How to start vehicle when battery is flat?

When starting the car, please make sure that the power of the product is above 50%. Connect the EC5 end of the smart cable clamp to the product.
Then clamp the red clamp of the smart cable clamp to the positive “+” pole of the car battery and the black clamp to the negative” – “pole of the car battery.

Acetek-QC3.0-Jump-Starter-1

  1. Plug the smart cable clamp into the jump starter
  2. Connect the smart cable clamp to the car battery (Red is positive and Black is negative)
  3. Start your vehicle engine
  4. After the car has been started, remove the plug from the jump starter and remove the clamps from the car battery

Acetek-QC3.0-Jump-Starter-2

How to use the jumper cable?

  1. Fully insert the plug into the jump starter.
    THE GREEN LIGHT IS BLINKING
    This means that the jumper cable is correctly connected to the jump starter.

  2. Connect the clamps to the vehicle battery. Red clamp is connected to the positive polarity (+), black clamp is connected to the negative polarity (-).
    THE GREEN LIGHT IS ALWAYS ON
    All connections are right, try to start the engine. If there is no operation within 30 seconds after the connection is successful, the current is turned off, the green light is flashing, the jump start function is invalid, please reconnect to the car battery.)

  3. Press the car start button or turn the ignition switch to the START position.

  4. After the car has been started, the green light is strobing , please remove the jumper cable.

PROTECTION FUNCTION: THE RED LIGHT IS ON, AND THE BEEPS WILL BE GOING ON FOR A LONG TIME.

  • Jump starter power is low, please recharge.
  • Reverse polarity connection, please reconnect correctly.
  • The red and black clamps are short-circuited, please reconnect correctly.It is strictly forbidden to short-circuit the positive and negative poles after the clamp is energized.)
  • When the temperature of the jumper cable is high (≥65 ‡ 5°C), waiting to cool down (≤55 ‡ 5°C) before the next start.

PRECAUTIONS

  1. Please connect the jumper cable correctly according to the requirements of the manual.
  2. Do not jump start the car at high frequency continuously.
  3. This jumper cable is not allowed to be heated or used near fire.
  4. This jumper cable is not allowed to be put into water or disassembled or modified without authorization.
  5. The jumper cable needs to be connected to the jump starter first, and then connected to the car battery for ignition to avoid misjudgment.
  6. When the car is not connected to the battery, the cable clip does not support the reverse connection protection; if you remove the power cord from the car battery, do not connect it in reverse when starting the car.

How to charge a mobile phone or digital products?

Acetek-QC3.0-Jump-Starter-6

Step 1:
Plug the USB port of the charging cable into the product USB interface

Step 2:
Inset the other side into the input port of the mobile phone

Step 3:
Press power button then you can use it to charge now

The machine has output short-circuit protection function: the output is automatically turned off when short-circuited (after the fault is removed, it needs to be restored by pressing the button or activated by charging).

How can led emergency light be turned on?

Acetek-QC3.0-Jump-Starter-7

Long press for 2 seconds in any mode to turn off the LED lamp function.

How to recharge the product?

First step:
Insert the charging cable.

Acetek-QC3.0-Jump-Starter-8

Second step:
Connect the charging cable to a USB port to recharge the product.

Display Function

While charging:
The digital tube displays” “, and the percentage value of the power percentage flashes (1 flash for 1 second). When it is charged to 100% power, it stops flashing and stops charging; after 10 seconds, the digital tube display turns off and enters the sleep state.

When discharging:

  1. When the output is SV, the digital tube displays “ “, and the current percentage value of the product’s power is displayed at the same time.
  2. When the QC3.0 fast charge is output, the digital tube displays” ” and” “, and at the same time displays the current battery percentage value of the product.
  3. In the working state, the discharge of the ECS port can indicate the power normally.
  4. When no load or light load is connected, the LED screen will turn off after 30±5S, and enter the sleep mode.

Temperature indication :

  1. When the battery is under high/low temperature protection during charging, the” ■” character of the nixie tube flashes (one flash for 1 second), and it automatically resumes charging and indicates the current battery level after the protection is lifted.
  2. After the battery is protected from high temperature during discharge, the” ■” character of the digital tube flashes (1 flash for 1 second), and goes to sleep after 10 seconds.