Hotpoint RAK204D20H Subbase PTAC Heat Pump Unit Installation Guide

June 13, 2024
Hotpoint

Hotpoint logo Installation Instructions
for your new
RAK204D20H
208/230V, 20 Amp Subbase

RAK204D20H Subbase PTAC Heat Pump Unit

Before you begin – Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installe r – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.

Tools Needed

  • 5/16” nut driver
  • Pliers
  • Slotted screwdriver

Parts included in bag with Sub-BaseHotpoint RAK204D20H Subbase PTAC
Heat Pump Unit - Parts Important Notes

  • This unit must be properly grounded.
  • Read this instruction before installing the sub-base to the molded or metal sleeve.

CAUTION
The sub-base should be assembled to the sleeve before securing the sleeve in the wall.
CAUTION
Electrical power must be disconnected before installing the sub-base.

Electrical Requirements :

  1. Electrical wiring may enter the sub-base through any of the knockout holes provided in the sub-base bottom or rear.
  2. Refer to the unit nameplate for branch circuit requirements.
  3. All wiring should be done in accordance with the local electrical codes and regulations.
  4. Not approved for aluminum wire application.
  5. When connecting the electrical wiring, the sub-base must be properly grounded. See diagram on next page. A ground wire from the supply line shall be connected to sub-base grounding stud with one of the supplied nuts.

Installation Instructions

Hotpoint RAK204D20H Subbase PTAC Heat Pump Unit - diagram
1

  1. Route power cord through cord hole edge protector through the semi-circle hole in the right-most panel of the subbase. Hotpoint RAK204D20H Subbase PTAC Heat Pump Unit - diagram 2
  2. Plug the cord into the receptacle.
  3. Secure all covers on the sub-base. Hotpoint RAK204D20H Subbase PTAC Heat Pump Unit - diagram 3

Note: A junction box and chaseway is NOT required for this Hotpoint PTAC installation as the cord is equipped wiith an LCDI power cord. However, if they are desired for a cleaner installation, these GEA service parts may be ordered separately:

  • Junction Box: WP76X29134
  • Chaseway: WP76X29133

Hotpoint logoSpecifications subject to change without notice.