WAGNER W 690 FLEXiO Universal Sprayer Instruction Manual

June 14, 2024
Wagner

WAGNER W 690 Flexion Universal Sprayer

WAGNER W 690 FLEXiO Universal Sprayer

Explanation of symbols used

| This symbol indicates a potential danger for you or for the device.
Under this symbol you can find important information on how to
avoid injuries and damage to the device.
---|---
| Danger of electrical shock
| Indicates tips for use and other particularly useful information.

General Safety Instructions

Caution!

Read all the instructions. Non-observance of the instructions below can cause electric shock, fire and or serious personal injuries. The term “power tool” used below covers both mains-operated power tools (with mains lead) and accumulator-operated power tools (without mains lead).

  1. Safety at the workplace Safety at the workplace
    a) Keep your workplace clean and well lit. Disorder or unlit workplaces may result in accidents.
    b) Never use the tool in hazardous areas that contain flammable liquids, gases or dusts. Power tools generate sparks that can ignite the dust or vapors.
    c) Keep children and other persons away when using the power tool. You can lose control of the tool if you are distracted.

  2. Electrical Safety
    a) The tool plug must fit into the socket. The plug may not be modified in any form.
    Do not use adaptor plugs together with protective-earthed tools. Unmodified plugs and suitable sockets reduce the risk of an electric shock.
    b) Avoid physical contact with earthed surfaces such as pipes, heating elements, stoves and refrigerators. The risk through electric shock increases if your body is earthed.
    c) Keep the equipment away from rain and moisture. The risk of an electric shock increases if water penetrates electrical equipment.
    d) Do not misuse the mains lead by carrying the tool by the lead, hanging it from the lead or by pulling on the lead to remove the plug. Keep the lead away from heat, oil, sharp edges or moving tool parts. Damaged or twisted leads increase the risk of an electric shock.
    e) If you work outdoors with a power tool, only use extension cables suitable for outdoor use. The use of an extension lead that is suitable for outdoors reduces the risk of an electric shock.
    f) If you cannot avoid using the tool in a damp environment, use a residual current operated circuit-breaker. Using a residual current operated circuit-breaker avoids the risk of electric shock.

  3. Safety of Persons
    a) Be attentive. Pay attention to what you are doing and work sensibly with a power tool. Do not use the tool if you are tired or under the influence of drugs, alcohol or medication. Just a moment of inattentiveness while using the tool can lead to serious injuries.
    b) Wear personal safety equipment and always wear safety goggles Wearing personal protective equipment, such as dust mask, non-slip safety shoes, safety helm or ear protection, depending on the type of power tools, reduces the risk of injury.
    c) Avoid accidental starting-up. Make sure that the electric tool is switched off before you connect it to the power supply, pick it up or carry it. Accidents can occur if you carry the power tool while your finger is on the switch or if you connect the power tool to the power supply which it is on.
    d) Remove setting tools or wrenches before switching on the power tool. A tool or wrench that is in a rotating tool part can lead to injuries.
    e) Avoid an unnatural posture. Ensure that you are standing securely and have your balance at all times. This ensures that you can control the tool better in unexpected situations.
    f) Wear suitable clothing. Do not wear wide clothing or jewellery. Keep your hair, clothes and gloves away from moving parts. Loose clothing, jewellery or long hair can be caught in moving parts.
    g) Do not lull yourself into a false sense of security and do not think yourself above the safety rules for electric tools, even if you are familiar with the electric tool following extensive practical experience. Careless use can lead to serious injuries in fractions of a second.

  4. Usage and treatment of the electric tool
    a) Do not overload the tool. Use the power tool designed for the work that you are doing. You work better and safer in the specified performance range if you use the suitable power tool.
    b) Do not use power tools whose switch is defective. A power tool that cannot be switched on or off is dangerous and has to be repaired.
    c) Remove the plug from the socket before carrying out tool settings, changing accessories or putting the tool away. This precautionary measure prevents unintentional starting of the tool.
    d) Store unused power tools so that they are inaccessible to children. Do not let persons use the tool who are not familiar with it or who have not read these instructions. Power tools are dangerous when they are used by inexperienced persons.
    e) Take proper care of your tools. Check whether the moving parts function trouble-free and do not jam, whether parts are broken or damaged so that the tool function is impaired. Have damaged parts repaired before using the tool. Many accidents have their origin in power tools that have been maintained badly.
    f) Use the power tool, accessories, insert tools, etc. in accordance with these instructions and in a fashion specified for this special tool type. Take the working conditions and the activity to be carried out into consideration. The use of power tools for purposes other than the intended ones can lead to dangerous situations.
    g) Keep the handles and grip surfaces dry, clean and free of oil and grease. Slippery handles and grip surfaces hamper safe operation and control of the electric tool in unforeseen situations.

  5. Service
    a) Have your tool repaired only by qualified specialist personnel and only with original spare parts. This ensures that the tool safety is maintained.
    b) If the supply cord is damaged, it must be replaced by the manufacturer or it’s service agent or a similarly qualified person in order to avoid a safety hazard.

Safety Instructions for Spray Guns

CAUTION! Wear breathing equipment: Paint mist and solvent vapors are damaging to health. Always wear breathing equipment and only work in well ventilated rooms or using supplementary ventilating equipment. It is advisable to wear working clothing, safety glasses, ear protection and gloves.

ICONCAUTION: Danger of injury! Never point the spray stream towards human beings or animals. ****Sockets and plugs must be masked. Risk of an electric shock as a consequence of sprayed material entering the socket!

Attention! Never operate the device if the nozzle seal is either damaged or missing. If the nozzle seal is either missing or damaged liquids can enter the device and increase the risk of an electric shock. Check the nozzle seal before each use and tighten the union nut.

  • The spray guns are not to be cleaned with flammable solvents.

  • Caution against dangers that can arise from the sprayed substance and observe the text and information on the containers or the specifications given by the substance manufacturer.

  • Do not spray any liquid of unknown hazard potential.

  • The device may not be used in workplaces covered by the explosion-protection regulations.

  • To avoid the hazard of explosion when spraying, provide for effective natural or artificial ventilation.

  • There must be no sources of ignition such as, for example, open fires, smoke of lit cigarettes, cigars and tobacco pipes, sparks, glowing wires, hot surfaces, etc. in the vicinity during spraying.

  • Ensure that no solvent vapors are sucked in by the unit. Do not spray onto the unit!

  • The spray gun is not a toy; children must therefore not be allowed to handle it or play with it.

  • Before working on the spray gun remove the power plug from the socket.

  • Cover areas that are not to be sprayed. When working keep in mind that wind, for example, may transport paint mist over great distances and cause damage.

  • The units may only be used with a functional valve. If paints rises in the ventilating hose (Fig. 1, item 18) do not operate the unit further! Dismantle and clean the ventilating hose, valve and diaphragm and replace the diaphragm if necessary.
    Safety Instructions for Spray Guns

  • Do not lay the spray gun.

With original WAGNER accessories and spare parts, you have the guarantee that all safety regulations are fulfilled.

Description/ Scope of delivery

Description/ Scope of delivery (Fig. 1)

  1. Air cap| 2) Nozzle
  2. Union nut| 4) Standard spray attachment
  3. Trigger| 6) Material volume regulation
  4. Gun handle| 8) ON/OFF switch
  5. Carry handle| 10) Air volume control
  6. Air hose| 12) Power cable
  7. Cover of air filter compartment| 14) Air filter
  8. Gun holder| 16) Container (800 ml)
  9. Valve 18) Ventilating hose
  10. Carrying belt| 20) Wall Extra I-Spray spray attachment
  11. Stirring rod| 22) Feed hopper (2 pcs.)
  12. Replacement nozzle seal (Standard spray attachment)*| 24) Practice poster
  13. Operating instructions| 26) Lubricating grease (without illustration)*
  • This is inside the container: remove it before starting operations!

Field of application

Many different coating substances can be processed with the W 690.
A different spray attachment must be used, depending on the coating substance:

Coating Materials Suitable for Use Spray attachment

Low-viscosity coating substances:
Water- and solvent-based paints, finishes, primers, 2-component paints, clear finishes, automotive finishes, staining sealers and wood sealer- preservatives.| Standard
Interior wall paint (dispersions and latex paint)| Wall Extra I-SprayField
of application
Coating Materials Not Suitable for Use

Materials that contain highly abrasive components, façade paint, caustic solutions and acidic coating substances. Flammable materials.

Preparation of the workplace (for interior wall paint)

ICONSockets and plugs must be masked. Risk of an electric shock as a consequence of sprayed material entering the socket!
Mask all the areas and objects that are not to be spray painted, or remove them from the work area. No liability is assumed for damage due to overspray.
Silicate paint corrodes glass and ceramic surfaces upon contact! All such surfaces must therefore be completely covered.

Pay attention to the quality of the adhesive tape used.
Do not use excessively strong adhesive tape on wallpaper and painted surfaces, in order to avoid damaging these surfaces when removing the tape. Remove adhesive tape slowly and evenly; do not use jerky movements.
Do not leave adhesive tape on surfaces any longer than necessary, in order to minimise the possibility of residues when removing.
Also observe the adhesive tape manufacturer’s instructions.

Preparation of the Coating Material

  • Mix the material well in the original container. When using interior wall paint, an agitator is recommended.

W 690 has been developed for use with all conventional paints in their undiluted form. If the surface is smooth and the paint you are using is very thick and gel-like, dilute it by 10%. Dilution can be necessary if the atomisation is coarse or if the flow rate is too low even at the maximum setting. Detailed information about the various materials and the maximum permitted dilution can be found on the manufacturers’ technical data sheets (e.g. available on the Internet).
Spray material that is at least at room temperature provides a better spray result.

Start-up

Before connecting to the mains supply, be sure that the supply voltage is identical with the value given on the rating plate.
Put the machine down only on a level, clean surface. Otherwise, the gun may suck in dust, etc.

  1. Attach the carrying strap to the unit. (Fig. 2)
    Start-up

  2. Unscrew the container from the spray gun.

  3. Aligning suction tube. (Fig. 3)If the suction tube is positioned correctly, the container contents can be sprayed without almost any residue.
    When spraying horizontal surfaces, turn suction tube forward. (Fig. 3 A) When spraying objects overhead, turn suction tube back. (Fig. 3 B).

For easier coating of ceilings and lying objects, we recommend the 60 cm Universal Extra Extension. (Order no. 2361756)

  1. Set the container on a sheet of paper, pour in the prepared coating material and screw the container tightly onto the spray gun.

  2. Connect the front part with the rear part of the gun. (Fig. 5)
    Start-up

  3. Mount the air hose (Fig. 4, A + B). Insert the air hose firmly into the connection of the unit and the gun handle. The position of the hose is not relevant.

  4. Sling on the carrying strap with the unit.

  5. Press the ON/OFF switch at the device.

The enclosed practice poster is ideal for familiarizing yourself with operation of the spray gun. After trying out the first spray coatings, it makes sense to test it further on cardboard or a similar surface in order to find out the right flow rate of paint and air for the best spray pattern. Detailed information about these settings can be found in chapter 11- 15.

Selecting the Spray Setting (Standard spray attachment)

ICONWARNING! Danger of injury! Never pull the trigger guard while adjusting the air cap.
With the union nut (fig. 6, 1) slightly unscrewed, turn the air cap ( 2 ) to the desired spray setting position (arrow). Then tighten the union nut.
Selecting the Spray Setting \(Standard spray
attachment\)

Fig. 7 A = vertical flat jet → for horizontal surfaces
Fig. 7 B = horizontal flat jet → for vertical surfaces
Fig. 7 C = circular jet → for corners, edges and hard-to-reach surfaces
Selecting the Spray Setting \(Standard spray
attachment\)

Selecting the Spray Setting

(Wall Extra I-Spray spray attachment)

ICONWARNING! Danger of injury! Never pull the trigger guard while adjusting the air cap.

2 different spray jet shapes can be set by turning the air cap (fig. 8, 1)

****Tighten the union nut (Fig. 8, 2) fully so that no paint is able to penetrate the device. Check regularly whether the union nut has worked loose during operation.
Selecting the Spray Setting

Fig. 9 A = vertical flat jet → for horizontal surfaces
Fig. 9 B = horizontal flat jet → for vertical surfaces
Selecting the Spray Setting

Use the red adjustment lever to also switch between a wide ( ▷ ) and a narrow ( ▻ ) spray jet.
Selecting the Spray Setting

Adjusting the Material Volume

(Standard spray attachment) (Fig. 10)

Set the material volume by turning the regulator on the trigger guard of the spray gun.
– turn to the left → lower material volume
+ turn to the right → higher material volume
Selecting the Spray Setting

Adjusting the Material Volume

(Wall Extra I-Spray spray attachment)

The volume of material can be set by turning the material volume control (Fig. 11, 1) in steps from 1 (minimum) to 12 (maximum).
Selecting the Spray Setting

Setting the Amount of Air (Fig. 12)

Setting the Amount of Air

Depending on the viscosity of the material to be sprayed and the finish of the object to be coated, it may be advisable to vary the amount of air. Very low viscosity materials, such as watery glazes do not have to be atomized with the maximum amount of air. In this case it is advisable to reduce the amount of air and thus minimize the spray vapour.
This also applies for the use of the Detail and Corner Reach spray attachment (accessory).
– turn to the right → lower amount of air
+ turn to the left → higher amount of air

Spray Technique

****The spray result depends heavily on the smoothness and cleanliness of the surface to be sprayed. Therefore the surface should be carefully prepared and kept free of dust.

  • Cover all surfaces not to be sprayed.
  • Cover screw threads or similar parts of the target object.

**Important: Start at the edge of the area to be sprayed. Start the spray movement first of all, and then press the trigger. Avoid interruptions within the area to be sprayed.**

  • The spray movement should come from the arm, not just from the wrist. This ensures that a uniform distance is maintained between the spray gun and the spray surface during the spray operation. Select a distance of 5 – 15 cm, depending on the desired spray jet width. When you are using interior wall paint, the distance should be about 20-30 cm (approx. one stirring rod in length).

Fig. 13 A/ 13 B: CORRECT Even distance to the object.
Fig. 13 B: INCORRECT An uneven distance will result in uneven paint application.
Spray Technique

  • Move the spray gun evenly cross-wise or up-and-down, depending on the spray pattern setting.
  • An even movement of the spray gun results in an even surface quality.
  • When coating material builds up on the nozzle and air cap, clean both parts with a solvent or water.
    “Cross spray” when using paint with a poor covering capacity or if the surface is highly absorbent (Fig. 14).
    Interior wall paint in strong colour shades should be applied at least twice(allow first paint coat to dry first). This will ensure good coverage.
    Spray Technique

interruption of Work till 4 Hours

  • Turn the machine off.
  • During longer breaks, vent the container by briefly opening and then closing it again.
  • Clean nozzle openings after an interruption in operation.
  • When processing 2-component varnishes, clean the device immediately

Taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application device. No warranty claims are accepted in case of improper or no cleaning.

  1.  Turn the machine off. Vent the container in case of longer breaks and after the work has been terminated. This can be done by briefly turning open and then closing the container or by pulling the trigger guard and letting the paint into the original paint container.
  2.  Divide the spray gun. Press the hook (Fig. 5 “click”) slightly downwards. Turn the gun front part and gun rear part against each other and take them apart.
  3. Unscrew the container. Empty any remaining coating material back into the material tin.
  4.  Pull out the suction tube with container seal.
  5.  Preclean the container and suction tube with a brush. Clean the ventilating bore
    (Fig. 15, A).
    Taking Out of Operation and Cleaning

Cleaning the Standard spray attachment

CAUTION! Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal objects.

The ventilation hose and diaphragm are only solvent-resistant to a limited extent. Do not immerse in solvent, only wipe.

  1. The unit may only be operated with an integer diaphragm (Fig. 16, C). If unipoint has penetrated to the ventilation hose, check and clean the membrane (see the Maintenance chapter).
    Cleaning the Standard spray attachment

  2.  Unscrew the union nut and remove the air cap and nozzle. (Fig. 17)
    Cleaning the Standard spray attachment
    Clean the air cap, nozzle seal and nozzle with a brush and solvent or water.

  3.  Clean the outside of the spray gun and container with a cloth soaked in solvent or water.

  4.  Assemble the parts again (see “Assembly”).

Assembly

Attention! Never operate the device if the nozzle seal is either damaged or missing. If the nozzle seal is either missing or damaged liquids can enter the device and increase the risk of an electric shock.

  1. Push the nozzle seal (fig. 18, 1) over the needle (3); the groove (slot) should point towards you.

  2.  Put the nozzle (fig. 18, 2) onto the gun body and find the correct position by turning it.
    Cleaning the Standard spray attachment

  3. Put the air cap onto the nozzle and tighten it using the union nut.

  4. Place the container seal from below on the suction tube and slide it over the collar, while turning the container seal slightly.

  5. Insert the suction tube with container seal in the gun body. In order to mount the gun more easily apply lubricating grease (enclosed) liberally to the O-ring at the gun front part. (Fig. 17, A)

Cleaning the Wall Extra I-Spray spray attachment

CAUTION! Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal objects. The ventilation hose and diaphragm are only solvent-resistant to a limited extent. Do not immerse in solvent, only wipe.

  1. The unit may only be operated with an integer diaphragm (Fig. 16, C). If any paint has penetrated to the ventilation hose, check and clean the membrane (see the Maintenance chapter).

  2.  Move the air cap (Fig. 19, 1) to the vertical position for easier removal and lift it off.

  3. Unscrew the union nut (fig. 19, 2). Clean the air cap (1) and nozzle (3) with a brush and solvent or water. Attention! Never remove the red nozzle seal from the nozzle. If the nozzle seal is either missing or damaged liquids can enter the device and increase the risk of an electric shock.
    Cleaning the Wall Extra I-Spray spray attachment

  4. Clean the outside of the spray gun and container with a cloth soaked in solvent or water.

  5. Assemble the parts again (see “Assembly”).

Assembly

Attention! Never operate the device if the nozzle seal is either damaged or missing. If the nozzle seal is either missing or damaged liquids can enter the device and increase the risk of an electric shock.

  1.  Check the nozzle seal (fig. 20, 4) in the nozzle.
    Cleaning the Wall Extra I-Spray spray attachment

  2.  Screw the union nut (Fig. 21, 2) onto the gun and tighten it.

  3. ****Tighten the union nut (Fig. 21, 2) fully so that no paint is able to penetrate the device.
    Cleaning the Wall Extra I-Spray spray attachment

  4.  Engage the air cap (Fig. 22, 1) with the union nut. Check if the air cap has properly locked into place on both sides. (Fig. 22, 2)
    Cleaning the Wall Extra I-Spray spray attachment

  5. Place the container seal from below on the suction tube and slide it over the collar, while turning the container seal slightly.

  6.  Insert the suction tube with container seal in the gun body.
    In order to mount the gun more easily apply lubricating grease (enclosed) liberally to the O-ring at the gun front part. (Fig. 26, 3)

Maintenance

Air filter

WARNING! Never operate the machine without the air filter; dirt could be sucked in and interfere with the function of the machine. Check the air filter after each use for contaminants. Disconnect plug before changing parts.

Replace the air filters depending on soiling. Unplug the power plug. Open the cover of the air filter compartment (Fig. 23, A). Replace both air filters (Fig. 23,   B). Close the cover of the air filter compartment.
Maintenance

Ventilating hose / Valve

  1.  Pull the ventilating hose (Fig. 16, A) at the top from the gun body. Screw off the valve cover (B). Remove the diaphragm (C). Carefully clean all parts or replace in the event of damage.
  2.  Place the diaphragm (Fig. 16, C) with the pin facing upwards on the bottom section of the valve. Also see the marking on the gun body.
  3.  Place on the valve cover (Fig. 16, B) and screw it closed.
  4. Place the ventilating hose (Fig. 16, A) on the valve cover and on the nipple at the gun body
    Spare Parts List Standard spray attachment (Fig. 25)

    Pos.| Designation| Order No.
    | Standard spray attachment complete with 800 ml container| 2361 730
    1| Union nut| 2362 873
    2| Air cap| 2362 877
    3| Nozzle| 2362 878
    4| Nozzle seal| 0417 706
    5| O-ring of spray attachment| 2362 875
    6| Ventilating hose, valve cover, diaphragm| 2304 027
    7| Suction tube (no marking or R) Suction tube (marking AR or AU)| 2362 876
    2367 410
    8| Container seal (no marking or R) Container seal (marking AR or AU)| 2323 039
    2370 527
    9| Container with cover 800 ml| 0413 909

  • Before placing the order, please check the bottom of the inside of your spray attachment to see if there is a marking there. Do this by unscrewing the container and removing the container seal.

Spare Parts

Spare Parts List Wall Extra I-Spray spray attachment (Fig. 26)

Pos.| Designation| Order No.
| Wall Extra I-Spray spray attachment complete with 1800 ml container| 2361 749
1| Air cap| 2382 753
2| Union nut and nozzle| 2382 751
3| O-ring of spray attachment| 2362 875
4| Ventilating hose, valve cover, diaphragm| 2382 754
5| Suction tube| 2389 021
6| Container seal| 2389 023
7| Container with cover 1800 ml (only for Wall Extra I-Spray spray attachment)| 2304 025
Spare Parts List W 690 Flexio (Fig. 27)

Pos.| Designation| Order No.
1| Carrying belt| 2322 299
2| Gun handle| 2362 879
3| Air hose| 2362 880
4| Cover of air filter compartment (right and left)| 2316 052
5| Air filter (2 pcs.)| 2318 585
6| Stirring rod| 2304 419
7| Feed hopper (3 pcs.)| 2304 028
| Lubricating grease| 2315 539

 Accessories

The CLICK&PAINT SYSTEM with additional spray attachments and accessories offers the right tool for each work. Further information about the WAGNER range of products for renovating is available under www.wagner- group.com

Environmental protection

The device and all accessories and packaging have to be recycled in an environmentally friendly manner. Do not dispose of the appliance with household waste. Support environmental protection by taking the appliance to a local collection point or obtain information from a specialist retailer.
Leftover paint and solvents may not be emptied into drains, the sewage system or disposed of as household rubbish. It has to be disposed of separately as special waste. Please pay special attention to the instructions on the product packaging

Important Note regarding Product Liability!

According to an EU directive, the manufacturer is only liable without limitation for faults in the product if all parts come from the manufacturer or have been approved by the manufacturer and have been mounted to the device and are operated properly. If thirdparty accessories or spare parts are used, the manufacturer is exonerated wholly or partly from his/her liability if use of the third-party accessories or spare parts have caused a defect in the product.

Correction of Malfunctions

Malfunction Cause Remedy
No coating material emerges from the nozzle
  • Nozzle clogged
  •  Material quantity too small
  • No pressure build-up in container
  • Container empty
  • Feed tube loose
  • Feed tube clogged
  •  Ventilating bore (Fig.15, A) clogged

|

  • Clean
  • Increase the quantity of

material

  • Tighten container
  • Refill
  • Insert
  • Clean
  • Clean

Coating material drips from the nozzle|

  • Coating material assembly at air cap, nozzle or needle
  • Nozzle loose
  • Nozzle seal worn
  • Nozzle worn

|

  • Clean
  • Union nut tighten
  •  Change
  • Change

Atomisation too coarse|

  • Material volume too large
  • Nozzle contaminated
  •  Air cap assembled incorrectly
  •  Viscosity of coating material too high
  • Too little pressure build-up in

container

  •  Air filter heavily soiled
  •  Amount of air too low

|

  • Reduce the material volume
  • Clean
  • Snap air cap properly

into place (fig. 22, 2)

  • Dilute further
  • Tighten container
  • Change
  • Turn the air volume

control to the left (+)

Spray jet pulsates|

  • Coating material in container running out
  •  Nozzle seal worn
  •  Air filter heavily soiled

|

  • Refill
  • Replace
  • Change

Coating material causes “paint tears”|

  • Too much coating material applied.

|

  • Reduce the material volume

Too much fog of coating material (Overspray)|

  • Distance to the object too large
  • Too much coating material applied
  •  Amount of air too high

|

  • Reduce distance
  • Reduce the material

volume

  • Turn the air volume control to the left (-)

Paint in the ventilating hose|

  • Diaphragm soiled
  • Diaphragm defective

|

  • Clean the diaphragm
  • Replace the diaphragm
Malfunction Cause Remedy
Poor covering capacity on the wall
  • Spray material is too cold
  • Highly absorbent surface or paint with poor covering capacity
  •  Distance too large

|

  • The material you are spraying should be at

room temperature

  • Cross spray (Fig. 14)
  • Closer to the object

Technical Data

Technical Data

Max. viscosity: Interior wall paint

Varnish paints, glazes, etc.

| **** 4000 mPas

170 DIN-s

Max. flow rate: Interior wall paint

Varnish paints, glazes, etc.

| **** 400 ml/min

200 ml/min

Power source| 230 V ~ , 50 Hz
Power consumption| 630 W
Atomizing output:| 200 W
Double insulation| ***
Sound pressure level
| 79 dB (A); Uncertainty K = 4 dB
Sound pressure output| 92 dB (A); Uncertainty K =4 dB
Oscillation level
| < 2.5 m/s²; Uncertainty K = 1.5 m/s²
Air hose length| 3.5 m
Weight| approx. 3.3 kg

  • Measured in accordance with EN 50580

Information about the oscillation level
The specified oscillation level has been measured according to a standard test procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational strain. Attention! The vibration emission value can differ from the specified value when the electric tool is actually in use, depending on how the electric tool is being used. It is necessary to specify safety measures to protect the operating personnel. These measures are based on an estimated shutdown during the actual conditions of use (all parts of the operating cycle are taken into consideration here, for example periods when the electric tool is switched off, and, when it is switched on but running without any load)

3 + 1 year guarantee on this WAGNER DIY product

In addition to the statutory warranty for this product, J. Wagner GmbH, based in 88677 Markoff, Germany, grants you a guarantee (device guarantee) of 36 months for this product. This guarantee is extended by a further 12 months if the product is registered within 28 days of purchase on the Internet at https://[go.wagner-group.com](http://go.wagner-group.com)/3plus1. The guarantee includes the free repair of defects which are demonstrably caused by the use of unsuitable materials in the product’s manufacture or by assembly errors, as well as the free replacement of faulty components provided there are no guarantee exclusions.
The statutory material defect rights to which you as the purchaser are entitled for the intended purpose from the time of handover of the purchased item are not restricted by  the guarantee. The guarantee, along with your statutory warranty rights, will expire if the device has been opened by persons other than authorised WAGNER service personnel. The detailed guarantee conditions can be obtained on request from our authorised WAGNER partners (see website or operating instructions) or in text form on our website: https://[go.wagner-group.com](http://go.wagner-group.com)/hf-warranty- conditions- Modifications reserved –

UKCA Declaration of conformity

We declare under sole responsibility that this product conforms to the following relevant regulations: Supply of Machinery (Safety) Regulations 2008 Electrical Equipment (Safety) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 The Waste Electrical and Electronic Equipment Regulations 2013 Applied harmonised standards BS EN 62841-1:2015, BS EN 50580:2012+A1:2013, BS EN IEC 55014-1:2021,BS EN IEC 55014-2:2021,BS EN 61000-3 2:2019+A1:2021, BS EN 61000-3-3:2013+A2: 2021,BS EN 62233:2008

EU Declaration of conformity

We declare under sole responsibility that this product conforms to the following
relevant stipulations:
2006/42/EC, 2014/30/EU, 2011/65/EU, 2012/19/EU
Applied harmonised norms:
EN 62841-1, EN 50580, EN 55014-1, EN 55014-2, EN IEC 61000-3-2, EN 61000-3-3, EN 62233
The EU declaration of conformity is enclosed with the product.
If required, it can be re-ordered using order number 2362407.

Warning
If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special purpose tools are required.
Warning: Do not connect the blue or brown wire to the earth terminal of the plug! The wires in this mains lead are coloured in accordance with the following code: blue = neutral brown = liveAs the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

EU Declaration of conformity

  • Should the moulded plug have to be replaced, never re-use the defective plug or attempt to plug it into a different 13 A socket. This could result in an electric shock.
  •  Should it be necessary to exchange the fuse in the plug only use fuses approved by ASTA in accordance with BS 1362. 5 Amp fuses may be used.
  •  To ensure that the fuse and fuse carrier are correctly mounted please observe the provided markings or colour coding in the plug.
  • fter changing the fuse, always make sure that the fuse carrier is correctly inserted. Without the fuse carrier, it is not permissible to use the plug.
  • The correct fuses and fuse carriers are available from your local electrical supplies stockiest.

K IMPORTER WAGNER SPRAYTECH (UK) LTD
Innovation Centre Silverstone Park, Silverstone Orthants NN12 8GX T + 44 (0) 1327 368410

References

Pages: 1 2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals