Securakey RK-600 Stand Alone Proximity Access Control System Installation Guide
- June 13, 2024
- Securakey
Table of Contents
- Securakey RK-600 Stand Alone Proximity Access Control System
- Product Information
- Product Usage Instructions
- INTRODUCTION
- PROGRAMMING RADIO KEY® 600
- PROGRAMMING STEPS
- PROGRAMMING HINTS
- BASIC OPERATION
- SYSTEM CONFIGURATION
- WIRING
- ACCESS CONTROL UNIT
- INSTALLING THE UNITS
- SPECIFICATIONS
- INSTRUCTION TO THE USER
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Securakey RK-600 Stand Alone Proximity Access Control System
Product Information
The RK-600 is an access control unit that allows for the management of up to 600 Proximity Transponders (Key Tags) or PIN codes for keypad entry. It can control an electric strike, magnetic lock, or gate operator, and has additional features such as an exit switch input and external alarm shunting contacts. The unit includes a CPU, memory, access relay, internal reader, beeper, bi-color LED indicator, and a 16-position keypad. The RK-600 is weather resistant and comes with a gasket for exterior installation. It also includes various accessories such as a mounting plate, connector/wire pigtail, operating manual, quick start guide, user log form, and mounting screws. The RKAR Auxiliary Reader is an optional component recommended for extreme weather or higher security applications. It parallels the internal reader in the RK-600 and features a bi-color LED indicator and a beeper. A gasket is provided for exterior installation. The RK-PS is a 12VDC plug-in power supply that is optional and designed specifically to power the RK-600. It requires a 120 VAC input. The RK600-BB Back Box/Spacer is another optional accessory that extends the RK-600 out from the mounting surface and provides additional room for wiring.
Product Usage Instructions
- Installation: Follow the installation guide provided in the operating manual to mount the RK-600 unit. Use the included accessories such as the mounting plate, connector/wire pigtail, and screws for proper installation. Optionally, you can install the RKAR Auxiliary Reader and use the RK-PS power supply or RK600-BB Back Box/Spacer if needed.
- User Management: To add or delete transponders or PIN codes, set the operating mode, program the password and latch timer, or enter PINs, use the 16-position keypad on the RK-600 unit. Refer to the operating guide for detailed instructions on these functions.
- Recording User Information: Record the User Number, Transponder ID Number or PIN code, and the user’s name. Keep this information in a secure place. Use the provided User Log Form as a photocopy master.
- Error Warnings: If you make an error during a keypad sequence, a red light and three beeps will occur. Refer to the appropriate section in the operating guide and carefully re-enter the command in the proper sequence.
- Avoiding User Number Conflicts: If a Transponder ID Number or PIN has already been stored in memory for a specific User Number, selecting that User Number for a new Transponder or PIN will result in a red light and three beeps. In such cases, select another User Number or void the User Number to remove the previously stored Transponder ID or PIN Number from memory.
INTRODUCTION
The Radio Key® 600 is a programmable single-door access control system which allows any mix of up to 600 Proximity Transponders (Key Tags) or PIN codes for keypad entry. It can control an electric strike, magnetic lock, or gate operator, and has an additional input for an exit switch and output contacts for external alarm shunting. The major components are shown
RK600 Components
The RK600 Access Control Unit contains the CPU, memory, access relay, and an
internal reader. It has a beeper, bi-color LED indicator and a 16-position
keypad, which is used to add or delete transponders or PIN codes, to set the
operating mode, to program the password and latch timer, and for PIN entry.
The RK600 is weather resistant and is provided with a gasket for exterior
installation.
Parts Supplied:
Access Control Unit
Gasket
MOV
Mounting Plate
Connector/Wire Pigtail
Operating Manual
Quick Start Guide and Wallet Sized Guide
User Log Form
2, 6-32 x 1/2” mounting screws
1, 4-40 x 5/16” Phillips housing screw
1, 4-40 x 5/16” Hex Socket, security housing screw
The RKAR Auxiliary Reader is optional, but recommended for extreme weather or
higher security applications. This reader parallels the internal reader in the
RK600. It contains a bi-color LED indicator and a beeper also driven by the
RK600. A gasket is provided for exterior installation. The RKAT Audit Trail
Module is optional and allows the RK600 to connect to a PC or Printer for
Audit Trail Reporting and programming. RK-LINKTM Software for Windows® is
included. RK-PS, a 12VDC plug-in power supply is optional. It is designed to
power the RK600 only, and requires 120 VAC input. RK600-BB Back Box / Spacer
is optional. It extends the RK600 out from the mounting surface and provides
additional room for wiring.
PROGRAMMING RADIO KEY® 600
Radio Key® Transponders (Key Tags) are pre-encoded and engraved at the factory with unique Transponder ID numbers. Because these numbers are unique, Facility Codes (Site Codes) are not required. Transponder ID Numbers are not pre- programmed into the Radio Key® 600; you must add them to the system as described below. Radio Key® 600 allows you to assign either a Transponder or a PIN code to each User Number (1 – 600) for programming purposes. The User Number is associated with the individual person using the transponder or PIN code. Be sure to record the User Number, the Transponder ID Number or PIN code and the user’s name, and keep this information in a secure place. A blank User Log Form has been included for this purpose. Do not write on this form; use it as a photocopy master. Because a new Transponder ID Number or PIN can be assigned to any available User Number, the reader always has capacity to store 600 Transponders or PINs, even after many Transponders or PINs have been voided from the reader.
Error Warnings
A red light and three beeps at the end of a keypad sequence means that you
have made an error. Refer to the appropriate section, and carefully re-enter
the command in the proper sequence. If you select a User Number for a new
Transponder or PIN, and a Transponder ID Number or PIN has already been stored
in memory for that User Number, a red light and three beeps will occur. Select
another User Number or void the User Number, which removes the previously
stored Transponder ID or PIN Number from memory.
NOTE: User Number and ID Number Values in the following examples are for
demonstration purposes only; enter the appropriate values for your system.
PROGRAMMING STEPS
To Enter Program Mode:
Enter your 5-digit password, then press ENTER. (All new units are pre-
programmed with the password 12345.) The LED will flash amber to show that the
unit is in Program Mode. The unit will “time out” and return to Active
(Normal) Mode in 15 seconds if no key is pressed.
Add a Transponder (Key Tag) to the System:
Enter Password. Press ENTER. Press ADD. Enter a User Number (1 – 600) and
press ENTER. Hold the Transponder near the RK600 Unit. A green light and beep
means that the Transponder was accepted. A red light and three beeps means a
Transponder has already been stored for the selected User Number. Delete the
previously stored Transponder or select a new User Number.
Add a Transponder by Entering the Transponder ID:
Instead of presenting the transponder, you can also use the Keypad to enter
the Transponder ID number: Enter Password. Press ENTER. Press ADD, enter the
User Number, press *, enter the ID number printed on the Transponder, then
press ENTER.
Record the User Number and Transponder ID Number in the User Log Form.
Add a Series of Transponders to the System:
Enter Password. Press ENTER. Press ADD. Enter the Starting User Number in the
range. Press , enter the Ending User Number, press , then press ENTER.
Present the Transponders to the reader in the desired order (making a careful
record of which transponders are assigned to which User Numbers). If one or
more Transponders are already entered into the User Number range you have
selected, a red light and three beeps will occur, in which case, you must
delete the entire range before proceeding.
Add a PIN to the System:
Enter Password. Press ENTER. Press ADD. Enter the User Number and press ADD,
enter the 4-digit PIN code, then press ENTER.
Note: A PIN must be 4 digits. If the PIN has leading zeros, they must be entered as this example shows – “0004”.
Delete a Transponder or PIN from the System:
Enter Password. Press ENTER. Press VOID. Enter the User Number. Press ENTER. A
green light and beep means that the Transponder or PIN was deleted.
Delete a Range of Transponders/PINs from System:
Enter Password. Press ENTER. Press VOID. Enter the Starting User Number in the
range, press *, enter the Ending User Number, then press ENTER. A green light
and beep means that the range of Transponders/ PINs was deleted.
Delete a Transponder by Presenting to Reader:
Enter Password. Press ENTER. Press VOID, then press ENTER. Hold the
Transponder near the RK600 Unit. A green light and beep means that the
Transponder was deleted.
Delete a Transponder by Entering Transponder ID:
Enter Password. Press ENTER. Press VOID, press *, enter the ID number printed
on the Transponder, then press ENTER. A green light and beep means that the
transponder was deleted.
Change your Password:
Enter your current Password. Press ENTER. Press , then enter the new Password
(exactly 5 digits). Press again, then re-enter the new Password and press
ENTER. A green light and beep means that the Password was changed. Note that
12345 is the default (factory) password; use another number sequence for best
security.
Set the Latch Timer:
Enter Password. Press ENTER. Press SET TIMER. Enter the number of seconds
(0-30). Press ENTER. A green light and beep means that the Latch Timer setting
was changed.
Set the Operating Mode:
Enter Password. Press ENTER. Press MODE, then press 1, 2 or 3 and Press ENTER.
The Access Control Unit will exit Programming Mode and enter the selected
Mode. Selections are:
- Active (Normal) — LED is Off
- Inactive (Locked) — LED blinks Red
- Door Unlocked — LED blinks Green
To Exit Programming Mode Immediately:
Press MODE, then press 1, then press ENTER. This returns the unit to normal
mode immediately, bypassing the 15 second time-out.
PROGRAMMING HINTS
Password
If the password is lost or forgotten it can be restored to the factory
default. Remove the RK600 unit from the mounting plate, disconnect power
(unplug the connector from J1 or disconnect the DC power supply) press and
HOLD the reset switch (SW1, on the reader circuit board), restore power, then
release the switch. Note that this will also reset the latch timer and
operating mode to the factory default.
Adding the Same Transponder More Than Once
If you add the same Transponder to the system more than once, the Transponder
ID will be deleted from the previous User Number position and added to the
newest User Number position. This does not apply to duplicate PIN codes; the
same PIN can be assigned to multiple User Numbers.
Setting the Latch Timer
The latch timer controls the latch relay, which has two sets of contacts; one
for unlocking the door or gate, and one for bypassing an external alarm
system. The factory preset latch time is 1 second but it can be changed to any
value from 0.25-30 seconds. If the latch timer is set to 0 seconds, this
pulses the latch relay for 0.25 second, sufficient for most electric
turnstiles. The beeper and LED are always fixed at one second.
Setting the Operating Mode
Three operating modes are possible. For normal operation select Mode 1; to
temporarily lock out all transponders and PIN Codes select Mode 2; to hold the
door open continuously select Mode 3.
BASIC OPERATION
To use a Key Tag with Radio Key® 600, simply hold your Radio Key® Transponder near the RK600 Unit or optional Auxiliary Reader. The RK600 Unit or Auxiliary Reader generates an RF field, which causes the Key Tag to transmit a unique Transponder ID Number back to the Auxiliary Reader or RK600 Unit. If the Transponder ID Number is stored in memory, the latch relay is activated, unlocking the controlled door or gate and shunting any external alarms. A green light and a beep indicates that access is granted. If the Transponder ID Number is not stored in memory, the door or gate remains locked and a red light and three rapid beeps indicate that access is denied. Otherwise the LED is normally off. To use a PIN code with Radio Key® 600, enter your User Number, your 4-digit PIN code, then press *. Leading zeros can be omitted for the User Number: enter 2 or 21, not 002 or 021. Zeros must always be entered if they are part of the 4-digit PIN number.
NOTE: If five incorrect PINs (or passwords) are entered, the unit will sound an alarm and display a red LED for 30 seconds, then return to normal mode.
SYSTEM CONFIGURATION
RK600 Unit Only
Locate on the exterior wall, near the latch side of the controlled door.
Height should be 36” – 48” (check local codes). Use weather gasket (supplied)
for outdoor installations.
RK600 Unit with Optional Auxiliary Reader
Auxiliary Reader – Locate on the exterior wall, near the latch side of the
controlled door. Height should be 36” – 48” (check local codes).
RK600 Unit – Locate inside the secure area. For use as an exit reader, mount
the RK600 Unit on the interior wall at the same relative location as the
Auxiliary Reader but not directly behind it. For best reading distance, offset
the RK600 Unit and Auxiliary Reader by about 6”. Otherwise, the RK600 Unit can
be mounted up to 30 cable feet away from the Auxiliary Reader.
Metal Surfaces – Effect on Reading Distance
Normally, Radio Key® 600 will read Key Tags at up to 6”. However, when the
RK600 Unit or optional Auxiliary Reader is mounted directly on a metal
surface, the reading distance decreases slightly. To reduce this effect,
install the Spacer (optional) between the mounting surface and the mounting
plate; this will restore most of the reading distance.
Vehicle Gate Applications
Optional Auxiliary Reader – Locate 8 – 12 feet in front of gate on driver’s
side. A Post Mount Adapter or Flange Mount Adapter is available for post
mounting. Install the optional Spacer between the mounting adapter and
Auxiliary Reader to reduce the effect on reading distance caused by the metal
mounting adapter. Alternatively, the RK600 can be used alone, post mounted
with weather gaskets.
RK600 Unit – Locate in nearby building, guard house or water-tight (NEMA)
enclosure up to 30 cable feet from Auxiliary Reader. For metallic NEMA
enclosures, install the optional Spacer between the enclosure wall and RK600
to reduce the effect on reading distance caused by metal. Locate the RK600 in
the center of the NEMA enclosure. Non-metallic NEMA boxes will have no effect
on reading distance.
Concealed Installation
The optional Auxiliary Reader can be mounted behind any non-metallic wall
surface, (glass, wood paneling, plastic, drywall). The reading distance may be
affected slightly by metal framework or structural material in the wall.
WIRING
Run the following cables to the RK600 Unit location. Conduit is recommended to reduce the effects of EMI/RFI and for physical protection of the wires.
Table 1 – Cable Types and Distances
Wire Application| Cable Type| Description
From Power Supply| 2-cond, 18-22 AWG| n/a
From Locking Device and power supply or gate operator| 2-cond. See Mfr’s
Specifications| n/a
From external alarm system’s Door Monitor Switch (for shunting)| 2-cond, 18-22
AWG| 250 feet
From Exit Button or PIR| 2-cond, 18-22 AWG| 250 feet
From Optional Auxiliary Reader| 2-cond unshielded 22 AWG, plus a separate
4-cond, shielded 22- 24 AWG cable| 30 feet
RK600 Wire Connections
The RK600 Unit is supplied with a pre-wired connector (P1) with color-coded
wire leads. Referring to Table 2, Connector P1 Color Coding and Figure 3,
Wiring Diagram, make all appropriate connections from Connector P1 to the
power supply, locking device or gate controller, external alarm circuit and
Request-to-Exit (REX) input. Use solder and tape or gel-filled crimp-on
connectors.
Note: Max relay power rating with resistive load is 2A@24V DC or AC;
0.5A@115VAC. Use an interposing relay to switch greater loads.
The RK600 does not supply power to operate electric strike or magnetic locks –
a separate supply is required. Refer to strike/ magnetic lock manufacturers
instructions. Users can request to exit through the controlled door without
using a transponder or PIN (and without causing an alarm condition), by
pressing an Exit button or triggering the relay output of an Exit PIR
connected to the RK600 Unit. This will operate the latch relay for the
programmed latch time. When wiring the REX Input, connect the brown wire to
one side of the REX switch contact and connect the other side of the switch to
the orange wire. This input must be a dry contact, with no voltage present.
Use a Separate Power Supply for Electric Locks
The access control unit and the electric locking device should be connected to
separate power supplies. Install the MOV provided as shown below:
MOV Wiring Diagram
Auxiliary Reader Wire Connections
A short cable assembly extends from the back of the Optional Auxiliary Reader.
Connect Plug P2 at the end of the cable to Socket J2 at the RK600 Unit. If the
cable must be extended, for the best performance, use TWO SEPARATE CABLES: one
unshielded, non-twisted, two-conductor wire to the antenna coil (Pins 1 & 2),
plus a SEPARATE 4-conductor shielded cable to the LED and Beeper (Pins 3 – 6).
These cables can be run in the same conduit. Connect the cable shield from the
LED/Beeper cable to the black wire (GND) on P1 at the RK600.
Route the auxiliary reader cable at least two feet away from sources of EMI
(electro-magnetic interference), such as radio transmitters, elevators, large
electric motors or fluorescent light ballasts.
WARNING
Use of any Auxiliary Reader cable which combines all conductors inside one
shield and/or uses twisted pair for the antenna lines will result in severely
reduced reading distance. Failure to properly ground the cable shield for the
LED/Beeper lines will also result in severely reduced reading distance.
NOTE: When power is applied to the RK600, the unit is calibrated for the
current antenna configuration. Always connect the Auxiliary Reader first, before
applying power to the RK600.
Surface-Mounted Wiring
For installations where it is necessary to run cable along the wall surface
(such as in a wall-mounted modular raceway) small break-away knockouts are
provided on the bottom of the RK600 and Auxiliary Reader housings, as well as
on the Spacer. Remove the knockouts with small pliers, and butt the raceway up
against the opening in the housing to conceal the cable.
Power
The RK600 can be powered by the optional RK-PS 12VDC power supply, which is
rated for powering the RK600 only. Alternatively, use any good 9-14 VDC supply
which provides at least 150mA. DC power should be clean and filtered with no
more than 1 VAC ripple (Peak to Peak). Do not run AC power in the same cable
with DC power to the reader.
WARNING
RK600 will not operate on AC Voltage or with DC polarity reversed.
ACCESS CONTROL UNIT
- SOLID LINE FOR ELECTRIC STRIKE OR OTHER FAIL-SECURE LOCKING DEVICE; DASHED LINE FOR MAGNETIC LOCK OR OTHER FAIL-SAFE LOCKING DEVICE.
- USE SHIELDED CABLE FOR J2, PINS 3 – 6, AND UNSHIELDED, NON-TWISTED SEPARATE CABLE FOR PINS 1 & 2 (SUCH AS “ZIP CORD”, LAMP COARD OR SPEAKER WIRE)
- USE UNSHIELDED CABLE 18-22AWG FOR PINS 1-10
- NOTE: IF COMMON POWER SUPPLY IS USED FOR BOTH THE RK600 AND ELECTRONIC DOOR LOCK, BE SURE TO INSTALL THE MOV WHICH IS PROVIDED WITH THE ACCESS CONTROL UNIT.
Table 2 – Connector P1 Color Coding
Wire Application| Wire| Color| Description
Power Input| 1| Red| + 9 to 14 VDC
2| Black| DC Power Ground
Strike/Operator Relay| 3| Green| Latch, Common
4| Blue| Latch, Normally Closed
5| Yellow| Latch Normally Open
Alarm Shunt Relay| 6| Blue/Black| Shunt, Normally Closed
7| Yellow/Black| Shunt, Normally Open
8| Green/Black| Shunt Common
REX
| 9| Brown| REX Input
10| Orange| REX Input
Table 3 – Connector P2 Color Coding
Wire Application| Wire| Color| Description
Antenna| 1| White| Coil 1
2| Blue| Coil 2
LED Control| 3| Orange| LED, Red
4| Green| Led, Green
Beeper| 5| Yellow| Beeper Control
6| Red| VCC
Shield/ Drain Wire| n/a| Bare Wire| Connect to J1, Pin 2
INSTALLING THE UNITS
Installation Hints
Each unit (RK600 Unit or Auxiliary Reader) consists of two parts: a mounting
plate and a housing. The Back Box / Spacer is optional. When mounting the unit
on metal, install the optional Back Box /Spacer (Figure 5) between the
mounting plate and the mounting surface to minimize the loss of reading
distance caused by the metal. The spacer can also be used on non-metallic
surfaces to provide additional room for wiring connections. When mounting the
RK600 Unit and Auxiliary Reader on opposite sides of a wall, offset the units
by about 6” for the best reading distance. Do not locate two RK600 units
closer than two (2) feet apart. Do not locate the RK600 or RKAR within two (2)
feet of a PC Monitor or CPU enclosure, or any other source of EMI (electro-
magnetic interference) such as radio transmitters, elevators, large electric
motors or fluorescent ballasts. If the RK600 or Auxiliary Reader must be
concealed, the RK-GM glass mount kit can be used to permanently adhere the
unit to the back of a glass window. The RK-GM consists of two parts: a large
PVC sheet which adheres to the inside of the window, and a smaller adhesive
sheet that is used to affix the RK600 mounting plate to the larger sheet. To
allow cables to exit the reader housing, remove the small knockout(s) on the
bottom of the housing by prying out with small pliers.
Installation Procedure
- Orient the mounting plate with the threaded insert at the bottom; attach it to a single-gang electrical box with two 6-32 x 1/2” screws (supplied); or attach directly to the wall surface, using anchor screws or toggle bolts. Basic Installation
- If using the optional spacer, insert spacer alignment pins into corresponding holes on the back of the mounting plate, then install both parts so that the spacer is closest to the wall or mounting surface.Wall Mounting on Metal Surface with Optional Spacer
- For exterior applications, install the thick gasket between the wall or mounting surface and the back of the mounting plate.
- If using the optional spacer, install the thick gasket between the spacer and the mounting surface, install the mounting plate and spacer using the two 6-32 x 1-1/2” screws supplied with the spacer, then place the thin gasket around the mounting plate .Post/Flange Mounting
- Pull cable ends through the access hole in the mounting plate:
- If using the Auxiliary Reader, connect Plug P2 at the cable end to Socket J2 at the RK600 Unit, grounding the shield at the RK600 Unit end only. The Auxiliary Reader must be connected before power is applied to the RK600.
- Connect Plug P1 to Socket J1 on the RK600 Unit circuit board.
- Attach the housing to the mounting plate:
- Hold the bottom end of the housing away from the mounting plate.
- Insert the two tabs (inside top of housing) into the two slots at the top of the mounting plate.
- Swing the bottom of the housing toward the mounting plate.
- Secure by installing the 4-40 x 5/16” Philips screw (supplied) into the hole at the bottom. The 4-40 x 5/16” Hex Socket tamper-proof screw (supplied) can be substituted for additional security. The optional security tool (ST-2) is required in order to use the tamper-proof screw.
- Apply power. The LED will flash once and the beeper will sound. Refer to beginning of this manual for programming and operating instructions.
Troubleshooting
If your unit does not appear to be working, first check to see if the RK600 is
getting 9-14 VDC power and that the polarity is correct. The unit should make
a clicking sound when any key on the keypad is depressed. If you remove and
restore power, the unit should beep once and the LED should flash Amber once.
Returning a Unit
If you believe you have a defective unit, please contact the dealer or
distributor who sold you the unit. All service and repairs must be done
through an authorized dealer or distributor.
Ordering Additional Transponders
If you need additional Transponders, please contact the dealer who sold you
the Radio Key® 600 unit. Because Radio Key® transponders are uniquely encoded
and do not use facility codes, you can buy them off-the-shelf from any Secura
Key dealer. If you do not know who your dealer is, call Secura Key and we will
recommend one near you.
WARRANTY (U.S. and Canadian)
“Secura Key products are warranted against defects in materials and
workmanship for LIFE. Secura Key will replace any Secura Key manufactured
product, except cards or tags, returned to us freight prepaid within the
warranty period. This warranty does not include freight, taxes, duties, or
installation expenses. THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER
WARRANTY, WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED. SECURA KEY
SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. The remedies provided herein are the buyers’ sole
and exclusive remedies. In no event shall Secura Key be liable for direct,
indirect, special, incidental or consequential damages (including loss of
profits), whether based on contract, tort or any other legal theory.” Contact
Secura Key for Export Warranty Policy.
SPECIFICATIONS
This product complies with UL 294 Standards, CE (European Standards) and with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
FCC ID: NNHRK600
INSTRUCTION TO THE USER
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more or the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet of a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment.
Rev. J
P/N 3320831
*Patent #6317027
20301 Nordhoff Street
- Chatsworth, CA 91311
- Phone: 818-882-0020
- Fax: 818-882-7052 TOLL
- FREE: 800-891-0020
mail@securakey.com
securakey.com