Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter Owner’s Manual
- June 13, 2024
- Baintech Power Products
Table of Contents
OWRNER’S
MANUAL
Pure Sine Wave Inverter
DC-AC Power Inverter
Special Feature:
- Remote control(Optional)
- Power ON-OFF switch
- USB:5V,2.1A
- Two multiple controlled DC fans:Temperature and load.
- Protection:LED Indicator&Audible Alarm.
- Output wave form: Pure Sine Wave
- CE and RoHS Approved
Congratulationsand thank you for purchasing our pure sine wave inverter.Carefully read,understand and comply with all instructions before use.
INTRODUCTION
1.1 What is an Inverter?
Power inverter is an electronic device that convert DC(Direct Current) battery
power to standard AC (Alternating Current) power. DC is the power that is
produced by battery while AC is the standard power needed to run electrical
equipment. A power inverter does the opposite of a rectifier and is used in
places and situations where AC power is not available.
1.2 Pure Sine Wave Inverter If you want
to run your equipment exactly to the manufacturer’s specifications, choose a
pure sine wave inverter. With pure sine wave, motor loads start easier and run
cooler. Some equipment only operate properly with pure sine wave inverter,
such as laser printers, variable speed motors and digital clocks.
MAIN COMPONENTS
2.1 Front Panel
The front panel view shows the inverter’s ON/OFF Switch, AC Output Receptacle,
LED Indicator Light, Vent Outlet, Remote Control port ,Chassis Ground,USB.
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
- assembly 2](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power- Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-assembly-2.jpg)
A. ON/OFF Switch.
This switch controls ON/OFF operation of the inverter.
B.LED Indicator Light:
Fault, Inverter.
a) Fault: Turns Red shows fault, reference to Troubleshooting
b)Inverter: This light will illuminate continuously whenever connected
equipment is receiving battery-supplied, inverted AC power.
C. AC Output Receptacle:
For application demands of different geographic areas all over the world,
there are many different kinds of optional AC receptacle to choose from.
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
- assembly 3](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power- Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-assembly-3.jpg) D. Vent Outlet.
To decrease the temperature of the inverter.
E. Chassis Ground
Properly grounds the Inverter to vehicle grounding system or to earth ground.
F. Remote Switch Port(Optional):
Use to connect the remote ON/OFF switch via a communication cable. Refer to
Appendix C. Hardwire Terminal Block(4000W to 6000W):
Note: When the load current is >ISA, must use output terminal connection
which can be found inside the AC output panel of the inverter.
** Ensure the inverter is turned off if connecting the Hard Wire option.
Seek professional assistance if you are unfamiliar with electrical
wiring. H. USB Port(Optional):
Powers and charges USB-enabled devices.
2.2 Rear Panel
The rear panel view shows the inverter’s Cooling fan, DC Battery Terminals,
Fuse A. Temperature and Load controlled Cooling Fan
Quiet, efficient fan prolongs equipment service life.
Load >20% or inner temperaturp is more than 45°C, the Fan will start work
B. DC Battery Terminals
Connect the inverter to battery or other power sources.
Negative (-) and Positive (+) DC terminals should be kept insulated to protect
from accidental short circuits.
a) Connect the black cable to the black post marked (-) on the back of the
inverter. Connect the other end to the negative terminal on the battery.
b) Connect the red cable to the red post marked (+) on the back of the
inverter. Connect the other end to the positive terminal on the battery.
If you connect the cables to the incorrect terminals, you will reverse the
polarity and damage the inverter.
APROHIBITED REVERSE POLARITY.**
DAMAGE CAUSED BY REV ERSE POLARITY WILL NOT BE COVERED BY WARRANTY.
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
-
assembly 6](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power- Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-assembly-6.jpg) Amps x AC voltage = Watts
This formula yields an approximation of the continuous wattage load of that appliance.
The startup load of an appliance is a major factor of whether this inverter can power it. Startup load is momentary. With many appliances, it is approximately twice the continuous load, but some appliance startup loads can be as high as eight times the continuous load.
To determine if an appliance or tool will operate with this inverter, run a test. This inverter will automatically shut down in the event of an output overload, so there is no danger of damaging either the inverter or the equipment. When lit, a red LED indicator and Buzzer signals a fault.
3.2 Configuring the Battery Bank
To determine the minimum battery ampere-hour rating that you will need to operate appliances from the inverter and any DC appliances powered by the battery bank, follow these steps:- List the maximum continuous wattage that the inverter has to supply.
- Estimate the number of hours the appliances will be in use between battery recharges. This will vary depending on appliances. For example, a typical home-use coffee maker draws 500 watts during its brew time of 5 minutes. It maintains the temperature of the pot, requiring 100 watts. Typical use of a microwave oven is only for a few minutes. Some longer operating time appliances are lamps, TVs, computers and refrigerator/freezers.
Determine the total watt-hours of energy needed. This is done by multiplying average power consumption in watts by hours of run time. For example: 500 watts for 10 hours = 5000 watt hours. To get an estimate of the maximum current (in amps) that a battery bank must be capable of delivering to the inverter, divide the load watts by ten. For example a 500 watt appliance load will need 50 amps at 12 volts DC. Using the 500 watts (or 50 amps) for 10 hours example as above, then 50 amps is needed for 10 hours. This provides us with the basic amp-hours (AH) of battery that is required. Ten hours at 50 amps equals 500 amp-hours (AH). There are additional factors that determine actual run time. These include:
- AC appliance load and time in use (basic AH).
- Cable gauge and length (cable losses).
- Charge level of the batteries (between use, chargers have to be able to fully charge the batteries).
- Temperature of the batteries (colder batteries provide fewer amps).
- Age and condition of the batteries (older batteries lose AH capacity).
- Compliance with turning off unnecessary AC loads.
- Use of DC appliances and compliance with turning off unnecessary DC loads.
3.3 Battery Wiring Examples
In renewable energy systems, batteries are connected to each other in one of
three ways:
- Series (voltage increases, amperage stays the same as a single battery)
- parallel (voltage stays the same as a single battery, amperage increases)
- Series/Parallel (both voltage and amperage increase)
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
- assembly 7](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power-
Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-
assembly-7.jpg)Two strings of batteries In series are connected In parallel
The voltage increases to 48V and the amp hours Increase to 400
3.4 Placement of inverter
The location where to install inverter must be:
A. Dry: Do not allow water to drip or splash onto it.
B. Cool: Ambient air temperature should be between 0° C and 40° C – ideally between 15° C and 25°.Do not place the inverter on or near a beating vent or any piece of cquipment which is generating heat above room temperature. Do not place the inverter in direct sunlight unnecessarily.
C. Ventilated: Allow at least one inch of clearance around the unit for air flow. Do not place items on or over the inverter during operation. Make sure that air is allowed to circulate freely around the unit. A fan is helpful in the case where the inverter is operating at maximum
D. Safe: Do not install the inverter in the same compartment as the batteries or in any compartment where flammable liquids or fumes may be or may become present.
E. Dust Do not install the inverter in a dusty environments. The dust can be inhaled into the unit when the cooling fan is working.
F. Close to batteries: excessive cable lengths. Do not install the inverter in the same
3.5 Mounting position of the inverter
The inverter may be mounted horizontally on the top of a horizontal surface or under a horizontal surface. The inverter may be mounted on a vertical surface only horizontally.
3.6 Getting Connected
Follow the connection sequence described below.
Step 1 Ensure that tbe ON/OFF switch on the Inverter is in the OFF position. If the power source is a DC power supply, switch it OFF as well.
Step 2 Connect inverter to power source.
Connect the DC cables to the DC battery terminals on the rear panel of the inverter. The red terminal is positive (+) and the black terminal is negative (-).
Step 3 Connect inverter to appliances.
Make sure the foad power within the rated power of inverter and the start power should not exceed the peak power of the inverter. When having the inverter connected with appliances and a power supply, switch on the inverter and appliances. If you are operating several Ioads from the power inverter, turn them on separately after the inverter has been tumed on. This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once.
MPORTANT SAFETY INSTRUCTIONS
Incorrect installation and misuse of the inverter may result in danger to the user or hazardous conditions.
- Do not attempt to connect the any other power source, including any AC power source .
- Make sure the opening to the ventilation fan and vent holes are not blocked.
- Avoid pulling on the cords and cables. Always grip plugs firmly when unplugging from power source and when disconnecting cables.
- To avoid electrical hazard, be sure to unplug the inverter from its external power source before inserting the AC plug.
- For indoor use only. Avoid exposure to external heat sources; direct, prolonged sunlight; dust; corrosive chemicals; and moisture.
- It is normal for inverters to become warm during use. Avoid touching the device during use. Avoid placing in direct sunlight or near heat-sensitive materials.
- Do not drop or subject the inverter to undue shock.
- Do not place anything on top of the inverter.
- Always with the supplied cables and connectors as shown. Use of cables, connectors, or accessories not supplied with this product constitutes misuse and may result in injury or damage.
- Do not attempt to service or dissemble. The unit is not user-serviceable. Attempting to disassemble or service the unit can result in electrical hazard, including death from exposure to high voltage. If you experience problems with the unit, discontinue use and Contact Technician.
- When cleaning the inverter, please switch off power(unplug the inverter).Carefully clean with dry cloth. Do not use wet cloth or cleanser.
- Disconnect all AC and DC side connections before working on any circuits associated with the inverter. Turning the ON/OFF switch on the inverter to off position may not entirely remove dangerous voltage.
- Keep away from children.
PROTECTION FEATURE
Inverter is equipped with numerous protection features to ensure safe
operation.
Input Low Voltage Protection:
A: When battery voltage is below 10.5V +0.5V(for 12V input inverter)/21.0V +
1.0V(for 24v input inverter)/ 42.0V % 2.0V(for 48V input inverter), Buzzer
sound 2times. which indicates DC power supply voltage is descending and
batteries need to recharge.
B: When input voltage is below 10.0V 0.5V (for 12V input inverter)/20.0V =
1.0V(for 24V input inverter)/ 40.0V & 2.0V(for 48V input inverter), Buzzer
sound 3 times and red light turn on, AC output will be automatically shut off.
Input Over Voltage Protection
When input voltage reach 16.0V & 0.5V (for 12V input inverter)/32V + 1.0V (for
24V input inverter)/64V = 2.0V (for 48V input inverter), Buzzer sound 4times
and red light turn on, the AC output will be shut off automatically.
Short Circuit Protection
When short circuits occur, Buzzer sound 11 times and red light turn on, output
will be shut off.
Overload Protection
When overloads occur, Buzzer constantly sound and red light turn on, output
will be shut off.
Reverse polarity protection:Fuse or Mosfet
a. via Fuse: When battery terminals are reverse connected, fuse will be burned
to protect appliances.
b.via MOSfet(Optional): When battery terminals are rever: se connected, the
inverter won’t work unit correct connect.
Over Temperature Protection
When heat sink temperature exceeds 45°C, the inner cooling fan will
automatically turn on to cool the inverter. When inner temperature exceeds
75°C, Buzzer sound 5 times and red light turn on AC output will automatically
shut off.
TROUBLESHOOTING REFERENCE
Acoustics buzzer alarms
When applying the inverter to acoustics devices, some inferior acoustics
devices will buzz, this is because the output wave from the inverter is
modified sine wave inverter.
TV Interference
You can get minimum interference through use of a filter. On some occasions,
when the interference of every weak signals becomes too obvious, you can try
the following:
- Place the inverter far from the TV and TV antenna,
- Try to change the direction of TV signals cable and TV antenna to reduce the interference to minimum.
- Use screen cable antenna of highly quality.
SYMPTOM | POSSIBLE CAUSE | SOLUTIONS |
---|---|---|
ON/OFF switch Is switched on, | There is no voltage at the DC Input Terminals |
1.Check the continuity of the battery Input circuit
2.Check that the battery fuse is Intact. Replace If blown
3.Check That all connections In the battery Input circuit are tight
LED does not light. Buzzer is off. There Is no AC voltage| Polarity of the
Input voltage has been reversed that has blown the DC side fuses.
( Note: Reverse polarity may cause permanent damage)| Correct the polarity of
the input connections and replace the fuse.
If the unit does not work after replacing the fuse, the unit has been
permanenth, damaged Call Technical Support
Baer alarm is sounded 1 time. Thera Is noAC voltage.| I Loose AC output
connections. 2.Short circuit of AC Output wiring.| 1.T1ghten AC output
connections 2.Check AC wiring for short circuit.
Buzzer sound 2dmes| Voltage at the DC input termbleb reeds below
10.5±0.5VDC(12V version).
21.0±1.0VDC(24V version).
42.0e2.0VDC(48V version),| 1.Check that the battery Is kitty charged.
Recharge. if low
2.Check that the battery cables are thick enough to carry the required current
over the
required length. Use
thicker cables. If required
3.Tighten connections of the battery input circuit
Butter sound 3times
and red light turn OD| VOltago at the DC input terminals reads below.
10.010SVDC(12V version), 20.0e1.0VDC(24V version), 40.O±2.OVDC(48V version),|
1.Check that the battery Is fully charged. Recharge. If low
2.Check that the battery cables are thick enough to carry the required current
over the
required length. Use thicker
cables. if required
3.Tighten connections of the battery Input circuit.
Buzzer sound 4 times
and red light turn on| Higher input DC voltage than
16.0+£0.5VDC(12V version),
32.0£1.0VDC(24V version),
64.0+£2.0VDC(48V version),| 1. Check that the voltage at the DC input
terminals is more than 16V/32V/64V DC.
2. Ensure that the maximum charging voltage of the battery charger /
alternator / solar charge controller is below 16 V/32V/64V DC.
3. Ensure that an un-regulated solar panel or wind turbine is not used to
charge a battery
Buzzer sound 5 times and red light turn on| System overheating| 1. Check that
the fan is working. If not, the fan / fan control circuit may be defective
Call Technical Support
2. If the fan is working, check that the ventilation slots on the suction
side and the openings on the discharge side of the fan are not obstructed
3. If the fan is working and the openings are not obstructed, that check cool
enough replacement air is available. Also check that the ambient air
temperature is less than 45° C
4. Reduce the load to reduce the heating effect
5. After the cause of overheating is removed and the unit cools down, it will
reset automatically
Red light constantly on| The loads is 200% higher than rated power.| 1.
Disconnect the load
2. Reduce the load
3.Cool the unit.
Note: * When 190%<Lo0ad<200%,limit current of AC output, that’s to say AC Output Voltage decreasing, output shut down, delay 60s to restart automatically, once ten consecutive restart automatically, then you have to start the inverter by manual.
Specifications
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
- icon 1](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power- Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-icon-1-1.jpg)
Note: *The specifications are subject to change without prior notice for further improvement of products.
Maintenance
To keep your inverter operating properly, there is very little maintenance
required.
You should clean the exterior periodically with a dry cloth to prevent
accumulation of dust and dirt. At the same time, tighten the screws on the DC
input terminals.
Warranty
We guarantee this product against defects in materials and workmanship for a
period of 18 months from the date of retail purchase by end user.
This warranty will be considered void if the unit has been misused, altered,
or accidentally damaged. We are not liable for anything that occurs as a
result of the user’s fault.
If the warranty period for your product has expired, if the unit was damaged
by misuse or incorrect installation, if other conditions of the warranty have
not been met, or if no dated proof of purchase is available, your unit may be
serviced or replaced for a flat fee.
Appendix
Appendix I: Remote Control Switch A.Battery Indication
B.Battery voltage
C.AC output running
D.Power consumption
E.AC output voltage
F.Inverter operation
Connecting the Communications Cable
The communications cable is 3meters, 6-conductor cable (wired like a normal
telephone-type cable). This cable is connected to the RJ11 jack on the rear of
the remote control and to the REMOTE port located on the rear of the inverter.
Notice: Inverter’s ON/OFF Switch and Remote control’s ON/OFF Switch is in
parallel.
To use this remote control, must turn the inverter’s ON/OFF Switch to OFF,and
vice versa.
Appendix II:Recommend
For correct operation,the battery voltage should be between 0.9xVnom and and
must be able 1.29xVnom where Vnom is 12V, 24V or 48V depending on model, to
supply sufficient current to your inverter. The following table displays the
recommended things(Battery Cable, Fuse, Battery Capacity) per inverter type.
Inverter type | Input Voltage | DC Battery Cable | Battery Capacity |
---|---|---|---|
300W | 12v | 4mm² (1Red/1Black) | >50Ah |
24V | 2.5mm² (1Red/1Black) | 225Ah | |
48V | 2.5mm² (1Red/1Black) | >12Ah | |
500W/600W | 12V | 6mm² (1Red/1Black) | >100Ah |
24v | 4mm² (1Red/1Black) | >50Ah | |
48V | 2.5mm² (1Red/1Black) | >25Ah | |
1000W | 12v | 10mm² (1Red/1Black) | >160 Ah |
24V | 6mm² (1Red/1Black) | 280Ah | |
48V | 4mm² (1Red/1Black) | >40Ah | |
1500W | 12V | 16mm² (1Red/1Black) | >150Ah |
24V | 10mm² ( 1Red/ 1Black) | >100Ah | |
48V | 6mm² (1Red/1Black) | >60Ah | |
2000W | 12V | 25mm² (1Red/ 1Black) | >250Ah |
24V | 10mm² ( Red/ 1Black) | >100Ah | |
48V | 6mm² ( IRed/ IBlack) | >100Ah | |
2500W | 12V | 25mm² (1Red/1Black) | >250Ah |
24V | 16mm² ( IRed/ 1Black) | >150Ah | |
48V | 10mm² ( 1Red/ 1Black) | >100Ah | |
3000w | 12V | 35mm² (1Red/ 1Black) | >250Ah |
24V | T6mm² ( 1Red/ Black) | 2150Ah | |
28V | Tomm² ( PRed/ IBlack) | Z100Ah |
![Baintech Power Products RS300P Pure Sine Wave Inverter DC-AC Power Inverter
- icon](https://manuals.plus/wp-content/uploads/2023/09/Baintech-Power- Products-RS300P-Pure-Sine-Wave-Inverter-DC-AC-Power-Inverter-icon.jpg)