FEATURES
Ceiling hanging bracket:
This bracket can be used to hang the camera from a suspended ceiling or other
location that is not strong enough to hold a screw.
PRECAUTIONS
- Fasten the bracket to a ceiling strong enough to support the camera weight (approx. 2.9 kg {6.38 lbs}).
- Wipe the bracket regularly using a soft and dry cloth, or a cloth moistened with a water solution of an ordinary kitchen detergent.
- Do not use chemicals for cleaning the enclosure as it may damage the surface.
- All the necessary steps required for installing this product must be taken by a qualified service person or system installer.
- Be sure to use the aniti-fall wire.
- Do not use this bracket except with suitable cameras.
- Follow all applicable local and national electrical, fire and safety codes when installing the camera with this ceiling mount bracket.
The model numbers in this Operating Instructions are shown without suffix.
INSTALLATION
-
Decide where to install the camera and open a φ60 mm {2-3/8”} hole in the ceiling.
-
Setting up the Mounting board.
For suspended ceilings -
Prepare a Mounting board long enough to span the distance between the C-beams, and cut a φ60 mm {2-3/8”} hole in it that matches the hole in the ceiling.
-
Use the template (provided) to cut four φ6 mm {1/4”} holes (in four positions) in the mounting board.
For structurally strong ceilings
Prepare the mounting board by cutting a φ60 mm {2-3/8”} hole in it.
-
Attach the Ceiling Mount Ring (provided) to the Mounting board Screws are not provided.
Align it with the position the camera will be installed.
-
Installing the Mounting board.
For suspended ceilings
Align it with the hole in the ceiling and lay it across the two C-beams.
For structurally strong ceilings
Align it with the hole in the ceiling and attach it. -
Remove the Mounting Screw (M3, provided), pull up the Camera Mounting Base off the camera, and turn the camera counterclockwise.
-
Remove the two Lock Lug Fixing Screws and replace the Lock Lug with L-type.
Retighten the two Lock Lug Fixing Screws (refer to the right figure).
Recommended tightening torque: 0.68 N·m {0.51 lbf·ft}
-
Remove the two Lock Lug Fixing Screws and replace the Lock Lug with L-type.
Retighten the two Lock Lug Fixing Screws (refer to the right figure).
Recommended tightening torque: 0.68 N·m {0.51 lbf·ft}
-
Pass the power cord and video cables of the Camera Mounting Base through the hole in this bracket, and fasten it to the bracket with the four M4-L8 Screws (provided).
Recommended tightening torque: 1.56 N·m {1.16 lbf·ft}
-
Fit the Slot Masking Cover (provided) over the bracket, insert the Hexagon Socket Head Screws (M3, provided) into their holes, and fasten the Ceiling Mount Ring (provided) with the two nuts (M3, provided).
Recommended tightening torque (M3): 0.68 N·m {0.51 lbf·ft}
Recommended tightening torque (M4): 1.56 N·m {1.16 lbf·ft}
-
Suspend the Fall Prevention Wire for the camera from the Camera Mounting Base.
Note : Make sure that the wire matches the Fall Prevention Wire Fixing Angle.
-
Attach the camera to the Camera Mounting Base, turn the camera clockwise, and tighten the Mounting Screw (M3, provided).
Recommended tightening torque: 0.68 N·m {0.51 lbf·ft}
-
Place the Decoration Cover for the bracket on the camera. Then, pull up the Slot Masking Cover (provided).
-
Attach the Fall Prevention Clip (provided) to the anchor bolt.
Attach the Fall Prevention (provided) to the bracket and the Fall Prevention Angle Clip.
Note : Two spacer nuts are necessary for the anchor bolt.
-
Cover the bracket with the Heat Insulator (provided).
SPECIFICATIONS
Ambient Operating Temperature: 10˚C – +50˚C {14˚F – 122˚F}
Dimensions: 120 (diameter) × 202 (D) mm {4-3/4” (diameter) × 7-61/64” (D) mm}
Weight: 720 g {1.59 lbs}
Weight and dimensions indicated are approximate.
Specifications are subject to change without notice.
STANDARD ACCESSORIES
Fall Protection Wire……………………………………1 pc.
Fall Prevention Clip……………………………………1 pc.
Ceiling Mounting Ring ……………………………….1 pc.
L-type Base Lug ……………………………………….1 pc.
L-type Lock Lug………………………………………..1 pc.
Slot Masking Cover……………………………………1 pc.
Hexagon Socket Head Screw (M4) ……………2 pcs.
Wrench for Hexagon Socket Head Screw…….1 pc.
Nut (M4)…………………………………………………4 pcs.
Screw (M3)……………………………………………..2 pcs.
Screw (M4-L8) ………………………………………..4 pcs.
Template………………………………………………….1 pc.