GfG Polytector III G999P Multi Gas Detector User Guide
- June 13, 2024
- GfG
Table of Contents
GfG Polytector III G999P Multi Gas Detector
Product Information
The POLYTECTOR III G999 is a gas detector device that utilizes sensor- dependent measurement methods. It is designed to operate within specific environmental conditions, with a permitted humidity range of 5 to 95% relative humidity and a permitted air pressure range of 70 to 130 kPa. The device is powered by a rechargeable NiMH battery module (5.2 V 2100 mAh) and has a maximum operating time of 130 hours, which may vary depending on equipment, use, sensors, and battery age.
The device is constructed with a rubberized plastic housing and has dimensions of 68 x 136 x 39 mm (W x H x D). It weighs a maximum of 395 g and has an IP67 protection class rating, indicating its resistance to dust and water ingress.
Important safety precautions include not charging or opening the device in
potentially explosive areas. The charging contacts should always be kept
clean, and any dirt can be removed with a damp cloth using clear water.
Solvents or cleaning agents should not be
used.
The POLYTECTOR III G999 has different certifications depending on the model:
- Polytector III G999C: I M2 Ex ia db I Mb
- Polytector III G999E/P: I M1 Ex ia I Ma
- Polytector III G999M: I M1 Ex ia da I Ma / II 2G Ex ia db IIC T4 Gb / II 1G Ex ia IIC T4 Ga / II 1G Ex ia da IIC T4 Ga / II 2G Ex ia db IIC T4 Gb
Product Usage Instructions
To switch on the device, press the right button for approximately 1 second. Upon switching on, the device will perform a self-test, including visual and acoustic alarm checks, as well as displays of the sensors and gas types used, including set alarm thresholds.
If the inspection periods for bump tests, adjustments, and annual maintenance
are exceeded, an information and warning message will appear. Acknowledge the
message by pressing the middle button and arrange for the device to be tested
or checked at the next
opportunity.
To switch off the device, press the right button for approximately 5 seconds. Release the button after the countdown ends. The display will show “Switch off”.
The POLYTECTOR III G999 has various alarm types and values:
- Current value (CV) alarms: Triggered when the current gas concentration exceeds or falls below a specified value. The current value alarms can be set individually.
- Short-term exposure value (STEL): Shows the average value of the last 15 minutes.
- Long-term exposure value (TWA): Monitors exposure over 8 hours.
To view individual values in the zoom display, briefly press the right button.
Pressing the right button multiple times will display all sensors and the
battery charge status in succession. Holding the right button in the zoom
display will switch to the detailed
view, showing additional maximum, short-term, and long-term values.
In PEAK mode, maximum values are permanently displayed, and pressing the left
button activates PEAK mode. The PEAK symbol will appear in the display. In the
zoom display, the PEAK value will be shown in the upper left corner instead of
the maximum value
measured since PEAK was activated.
PRODUCT OVERVIEW
Measurement method
Sensor-dependent
Environmental conditions (operation)
- Permitted operating temperature: -20 to +50 °C
- Permitted humidity: 5 to 95 % r. h.
- Permitted air pressure: 70 to 130 kPa
Power supply
NiMH battery module (5.2 V 2100 mAh; rechargeable)
Operating time
Max. 130 hours (Depending on equipment, use, sensors and age of the battery)
Housing
- Material: rubberized plastic
- Dimensions: 68 x 136 x 39 mm (W x H x D)
- Weight: max. 395 g
- Protection class: IP67
The device must not be charged or opened potentially explosive areas!
Charging contacts must always be kept clean!
Dirt can be removed with a damp cloth (clear water).
Do not use solvents or cleaning agents!
ATEX certification
GfG – Gesellschaft für Gerätebau mbH
Klönnestraße 99 · 44143 Dortmund · Germany
- Phone: +49 231 56400-0
- Fax: +49 231 56400-895
- E-mail: info@gfg-mbh.com
- Internet: www.gfgsafety.com