Scheppach SG3500i Inverter Gasoline Power Generator Instruction Manual
- June 13, 2024
- Scheppach
Table of Contents
- SG3500i Inverter Gasoline Power Generator
- Explanation of the symbols on the device
- Introduction
- Device description (Fig. 1 – 14)
- Scope of delivery (Fig. 4)
- Proper use
- General safety instructions
- Technical data
- Unpacking
- Before commissioning
- Operation
- Cleaning and maintenance
- Storage
- Transport
- Disposal and recycling
- Troubleshooting
- Maintenance plan
- EC Declaration of Conformity
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Art.Nr.
5906230903
AusgabeNr.
5906230903_0001
Rev.Nr.
23/12/2022
SG3500i Inverter Gasoline Power Generator
SG3500i
Inverter generator
**Translation of original instruction manual
https://www.scheppach.comide/service
**
Explanation of the symbols on the device
Symbols are used in this manual to draw your attention to potential hazards. The safety symbols and the accompanying explanations must be fully understood. The warnings themselves will not rectify a hazard and cannot replace proper accident prevention measures.
| Attention! Failure to observe the safety signs and warning information
affixed to the machine and failure to observe the safety and operating
instructions can result in serious injury or even death.
---|---
| Warning – read the instruction manual to reduce the risk of injury.
| Wear hearing protection. Excessive noise can result in a loss of hearing.
| Wear work gloves!
| Do not expose the device to rain.
| Naked flames or smoking near the device is strictly prohibited!
| Warning – Hot parts!
| Warning against electrical voltage.
| Make sure that other persons maintain a
sufficient safety distance. Keep uninvolved persons away from the device.
Attention: hot surface! Danger of burning.
| Before carrying out any cleaning or maintenance work, switch off the engine
and remove the spark plug connector from the spark plug.
| Danger of poisoning! Only use the device outdoors and never in closed or
poorly ventilated rooms.
| Sparks are produced when the engine is started. These can ignite nearby
flammable gases.
| Read the whole text of the operating instructions through carefully before
start up!
| Important. Always switch off the engine before refuelling. Do not refill
during operation.
| Be very careful when dealing with fuels and lubricants!
| Checking the oil level
**| The product complies with the applicable European directives.
Attention!**| We have marked points in these operating instructions that
impact your safety with this symbol.
Introduction
Manufacturer:
Scheppach GmbH
Günzburger Straße 69
D-89335 Ichenhausen
Dear Customer,
We hope your new tool brings you much enjoyment and success.
Note:
In accordance with the applicable product liability laws, the manufacturer of
this device assumes no liability for damage to the device or caused by the
device arising from:
- Improper handling,
- Failure to comply with the operating instructions.
- Repairs carried out by third parties, unauthorised specialists.
- Installing and replacing non-original spare parts,
- Application other than specified.
- Failures of the electrical system in the event of the electrical regulations and VDE provisions 0100, DIN 57113 / VDE 0113 not being observed.
Note:
Read through the complete text in the operating manual before installing
and commissioning the device.
This operating manual should help you to familiarise yourself with your device
and to use it for its intended purpose. The operating manual includes
important instructions for safe, proper and economic operation of the device,
for avoiding danger, for minimising repair costs and downtimes, and for
increasing the reliability and extending the service life of the device.
In addition to the safety instructions in this operating manual, you must also
observe the regulations applicable to the operation of the device in your
country. Keep the operating manual at the device, in a plastic sleeve,
protected from dirt and moisture. They must be read and carefully observed by
all operating personnel before starting the work. The device may only be used
by personnel who have been trained to use it and who have been instructed with
respect to the associated hazards. The required minimum age must be observed.
In addition to the safety instructions in this operating manual and the
separate regulations of your country, the generally recognised technical rules
relating to the operation of such machines must also be observed.
We accept no liability for accidents or damage that occur due to a failure to
observe this manual and the safety instructions.
Device description (Fig. 1 – 14)
1. Carrying handle
2. Tank cover
3. Engine cover
4. Spark plug cover
5. Pull starter
6. Operating display
7. Overload indicator
8. Oil warning indicator
9. USB – connection (2x)| 10. Energy-saving switch (ECO)
11. On/off switch with choke
12. “RESET” button
13. 230 V~ socket (2x)
14. 12 V DC connection
15. 12V DC safety trigger
16. Earthing screw
17. Funnel
18. Spark plug wrench| 19. 12V cable
20. Oil dipstick
21. Air filter cover
22. Air filter
23. Spark plug
24. Spark plug connector
25. Fuel filter insert
26. Fill level marking
---|---|---
Scope of delivery (Fig. 4)
- Power generator/inverter
- Funnel (17)
- Spark plug wrench (18)
- 12 V cable (19)
- Operating manual
Proper use
The power generator is suitable for devices that are intended to operate on a
230 V AC or 12 V DC voltage source.
With household devices and electronic devices, please check the suitability
according to the respective manufacturer’s specifications.
Attention! The power generator must not be connected to the mains supply
as a domestic emergency power supply. It can cause damage to the power
generator or other electrical devices.
The machine may only be used in the intended manner. Any use beyond this is
improper. The user/operator, not the manufacturer, is responsible for damages
or injuries of any type resulting from this. An element of the intended use is
also the observance of the safety instructions, as well as the assembly
instructions and operating information in the operating manual.
Persons who operate and maintain the machine must be familiar with it and must
be informed about potential dangers. In addition, the applicable accident
prevention regulations must be strictly observed. Other general occupational
health and safety-related rules and regulations must be observed.
The liability of the manufacturer and resulting damages are excluded in the
event of modifications of the machine. Please note that our equipment was not
designed with the intention of use for commercial or industrial purposes.
We assume no guarantee if the device is used in commercial or industrial
applications, or for equivalent work.
General safety instructions
We have marked points in the operating manual that impact your safety with
this symbol: m
Furthermore, the operating manual contains other important text sections that
are marked with the word “ATTENTION!”.
Attention!
When using equipment, several safety warnings must be observed to prevent
injuries and damage. For this reason, please carefully read this operating
manual /safety instructions. If the device is handed over to another person,
hand over the operating and safety instructions with it. We accept no
liability for accidents or damage that occur due to a failure to observe this
manual and the safety instructions.
DANGER
A failure to observe these instructions poses an extreme danger of death or
the risk of life-threatening injuries.
WARNING
A failure to observe these instructions poses a danger of death or the risk of
serious injuries.
CAUTION
A failure to observe these instructions poses a minor to moderate danger of
injury.
NOTE!
A failure to observe these instructions poses a risk of damage to the engine
or other property.
-
It is prohibited to make any modifications to the power generator.
-
The manufacturer’s preset speed must not be changed. Power generators or connected devices may be damaged.
-
Danger of poisoning! Exhaust gases, fuel and lubricants are poisonous, exhaust gases may not be inhaled.
-
Fire risk! Petrol and fuel vapours are highly flammable and explosive.
-
Motor exhaust gases are toxic. The power generator must not be operated in unventilated rooms. If the generator is to be operated in well-ventilated rooms, the exhaust gases must be discharged directly outside via an exhaust gas hose. Additional requirements for protection against fire and explosion must also be observed. Toxic exhaust gases can also escape when operating an exhaust hose. Because of the risk of fire, the exhaust hose must never be directed at flammable materials.
-
Never operate the power generator in rooms with highly flammable substances.
-
Hot surfaces! Danger of burning, do not touch suction system and drive unit.
-
Do not touch any mechanically moving or hot parts. Do not remove any protective covers.
-
Protective equipment! Use suitable hearing protection when you are near the device.
-
Only original parts may be used for maintenance and accessories.
-
Repair and adjustment work may only be carried out by authorised specialist personnel.
-
Protect yourself from electrical hazards.
-
Never touch the power generator with wet hands.
-
Only use approved and appropriately identified extension cables for use outdoors (H07RN).
-
If extension leads or mobile distribution networks are used, the resistance value must not exceed Ω. As a guideline value, the total length of lines for a cross-section of 1.5 mm² should not exceed 60 m, and for a cross-section of 2.5 mm², 100 m should not be exceeded.
-
Never operate the power generator during rain or snowfall.
-
Always switch off the engine during transport and refuelling.
-
Fuel is combustible and highly flammable. Do fuel the unit during operation. Do not fuel the unit when someone is smoking or near open flames. Do not spill any fuel.
-
Do not refuel or empty the tank near open light, fire or flying sparks. Smoking prohibited!
-
Do not use the power generator in a thunderstorm.
– Danger of lightning strike! -
Give the power generator a secure, level place. Turning and tilting or changing location during operation are forbidden.
-
Place the power generator at least 1 m away from walls or connected devices.
-
Children must be protected by ensuring that they stay a safe distance away from the inverter power generator.
-
Some parts of the reciprocating internal combustion motor are hot and may cause burns. The warnings on the generator must be observed.
-
Values specified in the technical data under sound power level (LWA) and sound pressure level (LpA) represent emission levels and are not necessarily safe working levels. Since there is a correlation between emission and exposure levels, it cannot be reliably used to determine any additional precautionary measures that may be required.
Factors influencing the current exposure level of the worker include the characteristics of the workspace, other noise sources, airborne noise, etc., such as the number of machines and other adjacent processes and the length of time an operator is exposed to the noise. The permitted exposure level may also vary from country to country. Nevertheless, this information will enable the operator of the machine to make a better assessment of the risks and hazards. If necessary, acoustical measurements should be taken after installation to determine the sound pressure level. -
Warning! Comply with the electrical safety regulations applicable to the place where the inverter power generators are used.
-
Warning! Consider the requirements and precautionary measures in case of re-supply of a system by inverter power generators depending on the protective measures of this system and the applicable directives.
-
Inverter power generators should only be used up to their rated power under the rated ambient conditions. If the inverter power generator is used in conditions that do not comply with the reference conditions according to ISO 8528-8:2016, 7.1, and if the cooling of the engine or generator is impaired, e.g. as a result of operation in restricted areas, a reduction in power is required.
-
Due to high mechanical loads, only durable rubber hose lines (according to IEC 60245-4) or equivalent equipment should be used.
-
Observe the electrical safety regulations applicable to the place where the power generator/inverter is used.
-
Consider the requirements and precautionary measures in case of re-supply of a system by inverter power generators depending on the protective measures of this system and the applicable directives.
Electrical safety
- Prior to use, the generator and its electrical equipment (including lines and plug connectors) should be checked to ensure that there are no defects.
- The power generating unit must not be connected to another power source such as the power supply of energy supply companies. In special cases where a reserve connection to existing electrical systems is provided, this must only be carried out by a qualified electrician who will take into account the differences between the operated equipment using the public mains and operation of the power generating unit. According to this part of ISO 8528, the differences in the operating manual must be specified.
- Protection against electric shocks depends on the circuit breakers which are matched precisely to the power generating unit. If a circuit breaker must be replaced, this should be done using a circuit breaker with the same rating and performance characteristics.
Warning! This power tool generates an electromagnetic field during operation. This field can impair active or passive medical implants under certain conditions. In order to prevent the risk of serious or deadly injuries, we recommend that persons with medical implants consult with their physician and the manufacturer of the medical implant prior to operating the power tool.
ATTENTION: Use only E10 unleaded petrol as fuel.
Use of petrol
****Danger to life! Petrol is toxic and highly flammable.
- Only store petrol in containers (canisters) designed and tested for this purpose. The tank caps must always be properly screwed on and tightened. Defective caps must be replaced for safety reasons.
- Keep petrol away from sparks, open flames, permanent flames, heat sources and other sources of ignition. Do not smoke!
- Refuel outdoors only and do not smoke while refuelling.
- Before refuelling, switch off the combustion engine and let it cool down.
- Petrol must be filled before starting the combustion engine. While the combustion engine runs or if the machine is hot, the fuel cap must not be opened and petrol must not be filled.
- Open the fuel cap carefully and slowly. Wait for the pressure to equalise and only then remove the tank cover completely.
- Use a suitable funnel or filler pipe for refuelling so that no fuel can spill onto the combustion engine and housing or lawn.
- Do not overfill the fuel tank!
- To leave room for the fuel to expand, never fill the fuel tank beyond the lower edge of the filling nozzle. Observe additional information in the combustion engine user manual.
- If petrol has overflowed, do not start the combustion engine until the petrol-contaminated area has been cleaned. Avoid starting the engine until the fuel vapours have evaporated (wipe dry).
- Always wipe up spilled fuel immediately.
- If petrol has got on clothing, it must be changed.
- The tank cover must be properly screwed on and tightened after each refuelling operation. The device must not be put into operation without the original tank cover screwed on.
- For safety reasons, check fuel line, fuel tank, fuel cap and connections regularly for damage, ageing (brittleness), tight fit and leaks and replace if necessary.
- Only empty the tank outdoors.
- Never use beverage bottles or similar to dispose of or store operating materials, such as fuel. People, especially children, could be tempted to drink from it.
- Never store the device with petrol in the tank inside a building. Any fuel vapours produced can come into contact with naked flames or sparks and ignite.
- Do not place the device and fuel tank near heaters, radiant heaters, welding machines or other sources of heat.
Risk of explosion!
If a defect is detected on the tank, the tank cover or on fuel-carrying parts
(fuel lines) during operation, the combustion engine must be switched off
immediately.
Then consult a specialist dealer.
Risk of explosion!
If a defect is detected on the tank, the tank cover or on fuel-carrying
parts (fuel lines) during operation, the combustion engine must be switched
off immediately.
Then consult a specialist dealer.
Residual risks
The electric tool has been built according to state- of-the-art and the
recognised technical safety rules.
However, individual residual risks can arise during operation.
- Health hazard due to electrical power, with the use of improper electrical connection cables.
- Furthermore, despite all precautions having been met, some non-obvious residual risks may still remain.
- Residual risks can be minimised if the “Safety information” and the “Proper use” together with the operating manual as a whole are observed.
- Avoid accidental start-ups of the power generator.
- Use the device in the way that is recommended in this operating manual. This is how to ensure that your power generator provides optimum performance.
Technical data
Power generator | Digital inverter |
---|---|
Protection category | IP23M |
Continuous output Pn (COP)
(230 V) (S1)| 3.0 kW
Max. power Pmax (230 V) (S2 5min)| 3.2 kW
Max. power P peak (230 V) (S2 2s)| 3.5 kW
Rated voltage Un| 230 V~
Rated current In| 2 x 13 A (230 V~)
Rated current In| 8.0 A (12 V)
Rated current In| 2 x 2.1 A (USB)
Frequency Fn| 50 Hz
Performance class| G1
Active power factor φ| 1
Quality class| A
Drive motor type| 4-stroke 1 cylinder air-cooled
Displacement| 141 cm
Max. power (engine)| 3
Fuel| 3.6 kW / 4.8 PS
Tank contents| Super E10 petrol
Engine oil type| 6.3 l
Oil volume (approx.)| 15W40
Consumption at full load| 400 ml
Max. temperature.| 1.78 l/h
Max. altitude| 40 °C
(above mean sea level)| 1000 m
Spark plug| A7RTC
Technical changes reserved!
Operating mode S1 (continuous operation)
The machine may be operated continuously with the specified power.
Operating mode S2 (short-term operation)
The machine may only be operated at maximum or peak power for a brief time.
Noise and vibration
Warning: Noise can have serious effects on your health. If the machine
noise exceeds 85 dB, please wear suitable hearing protection.
Information on noise level per EN ISO 3744:1995, ISO 8528-10:1998
Noise data
Sound power level LWA | 96 dB |
---|---|
Sound pressure level LpA | 74.6 dB |
Uncertainty Kwa/pA | 1.5 dB |
Unpacking
- Open the packaging and carefully remove the device.
- Remove the packaging material, as well as the packaging and transport safety devices (if present).
- Check whether the scope of delivery is complete.
- Check the device and accessory parts for transport damage. In the event of complaints the carrier must be informed immediately. Later claims will not be recognised.
- If possible, keep the packaging until the expiry of the warranty period.
- Familiarize yourself with the device by means of the operating manual before using for the first time.
- With accessories as well as wearing parts and spare parts use only original parts. Spare parts can be obtained from your specialist dealer.
- When ordering please provide our article number as well as type and year of manufacture for your equipment.
WARNING!
The device and the packaging material are not children‘s toys! Do not let
children play with plastic bags, films or small parts! There is a danger of
choking or suffocating!
Before commissioning
Electrical safety
Prior to use, the power generator and its electrical equipment (including
lines and plug connectors) should be checked to ensure that there are no
defects.
Never connect the power generator to the mains (socket).
The power lines to the consumer must be kept as short as possible.
**DANGER!
Risk of fire and explosion!
**When filling, fuel may ignite and even explode. This can lead to severe
burns or death.
- Switch off the engine and let it cool down.
- Keep heat, flames and sparks away.
- Only fill up with fuel outdoors.
- Wear protective gloves.
- Avoid contact with skin and eyes.
- Start the device at a distance of at least 3 m from the fuel filling point.
- Watch out for leaks. If petrol is leaking, do not start the engine.
WARNING!
Health hazard!
Inhaling petrol/lubricant vapours may lead to severe health damage, loss of
consciousness and, in extreme cases, to death.
- Do not inhale petrol/lubricant vapours.
- Operate the device outdoors only.
NOTE!
Device damage
Using the device without or with too little engine and gearbox oil can
result in engine damage.
- Fill with petrol and oil before commissioning. The device is supplied without engine and gearbox oil.
NOTE!
Environmental damage!
Spilled oil can pollute the environment permanently.
The liquid is highly toxic and can quickly lead to water pollution.
- Fill/empty oil only on level, paved surfaces.
- Use a filling nozzle or funnel.
- Collect drained oil in a suitable container.
- Wipe up spilled oil carefully immediately and dispose of the cloth according to local regulations.
- Dispose of oil as per local regulations.
8.1 Earthing (Fig. 3)
A Attention! Electric shock!
- Do not use bare wires for earthing.
- Power generator must be safely earthed.
Earthing the housing is necessary to discharge static charging. To do this, connect a cable on one side to the earth terminal (16) of the power generator and on the other side to an external mass rising pipe (e.g. rod earth).
ATTENTION!
Check before operation
- Check all sides of the engine for oil or fuel leaks.
- Check the engine oil level.
- Check the fuel level — Fill with at least 2 litres of Super E10 petrol.
- Check the condition of the air filter.
- Check the condition of the fuel lines.
- Look for signs of damage.
- Check that all protective covers are in place and all screws are tightened.
- Ensure that the device is sufficiently ventilated.
- Make sure that the spark plug connector is attached to the spark plug (23).
- Disconnect any connected electrical devices from the power generator.
8.2 Top up oil (Fig. 7 + 8)
**Attention!
** The power generator is delivered without engine oil. Therefore, ensure that
you add oil before starting it up. Use 15W40 oil here.
Check the oil level regularly before commissioning. An oil level that is too
low can damage the engine.
-
Place the power generator on a level, even surface.
-
Remove the engine cover (3) by unscrewing the two screws with a Phillips screwdriver (not included in the scope of delivery).
-
Unscrew the oil dipstick (20).
-
Fill the tank with engine oil using a funnel (17).
Note the max. filling capacity of 400 ml. Carefully fill the oil up to the lower edge of the filling port. 5. Wipe the oil dipstick (20) with a clean, lint-free cloth. -
Re-insert the oil dipstick (20) and check the oil level without screwing the dipstick tight again.
-
The oil level must be within the middle mark on the oil dipstick.
-
If the oil level is too low, add the recommended amount of oil (max. 400 ml).
-
Then screw the oil dipstick (20) in again.
-
Put the engine cover (3) on and fix in place by retightening the two screws.
8.3 Refill with fuel
Attention!
The power generator is delivered without petrol. It is therefore essential to
fill with petrol before commissioning. Use Super E10 petrol for this.
-
Unscrew the tank filler cap (2) and fill a maximum of 6.3 l Super E10 petrol into the tank container using the funnel (17).
-
Ensure that the tank is not overfilled (observe the fill level marking (26)!) and that no petrol is spilled.
Use a fuel filter insert (25). Clean up spilled petrol immediately and wait until the fuel vapours have evaporated (wipe dry). -
Close the tank cover (2).
ATTENTION!
Refuel in a well-ventilated area with the engine stopped.
If the engine was in operation immediately before, allow it to cool first.
Never refuel the engine in a building where the petrol vapour may come into
contact with flames or sparks.
Petrol is highly inflammable and explosive. When handling fuels, you may
suffer burns or other severe injuries.
Operation
Attention!
Always make sure the device is fully assembled before commissioning!
9.1 Starting the engine (Fig. 5 + 6)
Attention! Danger of poisoning!
Only use the device outdoors and never in closed or poorly ventilated rooms.
- Set the ventilation on the tank cover (2) to “ON”.
- Set the on/off switch (11) to the “RUN” position.
Note: The energy saving switch (10) must be set to “OFF”.
When the engine is cold
- Attention! Never allow the pull starter (5) to whip back. This can result in damage.
- Set the on/off switch (11) to the “CHOKE?” position.
- Now pull the pull starter (5) and the engine should start. If the engine does not start, repeat the process.
- Move the on/off switch (11) from the “CHOKE” position to the “RUN” position after starting the engine (after approx. 15-30 seconds). (Fig. 6)
- If the engine does not start even after several attempts, read the “Troubleshooting” chapter.
Note:
If the engine is being started for the first time, several tries are
required to start until the fuel has been delivered from the tank to the
engine.
Note: With high outside temperatures, it may be necessary to start the
power generator without the choke even when the engine is cold!
When the engine is warm
- Set the on/off switch (11) to the “RUN” position.
- Now pull the pull starter (5) quickly. The device should start after a maximum of 2 pulls. If the device has still not started, repeat the procedure described under “Starting the engine when cold”.
9.2 Shutting the engine off
Allow the power generator to run for a short time (approx. 30 seconds)
without load before switching it off so that it can “cool down”.
- Set the on/off switch (11) to the “OFF” position.
- Disconnect the power consumers from the device.
- Set the ventilation on the tank cover (2) to “OFF”.
9.3. Operating display (6) (Fig. 3)
The operating display (6) is active when the engine is running.
9.4 Overload indicator (7) (Fig. 3)
The overload protection becomes active if the power consumption is too high
and switches off the 230 V ~ sockets (13).
- Switch the device off as described in section 9.2.
- Disconnect the power consumers from the device.
9.5 “RESET” button (12) (Fig. 3)
If the overload protection has been triggered and the overload indicator
(7) lights up red, the “RESET” button (12) can restore the output power of the
power generator/inverter. It is then not necessary to restart the engine.
- Press and hold the “RESET” button (12) for 1 second until the light (red) is extinguished and the operation indicator (6) (green) illuminates.
If the overload protection has not tripped, the “RESET” button (12) has no effect.
9.6 Oil warning indicator (8) (Fig. 3)
The indicator activates when the oil level is too low and deactivates as
soon as the oil level is sufficient.
9.7 Automatic oil cut-off
The automatic oil cut-off system responds when there is too little engine
oil. The oil warning indicator (8) starts flashing when there is too little
oil in the engine. The indicator lamp starts to light up when the oil quantity
has not reached the safety quantity. The engine switches itself off after a
short time. It is not possible to start the engine until the engine oil has
been filled (see chapter 8.2).
The indicator activates when the oil level is too low and deactivates as soon
as the oil level is sufficient. If the oil level is too low, the oil warning
indicator (8) lights up during the start attempt. Top up engine oil as
described in 8.2 and repeat the starting procedure.
9.8 Energy saving switch (10) (Fig. 3)
To reduce the fuel consumption when idle, move the energy saving switch
(10) to the “ON” position. The energy saving switch (10) must be switched off
when electrical devices that require a high starting current are connected,
for example a compressor. Even when the power generator is started, the energy
saving switch must be initially set to “OFF”.
9.9 USB connection (9) (Fig. 3)
This power generator is equipped with two USB connections. These can be
used to charge smartphones for example.
9.10 Charging external devices (Fig. 3)
DANGER!
Danger due to incorrect charging.
- Plug the adapter cable with 12 V terminals (19) into the 12 V DC connection (14) provided for this.
- If the 12 V DC safety release (15) has been tripped, the 12 V DC safety release (15) can restore the output power of the inverter power generator. Press and hold the 12 V DC safety release button (15) for 1 second.
- If the 12 V DC safety release (15) has not been triggered, the 12 V DC safety release (15) is ineffective.
Cleaning and maintenance
Before carrying out any cleaning or maintenance work, switch off the engine and remove the spark plug connector (24) from the spark plug (23).
ATTENTION! Danger of burning! Wait until the device has cooled down before performing cleaning or maintenance work.
10.1 Cleaning
Keep protective devices, air vents and the motor housing as free of dust
and dirt as possible. Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure. We recommend that you clean the device
directly after every use.
Clean the device at regular intervals using a damp cloth and a little soft
soap. Do not use any cleaning products or solvents; they could attack the
plastic parts of the device. Make sure that no water can penetrate the device
interior.
10.2 Maintenance
WARNING!
Always wear protective gloves and a mask during maintenance work!
10.2.1 Checking the oil level
- Proceed as described in 8.2.
10.2.2 Changing oil (Fig. 7 + 8)
Change the engine oil after 20 operating hours, then after 50 hours or
every three months.
The engine oil change should be carried out while the engine is at operating
temperature.
- Place the power generator on a level, even surface.
- Remove the engine cover (3) as described in 8.2. (Fig. 7)
- Provide a collection container (not included in the scope of delivery).
- Open the oil dipstick (20) and drain warm engine oil into the collection container by tilting the power generator.
- Fill up with new engine oil (approx. 0.35 |).
- Screw the oil dipstick (20) in again.
- Dispose of the used oil properly.
10.2.3 Air filter (Fig. 9 + 10)
NOTE!
Risk of damage!
Operating the engine without a filter element or with a damaged filter
element can cause engine damage.
- Never run the engine without the air filter element or with a damaged filter element. This would allow dirt into the engine, which would result in severe damage to the engine.
Clean the air filter (22) every 50 operating hours, replace if necessary.
- Remove the engine cover (3) (Fig. 7).
- Remove the air filter cover by pressing the fastening tabs on the side.
- Remove the air filter (22).
- Do not use harsh cleaners or petrol to clean the filter.
- Clean the elements by knocking them out on a flat surface. If heavily soiled, wash with soapy water, then rinse with clean water and allow to air dry.
- The re-assembly takes place in reverse order.
10.2.4 Spark plug (Fig. 11 + 12)
ATTENTION: Only replace the spark plug when the engine is cold!
Check the spark plug (22) for contamination for the first time after 20
operating hours and clean it with a copper wire brush if necessary. Then
maintain the spark plug (22) every 50 operating hours.
- Open the spark plug cover (4).
- Pull off the spark plug connector (24) with a twisting motion.
- Remove the spark plug (23) with the enclosed spark plug wrench (18).
- Remove any dirt from the base of the spark plug (23).
- Visually inspect the spark plug (23). Remove any deposits present using a wire brush.
- Check the spark plug gap. Set the electrode gap to 0.6 to 0.7 mm with a feeler gauge.
- The re-assembly takes place in reverse order.
NOTE
A loose spark plug can overheat and cause damage to the engine. Tightening
the spark plug too much can damage the thread in the cylinder head.
10.2.5 Clean the fuel filter insert (Fig. 13 + 14)
Note: The fuel filter insert (25) is a filter cup which is located directly
under the tank cover (2) and filters all the fuel filled in.
- Set the on/off switch (11) to the “OFF” position.
- Open the tank cover (2).
- Remove the fuel filter insert (25) and the fill level marking (26). Clean it in a non-flammable solvent or a solvent with a high flash point.
- Reinsert the fuel filter insert (25) with the fill level marking (26).
- Close the tank cover (2).
Please provide the following information in the event of any enquiries:
- Machine data – type plate
- Engine data – type plate
Important note in the case of repairs:
For return delivery of the device for repair, please ensure for safety
reasons that it is free of oil and fuel when it is sent to the service centre.
10.3 Ordering spare parts
Please provide the following information when ordering replacement parts:
- Device type
- Device article number
Service information
With this product, it is necessary to note that the following parts are
subject to natural or usage-related wear, or that the following parts are
required as consumables.
Wearing parts: Spark plug, air filter may not be included in the scope of
delivery!
Spare parts and accessories can be obtained from our service centre. To do
this, scan the QR code on the cover page.
Storage
11.1 Preparation for storage
-
Empty the fuel tank using a petrol extraction pump (see section 11.2).
Warning: Do not remove the petrol in enclosed spaces, near fire or when smoking. Petrol fumes can cause explosions and fire. -
Change the oil at the end of every season.
-
To do so, remove the used engine oil from a warm engine and refill with fresh oil.
-
Remove the spark plug (23). (Fig. 12)
-
Fill the cylinder with approx. 20 ml of oil from an oil can.
-
Pull the start pull cord slowly so that the oil protects the inside of the cylinder.
-
Screw the spark plug (23) back in.
-
Store the device in a well-ventilated place or area.
11.2 Drain petrol with a petrol extraction pump
In case of storage over a longer period of time, the petrol must be
drained.
- Hold a collection container under the hose of the petrol extraction pump (not included in the scope of delivery).
- Unscrew and remove the tank filler cap (2).
- Remove the fuel filter insert (24).
- Push the hose of the petrol suction pump into the fuel tank and drain the petrol completely using the petrol extraction pump.
- Reinsert the fuel filter insert (24).
- Retighten the fuel filler cap (2).
Transport
- Empty the fuel tank using a petrol extraction pump (see section 11.2).
- If operational, keep the engine running until the remaining petrol has been used up.
- Drain the engine oil from the warm engine (as described under 10.2.2 Oil change).
- Remove the spark plug connector (24) from the spark plug (23).
- Secure the device against slipping using a tension strap, for example.
- The power generator can be lifted and moved via the handle (1).
Disposal and recycling
Notes for packaging
The packaging materials are recyclable. Please dispose of packaging in an
environmentally friendly manner.
Notes on the electrical and electronic equipment act [ElektroG]
Waste electrical and electronic equipment does not belong in household waste,
but must be collected and disposed of separately!
- Used batteries or rechargeable batteries that are not installed permanently in the old appliance must be removed non-destructively before disposal. Their disposal is regulated by the battery law.
- Owners or users of electrical and electronic devices are legally obliged to return them after use.
- The end user is responsible for deleting their personal data from the old device being disposed of!
- The symbol of the crossed-out dustbin means that waste electrical and electronic equipment must not be disposed of with household waste.
- Waste electrical and electronic equipment can be handed in free of charge at the following places:
- Public disposal or collection points (e.g. municipal works yards)
- Points of sale of electrical appliances (stationary and online), provided that dealers are obliged to take them back or offer to do so voluntarily.
- Up to three waste electrical devices per type of device, with an edge length of no more than 25 centimetres, can be returned free of charge to the manufacturer without prior purchase of a new device from the manufacturer or taken to another authorised collection point in your vicinity.
- Further supplementary take-back conditions of the manufacturers and distributors can be obtained from the respective customer service.
- If the manufacturer delivers a new electrical appliance to a private household, the manufacturer can arrange for the free collection of the old electrical appliance upon request from the end user. Please contact the manufacturer’s customer service for this.
- These statements only apply to devices installed and sold in the countries of the European Union and which are subject to the European Directive 2012/19/EU. In countries outside the European Union, different regulations may apply to the disposal of waste electrical and electronic equipment.
You can find out how to dispose of the disused device from your local authority or city administration.
Fuels and oils
- Before disposing of the unit, the fuel tank and the engine oil tank must be emptied!
- Fuel and engine oil do not belong in household waste or drains, but must be collected or disposed of separately!
- Empty oil and fuel tanks must be disposed of in an environmentally friendly manner.
Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault | Possible cause | Remedy |
---|---|---|
Engine cannot be started | Automatic oil cut-off starts | Check oil level, fill |
with engine oil
Spark plug sooty| Clean or replace spark plug
No fuel| Top up with fuel
Generator has insufficient or no voltage| Electronics defective| Repair by an
authorized service centre.
Overload protection switch tripped| Restart the power generator, reduce
consumers
Air filter dirty| Clean or replace filter
Maintenance plan
Always comply with the following maintenance intervals in order to ensure
problem-free operation.
ATTENTION! At initial start-up, engine oil and fuel must be filled.
| Before every use| after operating for 20 hours| after operating for 50
hours| after operating for 300 hours
---|---|---|---|---
Checking the engine oil| X| | |
Changing the engine oil| | first time, then every 50 hours| X|
Checking the airfilter| X| | | Change filter insert if necessary
Cleaning the air filter| | | X|
Visual inspection of the device| X| | |
Cleaning the spark plug| | | Gap: 0.6 – 0.7 mm, replace if necessary|
Check and readjust the throttle valve| | X| |
Cleaning the cylinder head| | | | X
Adjust the valve play| | | | X*
Attention: Only have points “X” carried out by an authorized specialist
company.
EC Declaration of Conformity
hereby declares the following conformity under the EU Directive and standards for the following article
Marke : | SCHEPPACH |
---|---|
Art.-Bezeichnung: | INVERTER STROMERZEUGER – SG3500I |
Article name: | INVERTER GENERATOR – SG3500I |
Nom d’article: | GÉNÉRATEUR ÉLECTRIQUE À INVERTER – SG3500I |
Art.: | 5906230903 |
2014/29/EU | 2004/22/EG |
--- | --- |
2014/35/EU | 2014/68/EU |
x 2014/30/EU | x 2011/65/EU* |
x 2006/42/EG |
Annex IV
Notified Body:
Notified Body No.:
Certificate No.:
x 2000/14/EG_2005/88/EG
Annex V
Annex VI
X Noise: measured LWA= 94,7 dB; guaranteed LWA= 96 dB
P = 3,6 KW
Notified Body: TÜV Rheinland LGA Products GmbH,
Tillystraße 2, 90431 Nürnberg
Notified Body No.: 0197
x 2016/1628/EU
Emission. No: e242016/16282021/1398SRA1/P055400
Standard references:
EN ISO 8528-13:2016; EN 55012:2007+A1; EN 61000-6-1:2007; EN ISO 3744:1995;
ISO 8528-10:1998
Declaration of conformity
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
The object of the declaration described above fulfils the regulations of the directive 2011/65/EU of the European Parliament and Council from 8th June 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Ichenhausen, 23.12.2022
First CE: 2022
Subject to change without notice
Documents registrar: Sebastian Katzer
Günzburger Str. 69, D-89335 Ichenhausen
Warranty
Apparent defects must be notified within 8 days from the receipt of the goods. Otherwise, the buyerís rights of claim due to such defects are invalidated. We guarantee for our machines in case of proper treatment for the time of the statutory warranty period from delivery in such a way that we replace any machine part free of charge which provably becomes unusable due to faulty material or defects of fabrication within such period of time. With respect to parts not manufactured by us we only warrant insofar as we are entitled to warranty claims against the upstream suppliers. The costs for the installation of the new parts shall be borne by the buyer. The cancellation of sale or the reduction of purchase price as well as any other claims for damages shall be excluded.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>