with the STOP BUTTON pressed. However, to confirm the unlocking, the two LEDs above blink three times.
Please note that if the start button is pressed when the keyboard is locked, el LED flash alternately.
and the LED
6
REMOTE CONTROL COMBIPLUS
USER MANUAL
3. DESCRIPTION OF THE SET
· Remote control · Batteries · Charger
3.1. REMOTE CONTROL
It’s a waterproof joystick panel (IP65) made of highly resistant plastic
material. On the front side you can find the buttons and joysticks for
manoeuvres, power switch, emergency stop button and indicative LEDs, and on
the back side there is the housing for the interchangeable batteries.
The transmitter consists of three parts: buttons, control circuit and UHF
transmitter/transceiver.
PUSHBUTTONS SWITCHES
COMMUTATORS
MODULATOR
TRANSMITTER
For the GCFI model, the diagram would be as follows:
PUSHBUTTONS SWITCHES
COMMUTATORS
CONTROL
TRANSCEIVER
The commands coming from the buttons are acquired by the microprocessor, which
is in charge of elaborating the FFSK signal by adding the direction and
control codes and injecting them into the UHF transmitter. The transmitter
incorporates the signal of that command into the carrier frequency, which,
previously filtered, will be emitted by the antenna. In the case of the models
that incorporate the GCFI version, the transmitter becomes a transceiver in
order to establish a two-way communication with the receiver.
3.1.1. DESCRIPTION OF MANOEUVRES There are different control configurations
adapted to each application. A document with the specific configuration for
each application is supplied with the equipment. Optionally, this range of
remote controls can incorporate the following functions:
· Tandem / Trolley pre-selection: the transmitter can communicate with two
different receivers. · Pitch & Catch: operating mode in which several
transmitters (between 2 and 4) and 1 receiver
are associated. · Master/Slave: operating mode in which 2 transmitters are
associated with 2 receivers. · IR safety: this infrared (IR) safety blocking
system makes it possible to limit the communication
range to a certain area, disabling manoeuvres (Range Control) or preventing
start-up (Start Control). · Option with Data Feedback: the transmitter and
receiver use bidirectional communication, so the transmitter can receive
information from the receiver and display it by means of the LEDs. NOTE: In
case of incorporating any of these options, an annexed manual is provided.
7
REMOTE CONTROL COMBIPLUS
USER MANUAL
3.1.2. LED INFORMATION The various operating and fault diagnosis states are
indicated by 2 LEDs:
LED
Indication
Radio function status. On indicates that the remote control is transmitting.
GCFI versions: flashing rapidly or temporarily off indicates correct
communication. If it remains on when a manoeuvre is activated, it indicates
that there is no communication with the receiver.
Battery status. You can see the indication details of this LED in section
5.2.2. of this manual.
NOTE: You will find details of the information provided by the LEDs in section
10.
On some COMBIPLUS models, additional LEDs may be available to provide further
information. The function of these LEDs can be found in the accompanying
documentation that will be delivered with the special equipment.
3.2. BATTERY CHARGER
The charger is for indoor use. The charger allows a fast and safe charging of
batteries. The batteries supplied are Ni-MH and the charger is designed to
optimise their charge and life span. It’s capable of detecting defective,
short-circuited or overheated batteries and can recover discharged batteries
after a long period.
Power LED
Charging LED
Overview of the battery charger
8
REMOTE CONTROL COMBIPLUS
USER MANUAL
3.2.1. BATTERY CHARGING PROCESS The charger has two indicator LED, one for
power, which indicates that the appliance is connected to the power supply,
and another for charging, which indicates that charging is in progress. When
inserting the battery, the charger checks the charge level and can perform two
actions based on it:
· If the charge level is low, a precharge is performed (LED flashing)
· A constant charging is performed for approx. 20 minutes (LED on fixed).
After this time, the charger verifies the state of the battery and adapts the
load to each case. When the charging process ends, the LED turns off. A full
charge takes approximately 4 and a half hour. Charging should be done at a
temperature between -10 and 50 ºC. Before using the remote control for the
first time, make a full charge of the batteries.
9
REMOTE CONTROL COMBIPLUS
USER MANUAL
4. TECHNICAL SPECIFICATIONS
4.1. TRANSMITTER
Number of orders:
Probability of wrong manoeuvre: Hamming distance: Programmable code: Order
response time: Active emergency time: Passive emergency time: Range of action:
Frequency bands (I-ETS 300 220): Temperature range: Canalization: Modulation:
Codification: Emission power: Frequency stability: Harmonic attenuation:
Consumption in emission:
Consumption in stand-by: Power:
Autonomy:
Material:
Dimensions:
Water tightness:
Up to 40 digitals (optional up to 56) Up to 7 analogue (optional up to 8)
10-18
6 Till 16777216
<50 ms
<50 ms
1600 ms
100 meters 433,050 to 434,775 MHz 868,000 to 870,000 MHz From -20ºC to +70ºC
25 kHz
FM
FFSK
10 mW P.R.A.
+ 2.5 ppm (-30ºC to +70ºC)
70 dB < 80 mA < 50 mA (GCFI) < 800 µA
Removable battery Ni-MH, 7.2 V; 1,5 A/h 18 hours + 10 minutes back up 25 hours
- 10 minutes back up (GCFI) PA 6-6, 15 % Fiberglass COMBIPLUS 295 x 175 x 190 mm COMBIPLUSXL 370 x 180 x 200 mm IP 65
4.2. BATTERY CHARGER
Power supply: Consumption: Max. Power: Charging intensity: Charging time:
Protection: Charger dimensions: Approx. weight:
100 – 240 Vac 3,6 VA 6 VA 400 mA 2,5 hours IP30 88 x 153 x 48 mm 0,2 kg + 0,35 kg (power supply)
10
REMOTE CONTROL COMBIPLUS
USER MANUAL
5. INSTALLATION AND START-UP
5.1. INSTALLATION OF THE RECEIVER
The details of the receiver installation can be found in the corresponding
manual. It is indispensable that you consult the mentioned manual before
starting up.
5.2. START-UP
Once the receiver has been installed, by activating the main switch on the
machine, the LEDs on the front of the receiver will light up to verify that it
is working correctly.
Insert a charged battery into the remote control and unlock the EMERGENCY STOP
BUTTON. When the START button is pressed, the remote control will start
working by activating the stop and start relays, and the general contactor
will be locked. The LED on the remote control will be activated, indicating
that the remote control is in work mode. From this moment on, pressing any
button will activate the corresponding manoeuvre. The selected manoeuvre will
remain active as long as the button is pressed.
To keep the radio channel free and prevent the operator from accidentally
leaving the machine running when not in use, the remote control has been
fitted with an automatic stop system. If no action is taken, this system acts
after 180 seconds (configurable), sending a stop sequence to the receiver,
which will cause the machine to stop.
When the machine stops, the frequency channel on which the device is working
is displayed through pulses on the and LEDs of the receiver. The display
begins with the tens pulses by the LED and continues with the units by the
LED. In case that the value of tens or units will be zero, the display of this
LED will be skipped. Further details of this channel display are given in
Chapter 8.
5.2.1. SETTING THE TRANSMISSION TIME The configuration of the automatic stop time (default 180 seconds) is done from the pushbutton panel, and this time can be changed between three values as follows:
-
Lock the STOP button and turn the on/off switch or key to the OFF position.
ATTENTION!: REMEMBER THAT LOCKING THE E- STOP BUTTON IS THE SAME AS STOPPING THE REMOTE CONTROL, THAT MEANS, TO DEACTIVATE IMMEDIATELY ANY RELAY OPERATED IN THE RECEIVER. -
Operate any of the directions of the joystick marked as TIME in the following figure and, keeping it pressed, turn the on/off switch or key to the ON position.
11
REMOTE CONTROL COMBIPLUS
USER MANUAL
ON/OFF
TIME
EMERGENCY STOP
TIME
Fig. 5-1. Buttons used to change the emission time.
START HORN
-
Wait between 3 and 5 seconds approximately and unlock the EMERGENCY-STOP Button.
-
Release the TIME button and y reactivate it.
-
The and
LEDs will flash simultaneously one to three times indicating the time that has been
programmed, which can be :
· Mode 1: 180 seconds (one flash).
· Mode 2: 330 seconds (two flashes).
· Mode 3: continuous emission (three flashes).
Repeat the sequence successively to change from one mode to another
cyclically. To activate the transmitter again, press the START button.
5.2.2. BATTERY STATUS The transmitter is provided with an indicator LED of the
battery status. When the remote control detects that the battery is at a low
level of charge (reserve status), the LED will start to flash and the horn
manoeuvre will be activated intermittently: After approximately 10 minutes,
the transmitter turns off, and sends a stop sequence to the receiver, and the
LED lights on fix (battery empty). When the battery is in reserve, it is
recommended to charge the battery.
ATTENTION!: WHEN THE BATTERY IS IN RESERVE, IT IS NOT POSSIBLE TO PERFORM THE
FOLLOWING FUNCTIONS: MODE FREQUENCY CHANGE, FREQUENCY CHANGE, KEYBOARD LOCK
AND CHANGE THE AUTOMATIC DISCONNECTION TIME.
12
REMOTE CONTROL COMBIPLUS
USER MANUAL
6. MAINTENANCE OF THE REMOTE CONTROL
The equipment you have purchased is manufactured using top quality materials
to ensure perfect working order and operation of the remote control. Similarly
to all machinery and equipment, the remote control requires minimum basic
maintenance tasks that should be performed.
ATTENTION!: IF ANY ANOMALY IS DETECTED IN THE OPERATION OF THE EQUIPMENT, IT MUST BE PUT OUT OF SERVICE IMMEDIATELY.
In order to increase the life of your equipment as much as possible, and avoid
unnecessary repair costs, we recommend that you carefully follow the following
conservation and maintenance tips:
· Avoiding unnecessary hits on the equipment.
· Use the attachment accessories, shoulder strap, properly and adjust it so
that the use of the equipment is comfortable and safe.
· Although the equipment has a high degree of water tightness (IP65), it
shouldn’t be totally or partially submerged and shouldn’t be left in places
where it could flood if it rains.
· The pushbuttons of the set are made of an elastic material to give them
elasticity, texture and water tightness, so you must take special care to
avoid touching them with sharp objects that could damage the structure of the
button. When the button is worn-out or damaged it must be replaced
immediately.
· It’s also advisable not to leave the remote unnecessarily exposed to the
sun’s rays.
· Check that the battery holder contacts are free of dirt and rust and that
they exert the spring return force correctly.
ATTENTION!: BEFORE ANY MANIPULATION PROCEED TO DEACTIVATE THE MAIN SWITCH OF THE MACHINE.
Generally, it’s advisable to carry out a complete revision of the water
tightness devices that protect both the receiver and the transmitter from bad
weather conditions every now and then. It’s advisable that this revision is
done by a Technical Assistance Service accredited by ITOWA, since a bad
waterproofing can cause irreparable damage to the equipment.
In the case of the remote control, pay particular attention to the joints and
rubber protections of the different drives, replacing them immediately if they
have been cut or suffered other damages.
ATTENTION!: ORIGINAL SPARE PARTS SHOULD BE USED FOR ANY REPAIRS, AND THE SAFETY FEATURES AS WELL AS THOSE OF THE UHF TRANSMITTER AND RECEIVER, SHOULD NEVER BE ALTERED.
To test the function of the active safety, simply actuate the EMERGENCY STOP
BUTTON on the transmitter while it is running. The general contactor must fall
down immediately.
To check the operation of the passive safety, disconnect the power or remove
the battery from the transmitter. The general contactor should drop after
within a maximum of 1.6 seconds.
13
REMOTE CONTROL COMBIPLUS
USER MANUAL
6.1. MAINTENANCE OF THE CHARGER
The following parts will be checked: · Contacts (which must be free of dirt
and rust) · The correct display and indication of the LEDs.
If you have any questions or doubts, please do not hesitate to contact our
Technical Assistance Service or any of our authorized technicians.
6.2. BATTERY CHARGING
The batteries included in the ITOWA equipment have no memory effect, which
means that they can be put into charge without being completely discharged.
For this reason, and in order to extend their useful life, it’s recommended to
use one battery every half working day.
14
REMOTE CONTROL COMBIPLUS
USER MANUAL
7. DISPLAY OF THE EQUIPMENT CODE
In case you need to know the equipment’s code, the receiver allows you to
display it. You can consult the manual of the receiver associated to this
remote control to see the procedure that has to be followed, in order to see
this code.
15
REMOTE CONTROL COMBIPLUS
USER MANUAL
8. DISPLAY OF THE WORKING CHANNEL
It is important to know the frequency channel in which you are working to make a frequency change or to detect possible interferences from other equipment on the communication between the transmitter and receiver.
To know the frequency channel of the transmitter, please follow the below steps:
-
Activate the EMERGENCY STOP button.
-
Remove the battery or, if you have a key / switch put it on the OFF position.
-
Activate the START button and, keeping it pressed, move the switch/key to the ON position.
-
The frequency channel is then displayed by the LEDs and as follows:
· First, the LED not flash.
will flash as many times as tens have the frequency channel. In case it is zero it will
· Then, the LED will not flash.
will flash as many times as the frequency channel has units. In case it is zero, it
· Once tens and units have been displayed, the transmitter can be started.
16
REMOTE CONTROL COMBIPLUS
USER MANUAL
9. CHANGING THE WORKING FREQUENCY (NOT VALID FOR GCFI VERSIONS)
ATTENTION!: THE WORKING FREQUENCY SHOULD ONLY BE CARRIED OUT BY AUTHORISED STAFF.
ATTENTION!: IF THE BATTERY HAS BEEN PUT ON STANDBY DUE TO LOW CHARGE, IT WILL
NOT BE POSSIBLE TO SELECT A FREQUENCY CHANGE MODE OR CHANGE THE FREQUENCY.
9.1. OPERATION MODE
The system can operate in three modes:
· Mode 1: change of frequency disabled. · Mode 2: change of frequency in
manual mode. · Mode 3: change of frequency in automatic mode.
ATTENTION!: THE EQUIPMENT IS DELIVERED WITH THE CHANGE OF FREQUENCY IN
AUTOMATIC MODE.
Changing the operation mode: 1) Unlock the STOP BUTTON and turn the on/off
switch or key to the OFF position. Press START and the joystick in UNITS (see
Fig. 9.1.) at the same time and, keeping them pressed, turn the key/switch to
the ON position. The LEDs and will flash simultaneously from one to three
times indicating the mode of operation that has been programmed, which may be:
· Mode 1: change of frequency disabled (one flash).
· Mode 2: change of frequency in manual mode (two flashes).
· Mode 3: change of frequency in automatic mode (three flashes).
ON/OFF
TENS
EMERGENCY STOP
START UNITS
Fig. 9-1. Buttons used to set the frequency change mode.
17
REMOTE CONTROL COMBIPLUS
USER MANUAL
- Without releasing the START button, each time the unit joystick is operated it will change the mode of operation successively from mode 1 (frequency change disabled) to mode 2 (frequency change in manual mode), to mode 3 (frequency change in automatic mode), from mode 3 again to mode 1 and so on.
The system works in the UHF band in the frequencies between 433.050 MHz and
434.775 MHz, or between 868.000 MHz and 870.000 MHz, depending on the model
purchased, and complies with the requirements of the telecommunications and
safety regulations I-ETS 300-220 (see section 9.5. CHANNEL ASSIGNMENT TABLE).
9.2. AUTOMATIC FREQUENCY CHANGE PROCEDURE
ATTENTION!: TO PERFORM AN AUTOMATIC FREQUENCY CHANGE, THE AUTOMATIC FREQUENCY
CHANGE MODE MUST FIRST BE SELECTED (MODE 3, SEE SECTION 9.1). To change the
working frequency automatically, proceed as follows: 1) If you are working
with the remote control, as a safety measure, remove the transmitter battery
to disconnect the equipment.
2) Insert a charged battery. It is not possible to change frequency with a
discharged battery.
3) Make sure the receiver is ready for operating. The leds will display the
following message, indicating that there is voltage and that it does not
detect the channel occupied by another system:
Receiver ready
ICON
INDICATION LED off with rapid flashing on. LED on steady
ATTENTION!: PLACE THE TRANSMITTER AS CLOSE AS POSSIBLE TO THE RECEIVER.
-
If the STOP BUTTON is locked (pressed) it must be unlocked (released).
-
Press the START button (see section 9.1) to start the equipment and, keeping it pressed, lock the STOP button. The device automatically selects a new frequency and the new channel is sent to the receiver. The transmitter and the receiver will indicate the new frequency channel with the LEDs.
To indicate this information on the transmitter, the and
LEDs are used. First there are as
many flashes of the LED as the number of tens to be displayed, and then as many flashes of the
LED as the number of units to be displayed. A very similar sequence occurs at the receiver: the
LED indicates the tens and the LED the units.
18
REMOTE CONTROL COMBIPLUS
USER MANUAL
Transmitter
Tens Units
Tens Units
Receiver
If the frequency change has been made correctly the indicators and
will stop flashing and the
equipment is ready to work. If the frequency change is not successful, repeat the process until the
receiver picks up a free channel.
After changing the working channel, in order to continue operating with the radio control, release the emergency stops button (STOP BUTTON) and press the START push button. In the receiver, the S1 indicator will activate, indicating that the stop and start relays are activated. As a consequence, remote control is operating correctly and all manoeuvres can be performed.
9.3. MANUAL FREQUENCY CHANGE PROCEDURE
ATTENTION!: TO PERFORM A MANUAL FREQUENCY CHANGE, THE MANUAL FREQUENCY CHANGE MODE MUST FIRST BE SELECTED (MODE 2, SEE SECTION 9.1).
To change the operating frequency in manual mode, proceed as follows: 1) If
you are working with the remote control, as a safety measure, remove the
transmitter battery to disconnect the equipment.
2) Insert a charged battery. It is not possible to change frequency with a
discharged battery.
3) Check that the receiver is ready to work. The LEDs on the receiver will
light up as follows, indicating that there is voltage and it does not detect
the channel occupied by another system:
Receiver ready
ICON
INDICATION LED off with rapid flashing on. LED on steady
ATTENTION!: PLACE THE TRANSMITTER AS CLOSE AS POSSIBLE TO THE RECEIVER.
- If the STOP BUTTON is locked (pressed) it must be unlocked (released). 19
REMOTE CONTROL COMBIPLUS
USER MANUAL
- Press the START button (1) to start the equipment and, keeping it pressed,
lock the STOP button. The illuminated indicators and from the transmitter will
flash alternately. The receiver is waiting for the new working channel.
From this moment on, you will have one minute to introduce the new working channel. After this time, the device will exit the programming mode and will maintain the old channel, displaying the working channel through the LEDs on both the transmitter and the receiver, as described in the previous section. - Enter the channel number, e.g. 27, by pressing the joystick or by moving the corresponding remote control to TENS twice and to UNITS seven times. Press VALIDATE.
- The selected channel is sent to the receiver, which will indicate the new channel via the LEDs, just like the transmitter.
Tens Units
Transmitter
Tens Units
Receiver
The frequency change has been successfully completed and the indicators and
will stop flashing. After the change of the working channel, in order to
continue operating with the radio control, it is necessary to unlock the
emergency STOP BUTTON and act on the START button. The indicator S1 on the
receiver, if fitted, will light up permanently, indicating that the stop and
start relays are activated and, consequently, the general contactor of the
machine should be reset, and any manoeuvre can now be performed.
NOTE: If the frequency change has been started in manual mode and the validate
button is pressed without first entering the units or tens, the remote control
unit will automatically select the first channel in the working band (see
channel assignment table in section 9.5).
ON/OFF TENS
EMERGENCY STOP
Manoeuvre for START Manoeuvre for VALIDATE
UNITS
Fig. 9-2 Buttons used to manually change the frequency.
1See fig 9-2 for description of related buttons
20
REMOTE CONTROL COMBIPLUS
USER MANUAL
9.4. CHECKING THE SELECTED CHANNEL
After changing the frequency, it is advisable to check that the selected
channel is not already occupied. Carry out the following operations:
- Turn off the transmitter by pressing the STOP BUTTON.
- If the channel is busy, the LED on the receiver will remain on, indicating
that the channel is busy.
In this case, it is necessary to change the new transmitting channel as many times as necessary until we find a free channel. This will avoid abnormalities in the functioning of the machine.
21
REMOTE CONTROL COMBIPLUS
USER MANUAL
9.5. CHANNEL ASSIGNMENT TABLE
Country Scope Outside the European Union Internal the European Union Outside the European Union Internal the European Union
RADIO CHANNELS
Channels
Channels from 1 to 70
Channels from 41 to 70
Channels from 1 to 81
Channels from 1 to 24 Channels from 30 to 48 Channels from 58 to 68 Channels
from 70 to 81
Frecuency Band 433-434 MHz Frecuency Band 433-434 MHz Frecuency Band 868-870 MHz Frecuency Band 868-870 MHz Frecuency Band
22
REMOTE CONTROL COMBIPLUS
USER MANUAL
10. POSSIBLE INCIDENTS AND SOLUTIONS 1
INCIDENT
STATUS
SOLUTION
Check that the battery is correctly inserted.
The equipment doesn’t start.
Neither of the transmitter
If a key or switch is fitted, check that it is in the
indicators and light up. ON position.
Check the charge status of the battery or replace it directly with a charged one.
Only the emitter LED up.
lights
If when lifting the emergency stop and pressing start the LED flashes, see the next point. If the battery LED does not flash, there is a fault in the radio module.
If the LED lights up and the Data memory failure, contact the Technical
LED flashes.
Assistance Service.
Only the LED
of the
transmitter lights up.
The battery is empty and must be replaced with a charged one.
The LED on the transmitter switches on, but in the receiver
the LED is off (not applicable to GCFI versions).
Check that the channel of the transmitter and the receiver are the same.
Keep the transmitter’s start button activated until the receiver is switched
on (max. 1 minute). Do this as close as possible to the receiver.
Both LEDS and transmitter flash.
of the Transmitter with blocked keyboard. To unlock it, follow the steps in section 2.1.
The LED flashes.
on the transmitter If there is an active channel, check that all the actuators of the transmitter are in rest position.
One of the LEDs in the transmitter makes two rapid flashes and a pause.
A contact of the STOP BUTTON has broken down, notify the Technical Assistance Service.
None of the indicators on the receiver light up.
Check that the power supply of the receiver is correct and that it’s connected correctly.
The LED S2 on the receiver is on or flashing and the stop relays are not interlocked.
Failure in serial drivers or stop relays, contact the Technical Assistance Service.
The remote control starts but not the machine.
The receiver is connected to the machine but is still not working.
The fuses of the stop relays are blown. They must be replaced with new fuses of the same value.
1 Information on receptors is included to facilitate the diagnosis of the problem. 23
REMOTE CONTROL COMBIPLUS
USER MANUAL
INCIDENT
STATUS
Transmitter and receiver start but the machine does not work.
The receiver is connected to the machine but it still does not work.
SOLUTION
Check fuses in receiver. If there is any melted, it must be replaced by a new
one of the same value (see value in the technical specifications section of
the receiver).
Check the connection of the receiver hose to the electrical panel of the
machine through the corresponding connectors.
Put the cable / cab keypad instead of the remote control and if this does not
work either, the problem is on the machine.
After changing the working channel the machine does not work.
LED (LINK) of receiver is on, but it does not work.
The receiver keeps LED (LINK) on being the transmitter in repose.
Keep the start button of transmitter pressed until the receiver starts
(maximum 1 minute). Make it closest to the receiver.
There are interferences on the new channel. It should be changed to another
and, if it does not find the new channel, it must be kept pressed the start
button on the transmitter (maximum 1 minute). Make it closest to the receiver.
The transmitter does not allow a frequency change.
Indicators and not flash alternately.
do
Check battery charge status. Check the configured frequency change mode.
Wrong introduction of the working channel in a frequency change.
Undesired working channel entered.
Repeat the entire process with the desired working channel.
The remote control has little range and the machine stops, but it allows rearming.
Antenna disconnected, broken or in bad condition.
Although the transmitter is disconnected locking the ESTOP button, the
receiver continues with the LED (LINK) on.
Replace the antenna or notify the Technical Assistance Service.
There is interference from another device. You have to change the working
channel, following the steps in the section “Frequency change” in the
transmitter manual.
No response to the travelling manoeuvre.
ON/OFF button Traveling not activated.
Press the Travelling button.
Randomly the receiver is stopped or some relays are not activated, but the receiver is still running.
LED (PWR) of the receiver stays on but performs a quick pulse.
LED (PWR) of the receiver stays on but performs two quick pulses.
Receiver power supply is below 50% of nominal. Receiver power supply is below 45% of nominal.
ATTENTION!: ORIGINAL SPARE PARTS SHOULD BE USED FOR ANY REPAIR AND SAFETY
FEATURES SHOULD NEVER BE ALTERED.
24
REMOTE CONTROL COMBIPLUS
USER MANUAL
11. QUICK DISPLAY GUIDE
11.1. SUMMARY OF FUNCTIONALITY OF THE REMOTE CONTROL LEDS
ICON MEANING LED off. Slow blink. LED switch off with fast blinking on.
LED switch on with fast blinking off. Fixed LED switched on.
LED LED
MEANING Transmitter in operation. Channel activated when the start is
activated. Failure contact 1 of the E-Stop button. Transmitter stopped.
MEANING Standby status or battery OK. Battery in reserve. Empty battery.
Failure contact 2 of the E-Stop button.
11.2. LED INFORMATION DURING CHANGE OF FREQUENCY
· To activate the manual frequency change, both LEDs will flash alternately
until you press the validation for the frequency change.
· When finish the frequency change process (in manual and automatic mode) the working channel will be visualized through the LEDs:
o LED will produce as many pulses as tens have the channel.
o Later on the LED
will produce as many pulses as units have the channel.
Note: the remote control will not be started until the channel display ends.
25
REMOTE CONTROL COMBIPLUS
USER MANUAL
11.3. INFORMATION ABOUT FREQUENCY CHANNEL THROUGH LED
With the E-STOP BUTTON locked, insert the battery into the transmitter or, in
the case that it includes a key or switch, put them to the ON position while
keeping the START button pressed to know the working channel of the
transmitter using the LED lighting sequence described in section 11.2.
11.4. KEYBOARD LOCK
· To lock and unlock the keypad, press the START button 5 times in less than
three seconds with the ESTOP BUTTON locked.
· If the keyboard is locked both LEDs and flash at the same time, trying to start the equipment.
· When the keyboard is blocked, both LEDs and
light up for 3 seconds.
· When the keyboard is unlocked, both LEDs and
lash three times at the same time.
11.5. SUMMARY TO CHANGE THE FREQUENCY BAND (NOT VALID FOR GCFI VERSIONS)
1º
Unlock the STOP BUTTON and remove the battery or, in case it is equipped with
a key or switch, put it in the OFF position.
ON/OFF
TENS
EMERGENCY STOP
2º Press the START button and the UNIT joystick simultaneously. Keep them
pressed. Turn the ON/OFF switch or key to the ON position.
3º The LEDs will flash simultaneously from one to three times indicating the
mode of operation that has been programmed. – Mode 1: frequency change
disabled (1 flash). – Mode 2: frequency change in manual mode (2 flashes). –
Mode 3: frequency change in automatic mode (3 flashes).
26
UNITS START
REMOTE CONTROL COMBIPLUS
USER MANUAL
11.6. SUMMARY TO CHANGE MANUALLY THE FREQUENCY BAND (NOT VALID FOR GCFI VERSIONS)
1º
Press the START button and the STOP button simultaneously.
ON/OFF
TENS
EMERGENCY STOP
2º
Press the UNITS and TENS joystick as many times as necessary to enter the
desired channel number.
3º Press the VALIDATE button.
UNITS
Manoeuvre for START Manoeuvre for VALIDATE
27
REMOTE CONTROL COMBIPLUS
USER MANUAL
11.7. SUMMARY TO CHANGE THE TRANSMISSION TIME
1º
Lock the STOP BUTTON and remove battery or, in case it has a key or switch,
put them in OFF position.
ON/OFF
TIME
2º
Operate the joystick marked as TIME and, keeping it pressed, turn the on/off
switch or key to the ON position.
EMERGENCY STOP
3º Wait approximately 3 to 5 seconds and unlock the stop button.
4º Release the TIME joystick and activate it again.
5º The LEDs for start and battery will flash at the same time indicating the
programmed time: – Mode 1: 180 seconds (one flash). – Mode 2: 330 seconds (two
flashes). – Mode 3: continuous emission (three flashes).
TIME
28
REMOTE CONTROL COMBIPLUS
USER MANUAL
12. RECYCLABILITY
INFORMATION FOR THE CORRECT MANAGEMENT OF ELECTRICAL WASTE AND ELECTRONIC
EQUIPMENT (RAEE). At the end of the lifetime of the device, it must not be
disposed together with general waste. It can be delivered, free of charge, to
specific collection places, differentiated by local authorities, or
distributors that provide this service. Separately disposing an electronic
waste means avoiding possible negative consequences for the environment,
resulting from improper disposal. And also allows a treatment and recycling of
the materials that compose it, obtaining important savings in energy and
resources.
TO UNDERLINE THE OBLIGATION TO COOPERATE WITH SEPARATE COLLECTION, THE PRODUCT
IS MARKED WITH A WARNING AGAINST THE USE OF TRADITIONAL CONTAINERS FOR
DISPOSAL. For further information, please contact the relevant authorities.
12.1. PACKAGING
· The materials used in the packaging are recyclable. · When disposing of it,
please follow the local regulations for the treatment of this type of waste.
29
REMOTE CONTROL COMBIPLUS
USER MANUAL
www.itowa.com
SINDITO, S.L. Faraday, 159 08224 Terrassa (Barcelona) Spain Tel. +34 93 733 98
50
30