Product Information

  • Timer: The timer feature of the machine records the total working time while the machine is running. The maximum accumulated time range is 99999H, with a display accuracy of 0.1H for values up to 9999.9H and 1H for values above 9999.9H.
  • Filter Replacement Indicator: This indicator light is designed to monitor the usage of the filter. When the light is illuminated, it indicates that the filter has reached a state where it needs to be replaced.
  • Circuit Breaker Switch: This switch is used to interrupt the flow of electric current in case of an electrical overload or short circuit.
  • Auxiliary Outlet: An additional power outlet provided for connecting other devices or appliances.
  • HEPA: The product features HEPA (High-Efficiency Particulate Air) filtration technology, which helps capture and remove fine particles and allergens from the air.

Product Usage Instructions

  1. Ensure that the machine is properly plugged into a power source.
  2. To activate the timer function, start the machine by pressing the power button.
  3. The timer will begin recording the working time as soon as the machine starts running.
  4. If the filter replacement indicator light turns on, it means that the filter has reached its maximum usage and needs to be replaced.
  5. To replace the filter, refer to the instruction manual provided with the product for detailed steps.
  6. If a circuit overload or short circuit occurs, use the circuit breaker switch to interrupt the electric current.
  7. The auxiliary outlet can be used to connect other devices or appliances, ensuring they are compatible with the power requirements of the outlet.

IMPORTANT NOTICE: It is recommended to keep the packaging of the item in case warranty service is required. The limited warranty period for this CADPXS product is as follows

  • Six (6) months for parts and labor, including shipment charges for replacement parts or units.
  • One (1) year for parts and labor. The shipment fee to send the unit back to the manufacturer is not covered.
  • Ten (10) years for the Polyethylene body ONLY.

Limited Warranty Exclusions: This limited warranty covers manufacturing defects in materials or workmanship encountered during normal household, commercial, or noncommercial use. It does not cover the following

  • Damage caused by misuse, abuse, or negligence.
  • Damage due to unauthorized repairs or modifications.
  • Normal wear and tear of the product.
  • Damage caused by accidents, natural disasters, or other external factors.

READ AND SAVE THESE INSTRUCTIONS

WARNING!
Please note that the Shield 550 should only be used with parts approved by CADPXS .The use of unauthorized parts or alterations to the machine could void your warranty. Contact an approved distributor for further assistance.

To Avoid the Risk of Fire or Electric Shock

  • Unit must be electrically grounded.
  • Insert 3-prong plug directly into outlet with Ground Fault Circuit Interrupting device.
  • Do not use an adapter with this unit.
  • Do not use the unit in standing water.
  • If electrical parts get wet, they must be dried prior to use.

INTRODUCTION

The CADPXS Shield 550 is a convenient filtration system that cleans the air. The 550 uses an effective blend of air flow and advanced filtration to expel airborne particles like mold spores, dust, pollen, and pet dander. The Shield is ideal for for restoration jobs, including water, sewage, and fire.

IDENTIFICATION
Congratulations on purchasing a Shield 550 air scrubber. In order to take advantage of the warranty plan, be sure to note the serial number and date of purchase.

  • Serial Number: ————————–
  • Date of Purchase :————————–

HOW IT WORKS

  1. When set to maximum airflow, the 550 draws air through two types of filters- a pre-filter and a the CADPXS HEPA Filter.
  2. The first phase of filtration, the prefilter, catches the large particles, while the second phase of filtration, the CADPXS HEPA Filter, catches smaller particles, down to 0.3 microns.

SPECIAL FEATURES

Daisy-Chain Capability
Using the auxiliary outlet on the control panel, you can link up to 3 units together, creating a maximum airflow 550 CFM. You can also daisy-chain the machines when they are stacked vertically (limit of 2 units).

Multi-Positional
The CAD PXS Shield 550 can be operated in the vertical position, as well as, when stacked vertically (up to 2 units). When storing, the machines can be stacked horizontally to save space.

Removable Intake Panel
The Shield 550 is equipped with a removable panel on the intake side of the machine. The removable panel is quite useful in remediation applications, so you can draw air out the room and create more negative pressure (use a manometer to monitor air pressure).

To use panel

  1. Remove the panel.
  2. Install the machine outside the containment area to draw air out.
  3. Cut a hole in the containment plastic that is the size of the unit’s inlet.
  4. Insert the inlet into plastic and seal the circumference tightly with duct tape.

KEY FEATURES

CADPXS-Shield-550-with-3-In-1-Stage-Filtration-System-
\(1\)CADPXS-
Shield-550-with-3-In-1-Stage-Filtration-System- \(2\)

INSTRUCTIONS

SETUP

  1. Place the CADPXS Shield 550 so that it is in the upright, vertical position.
  2. Plug the machine into a standard 115 volt outlet.
    • Note : Each unit needs 3 amps to operate.
  3. Power the unit on and adjust the speed by turning the variable speed control. The maximum speed is 550 CFM and the minimum speed is 270 CFM.
  4. The Shield 550 can be operated in the vertical or horizontal position, depending on the exact situation. At this point, adjust the machine to the optimal position.

THE CONTROL PANEL

Variable Speed Control
The Variable Speed Control is used to adjust the power of the machine. Turn the knob in a clockwise direction, to increase the speed from maximum to minimum. The minimum speed setting is located immediately under the OFF button. You can switch to minimum speed by turning the knob counterclockwise.

Auxiliary Outlet
If more air filtration is necessary for a space, you can “daisy chain” or link up to 3 Shield 550’s to the same outlet. There is a maximum amperage of 10 when the units are turned off, a maximum of 9 amps when the units are turned on. Other equipment can be plugged into the same outlet as the Shield as long as it doesn’t go above the max amperage.

Circuit Breaker Switch
The Circuit Breaker Switch protects the unit if there are more than 10 amps of electricity passing the circuit. If this occurs, the switch will cut off the power to the unit.

Timer
When the machine is running, the meter starts working time. Record the total working time and cannot be cleared. The maximum accumulated time range is 99999H, ≤9999.9H, the display accuracy is 0.1H, >9999.9H, the display accuracy is 1H.

Filter replacement indicator
This light is to monitor the usage of the filter. When this light is on, it means that your filter has reached the state that needs to be replaced .CADPXS-Shield-550-with-3-In-1-Stage-Filtration-System-
\(3\)

CHANGING THE FILTERS

  1. Loosen the 2 locks that hold the filter board in place.
  2. Slide out the filter panel board.
  3. Remove the used filters and replace with new filters.

WARNING

  • Always wear approved protective gear when changing the filters.
  • Filters should be changed after each remediation job.
  • If the indicator light is on, always change the CADPXS HEPA Filter.

APPLICATIONS

Water Damage
In this application, the Shield should be placed in the center of the affected area. The air scrubber will draw in the air, filter it, then blow out the newly cleaned air. To begin the process, simply turn on the scrubber and it will start cleaning the air. Keep in mind that if you are working in a large area or one divided by walls, you may need several air scrubbers to effectively clean the air.

Odor Control
The Shield 550, when used with the CADPXS HEPA Filter, is excellent at odor control, as well. Simply place the carbon filter in the pre-filter slot and it will capture a wide variety of odor-causing gas molecules, such as volatile organic compounds (VOC’s), smoke, soot, and paint fumes.

Other Uses
The Shield is also useful in many other applications including mold remediation, fire damage, dust control, and sewage remediation.

WARNING! Breathing Hazard

  • When using the CADPXS Shield 550 in a containment area, always turn off power to open combustion appliances, such as fireplaces, furnaces, water heaters, and CADPXS systems, to avoid the risk of backdating carbon monoxide fumes.
  • If the Filter Change Light illuminates during the remediation process, immediately change the CADPXS HEPA Filter. Tipping Hazard
  • Use caution when stacking units.
  • Fang equipment duo cause oldy of each other.

SAFETY NOTES

  • Always unplug the unit prior to performing any maintenance.
  • Check the power cord for damage (fraying, cuts, etc.) before use.
  • Verify that the GFCI outlet is working by powering on the machine and pressing the red GFCl test button. If the outlet is working, the “reset” button will pop up. To operate, press the reset button again.
  • To avoid electric shock, never use a water hose or pressure washer to clean the electrical components.
  • Check the pre-filter prior to operating the machine to ensure it is not clogged. If there is any sign of air flow restriction change the filter.
  • Make sure the unit is dry prior to installing clean filters.
  • When using the Shield for remediation purposes, replace both filters at the same time and always clean machine in between jobs. This will help prevent cross contamination.

IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is required.

LIMITED WARRANTY

This limited warranty starts from the date of purchase. CADPXS warrants to the original purchaser that this CADPXS product is free from manufacturing defects in material or workmanship for the limited warranty period of

  • Six (6) Month parts and labor. This includes the shipments charges for replacement parts or units. One (1) year parts and labor. The shipment fee to send the unit back to the manufacturer is not covered.
  • Ten (10) years. Polyethylene body ONLY.
  • This limited warranty is valid only on products purchased from the manufacturer or CADPXS authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. CADPXS Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
  • To receive warranty service, the purchaser must contact CADPXS at (888)928-1380 or support@cadpxs.com. Proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of CADPXS.

Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in a normal household, commercial or noncommercial use of this product and shall not cover the following

  • Damage occurs in uses for which this product was not intended for.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes. Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature. Damage
  • caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.
  • Damaged caused by not using the required filters for operation. (Pre-filter, HEPA & Activated Carbon Filter)
  • Damaged caused by using in a high humidity environment (75% or higher).
  • Damaged caused by using next to combustible materials/equipment that may or may not produce carbon monoxide.