Berrcom JXB-178 Non Contact Infrared Forehead Thermometer User Manual

June 14, 2024
Berrcom

**Berrcom JXB-178 Non Contact Infrared Forehead Thermometer User Manual


**

NOTE:
You must read this instruction manual completely before use and follow all instructions. Keep the instructions for later use. You must check the device functions according to this instruction manual prior to each use and only use this device if it is in proper working condition.

INTENDED USE

The device is an infrared thermometer intended to measure forehead temperature of infants and adults without contacting human body. It can be used by consumers in household environment and doctor in clinic as reference.

WARNINGS AND PRECAUTIONS

  • Only use this thermometer once you have read and understood the instruction for use.

  • Only use this thermometer for the specific purpose described in the instruction manual. Any misuse wil void the warranty.

  • This thermometer may be used for professional purposes or for personal home use.

  • Using this thermometer is not a substitute for consulting a doctor and seeking medical assistance as needed. Do ot self-diagnose or self-medicate on the basis of a self-measurement without consulting your doctor and obtaining your doctor’s approval Specially, do not take any new medication or change the type and/or dosage of any existing medication without consulting your doctor and obtaining your doctor’s approval.

  • Children must not be allowed to use this thermometer. Medical device is not toy.

  • If this thermometer is stored in a location that is cooler or warmer than where it is being used, let it sit in the patient’s room for at least 30 minutes before taking the measurement.

  • After physical activity, a bath or spending time outdoors, wait approx. 30 minutes before you take a measurement on your forehead.

  • To ensure an accurate measurement, this device must only be used indoors when the ambient temperature range is between 50°F (10°C) and 104°F (40°C).

  • This thermometer must be kept in a clean, dry area.

  • Do not expose this thermometer to electric shocks.

  • Do not expose this thermometer to extreme temperature conditions of greater than 131°F (85°C) or less than -4°F (-20°C). « Do not use this thermometer in relative humidity higher than 85%.
    Do not expose the thermometer to direct sunlight, extremely high or low temperatures, dirt or dust.

  • Do not drop this thermometer.

  • DO NOT TOUCH THE GLASS OF THE INFRARED SENSOR WITH YOUR FINGERS AS IT IS EXTREMELY FRAGILE AND COULD CAUSE INJURY.

  • For leaning, follow the instructions in section IX Cleaning and maintenance.

  • Do not use this thermometer if it is damaged.

  • Do not open up this thermometer. It contains small parts which might be swallowed by children.

  • Do not expose the thermometer to water or other liquid, as it is not water resistant or waterproof.

  • If an error occurs if the device is damaged, DO NOT attempt to repair this device yourself, as this will void the warranty. Contact your dealer and only have repairs carried out by authorized service partners.

  • Remove the batteries if you do not wish to use the unit for an extended period of time. Otherwise there is a danger that the batteries may leak.

  • Keep the thermometer away from electromagnetic fields produced by objects such as microwave ovens, arc welders or induction heaters.

  • A control measurement using a conventional thermometer is recommended in the following cases:

  1. If the reading is surprisingly low.
  2. For new-born infants up to 100 days old.
  3. For children under three years of age who have a weakened immune system or who react unusually in the presence or absence of fever.
  4. If you are using the thermometer for the first time or want to familiarize yourself with it.

PRODUCT DESCRIPTION

Product Overview

  1. LCD display
  2. MODE button
  3.  button
  4. MEM  button
  5. Infrared sensor
  6. On/Scan button
  7. Battery compartment lid
Buttons Functions
MODE Set the measurement mode.
Tum on or off the beep.
MEM Display of the saved measurements.
On/scan Switch on the device.Measure temperature.

HOW TO USE YOUR NON-CONTACT INFRARED THERMOMETER

  1. Install 2 AA batteries according to instructions provided in Section VII.
  2. For the first time use after installing batteries, wait 10-15 minutes for the device to warm up and adjust to the room temperature.
  3. Press On/Scan button, place 1.2-2 in (3-5 cm) away from forehead, aim lens toward forehead. Make sure the measurement mode is ‘BODY”, press the thermometer’s On/Scan button, and the temperature will be displayed instantly.
  4. Before taking an individual’s temperature, make sure any hair, dirt or dust is removed from forehead and forehead is dry. Wait 10 minutes after such removal prior to measuring temperature.

For reliable results:

  • Do   NOT attempt to take an individual’s temperature by aiming the device at a body part other than the forehead (i.e. arms, legs, torso, etc.).
  • Do NOT move the thermometer before the final result is displayed.
  • Do NOT take an individual’s temperature near any drafts (i.e. wind, air conditioner, fans)
  • Do NOT take an individual’s temperature shortly after he or she participated in vigorous physical activity, bathed, took medicine, ate or drink, or had a cold or warm compress on his or her forehead.
  • Do NOT take an individual’s temperature when there has been a significant change in ambient conditions. Allow the device to adjust to a significant change in the ambient temperature due to a change in environment for 30 minutes before using the device.
  • Wait at least 3 to 5 seconds between measurements.
  • We recommend that you take three measurements on the forehead, and if the results of three measurements are different, use the one with the highest value.”

TURNING ON AND SETTING THE THERMOMETER

  1. Turning on the device. Press the “On/Scan” button. The display will illuminate, will enter the “Standby Mode™ and will display ~—°C” or -—°F”. Next, place the device 1.2-2 in (3-5 cm) away from the individual’s forehead, aim the sensor of the device toward the forehead, and press the “On/Scan” bution again, which will then take the individual’s temperature. The device will automatically shut off after 30

  2. seconds of non-use. Setting the MODE when the device is on
    a. Press “MODE” button, and the screen will display: Body…°F
    b. Press again “MODE” button and the screen will display: Room… °F
    c. Press again “MODE” button and the screen will display: Surface Temp…°F
    Note: The thermometer default is set to BODY mode.
    IMPORTANT
    The surface temperature differs from the body temperature. To obtain the body temperature must use the “BODY” mode. When measure the temperature of a baby-boltle or bath (by using the Surface Temp Mode), or room temperature (by using the Room Mode).

  3. Choosing the temperature unit
    When the device is on, Press “MODE” button for 2 seconds, the screen will display “F1”, then press “MODE” button to transfer between degree Celsius and Fahrenheit, Confirm by pressing “MEM” button.

  4. Alarm setup
    When the device is on, Press “MODE” button for 2 seconds, the screen will display “F1”, then press “MEM” button once, the screen will display “F2”, press “MODE” button to choose the alarming temperature from 99.1°F to 102.4°F (37.3°C to 39.1°C), Confirm by pressing “MEM” button.
    Note: The alarm threshold default value is 100.4°F (38°C)

  5. When the device is on. Press “MEM” (Memory) button, which will then display the last temperature, and allows for a view of the last 32 measurements. In the switch on state, Press “MEM” button and hold for 5 seconds, all data in memory will be deleted. Then press “MEM” button again, the display will show “CLr”

  6. When the device is on, press ” ” to turn the buzzer on or off.
    When the screen shows “ON”, the buzzer opened.
    When the screen shows “OFF”, the buzzer closed.

  7. Recalibrating the device using the F4 MENU
    Instructions for recalibration:
    When the device is on, Press “MODE” button for 2 seconds, the screenwill display “F1”, then press “MEM” button twice the screen will display “F4”, press “MODE button to choose the Offset value from -5.4°F to 5.4°F (-3°C to 3°C), Confirm by pressing “MEM” button.
    Recalibrate the device after any seasonal or environmental changes, when you are using the device on people of different skin tones, or when you believe the device is not measuring the same temperature as a mercury thermometer.

TECHNICAL SPECIFICATIONS

  1. Normal using condition
    Ambient temperature: 50°F 104°F (10°C -40°C)
    Relative humidity: less than 85%
    Pressure altitude: 700 hPa to 1060 hPa

  2. Storage and shipping condition
    Ambient temperature: -4°F 131°F (-20°C – 55°C)
    Relative humidity: less than 95%
    Pressure altitude: 700 hPa to 1060 hPa

  3. Batteries: DC 3V (2 pcs AA batteries)

  4. Unit size: approx. 155 x 100 x 40 mm (L x W x H)

  5. Unit weight (without battery): approx. 105g

  6. Temperature display resolution: 0.1°F (0.1°C)

  7. Measuring range:
    In body mode: 89.6°F 109.2°F (32.0°C – 42.9°C)
    Under body mode, there is three color backlits:
    Green color backlit: less than 99.1°F (37.3°C), means normal temperature.
    Orange color backlit: 99.3°F 100.2°F (37.4°C -37.9°C), means may be low fever.
    Red color backlit: more than 100.4°F (38°C), means may be high fever.
    In surface temp mode: 32°F 140°F (0°C -60°C)
    In room mode: 32°F 104°F (0°C -40°C)

  8. Accuracy:
    89.6°F — 94.8°F (32.0°C – 34.9°C) #0.6°F(0.3°C) 95°F — 107.6°F (35.0°C ~ 42.0°C) £0.4°F(20.2°C) 107.8°F — 109.2°F (42.1°C – 42.9°C) £0.6°F(x0.3°C)

  9. Consumption: less than 300mW

  10. Measuring distance: 1.2in 2in (3cm ~ 5cm)

  11. Automatic power-off: less than 30 secs

  12. Memory capacity: 32 readings

  13. Measuring site: Forehead

  14. Reference body site: Axilary

  15. Mode   of   operation: Adjusted mode

  16. Expiration date: The JXB-178 may last, butis not guaranteed, for up to 5 years from the date of the manufacturing

Note: In the BODY mode, the JXB-178 can take temperature readings below 89.6°F or above 109.2°F (32°C below or above 42.9°C), however, the temperature reading may be unreliable.

BATTERIES

CHANGING THE BATTERIES

When the battery symbol ” ” flashes on the LCD display screen, the batteries need to be changed.
To change the batteries, open the lid on the back of the device and ensure the batteries are positioned in the correct manner. Improperly installing the batteries could cause damage to the device. Do NOT use rechargeable batteries. Only use single-use batteries.

DISPOSING OF BATTERIES

To protect environment, dispose of empty batteries at appropriate collection sites according to national or local regulations.

Notes on haling batteries

  • If your skin or eyes come into contact with battery fluid, rinse the affected area with water and seek medical assistance.

  Chocking hazard! Small children may swallow and choke on batteries. Store batteries out of the reach of small children. Ida battery has leaked, put on protective gloves and clean the battery compartment with a dry cloth.

  • Protect batteries form excessive heat.

Risk of explosion! Do not throw batteries into a fire.

  • Use idetical or equivalent battery types only.
  • Always replace all batteries at the same time.
  • Do not use rechargeable batteries.
  • Do not disassemble, split or crush the batteries.

INCLUDED IN DELIVERY

Non-Contact Infrared Thermometer User Manual

CLEANING AND MAINTENANCE

  • Do not fragile and touch the glass of the infrared sensor with your fingers as it is extremely could cause injury. Protect it from dirt and damage. Clean the glass with ball that is lightly moistened with 95% Propyl Alcohol.
  • Cleaning needs to be done regularly as needed.
  • To clean the entire device, use soft cloth slightly dampened with mild soapy water or 70% is opropyl alcohol. Under no circumstances may liquid enter the thermometer.
  • Do not use the thermometer again unti itis completely dry and keep it stand stil at least 30 minutes.
  • Never use aggressive cleaning agents, thinners, benzine or tough brushes.

GUIDELINES

This device complies with the ISO 80601-2-56 and IEC60601-1-2 and is subject to particular precautions with regard to electromagnetic compatibility.

CLASSIFICATION

  1. Internally powered equipment;
  2. Type Bf applied part;
  3. IP22;
  4. Sterilization or disinfection: N/A;
  5. Category AP / APG equipment: N/A;
  6. Continuous operation;

TROUBLESHOOTING

If you have problems while using your thermometer, please refer to this guide to help resolve the problem. If the problem persists, please contact our customer service.

THE SCREEN DISPLAYS TEMPERATURE HIGHER THAN 109.2°F (42.9°C):
The temperature is in Fahrenheit. Change the measurement to Celsius.

THE SCREEN DISPLAYS TEMPERATURE LOWER THAN 89.6°F (32°C):
To take the surface temperature, press the “MODE” button and set to the reading called “Body”, If the device is in Surface Temp Mode, the 32°C (89.6°F) temperature displayed is showing the external temperature of your body, rather than the internal.

THE SCREEN DISPLAYS THE MESSAGE HI
When using the JXB-178 Thermometer, the message “HI” can show on the screen. In this case, the temperature is above the measurement range selected, either above 109.2°F (42.9°C) in Body Mode.

THE SCREEN DISPLAYS THE MESSAGE LO
When using the JXB-178 Thermometer, the message “LO” can show on the screen. In this case, the temperature analyzed is under the measuring range selected, either less than 89.6°F (32°C) in Body Mode.

This message displays for various reasons. Please find below a list of the main issues:

Reasons for LO message display Advice
Temperature reading hampered by hair or perspiration. Make sure there is no

obstruction or dampness prior to taking temperature.
Temperature hampered by an air draft or dramatic change in ambient temperature| Make sure there is no air blowing in the area of use; this could affect the infrared reading.
Temperature readings are too close together, and the thermometer did not have time to reboot.| Wait a minimum of 3 to 5 seconds between readings; a 15 second pause is recommended
The measuring distance is too far.| Hold the device 1.2-2 inches (3-5 cm) away from forehead.

SIGNS AND SYMBOLS

Symbol Description of symbol
Trade mark
Application part, Type BF
Direct current
IP22 Protected against access to hazardous parts with a finger and against

vertically falling water drops when enclosure filted up to 15°
| Refer to instruction manual / booklet
| DISPOSAL: Do not dispose this product as unsorted municipal waste.Collection of such waste separately for special treatment is necessary.
| Manufacturer
| Serial number
| This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
| Date of manufacture
| Model number
| Medical device
| Country of manufacture
| Unique device identifier

EMC DECLARATION

The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare and clinic environments.

Warning: Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances high.
Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
Warning: Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment JXB-178, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.

  1. All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life. Portable and mobile RF communication equipment may affect the performance of the JXB-178, avoiding strong electromagnetic interference when used, such as near mobile phones, microwave ovens, etc.
  2. Guidance and manufacturer’s declaration -electromagnetic emissions and Immunity

**Guidance and manufacturer’s declaration -electromagnetic emissions and

Immunity**

Table 1

Guidance and manufacturer’s declaration – electromagnetic emissions
Emissions test Compliance
RF emissions CISPR 11 Group 1
RF emissions CISPR 11 Class B
Harmonic emissions IEC 61000-3-2 Not application
Voltage fluctuations/ flicker emissionsIEC 61000-3-3 Not application

Table 2

Electrostatic discharge (ESD)IEC 61000-4-2| ±8 kV contact±2 kV. 34 kV. ±8 kV. 315 kV air| ±8 kV contact±2 kV, ±4 kV,18 kV, 315 kV air
---|---|---
Electrical fast transient/burst IEC 610004-4| Not application| Not application
SurgeIEC 610004-5| Not application| Not application
Voltage dips, short interruptions and voltage variations on power Supply input linesIEC 61000-4-11| Not application| Not application
Power frequency magnetic fieldIEC 61000-4-8| 30 Alm 50H7J60Hz| 30 A/m 501-lz/60Hz
Conduced RF
IEC61000-4-6| Not application| Not application
Radiated RF IEC61000-4-3| 10 V/m80 MHz — 2,7 GHz 80 %AM at 1 kHz| 10 V/m80 MHz — 2,7 GHz 80 % AM at 1 kHz
NOTE UT is the a.c mians voltage prior to application of the test level.

FCC DECLARATION

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

WARRANTY/SERVICE

In accordance with our policy of continued product improvement  and subject to the regulations and rules, we reserve the right to make technical and optical a adjustments without notice. Warranty and repair terms

Please contact your dealer or the service centre in case of a claim under the warranty. If you have to return the thermometer, please enclose a copy of your receipt and state what the defect is.

The following warranty terms apply:

  1. The warranty period for your product is 18 months from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.

  2. Defects in material or workmanship will be removed free of charge within the warranty period.

  3. Repairs under warranty do not extend the warranty period either for the thermometer or for the replacement parts.

  4. The following is excluded under the warranty:
    a. All damage which has arisen due to improper treatment, e.g. nonobservance of
    the user instructions.
    b. All damage which is due to repairs or tampering by the customer or unauthorized third parties.
    c. Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service center.
    d. Accessories which are subject to normal wear and tear.

  5. Liability for direct or indirect consequential losses caused by the thermometer are excluded even if the damage to the thermometer is accepted as a warranty claim.

  • GUANGZHOU COMBER MEDICAL DEVICE CO., LTD. EXPRESSLY DISCLAIMS ALL WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
  • UNDER NO CIRCUMSTANCES SHALL BERR COM HAVE ANY OBLIGATION OR LIABILITY FOR ANY LOSS OF PROFIT OR FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONTINGENT DAMAGES WHATSOEVER WITH RESPECT TO CLAIMS MADE BY ANY CUSTOMER, CONSUMER OR OTHER USER OF BERR COM PRODUCTS.
  • IN THE EVENT THAT ANY APPLICABLE LAWS IMPOSE WARRANTIES, CONDITIONS, OR OBLIGATIONS THAT CANNOT BE EXCLUDED OR MODIFIED, THIS PARAGRAPH SHALL APPLY TO THE GREATEST EXTENT ALLOWED BY SUCH LAWS.

Guangzhou Berrcom Medical Device Co., Ltd
Address: No.38 Huanzhen Xi Road, Dagang Town,
Nansha, Guangzhou Guangdong, CHINA 511470
Tel: +86(20)34938449
Email: service@berrcom.com

Symbols
Symbols

Berrcom Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals