American Dryer AD90-SS Advantage AD Automatic Hand Dryer Instructions

June 13, 2024
American Dryer

EXTREMEAIR SENSOR REPLACEMENT INSTRUCTIONS
GXT6, GXT8, EXT2, AND EXT4 SERIES ONLY

AD90-SS Advantage AD Automatic Hand Dryer

WARNING: DISCONNECT POWER BEFORE INSTALLING
WARNING: CANCER AND REPRODUCTIVE HARM ­ www.p65warnings.ca.gov

Service of a hand dryer should be performed by a licensed electrician.

  1. After disconnecting power, remove the cover by loosening the two tamper-resistant screws with the security wrench provided with the dryer.
  2. Carefully unplug the four electrical connectors that plug into the sensor and disconnect the two lead wires from the power supply. Make a note of which wire goes to which terminal.
  3. Carefully remove the nozzle assembly from the blower housing by removing the four screws.
  4. Remove the sensor from the backplate by removing the single mounting screw.
  5. Install the new sensor by attaching to the backplate with the mounting screw, position sensor as high as possible. Reconnect the four electrical connectors and the power supply, replace the nozzle assembly and cover.
  6. After checking the wiring, apply power and test. INCREASE sensitivity (Figure 2) by using a flatblade screwdriver and CAREFULLY turning the adjustment pot located on the sensor CLOCKWISE 1/3 turn MAX. DECREASE sensitivity, turn COUNTERCLOCKWISE 1/3 Turn MAX.

GX SERIES SENSOR REPLACEMENT INSTRUCTIONS

WARNING: DISCONNECT POWER BEFORE INSTALLING
WARNING: CANCER AND REPRODUCTIVE HARM ­ www.p65warnings.ca.gov

Service of a hand dryer should be performed by a licensed electrician.

  1. After disconnecting power, remove the cover by loosening the two tamper-resistant screws with the security wrench provided with the dryer.
  2. Carefully unplug the four electrical connectors that plug into the sensor and disconnect the two lead wires from the power supply. Make a note of which wire goes to which terminal.
  3. Carefully remove the nozzle assembly from the blower housing by removing the four screws.
  4. Remove the sensor from the backplate by removing the single mounting screw.
  5. Install the new sensor by attaching to the backplate with the mounting screw, position sensor as high as possible. Reconnect the four electrical connectors and the power supply, replace the nozzle assembly and cover.
  6. After checking the wiring, apply power and test. INCREASE sensitivity (Figure 2) by using a flatblade screwdriver and CAREFULLY turning the adjustment pot located on the sensor CLOCKWISE 1/3 turn MAX. DECREASE sensitivity, turn COUNTERCLOCKWISE 1/3 Turn MAX.

American Dryer AD90 SS Advantage AD Automatic Hand Dryer - Product Overview
2

American Dryer, Inc. • 340 County Line Road, Bensenville, IL 60106 U.S.A.
PH 734-421-2400www.americandryer.com • Revised June 2018