Introduction
This manual is intended to assist the user with the Bluevolt R-Type UPS Power System. Th systems can be used as follows:
- plug-and-play backup energy with uninterruptible power supply (UPS)
- hardwired into the mains distribution board of a home or business to power energy efficient lighting and small appliances
In the first case, the manual is helpful to understand the display on top of
the unit.
In the second case, or when solar panels (PV modules) are connected, this
manual describes the procedures to install and commission the power system.
This manual covers information that is relevant to the installation and
commissioning of the power system and omits detailed information about the
inner workings of the system that is irrelevant for these steps.
Product Description
Bluevolt power systems are available in a number of sizes with energy storage
ranging from 1.2 kWh to 12 kWh. Larger systems are manufactured by Bluevolt
according to the project requirements.
This manual covers the Bluevolt R-Type UPS Power System.
The Bluevolt R-Type system is designed to be placed on the floor. It is light
enough to be lifted easily by 1-2 people.
The system is designed to be plug-and-play. It can simply be plugged into any
wall socket t r charge. Plug your devices into the R-Type’s built-in plug
socket to enjoy uninterrupted powe through load shedding.
The display in the top face of the device shows the device status. The display
shows information including whether the unit has mains power, whether it is
charging and what percentage of the maximum power it is generating. You can
also scroll through the menu to see more detailed information such as battery
voltage and power consumption.
- Display
- Handle
- Plug socket switch
- Plug socket – AC output
- Battery discharge control switch
- Plug for AC input
- Inverter AC circuit on switch covered by rotating flap
- DC bus – XT60 connector (negative)
- DC bus – XT60 connector (positive) – fused at (13) with 2x 10A blade fuses = 20A DC
- Kensington slot for anti-theft cable lock
- PV fuse for MC4 connectors (14, 15)
- Fuse – AC output – 6A Fast Blow fuse ONLY
- Fuses (two) – blade fuses for XT60 connector (8, 9)
- MC4 connector – to positive PV input – fused at (11) 32A DC
- MC4 connector – to negative PV input
Table 2.1 Bluevolt R-Type Technical Details
Inverter Output | Rated Power | 1,000 W |
---|---|---|
Surge Rating | 2,000 W for 5 seconds | |
Waveform | Pure sine wave | |
Rated output voltage | 230 VAC ±3% | |
Efficiency | 90% | |
Working temperature | 0-40 °C | |
Output frequency | 50 Hz | |
Transfer time | 10-20 ms | |
Overcurrent Protection | AC Output Fuse | 6 A Fast Blow |
Inverter | Automatic shutdown | |
BMS | Electronic circuit breaker | |
Battery | Battery chemistry | Lithium iron phosphate |
Nominal voltage | 12.8 V | |
Energy storage capacity | 220 Ah | |
Energy storage capacity | Standard: 2,800 Wh | |
Protection | High voltage, low voltage | |
Depth of discharge | 95% maximum | |
Cell type | Prismatic | |
Charging system | Charging voltages | Bulk 14.6 V Float 14.0 V |
Charging current max | 20 A | |
Mechanical specifications | Dimensions | L 540 x W 290 x H 310 mm |
Weight | 38 kg | |
Miscellaneous | Warranty | Battery: 5 years Other components: 1 year |
Active Cooling | Intelligent fan control | |
Colour | Black (or custom colour) |
General Operating Notes
3.1. Input Power
Leave the unit plugged into the wall as this will ensure that the batteries
are fully charged for the next power cut.
Avoid leaving the unit at a low state of charge for prolonged periods as this
will cause the battery to disconnect from the inverter. If this happens,
follow the procedure in the troubleshooting section.
3.2. Storage
Ensure that the unit is fully charged before storing for a maximum of 2
months. Shutdown the power system by switching the battery off using switch
(5), as shown in Figure 2.1 Labelled image of Bluevolt R-Type.
Human Interface
Please refer to the inverter manual section below.
Please note that tampering with the settings will void the warranty.
Adjustment of the solar related settings is permitted by a suitably qualified
person only.
Connecting Solar Panels (PV Modules)
For the purpose of incorporating solar panels into your power configuration,
it is strongly recommended to engage the services of a professional solar
power system installer. The user manual for the inverter-charger, contained
within the second part of this document, provides a thorough set of
guidelines regarding solar panel compatibility.
Solar input integration is achieved through the use of MC4 connectors, which
are clearly marked as items (14) and (15) in Figure 2.2, titled “Labelled
image of Bluevolt R-Type”.
Please note that these MC4 connectors are equipped with a 32 A fuse as a
safety measure.
It is of the utmost importance that the design and installation procedures are
exclusively carried out by qualified and certified photovoltaic/solar panel
installers. This is a requirement for ensuring both optimal performance and
adherence to safety standards.
Troubleshooting
Refer to the inverter manual and the list of fault codes that could be shown
on the display.
You can contact your distributor or installer reseller for assistance.
6.1. Common Errors and Recovery Procedures
No power at AC output
Fault description: There is no power at the AC output
Error details: Likely to be inverter overload or blown fuse Recovery
Procedure:
-
Switch OFF the inverter switch (7) and switch it back ON.
-
If the error is not resolved after following step one then switch OFF the inverter switch (7) a second time and leave it in the OFF position.
-
Unplug the unit from the wall socket (6)
-
Unscrew the AC output fuse holder (12) – NB ensure steps 2 and 3 have been followed for safety reasons.
-
If the fuse is blown, then replace it with a 6A Fast Blow fuse ONLY. Installing the incorrect fuse could damage internal circuits.
-
If power to the AC output is still OFF please contact your reseller about a damage assessment.
Possible causes if fault persists: Special reset procedures required or the unit has been damaged internally.
Constant beeping with display flashing
Fault description: Constant beeping with display flashing
Error details: The inverter cannot detect the battery.
Recovery Procedure: -
First try turning the battery on using the switch shown by (6) in Figure 2.1 Labelled image of Bluevolt R-Type.
-
If the switch does not resolve the fault, please contact Bluevolt for further instructions.
Possible causes if fault persists: the inverter Low DC cut-off voltage setting has been tampered with, or the power system has been stored at a low state of charge for an extended period.
Transport
7.1. Shipping
The Bluevolt R-Type units are packed in a box with layers of protective
material.
Ensure that the box stays upright.
The box is easily lifted by one or two people.
7.2. General transport
The power system should be completely shut down for transport as the cooling
vents may become obstructed when packed close to other items. Refer to
labeller images Figure 2.1 and Figure 2.2 and follow these steps:
- Unplug from the wall outlet (6)
- Turn off the inverter using the switch indicated by (7)
- Turn off the battery using the switch indicated by (5)
Ensure that the display (1) is protected from damage.
Environmental requirements
8.1. Indoor use
Bluevolt batteries and power systems are designed strictly for indoor use.
Keep out of direct sunlight and away from moisture.
8.2. Ventilation
Bluevolt power systems emit no harmful gases, which means that specific
venting is not needed.
The system is fan-cooled and the vents should be unobstructed to ensure that
cooling air can move freely.
The vents should never be covered as this will cause the unit to overheat.
Keep a minimum of 20 cm of free air around the Bluevolt R-Type power system to
ensure that air can move freely through the vents.
8.3. Ambient temperature
The power should be operated between 0˚C to 30˚C. If the temperature regularly
exceeds 40˚C, cooling is recommended to extend the service life of the
battery.
Charging of the battery is blocked below 0˚C to avoid damage to the battery
The power system should remain 500mm away from any heat source at all times.
Switching on the Bluevolt R-Type Power System
To switch on the power system refer to Figure 2.1 Labelled image of Bluevolt R-Type and:
- Switch on the battery (5)
- Take the plug (6) and plug into a wall outlet
- Switch on the inverter (7)
- Observe the display to confirm that the battery begins charging as shown by Figure 10.1, below.
LCD display
Charging by utility and PV energy. Charging by utility Charging by PV energy.
Figure 10.1 Power System Charging
The power system must be switched off (5) fully when not in use. This will prevent self-discharge. Refer to Figure 2.1 Labelled image of Bluevolt R-Type and:
- Turn off the inverter (7)
- Turn off the battery (5)
It is normal for the unit to charge even though the battery discharge switch (5) is in the OFF position, and the unit is plugged (6) into a wall outlet.
Warranty and Repair
Please refer to the warranty document for the Bluevolt Link CAN Bus Controller.
Expected Product Life
The Bluevolt R-Type system battery is expected to have a useful life of 15+
years with daily cycling and an average of 80% DoD.
For the longest possible battery life and thus lowest lifetime cost per kWh,
you can limit the average DoD to 50-60%, keep the ambient temperature around
10˚C to 20˚C, and avoid overloading the unit.
To maximize the life of the inverter, turn it off when not in use for long
periods using the switch indicated by (5) in Figure 2.1 Labelled image of
Bluevolt R-Type.
Inverter-Charger Manual
What follows is the user manual for the inverter-charger inside the Bluevolt
R-Type UPS Power System.
Connection of the power system to a mains distribution board is to be done
only by a suitably qualified and experienced installer of inverters.
For the user there is information in this manual about operating and
understanding the display on top of the Bluevolt R-Type.
North End
GQEBERHA
041 484 3770| Newton Park
GQEBERHA
041 364 3029| de Mist
KARIEGA
041 992 1688| Oranjesig
BLOEMFONTEIN
051 430 8722
---|---|---|---
Documents / Resources
|
Kariba R-Type UPS Power
System
[pdf] User Manual
UPS-BV-R-KARIBA1, R-Type UPS Power System, R-Type, UPS Power System, Power
System, UPS, UPS R-Type
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>