Russell SA14AZ18AJ1NA Line iM Air Conditioners User Manual

June 13, 2024
Russell

Russell logo Vantix™ Line
iM Air ConditionersRussell SA14AZ18AJ1NA Line iM Air
Conditioners SA14AZ
Cooling Efficiency up to: 16 SEER2/13 EER2
Nominal Sizes: 11
/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]Russell
SA14AZ18AJ1NA Line iM Air Conditioners - Symbols

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Features and Benefits

  • Lighter Footprint & Less Environmental Impact from New 7mm Condenser Coil: Provided by a decrease in refrigerant requirements and an overall weight reduction
  • Efficient Cooling: Up to 16 SEER2/13 EER2
  • Expanded Value Space: 3 in. – 4 in. – 5 in. service valve space – provides a minimum working area of 27-square inches for easier access
  • Triple Service Access: 15 in. wide, industry leading corner service access – makes repairs easier and faster. The two fastener, removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
  • System Matching Simplicity: Matches to all tiers of gas furnaces
  • Modern Cabinet Aesthetics: High curb appeal with visually appealing design
  • Curved Louver Panels: Provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
  • Diagnostic Service Window: With two-fastener opening – provides access to the high and low pressure
  • External Gauge Port Access: Allows easy connection of “low-loss” gauge ports
  • QR Code: Provides technical information on demand for faster service calls
  • Fan Motor Harness: With extra-long wires allows unit top to be removed without disconnecting fan wire

Air Conditioners

S A 14 A Z 24 A J 1 N A LHP
Brand Product Category SEER2 Region Refrigerant Capacity BTU/HR Major
Series Voltage Type Controls Minor Series Option Code

S – Russell®
By Rheem| A – Air Conditioners| 14 – 13.8/14.3 SEER2| A – All| Z – R-410A| 18 – 18,000  [5.28 kW] 24 – 24,000  [7.03 kW] 30 – 30,000  [8.79 kW] 36 – 36,000 [10.55 kW] 42 – 42,000 [12.31 kW] 48 – 48,000 [14.07 kW] 60 – 60,000 [17.58 kW]| A – 1st Design| J – 1ph, 208-230/60| 1 – Single Stage| N – Non- Communicating| A – 1st Design| LHP – W/HLPC
[ ] Designates Metric Conversions AVAILABLE MODELS| DESCRIPTION
---|---
SA14AZ18AJ1NA| Vantix™ Line 1 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ18AJ1NALHP| Vantix™ Line 1 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ24AJ1NA| Vantix™ Line 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ24AJ1NALHP| Vantix™ Line 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ30AJ1NA| Vantix™ Line 2 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ30AJ1NALHP| Vantix™ Line 2 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ36AJ1NA| Vantix™ Line 3 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ36AJ1NALHP| Vantix™ Line 3 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ42AJ1NA| Vantix™ Line 3 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ42AJ1NALHP| Vantix™ Line 3 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ48AJ1NA| Vantix™ Line 4 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ48AJ1NALHP| Vantix™ Line 4 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ60AJ1NA| Vantix™ Line 5 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ60AJ1NALHP| Vantix™ Line 5 ton 14.3 SEER2 Single-Stage iM  Air Conditioner w/ High/Low Pressure-208/230/1/60
STANDARD EQUIPMENT

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

General Data

Russell SA14AZ18AJ1NA Line iM Air Conditioners - Table¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

Russell SA14AZ18AJ1NA Line iM Air Conditioners -
Accessories

Weighted Sound Power Level (dBA)

Russell SA14AZ18AJ1NA Line iM Air Conditioners - Accessories
1 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions

Russell SA14AZ18AJ1NA Line iM Air Conditioners - Unit
DimensionsRussell
SA14AZ18AJ1NA Line iM Air Conditioners - Unit Dimensions
1 [ ] Designates Metric Conversions

CLEARANCES

Russell SA14AZ18AJ1NA Line iM Air Conditioners -
CLEARANCES NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re- circulation of discharge air.

Control Wiring

Russell SA14AZ18AJ1NA Line iM Air Conditioners -
ControlFIGURE 2
CONTROL WIRING FOR GAS OR OIL FURNACE
FOR TYPICAL GAS OR OIL HEAT
BR –BROWN WIRE
YL –YELLOW WIRE
X–WIRE CONNECTION*IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER.
Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

NOTES:

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Refrigerant Line Size Information Russell SA14AZ18AJ1NA Line iM Air
Conditioners - Control 4NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if outdoor unit is above indoor unit.
  3. **19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Russell SA14AZ18AJ1NA Line iM Air Conditioners - Control
5 NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if outdoor unit is above indoor unit.
  3. **19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data

@ AHRI Standard Conditions – Cooling

Russell SA14AZ18AJ1NA Line iM Air Conditioners - Control
6 NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
[ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY*

Russell® By Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required) ……………………………Ten (10) Years
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2023 Rheem Manufacturing Company. Russell By Rheem trademarks owned by Rheem Manufacturing Company.
In keeping with its policy of continuous progress and product improvement, Russell by Rheem reserves the right to make changes without notice.

Russell by Rheem
5600 Old Greenwood Road
Fort Smith, Arkansas 72908
www.russellbyrheem.com
PRINTED IN U.S.A. 3/23 QG FORM NO. ARR-337 REV. 2

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Russell User Manuals

Related Manuals