SENSeOR UM00401 24/7 Asset Monitoring Solution Energy User Manual

June 13, 2024
SENSeOR

SENSeOR UM00401 24/7 Asset Monitoring Solution Energy

Product Information

The SENSeOR Datamatrix to XML is an asset monitoring solution for energy systems. It allows users to generate XML files from the Datamatrix located on the top of the TSA-EV11 temperature sensors. These XML files can be used with the ‘SENSeOR Configuration Tool’ applications.

Warranty

These products are warranted to be free from functional defects in material and workmanship at the time of manufacturing. The warranty period is one year from the date of purchase. Please refer to SENSeOR terms and conditions provided at the time of purchase
for complete warranty details.

Safety Information

  • DANGER: Indicates an imminently hazardous situation that could result in death or serious injury if not avoided.
  • WARNING: Indicates a potentially hazardous situation that could result in death or serious injury if not avoided.
  • CAUTION: Indicates a potentially hazardous situation that may result in minor or moderate injury if not avoided.
  • NOTICE: Provides guidance on damage unrelated to personal injury, such as property damage.
  • IMPORTANT: Provides additional information about making effective use of the product.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG1

WARRANTY

These products are warranted to be free from functional defects in material and in workmanship at the time of the manufacturing and to conform at that time to the specifications set forth in the relevant instruction manuals or in the data sheets, for such products for a period of one year.
Reference SENSeOR terms and conditions provided at time of purchase for complete warranty details.

SENSeOR (head office)
Bâtiment Natura 2
1198, avenue du Docteur Maurice Donat
06250 Mougins
France

SENSeOR reserves the right to make technical changes or to modify the content of this document without prior notice. SENSeOR is not responsible for errors or for possible lack of information in this document. All rights reserved. No part of this document may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, without the prior written permission of SENSeOR, except in the case of brief quotations embodied in critical reviews and certain other non-commercial uses permitted by copyright law.
Copyright © 2023, SENSeOR

SENSeOR Datamatrix to XML User Manual www.senseor.com

SAFETY INFORMATION

IT IS IMPORTANT TO READ THIS MANUAL BEFORE INSTALLING OR COMMISSIONING SENSEOR CRITICAL ASSET MONITORING SYSTEMS.

DANGER
DANGER INDICATES AN IMMINENTLY HAZARDOUS SITUATION, WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.
FAILURE TO FOLLOW THE INSTRUCTIONS GIVEN WILL RESULT IN DEATH OR SERIOUS INJURY.

WARNING

WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION, WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR SERIOUS INJURY.
FAILURE TO FOLLOW THE GIVEN INSTRUCTIONS CAN RESULT IN DEATH OR IN SERIOUS INJURY.

CAUTION

CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION, WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN PERSONAL INJURY.

NOTICE

NOTICE PROVIDES GUIDANCE ON DAMAGE UNRELATED TO PERSONAL INJURY, SUCH AS THOSE THAT CAN CAUSE DETERIORATED PROPERTY.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN PROPERTY DAMAGE.

IMPORTANT

IMPORTANT INDICATES ADDITIONAL INFORMATION ABOUT MAKING EFFECTIVE USE OF THIS PRODUCT.

OVERVIEW

This user manual describes how to use the SENSeOR Datamatrix to XML to generate XML files from the Datamatrix located of the top of the TSA-EV11 temperature sensors.

This manual provides user guidelines for version 1.0.0.
The XML files generated by the application will then be used for the ‘SENSeOR Configuration Tool’ applications.

SOFTWARE INSTALLATION

OPERATING SYSTEM
The SENSeOR Datamatrix to XML operates only on Microsoft Windows operating system, with at least Windows 10.

SOFTWARE INSTALLATION
To install SENSeOR Datamatrix to XML, extract the ‘Datamatrix to XML vX.X.X.zip’ zipped files. It contains two files: ‘SENSeOR.cer’ and ‘Datamatrix to XML vX.X.X.appxbundle’.

NOTE

THE LAST REVISION OF THE SOFTWARE IS AVAILABLE ON THE SENSEOR WEBSITE.

‘SENSEOR’ CERTIFICATE INSTALLATION

Right click on the ‘SENSeOR.cer’ file and select ‘Install Certificate’ menu.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG2

Click on the ‘Open’ button to allow the ‘Security Warning’.

The ‘Certificate Import Wizard’ opens.
Select ‘Local Machine’ as Store Location and click on ‘Next’ button.

MONITORING SOLUTION ENERGY

MONITORING SOLUTION ENERGY
Validate ‘Administrator mode approval’ window and select ‘Place all certificates in the following store’.
Click on ‘Browse’ button, select ‘Trusted Root Certification Authorities’ and click on ‘OK’ button.

Click on ‘Next’ button and then ‘Finish’ button to import certificate.

Click on ‘OK’ to confirm the ‘SENSeOR certificate’ installation.

NOTE

ADMINISTRATOR RIGHTS ARE REQUIRED TO INSTALL APPLICATION.

APPLICATION INSTALLATION

Double click on ‘Datamatrix to XML vX.X.X.appxbundle’ file to launch ‘App installer’.

Click on ‘Install’ button to start installation.

NOTE
AT EACH LAUNCH, THE APPLICATION WILL AUTOMATICALLY CHECK FOR UPDATES.

APPLICATION LAUNCH

The SENSeOR Datamatrix to XML installation creates a shortcut with the same name in the Windows menu. Click on it to launch the program.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG10

SOFTWARE STARTUP

At start-up, the application sets the default ‘Output directory’ path to ‘Current user\Documents\SENSeOR\Sensor data’.
As its name suggests, this directory will host all the sensor XML files created.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG11

To select another output directory, click on the ‘Browse’ button.

SENSOR XML FILES GENERATION

GENERATING XML FILES FROM AN INPUT TEXT FILE

CREATING THE INPUT TEXT FILE
To automatically generate several XML files, simply import a text file containing the data to be converted.
To create this input file, you can use the Windows ‘Notepad’ application (or any other text editor) and save it as a text file. Its name, encoding format and saving directory do not matter.
Each line of the file represents a sensor.
To add new data to it, you can use free mobile apps such as ‘CortexScan’ or ‘QRbot’ (available from ‘App Store’ and ‘Google Play’), scan the sensor’s radome Datamatrix (of the top of sensor) and paste string data.
Here is an example of a text file created called ‘Sensors’ and containing 20 sensors.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG12NOTE
THERE IS NO LIMITATION ON THE NUMBER OF SENSORS TO CONVERT.

IMPORT OF THE CREATED TEXT FILE
Click on the ‘Open file’ button and browse the created text file.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG13

Click on ‘Open’. The application will load the content of the file into the ‘Data to convert’ text box and the text file path in the ‘Input file path’ text box.
Once data conversion is done, a message indicates how many XML files have been generated.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG14

By clicking on the ‘OK’ button, the application is ready to start a new conversion.
By clicking on the ‘Open output directory’ button, the previous ‘Data to convert’ content is cleared and the application launches Windows explorer to view created files.

GENERATING XML FILES FROM LIVE DATA
The other way to generate the sensor XML files is to directly paste the radome Datamatrix (located of the top of the sensor) data into the ‘Data to convert’ text box.
To do this, you can use a Datamatrix-compatible USB scanner like this one.

To add new data, click on the ‘Data to convert’ text box and scan as many Datamatrix as needed. Line wrap is automatic after each scan.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG16

When all the sensors are scanned, click on the ‘Convert’ button to start conversion.

Once data conversion is done, a message indicates how many XML files have been generated.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG17

By clicking on the ‘OK’ button, the application is ready to start a new conversion.
By clicking on the ‘Open output directory’ button, the previous ‘Data to convert’ content is cleared and the application launches Windows explorer to view created files.

TROUBLESHOOTING

UNABLE TO INSTALL APPLICATION
If the following window appears, it means that the ‘SENSeOR certificate’ is not correctly installed.

To fix it, please refer to chapter ‘SENSeOR’ certificate installation and try again to install ‘Datamatrix to XML’.

UNABLE TO SET THE ‘OUTPUT DIRECTORY’
At application startup, if the following window appears, it means that the ‘Documents library access’ is disabled.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG19

To fix it, enable ‘Documents library access’ from ‘Privacy and security’ Windows settings.

SENSeOR UM00401 24-7 Asset Monitoring Solution Energy-
FIG20

SENSeOR Datamatrix to XML User Manual www.senseor.com

SENSeOR (head office)
Bâtiment Natura 2 1198, avenue du Docteur Maurice Donat 06250 Mougins France

Contact address:
support.senseor@wika.com

Regional distributors
Visit www.senseor.com for the latest distribution locations.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals