LUMINOUS Zolt 1700 Pure Sine Wave 1500VA 24V Inverter User Manual

June 14, 2024
LUMINOUS

LUMINOUS Zolt 1700 Pure Sine Wave 1500VA 24V Inverter

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -product
image

Dear Customer, thank you for buying the LUMINOUS ZOL T V2 Sine Wave UPS. Welcome to the ever-increasing family of satisfied LUMINOUS users. This product provides you uninterrupted and reliable power in case of power failure. Please read the instructions carefully and thoroughly before using this product. This manual will facilitate you to not only understand the basic working of the LUMINOUS UPS but will also facilitate the ease of its maintenance and use.

SAFETY INSTRUCTIONS GUIDELINES

please go through these guidelines before connecting UPS.
This manual contains important safety and operating instructions. Read and keep the manual for future reference.

  • Before installing and using this device, read all instructions located in ( or on) this manual.
  • There are no user serviceable parts ins,de the UPS. Do not dis­assemble or attempt to repair.
  • The unit contains more than one live circuit (mains and batteries). Power may be present at more than one source.
  • In case of any emergency, use the front panel switch to switch off the UPS and disconnect the mains power cord & remove one battery connector.
  • Mount the unit indoors. Prevent exposure to the elements and do not allow water to enter the UPS.
  • While installing the unit, make sure that UPS power switch is OFF.
  • Always connect UPS to a 230V, 3-pin type mains socket with earthing. Connection to any other type of socket may result in a shock.
  • To reduce the risk of electrical shock, disconnect all power source from the UPS before attempting any maintenance cleaning or working on any circuit.

Do’s and Don’ts

Do’s related to UPS

  • ✓ Unplug and switch off the UPS before touching or cleaning the surfaces.
  • ✓ Unplug the UPS from the wall outlet during a lightening storm.

Don’ts related to UPS

  • X Don’t block the ventilation slots by cloth or other material, it may result in fire hazard.
  • X Don’t place the UPS near radiation or heat source.
  • X Don’t install the UPS near kitchen sink, laundry, wash bowl, bath tub.

Do’s related to battery

  • ✓Wear safety gloves and goggles.
  • ✓ Use D.M. water only for battery refilling.
  • ✓ Install battery in proper ventilated area.
  • ✓ Apply petroleum jelly to terminals of batteries.
  • ✓ Place battery horizontally & handle with care. v Keep out of reach of children.
  • ✓ Connect correct polarity of wires from UPS with battery.

Don’ts related to battery

  • x Don’t add impure or mineral water 1n battery.
  • X Don’t add acid to the battery as it can cause damage.
  • X Don’t keep near a moisture area or in direct sunlight.
  • X Don’t keep the cell caps loose or open.
  • X Don’t increase the length of battery wire.
  • X Don’t place the battery at height.
  • X Never short the terminals of the battery.
  • x Don’t over fill the battery cells.
  • x Keep away flammable things from the battery.
  • x Don’t dispose of batteries in fire.
  • x Don’t open or mutilate batteries.
  • x Don’t keep tools or metal parts on top of batteries.

PRODUCT DESCRIPTION

LUMINOUS ZOL T V2 Sine Wave UPS provides grid quality back-up power to the load and home appliances when there is a power failure. Normally, the UPS operates on mains, delivering power to the load. When the mains power fails, the load automatically transfers to UPS. The load is automatically transferred back to mains when it restores and charging is commenced to keep the battery at optimal level.

The ZOL T V2 is equipped with a number of outstanding features such as:

  • Provides grid quality sine wave.
  • Intelligent back-up and battery management system-
  • Automatically learns the battery capacity (Charge & Discharge cycle)­
  • Highly efficient and equipped with in-built protections.

PHYSICAL DESCRIPTION

This section describes the front panel and back panel of the UPS. Front Panel: It contains the LCD display and power switch.

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(1\)

  1. Power switch: This switch is for output power ON/OFF. If the switch is OFF, the UPS will not work. If the switch is ON, UPS will work (power LED will glow indicating UPS ON).
  2. LCD Display: It displays & indicates the various status of the UPS.

Display and Visual Indications: LUMINOUS -Zolt -1700 -Pure -Sine -Wave
-1500VA -24V -Inverter -fig \(2\)

  1. Mains ON : Glows when mains input is available.
  2. Mode Selector : Displays the UPS status on ECO mode.
  3. Fault Indicator : Glows in case of any fault.
  4. Battery Charge Indicator : Displays the battery charge level.
  5. Status Display : Displays the following parameters:
    • Battery charge and discharge time. (in Hours & Minutes)
    • Battery type – Tubular, Flat & SMF
    • Faults & Protections

Audio Indications:
There is a buzzer sound for the following parameters & stage of UPS:

  • Battery low pre-alarm & battery low· Overload · Over temperature
  • Wrong wiring · Short circuit

DISPLAY DESCRIPTION

  1. Mains ON : When mains input is available, then the respective symbol will glow.

  2. Mode Selector : When UPS is working in ECO mode, this symbol will glow.

  3. Fault Indicator : When any fault is there, this symbol will glow.

  4. Battery Charge Indicator It shows the different level of battery charge status. As per battery charge level, the bar strength increases or decreases. Bar rolls down intermittently as per load applied.

  5. Status Display : When battery is connected, the selected battery icon is shown for some time i.e., TUB, FLA or SMF. Next, it displays the charge and dis-charge time i.e., the remaining or  backup time for charging & discharging respectively. (Max time limit – 9Hrs  59M1n) it indicates the following parameters:

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(8\)

Note : In low battery, display will OFF after 5 minutes. Display will get reset/ON, when there 1s mains supply or by resetting the power switch.
At full charge, display LCD gets OFF when power switch is made OFF.
BACK PANEL: It contains many components 1.e., switch, socket, MCB, Fan and connector.

  1. LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig \(9\) Battery Selector: This switch selects as per battery type LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig \(10\)
  2. Mode Selector : This switch selects as per the UPS/REG or ECO mode. UPS/REG mode is selected when computer is to be run. LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig \(11\)By default, unit is in ECO mode when battery is reset.
  3. Output: Socket to connect the output of UPS to load
  4. Input MCB: Provided to connect the input mains.
  5. Normal/By-pass Mode Switch: Provided to by pass the mains. LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig \(12\)
  6. AC input: The mains input cord is connected at this point
  7. Battery (-ve): The battery negative lead is connected at this point.
  8. Fan: The assembly for fan.
  9. Battery ( +ve): The battery positive lead is connected at this point.
  10. Battery Charging Selection’ : This switch should be selected as per connected battery capacity. Please refer the below table for selecting the switch position (Only in ZOL T 1700V2).

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(13\)

INSTALLATION AND OPERATION

For the integrity of the installation, please review all the safety precautions mentioned in this manual before installation process. Observe all the warnings and labels on the equipment Do not try to install the system yourself. Only a trained LUMINOUS engineer is authorized to install the system. If the system is found tampered by any unauthorized person, the warranty would expire immediately.

Unpacking and Inspection

  • Check the condition of packaging box before unpacking the unit
  • Check the warranty card and product manual inside the box
  • Check the physical damage of the system during transit
  • In case of any damage or any problem, inform the concerned engineer

Placement

  • Place unit on smooth surf ace 1n clean. dry and well-ventilated area

STEPSFORUPSINSTALLATION:

  • To be done by a competent & knowledgeable person.
  • Switch OFF the supply to the distribution point to which the UPS 1s to be connected.
  • Check the building wiring. Improper wiring will not prevent the UPS from operating but will limit its protection capability. Improper building wiring could result 1n equipment damage that is not covered 1n warranty.
  • Connect the battery/batteries to UPS as per its correct polarity.
  • Keep the front switch of UPS in OFF position.
  • Keep input MCB in OFF and by-pass switch in normal position
  • Switch ON the front switch & measure the output voltage at output socket, it should be as per specification & switch off the UPS.
  • Connect the Load wire to the line point (right hole) of output plug & insert the output plug into socket located on the rear panel of UPS.
  • Switch ON the front Switch of the UPS.
  • Gradually put the load on UPS.
  • Connect input plug to commercial mains socket in correct polarity. Note: Do not switch ON the UPS power switch if any fault is indicated. In case of CBL warning indication, correct the wiring, then switch ON the UPS power switch.

INSTALLATION DIAGRAMS

  1. BATTERY INSTALLATION
    CAUTION: Battery polarity must be checked before connections. Installation shall be done by qualified technician.

    • Take precautions while connecting the battery cable to the battery post. avoid short circuit by spanner etc.
    • Battery terminals and thimble etc., should be cleaned and properly fastened.
  2. C ONNECTION DIAGRAM OF UPS WI TH MAINS & BATTERY

a) ZOLT1100V2

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(14\)

b)ZOLT1700V2

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(15\)

IMPORTANT INSTRUCTION

Automatically learns the battery capacity:

  • Select the battery type (TUB, FLA or SMF) and mode (UPS/REG or ECO mode)
  • Charge battery to 100% (all battery bars glow permanently/ no blinking)
  • Discharge battery till display shows battery low indication (Lbt).
  • Now the system displays actual time remaining for charge/ discharge.

Note: Actu al/accurate value is achieved after 3 cycles (charge &discharge).

SPECIAL FEATURES

  • Intelligent battery management system that displays remaining time of charge and discharge as per load.
  • Intelligent back-up management that optimizes voltage regulation to increase back-up time if the mains cut is more.
  • Automatically learns battery capacity through charge/discharge cycle.

PROTECTION FEATURES

LUMINOUS ZOL T V2 SINE WAVE UPS is equipped with many in-built protections, which are as follows: (respective indication is shown on the display).

  1. Short-circuit: Protects against short circuits in the system.
  2. Overload Prevents both UPS & Battery from damage during an overload condition.
  3. Wrong wiring : Protects the system in case of wrong wiring connected at the output. Note that the UPS must not be switched ON in this case.
  4. Over-temperature : Prevents burn-outs due to excessive heating by shutting down the UPS in case of high temperature.
  5. Battery deep discharge : Protects battery from deep discharge & hence enhances life of the battery.

TROUBLESHOOTING

This section provides with troubleshooting tips to identify and solve most of the common problems that might occur.

PROBLEMS POSSIBLECAUSE(S) ACTIONRECOMMENDED
Mains supply is normal but…
  • Line plug is loose

|

  • Fit plug properly

a) mains indicator is OFF or|

  • Dead wall socket

|

  • Check socket

UPS is working on battery|

  • MCB Trip

|

  • Check MCB

b) the mains ON indicator is glowing but no output|

  • Mains input too
  • low or high
  • Loose output plug

|

  • Wait for mains to normalize
  • Fit plug properly

If the display is showing Battery Low (Lbt)|

  • Battery may be discharged

|

  • Recharge battery when mains is available

If the display is showing OVERLOAD (old)|

  • UPS tripped due to excess load

|

  • Reduce the load and reset the power switch

For any other problem, please contact our authorized service person.

WARRANTY

LUMINOUS POWER TECHNOLOGIES PVT.LTD. warrants it’s UPS to be free from defects in materials and workmanship. This obligation 1s limited to servicing any instrument or part returned to the authorized service centre for that purpose and to making good any parts thereof which shall, within the warranty period, be returned to the Company or authorized service centre under a written intimation and which to the Company’s satisfaction be found defective. The Company reserves the right to decide as to whether the repair work should be carried out 1n the Company’s serV1ce centre or at site or at any other place. The freight incurred for to and fro dispatch of the defective material will have to be borne by the customer and the transit risk for the material will rest with the purchaser. The warranty covers all parts and will last for a period of 24 months from the date of sale to consumer / dispatch of the instrument if used within its specifications. The warranty for the replaced components will lapse along with that of the main instrument. LUMINOUS POWER TECHNOLOGIES PVT. LTD. reserves the right to make changes in design and specifications without notice and without any obligation to install such changes on units previously supplied. In no event will the Company, that is LUMINOUS POWER TECHNOLOGI ES PVT.
LTD., its D stributors and/ or Dealers be hable for personal injury, damages to property, consequential or incidental damages or for any expenses incurred by the buyer or user, due to use or sale of UPSs sold by LUMINOUS POWER TECHNOLOGIES PVT. LTD. directly or through its authorized Distributors/ Dealers or any third party under any circumstances, whether based on tort or breach of contract claims or on any other basis, to the extent these damages may be disclaimed by law. Except as expressly provided herein, the Company
makes no warranties, and disclaims all warranties, representations and guarantees (whether expressly, implied or statutory), including, but not limited to, any implied merchantabihtyor fitness for a particular purpose. Until superseded otherwise or in contractual form, this warranty is made expressly in lieu of all other liabilities and obligations on part of LUMINOUS
POWER TECHNOLOGIES PVT. LTD. Title to the instrument passes to the buyer upon delivery to the common carrier.

The warranty of your UPS shall become null & void if: 

  • Our instruments are warranted solely against poor workmanship and use of faulty material resulting in da mage that may arise despite normal operation and usage of the appliance, as prescribed in the operating manual. This warranty does not cover any other aspect including defects arising by reasons of accidents, abuse, misuse. neglect, improper installation (if not undertaken by the company or its representative), fire, flood or other act of God or any other natural calamities. Consequences of any other un-authorized repairs done or
    carried out will have to be borne by the purchaser.

  • The problem of Thermal Circuit Breaker blown will not be included in the warranty of the product. The services given for the same will be a paid service.

  • This warranty is not valid if the serial number and/or warranty seal of the Luminous UPS has been deleted, defected or altered.

  • Any accessories (like battery, battery trolley, LED/LCD, plastic parts or any house hold goods etc.) connected to the instrument will not be covered under this warranty.

  • All disputes for and/ or in connection with the instrument or the warranty in respect thereof shall be subject to the exclusive jurisdiction of courts of Delhi only.

IMPORTANT:
In the event of an instrument requiring servicing at our authorized service center, the following procedure should be adopted.

  1. The instrument must be securely packed, preferably in , its original packing.
  2. The instrument should be despatched on Freight-prepaid basis duly insured.
  3. One of our Service/ Sales Executives should be informed of the Goods Receipt No. and date of dispatch along with the name of the carrier.
  4. Luminous reserve the right to charge the consignee for any damage incurred during tr ans it
  5. This warranty card should be kept intact as the same will be required along with the original invoice to process tile claim.

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(16\)

EQUIPMENT DETAILS AND INSPECTION

LUMINOUS -Zolt -1700 -Pure -Sine -Wave -1500VA -24V -Inverter -fig
\(18\)

SERVICE
In the unlikely event if you are facing a problem that has not been sorted out by troubleshooting, kindly adopt the following procedure: Complaints may be logged on our 24-hour service call-desk number 18001033039,
Customer Helpline Number :
Toll Free
Helpline : 1800 103 3039
[email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LUMINOUS User Manuals

Related Manuals