Specifications

  • Inverters & Protocol supported (Up to 16 Batteries to 1 inverter allowed)
    • CAN: Pylon (Default), Growwatt, Victron, Goodwe, GinLong, Pengcheng, Sofar, etc.
    • 485: Pylon (Default), Sol-Ark/SRNE, Growwatt, Deye, Voltronic, Paceic
  • Hardware-Ports/Wiring
    • Port: BMS Port (CAN & 485 share the same port)

Inverters & Protocol supported (Up to 16 Batteries to 1 inverter allowed)
Make sure the inverter supports one of the following protocols:

  • CAN: Pylon (Default), Growwatt, Victron, Goodwe, GinLong, Pengcheng, Sofar etc
  • 485: Pylon (Default), Sol-Ark/SRNE, Growwatt, Deye, Voltronic, Paceic

Hardware-Ports/Wiring

  • Port: BMS Port (CAN & 485 share the same port) as shown below. Refer to inverter’s user manual and locate the battery communication port on the inverter.

DO NOT USE internet cable for the communication between the inverter and the battery.
Make a cable according to your applications as follows:

  • For RS485 Protocol, use the following PINs:
    • PIN#1—————–485B
    • PIN#2—————–485A
  • For CAN Protocol, use the following PINs:
    • PIN#4—————–CAN_H
    • PIN#5—————–CAN_L

Check the Inverter’s manual and find out the PIN out of RS485 or CAN, and crimp the connectors. Mark one side “INVERTER” and the other side “BATTERY” ONLY 2 wires should be crimped into the RJ45 connectors. Use a multimeter to check and confirm the conductivity of the cable.

Connect Procedures

ONLY USE the RS485/CAN port to connect to the inverter.
If the inverter supports Pylon (CAN or 485), nothing needs to be done on the battery BMS. If different protocols need to be used, See the PC-Battery Communications Instructions and update the default protocol in the battery BMS to the one supported by the inverter.

  • Single Battery
    • Connect the “INTERTER” side RJ45 to the port of BMS on the inverter
    • Connect the “BATTERY” side RJ45 to the port of RS-485/CAN(!!NOT RS485 ports!!)
    • DIP: ALL OFF (See Multiple Batteries setup for Multiple Battery Applications)
    • Connect the battery and Power ON the inverter, go to the menu that enables BMS communication (Inverter specific), the inverter might beep for warning.
    • Choose Pylon (or other protocols) and confirm
    • The inverter and the battery should be connected, and the warning beep will stop.
  • Multiple batteries (SOC is the average of all batteries) DIP
    • Set one of the batteries as the Master battery, which is connected to the inverter using the RJ45 cable made in section 2: DIP 1-4, OFF (Set as MASTER, address 0); DIP 5-8 as the total quantity of the slaves that are connected to the Master. The table is as follows:
      Slave QTY| DIP#1| DIP#2| DIP#3| DIP#4| DIP#5| DIP#6| DIP#7| DIP#8
      ---|---|---|---|---|---|---|---|---
      1| OFF| OFF| OFF| OFF| ON| OFF| OFF| OFF
      2| OFF| OFF| OFF| OFF| OFF| ON| OFF| OFF
      3| OFF| OFF| OFF| OFF| ON| ON| OFF| OFF
      4| OFF| OFF| OFF| OFF| OFF| OFF| ON| OFF
      5| OFF| OFF| OFF| OFF| ON| OFF| ON| OFF
      6| OFF| OFF| OFF| OFF| OFF| ON| ON| OFF
      7| OFF| OFF| OFF| OFF| ON| ON| ON| OFF
      8| OFF| OFF| OFF| OFF| OFF| OFF| OFF| ON
      9| OFF| OFF| OFF| OFF| ON| OFF| OFF| ON
      10| OFF| OFF| OFF| OFF| OFF| ON| OFF| ON
      11| OFF| OFF| OFF| OFF| ON| ON| OFF| ON
      12| OFF| OFF| OFF| OFF| OFF| OFF| ON| ON
      13| OFF| OFF| OFF| OFF| ON| OFF| ON| ON
      14| OFF| OFF| OFF| OFF| OFF| ON| ON| ON
      15| OFF| OFF| OFF| OFF| ON| ON| ON| ON
    • Set slave battery addresses as the following table:
      ADDRESS| DIP#1| DIP#2| DIP#3| DIP#4| DIP#5| DIP#6| DIP#7| DIP#8| SLAVES
      ---|---|---|---|---|---|---|---|---|---
      1| ON| OFF| OFF| OFF| OFF| OFF| OFF| OFF| BATTERY 1
      2| OFF| ON| OFF| OFF| OFF| OFF| OFF| OFF| BATTERY 2
      3| ON| ON| OFF| OFF| OFF| OFF| OFF| OFF| BATTERY 3
      4| OFF| OFF| ON| OFF| OFF| OFF| OFF| OFF| BATTERY 4
      5| ON| OFF| ON| OFF| OFF| OFF| OFF| OFF| BATTERY 5
      6| OFF| ON| ON| OFF| OFF| OFF| OFF| OFF| BATTERY 6
      7| ON| ON| ON| OFF| OFF| OFF| OFF| OFF| BATTERY 7
      8| OFF| OFF| OFF| ON| OFF| OFF| OFF| OFF| BATTERY 8
      9| ON| OFF| OFF| ON| OFF| OFF| OFF| OFF| BATTERY 9
      10| OFF| ON| OFF| ON| OFF| OFF| OFF| OFF| BATTERY 10
      11| ON| ON| OFF| ON| OFF| OFF| OFF| OFF| BATTERY 11
      12| OFF| OFF| ON| ON| OFF| OFF| OFF| OFF| BATTERY 12
      13| ON| OFF| ON| ON| OFF| OFF| OFF| OFF| BATTERY 13
      14| OFF| ON| ON| ON| OFF| OFF| OFF| OFF| BATTERY 14
      15| ON| ON| ON| ON| OFF| OFF| OFF| OFF| BATTERY 15
    • Connect one of the master 485 port (Not CAN/485) to a RS485 port on the slave, and connect those slaves using RS485 ports (Not CAN/485). Internet cable for router can be used for Master-Slave, Slave-Slave communications. See the diagram as follows:AntraPower-BLF-48105H-Antra-LiFePO4-Lithium-Ion-Batteries-2

Trouble Shooting

  • Check the cable conductivity
  • Check the correct port is used
  • Check the protocol match CAN to CAN, 485 to 485 etc.
  • Check the DIP pin settings are correct
  • Call customer support 1-888-450-6788

FAQ

  1. Q: How many batteries can be connected to one inverter?
    A:
    Up to 16 batteries can be connected to one inverter.

  2. Q: Can I use an internet cable for communication between the inverter and the battery?
    A:
    No, it is not recommended to use an internet cable for this purpose. Please follow the instructions provided in the user manual.

  3. Q: How do I update the default protocol in the battery BMS?
    A:
    Please refer to the PC-Battery Communications Instructions for detailed steps on updating the default protocol in the battery BMS.