electriQ SILENT10 Portable Air Conditioner User Manual
- June 13, 2024
- ElectriQ
Table of Contents
- electriQ SILENT10 Portable Air Conditioner
- Product Information
- Product Usage Instructions
- SAFETY INSTRUCTIONS
- FEATURES AND PARTS LIST
- Parts list
- Accessories
- INSTALLATION
- Important safeguards
- OPERATION AND SETTINGS
- **Control instruction
- WATER-DRAINAGE
- Maintenance
- Troubleshooting
- APPENDIX
- TECHNICAL DATA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
electriQ SILENT10 Portable Air Conditioner
Product Information
The Silent10 Portable Air Conditioner is an innovative air conditioner designed by ElectriQ. It is a portable unit that can easily be moved from one room to another. The air conditioner comes with various features and parts to ensure efficient cooling and ease of use.
Features
- Control Panel
- Air Outlet
- Fan Blade
- Castors
- Upper Filter Frame
- Exhaust Connector
- Lower Filter Frame
- Rubber Stopper
- Drain Plug Cap
- Power Cord
- Extendable Window Kit
- Screw, Washer, Nut (for window kit)
- Extendable Exhaust Hose (~1.5m)
- Hose Connector
- Remote Control
Product Usage Instructions
Installation
- Before using the unit, keep it upright for at least 3-4 hours.
- To assemble the fishtail connector on the hose:
- Extend one head of the hose and screw it into the unit anti-clockwise. The hose can be removed by screwing it clockwise.
- Connect the hose to the assembled adaptor by screwing it in place anti-clockwise.
- Install the window kit:
- Partially open the window.
- Fix the window kit to the window.
- Ensure the unit is upright and there are no obstructions to the air inlets and outlet grills.
- Fix the other end of the hose to the air-outlet window kit.
Note : The window kit is designed for sliding or sash windows or doors. The fishtail adaptor can be used with most windows/doors. When using the cooling mode, ensure that the opening left is as small as possible. The best form of installation is through a wall duct to properly vent hot air from your room while efficiently cooling it.
Important Safeguards
- The length of the soft hose extends from 28 cm to 150 cm. Do not extend the hose beyond this length to avoid unit malfunction and warranty invalidation.
- Ensure the outlet vent is well-ventilated and not obstructed to prevent unit overheating.
- Avoid bending the air hose more than 30 degrees.
Thank you for choosing ElectriQ
Please read this user manual before using this innovative Air Conditioner and
keep it safe for future reference. Visit our page
www.electriQ.co.uk for our entire range of
Intelligent Electricals
SAFETY INSTRUCTIONS
Important!
-
Carefully read the instructions before operating the unit
-
This appliance is for indoor use only.
-
Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
-
Installation must be in accordance with the regulations of the country where the unit is used.
-
If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
-
This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
-
Disconnect the power plug from the socket before dismantling, assembling or cleaning.
-
Avoid touching any moving parts of the appliance.
Never insert fingers, pencils, or any other objects though the guard -
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance.
-
Do not clean the unit by spraying it or immersing it in water.
-
Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
-
Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges.
-
A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
-
Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
-
Do not use the appliance for any other purposes than its intended use.
-
The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
-
Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off
This prevents damage to the compressor. -
Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel.
-
Always place the unit on a dry and stable surface.
-
The appliance should not be installed in laundry or wet rooms
Energy Saving and Unit Safety Protection Tips
- Do not cover or restrict the airflow from the outlet or inlet grills.
- For maximum performance, the minimum distance from a wall or objects should be 50cm.
- Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality.
- For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting.
- To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35C.
FEATURES AND PARTS LIST
Features
- Self-evaporative system – no external water tank needed
- Designer inspired luxury model
- Bright LED screen, indicates temperature and operation mode
- On/Off timer function – allows you to choose when the unit operates
- Compressor protection technology
Parts list
- Control Panel
- Air Outlet
- Fan Blade
- Castors
- Upper Filter Frame
- Exhaust Connector
- Lower Filter Frame
- Rubber Stopper
- Drain Plug Cap
- Power Cord
Accessories
- Extendable Window Kit
- Screw, Washer, Nut (for window kit)
- Extendable Exhaust Hose (~1.5m)
- Hose Connector
- Remote control
INSTALLATION
Installation
Warning Before using this unit, please keep it upright for at least 3-4
hours.
This unit can easily be moved from one room to another.
While moving the unit please note that it must always be kept upright and then
placed on an even surface.
-
Assemble the fishtail connector on to the hose
-
Assemble the exhaust hose to the air conditioner body Extend one head of the hose and screw it into the unit anti-clockwise. The hose can be removed by screwing the hose clockwise.
Note : to screw it into place should take no less than three rotations. -
In the same way connect the hose to the assembled adaptor (at least three rotations)
-
Installation of window kits:
Partially open the window and then fix the window kit to the window -
Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills
-
Fix the other end of the hose to the air-outlet window kit
Note : The window kit is only designed to be installed with sliding or
sash windows or doors. The window kit is not designed or to be used with any
other style of windows. However, the fish tail adaptor can be used with most
windows/doors.
When using the cooling mode ensure that the opening left is as small as
possible.
The best form of installation is through a wall duct. By properly venting you
expel hot air from your room while efficiently cooling it.
Important safeguards
The length of the soft hose extends from 28 cm to 150 cm. If the hose is extended above this length the unit may malfunction and this can invalidate the warranty. The outlet vent must be well-ventilated and not obstructed as this will cause the unit to overheat. Avoid bending the air hose more than 30 degrees.
OPERATION AND SETTINGS
- This portable air conditioner boasts 3 functions: cooling, dehumidifying, and fan.
- The fan has two speeds: high and low. Temperature range settings are: 16-31C
- The unit will also display operating function, temperature, fault diagnostic, and protective functions on the LCD screen.
**Control instruction
**
Control panel
-
When plugged in the unit is automatically in standby status.
-
ON/OFF button: Press this button to turn the unit on and enter cooling mode.
The unit will be turned to cooling mode preset to 22C target temperature. Press again and the unit will switch off. -
Mode button
Press this key to choose the Cooling Fan or Dehumidifying Mode. -
Fan button
a) In Fan and Cooling mode:
HIGH LOW ) In Dehumidifying mode, the fan is auto-set to low speed and cannot be changed -
Timer
Press the icon to select your desired operating times.
Use the buttons to adjust hours from 1-24.
You can only set the auto-shut-off timer while the unit is operating (on)
You can only set the auto-start timer while the unit is switched off (standby)
After you have set the timer the timer will initiate and the units will start/ stop
after the selected time. If you adjust the timer or press the power key previous
settings will be cleared. Timer functions cannot be combined or repeated. -
Up and Down button: set temperature and timer.
In cooling mode, the temperature can range from 16 – 31C. The timer is 1-24 hrs.
Pressing and buttons simultaneously, shift between C and F. -
Sleep mode key :
In cooling mode, press the key and the unit will go into sleeping mode.
Press again to cancel.
It increases the target temperature by 1C after an hour and readjusts to 2C
increase after 2 hours. Sleep mode is not operational under dehumidification and fan-only mode. -
Swing button : press this key to start the auto swing function left to right, and press again to cancel. Stopping the swing will lock the position of the louvres.
Remote control
- Power Press this key to turn the unit on/off.
- Timer Press this key to set the time. Once set, the selected time will flash 5 times as confirmation
- Down Press this key to turn down the temperature or adjust the time.
- Mode Press this key to choose cooling, heating, dehumidifying or fan mode
- Up Press, this key to turn up the temperature or adjust the time.
- Fan Press this key to set low/medium/high fan speed.
- Sleep Only in cooling function Press this key to enable sleep mode.
- Swing Press this key to control the swing function.
Multi protective function
-
Anti-freezing protecting control:
When the ambient temperature is low while in Cooling Mode, the compressor and water motor will stop working if the copper coil temperature reaches <2C for over 20 seconds. When the copper coil temperature increases to >8C, the protection will be stopped automatically. -
Water-full protection:
When the water level in the internal water tank surpasses the maximum level, the unit will alert automatically and the main led light will flash. Please discharge water in the machine according to the “Water Drainage” section -
Compressor delay-protection
Except for the first power-on, the compressor can start instantly.
The compressor also runs under a 3-minute delay protection function. -
Compressor protection
In cooling, dehumidifying and heating mode, if the temperature difference between the coil temperature and room temperature is less than 3?C, for more than 30 minutes, the machine will enter ‘no refrigerant’ compressor protection mode.
The compressor and water spring motor will stop working.
The up fan runs at low speed and the down fan stops running
WATER-DRAINAGE
Manual drainage:
- When the internal water tank is full the unit will stop working.
- Shut off the unit and unplug it. Try not to move the model abruptly as this may cause water to spill out from the internal water tank.
- Place a tray under the water plug.
- Screw off the drain plug and unplug the water rubber stopper – water will drain from the container.
- Put the water rubber stopper back and screw the drain plug cap back into place
Continuous drainage:
- Screw off the drain plug cap and unplug the water rubber stopper.
- Use a water pipe to connect to the water outlet.
- You can plumb this pipe into your current plumbing system, lead it outside or use a water pump.
Note : This model has a self-evaporative function, which reduces the need
to empty the water tank.
If the unit is vented correctly most of the water is reused to cool the
condenser coils and any excess is evaporated.
Please do not use continuous drainage if you intend to use the self-
evaporating facility
Maintenance
Cleaning
- Please shut off the unit and unplug from the mains before cleaning or performing any maintenance
Clean the surfac e
- Clean the plastic housing with a duster or a soft wet cloth.
- Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage.
Air filter cleaning
- a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected.
- b) Pull out the top and bottom filters as pictured below
- c) Wash the air filters by immersing them in warm (about 40?C) water with a neutral detergent.
- d) Rinse it and then dry it thoroughly.
- e) Carefully re-install the air filters
Please note: If used, the optional active carbon filter (cloth) should be replaced every 3-6 months based on the environment.
End-of-Season Maintenance
- Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit.
- Then switch the unit to low fan mode.
- Keep the unit in this mode for half a day – until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold from developing
- Turn off the unit and pull out the plug.
- Coil the wire and bind it together, then put it into the accessories space.
- Separate the air-exhaust pipe and store it safely.
- Cover the unit and keep it in a dry place.
- Take the batteries out of the remote control and store or dispose, of them safely
Keep all accessories with the unit ready for next season.
Troubleshooting
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm.
Trouble | Reason | Solution |
---|
The unit does not work
| No power supply| Power-on and turn on the unit.
Water-full indicator illuminated| Drain the internal water tank
The timer function is active| Cancel Timer function
Room temperature too low or too high| Use only in ambient temperatures between
7-40⁰C
The unit does not seem to perform.
| In direct sunlight| Draw the curtains, UV affects RC
Windows or doors open.
A large amount of people or a heat source in the room.
| Close windows and turn on another air conditioner
The filter is very dirty| Clean or change the air filter
Air inlet or air outlet is blocked| Clear out debris
The room temperature is lower than the set temperature|
Change the setting temperature
The unit loud| The unit is not put on a flat surface| Put the unit on a flat and hard surface
The compressor does not work
|
Overheating protection is active
| Check venting.
Restart the unit after 5 minutes when the compressor has cooled
Remote control doesn’t work
| The operating distance is too far.| Move the remote control closer to the
unit and make sure it aims at the air-outlet grille
The control panel has not received the signal from the remote control.
The batteries are flat| Replace the batteries
| |
E1 on LED|
Room temperature is abnormal
| Temperature not within 5-40 C operating range. If the temperature is within operating range refer to the Service Centre
(check room temperature sensor or relevant circuit)
E2 on LED|
The coil temperature is abnormal
| Refer to Service Centre
(check coil temperature sensor or relevant circuit)
The main LED light flashing| The water tank is full inside the machine| Drain out water from the drain port at the bottom rear of the unit.
Others
|
No refrigerant or there is very little refrigerant
| Refer to Service Centre (check leakage, wielding, vacuum pump, charge refrigerant according to nameplate)
Anti-freezing protection
| Waiting for defrosting.
The function will recover automatically. No user input is needed.
High-pressure protection
| After the inside gas pressure comes down, it will function normally. No user input needed
If the above solutions do not resolve the problem please contact the service center.
APPENDIX
Disposal: Do not dispose of this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centers.
TECHNICAL DATA
Capacity| Cooling: 2.93 kWh
10,000 BTU
---|---
Rated Input| Cooling:1.12 kW
Running Current| 4.95A
Air Flow| 435m3/h
EER Rating| A
Compressor| Rotary, R410A gas
Noise| 38-48dB(A) Sound Energy
<65dB(A) Sound Power
Thermostat| 16-31⁰C
Moisture removal| 28.8 l/day
Permitted Excessive Operating Pressure| 0.8/3.2MPa
Maximum Allowable Pressure| 1/5Mpa
Power Supply| 220-240V/50Hz
Net Weight| 25kgs
Dimension (LDH)| 360350750mm
Unit must be vented outside when in Air Cooling and Heating mode.
For the purposes of EU regulation EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy.
ElectriQ UK SUPPORT
www.ElectriQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the
service line.
If the unit still fails to operate call: 0871 620 1057 or complete the online
form
- Has the unit been standing upright for at least 2 hours?
- Is the unit plugged into the mains?
- Is the fuse OK?
- Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
- Check if the water tank is full.
Office hours: 9 AM – 5 PM Monday to Friday
www.ElectriQ.co.uk
Unit 2, The Nursery
Berristow Lane
South Normanton
Derbyshire, DE55 2FX
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>