Brecknell DS1000-LCD Floor Scale User Manual
- June 13, 2024
- Brecknell
Table of Contents
DS1000-LCD Floor Scale
User Manual
DS1000-LCD Floor Scale
Model DS 1000-LCD
Operator Manual
AWT35-100107 Rev AB
Avery Weigh-Tronox is a trademark of the Illinois Tool Works group of
companies whose ultimate parent company is Illinois Tool Works Inc (“Illinois
Tool Works”). Copyright © 2021 Illinois Tool Works. All rights reserved.
No part of this publication may be reproduced, stored in an electronic
retrieval system, or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise without the prior written
consent of the copyright owner, or as permitted by law or under license. Full
acknowledgment of the source must be given.
Avery Weigh-Tronox is a registered trade mark of the Avery Weigh-Tronox group
of companies. This publication was correct at the time of going to print
however, Avery Weigh-Tronox reserves the right to alter without notice the
specification, design, price or conditions of supply of any product or service
at any time.
All third party brands and product names used within this document are
trademarks or registered trademarks of their respective holders.
Manual revision history
Current Issue | Date Created | Details of Changes |
---|---|---|
Rev AA | Nov 2021 | New |
Rev AB | March 2022 | Hold modes |
Warnings
United States
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Canada
This digital apparatus does not exceed the Class A limits for radio noise
emissions from digital apparatus set out in the Radio Interference Regulations
of the Canadian Department of Communications.
1.1 Safe installation
THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS.
Installation and maintenance of the equipment must only be carried out by
trained and authorized personnel.
Electrical installation
The mains lead must be connected to a supply outlet with a protective earth
contact. The electrical supply at the socket outlet must provide over current
protection of an appropriate rating.
For your protection all mains (110V or 230V) equipment used out of doors or in
wet or damp conditions should be supplied from a correctly fused source and
protected by an approved ground fault protection device (RCD, GFCI etc.)
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.
Routine maintenance
To avoid the possibility of electric shock or damage to the machine, always
switch off the machine and isolate from the power supply before carrying out
any routine maintenance.
To avoid the risk of the machine falling, where applicable, ensure that it is
placed securely on a flat and level surface.
1.1 Safe use
Caution – Cleaning the indicator/weigh head
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions,
such as washing soda, should not be used especially on the display windows.
Under no circumstances should you attempt to wipe the inside of the machine.
The outside of standard products may be wiped down with a clean cloth,
moistened with water containing a small amount of washing up liquid.
Training
Do not attempt to carry out any procedure on a machine unless you have
received the appropriate training or read the Instruction Manual.
EMC compliance
The following may be applicable to your machine.
WARNING: This is a class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to
take adequate measures.
Introduction
The DS 1000-LCD is a portable, electronic drum weighed scale. The platform has adjustable locking feet and a deck with built-in, front and rear ramp angles to easily roll the drums on and off the scale. The scale provides accurate weight with an easy-to-read LCD display, which can be mounted on desk/pole stand/guide rail and powered using the included AC/DC power adaptor.
2.1 Unpacking
Carefully take the scale out of its package, make it sure it’s not damaged and
all accessories are included:
- SBI 210-LCD Indicator with 10 in (25 cm) interface cable, pole and bench brackets
- 9 Vdc 600 mA Power supply with plug adaptor
- DS1000 Platform with 10 ft (3 m) interface cable
- Installation Manual and Safety Sheet
2.2 General Installation Guidelines
To get the best performance from the scale, link the platform and indicator
connectors and, place the DS 1000-LCD scale in a location that will not
degrade its accuracy.
- Try to avoid placing the scale in direct sunlight or near air vents
- Place the scale on a level flat surface. It is not advised to place the scale near vibrating machinery
- Avoid unstable power sources. Do not use near large users of electricity.
2.2.1 Positioning the Scale
Two wheels built into the side channels allow the base to be easily tilted and
moved.
2.2.2 Levelling the Scale
Level the scale using the four adjustable feet on the bottom of the platform.
Always check the level prior to using scale.
2.3 Powering ON/OFF the Scale
With the charger plugged into the indicator, press the ZERO/ON/OFF key to
turn the scale on.
Press and hold the ZERO/ON/OFF key for 5s to turn the scale off.
Optional: remove the battery compartment lid on the rear to insert 6x AA batteries (not included).
2.4 Error Codes
0 ———- | Initial zero weight over max load (default, 100% F.S.) |
---|---|
———– | Overload, >1004.5 lb or >501.8 kg (default, 100% F.S. + 9 divisions) |
EEP.E# | Settings error # |
2.5 Front Panel and Keys
**** Never press a key with anything but your finger. Damage to the overlay may result if sharp or rough objects are used.
2.5.1 Display Annunciators
| Display reading is stable
---|---
| Scale at Zero. Gross weight is 0, Tare is 0
NET
| Indicates a Net weight. Tare is not 0.
| Indicates an ACCUMULATION transaction
lb kg
| Current unit of measure ( % and Pcs in PERCENTAGE and COUNTING modes)
HI OK LO
| Scale is working in COMPARISON mode
| Battery status (or AC/DC operated)
HOLD
| Scale is working in HOLD mode
2.5.2 Operation Keys
The key functions are listed below. In menu mode, the keys have secondary
functions.
| – Enters/exits the HOLD function.
– In Menu mode goes to previous menu screen; exit menu.
---|---
| Sends information to a device; selects WEIGH / COUNTING / PERCENT modes.
– In Menu mode goes to previous menu screen; increase / change a data value.
| – Enables the ACCUMULATION mode; displays instances and totals.
– In Menu mode goes to next menu option; decrease / change a data value.
| – Selects the unit of measure; opens the COMPARISON limit settings.
– In Menu mode selects / goes to next data value position.
| – Tares the scale.
– In Menu mode opens menu option; confirms a value / function / operation.
| – Zeroes the scale; turns the scale on / off.
– In Menu mode: cancel an operation and exit from the current working mode.
Scale Operation
This section covers the scale operations of simple weighing and basic DS
1000-LCD scale functions.
**** A warm-up time of 15 minutes is required to stabilize the measured
values.
3.1 Simple Weighing
- Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary
- Place the item to be weighed on the scale platform The weight is displayed in the weight window.
3.2 Tare Weighing
To carry out a Net weighing, follow the steps below:
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Place the item to be tared (e.g., hand truck) on the scale platform Weight of the item is displayed in the weight window.
-
Press the TARE key
The weight is tared, 0 weight is displayed and the Net annunciator lights. -
Place the item to be weighed on the scale platform
The Net weight is displayed in the weight window.
To remove a tare, remove the item(s) from the scale platform and Press the TARE key…0 weight is displayed, and the Net annunciator light turns off. The unit is now in gross weighing mode.
3.3 Changing Units
This scale can be used in either kg or lb units of measure. To change the unit
of measure, press the UNIT key.
3.4 Changing Weighing Mode
This scale can be used in weigh / count / percent mode. Press and hold the
FUNC key to open the modes screen and the keys to change weighing
mode.
3.5 Print Function (Com Ports)
The DS 1000-LCD comes as standard with one full duplex RS-232 serial port and
A type USB port, designed for connection to either a PC or a serial printer
using the appropriate adaptor and cable.
** Open the Submenu 1 RS232 / USB in the User Menu to select and configure the Com Port, print mode, and format. Default print out format** MULTIPLE.
- Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
- Place the item to be weighed on the scale platform.
- Press the PRINT key to send the data out to an external device.
Weighing Modes
This section covers the scale operations and functions of the DS 1000-LCD
scale.
4.1 Hold Function
This function can be used to freeze a displayed weight/pcs value. In Hold
mode, the scale can capture and hold stable weight/pcs values, or average an
unstable value. Then, the indicator temporarily freezes (Hold) the value on
screen for the user to view or record.
The DS 1000-LCD is featured with three hold modes: Manual, Average and
Automatic (default).
** The indicator provides special mode settings to accommodate weight
movements in the User Menu. Open the Submenu 1 HOLD** to enable this mode
and change the parameter values: NLD.RNG (10 div), HLD.RNG (5 div), AVG.TIM (5
sec), STB.TIM (15 sec) accordingly.
4.1.1 Automatic Hold Mode (Default)
When this mode is activated, the scale automatically grabs and holds the
weight on the display until the weight returns to zero and a new Hold weighing
session starts.
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press the HOLD key to enable this function
The Hold annunciator flashes. -
Place the item to be weighed/counted on the scale platform
If the weight sensed is above the NLD.RNG zero range (10 div = 5 lb, 2 kg) and doesn’t exceed the HLD.RNG oscillations range (5 div = 2.5 lb, 1 kg) within the AVG.TIM average time (5 sec), the indicator calculates and displays the Hold mode weight.
The Hold annunciator stops flashing. -
Remove the item(s) from the scale platform and repeat the steps above for other Hold weighments.
-
Press the HOLD key to exit the current mode.
** If the weight oscillations exceed the HLD.RNG division range value (5 div) within the STB.TIM time value (15 sec), the indicator will display STB.ER. See H old Menu.**
4.1.2 Average Hold Mode
When this mode is activated, the scale calculates accurate weight of unstable
loads e.g., live animal and holds that weight on the display until the weight
returns to zero and tare or hold button is pressed.
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press the HOLD key to enable this function
The Hold annunciator flashes. -
Place the item to be weighed on the scale platform
If the weight sensed is above the NLD.RNG zero range (10 div = 5 lb, 2 kg) and doesn’t exceed the HLD.RNG oscillations range (5 div = 2.5 lb, 1 kg) within the AVG.TIM average time (5 sec), the indicator calculates and displays the Hold mode weight.
The Hold annunciator stops flashing. -
Press the TARE key to repeat the Hold weighment or the HOLD key to exit the current mode.
The scale will automatically exit the Hold mode after the HLD.TIM time value (default, disabled).
** If the weight oscillations exceed the HLD.RNG division range value (5 div) within the STB.TIM time value (15 sec), the indicator will display STB.ER. See Hold Menu.**
4.1.3 Manual (Toggle) Hold Mode
When this mode is activated, the scale grabs the first stable weight reading
and holds that weight on the display until the weight returns to zero and the
tare or hold button is pressed.
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press the HOLD key to enable this function0
The Hold annunciator flashes. -
Place the item to be weighed on the scale platform
If the weight sensed is stable for STB.TIM (15 s) and above the NLD.RNG zero range (10 div = 5 lb, 2 kg), the indicator displays the Hold mode weight. The Hold annunciator stops flashing. -
Press the TARE key to repeat the Hold weighment or the HOLD key to exit the current mode.
** If the weight is not stable within the STB.TIM time value (15 sec), the indicator displays STB.ER. See Hold Menu.**
4.2 Accumulation Function
This function can be used to record totals of individual weighments and
transactions number.
The DS1000-LCD is featured with two accumulation modes: Manual and Automatic
(default).
The ACC mode can be disabled and the mode changed in the Config Menu.
** The Automatic A.c mode is activated when the load is stable and above
the NLD.RNG (10 div = 5 lb, 2kg) zero range. These settings can be changed in
the Submenu 1 HOLD.**
- Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
- Place the item(s) to be weighed / counted on the scale platform.
- Press the ACC key to add up the weight/pcs to total weight/pcs and number of transactions.
- Remove the item(s) from the scale platform and repeat the steps above for other Acc weighments.
In accumulation mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.2.1 View Totals
- Press and hold the TOTAL key to view the current total weight/pcs and number of transactions.
- Press the TOTAL key to exit the accumulation screen.
4.2.2 Clear Totals
- Press and hold the TOTAL key to view the current total weight/pcs and number of transactions.
2. Press the ZERO/ON/OFF key to clear the accumulation memory and return to main screen.
3. Press the TOTAL key to exit the accumulation screen.
4.3 Comparison Function
The DS1000 Comparison mode can be used to quickly check the acceptability or
unacceptability of an item’s weight / count i.e., check-weighing / check-
counting. This function is available in weighing, percent and counting modes.
Open the User Submenu 1 BEEP to enable the audible alarm. The COMPAR function
can be disabled in the Config Menu.
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press and hold the FUNC key for three seconds. Toggle the weighing modes by pressing the ↑ ↓ keys and select either the WEIGH, PERCNT or COUNT mode.
-
Place the item(s) to be weighed/counted on the scale platform
If the weight/pieces is beyond the upper limit, the HI annunciator lights
If the weight/pieces is within the limits, the OK annunciator lights
If the weight/pieces is below the lower limit, the LO annunciator lights -
Remove the item(s) from the platform and repeat the steps above for other Compare weighments.
In comparison mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.3.1 Setting HI / OK /LO Limits
- In weighing or counting mode, press and hold the DATA key. Release the key when the “COMP” message pops up. Press the TARE key to confirm.
- The HI annunciator lights. Adjust the upper limit pressing the ↑ ↓ → keys. Press the TARE key.
- The LO annunciator lights. Adjust the lower limit pressing the ↑ ↓ → keys. Press the TARE key to confirm.
- The indicator stores the limits and returns to weighing / counting mode screen.
4.4 Counting Mode [Pcs]
The DS1000 Counting mode has been designed to allow the operator to easily
carry out basic sampling and counting routines on this scale. The COUNT mode
can be disabled in the Config Menu.
-
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press and hold the FUNC key for three seconds. Press the ↑ ↓ keys to navigate the options.
-
Select the COUNT option and press the TARE key to confirm.
The Pcs annunciator flashes and the last stored piece weight is recalled. -
Place the item(s) to be counted on the scale platform.
-
The number of parts is displayed in the Pcs window.
-
Remove the item(s) from the platform and repeat the steps above for other Count weighments. In counting mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.4.1 Sampling – Piece Weight
-
In counting mode, press the DATA key. Release the key when the “SPL.—” message pops up.
-
Place a known quantity of items to be counted on the scale platform. Press the TARE key to confirm.
The “INP.PCS” message pops up. -
Use the ↑ ↓ keys to adjust the number of items to be sampled.
-
Press the TARE key to confirm.
-
The indicator calculates the piece weight and returns to counting mode screen.
** If the piece weight obtained is less than 0.5 div, the indicator displays PWT.ER.
4.5 Percent Weighing Mode
As the counting mode, the DS1000 Percent weighing mode has been designed to allow the operator to easily carry out weighments on % basis. The PERCNT** mode can be disabled and the % format changed in the Config Menu. -
Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if necessary.
-
Press and hold the FUNC key for three seconds. Press the ↑ ↓ keys to navigate menu options.
-
Select the PERCNT option and press the TARE key to confirm.
The % annunciator flashes and the last stored % item weight is recalled. -
Place the item(s) to be weighed on the scale platform.
-
The weight as percentage value of the % item weight is displayed.
-
Remove the item(s) from the platform and repeat the steps above for other % weighments.
In % weighing mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.5.1 Calculating % Item Weight
-
In percent mode, press the DATA key. Release the key when the “SPL.—” message pops up.
-
Place a known weight item(s) to be weighed as % weight on the scale platform. Press the TARE key to confirm.
The “INP.PCS” message pops up. -
Use the ↑ ↓ keys to adjust the % value.
-
Press the TARE key to confirm.
-
The indicator calculates the 100% item weight and returns to percent mode screen.
**** If the piece weight obtained is less than 0.5 div, the indicator displays PWT.ER.
Menus
There are four menus that allow you to configure, enable, or execute specific functions or options.
- User and Diagnostics Menu, page 16
- Calibration Menu, page 17
- Service Configuration Menu, page 18.
5.1 User Menu
In the User Menu there are various submenus available to configure specific
sections of the scale
operating modes, including the print and communication settings.
In general weighing mode, press the HOLD and ZERO/ON/OFF keys. Release
the keys when the “USER” message pops up to open the User Menu.
Navigate the menu using the keys, press the TARE key to confirm or the
ZERO/ON/OFF key to cancel the operation / exit the menu.
5.1.1 User Options
USER
SubMenu1| SubMenu2| Option| Default| Description
RESET| NO| NO| NO| Returns the USER parameter to the
factory setting
YES
RS232
Port (com1)
| BAUD.RT| 600|
9600
| Sets the baud rate of com1
1200
2400
4800
9600
19200
BYT.FMT
| 8N1|
8N1
|
Sets the data bits format of com1
7O1
7E1
7O2
7E2
OUT.MOD| NONE| PRTCMD| Sets the output mode of com1: NONE = no
communication; CONT = continuous output;
PRINT = press PRINT key for output; CMD = via print format command only;
PRT.CMD = output with PRINT key and print format command (See FMT);
STABLE = output when the weight stable condition is met (See Motion settings)
Note: when set to PRINT or CMD mode, the weighing must be in stable condition.
CONT
PRINT
CMD
PRTCMD
STABLE
| FMT
Print Out Format
| MULTPL| MULTPL| Com1 output content and format:
MULTPL = default format. See Appendix ;
SINGLE= only displayed content and current status will be output, it’s compatible with NCI-SCP01;
EH-SCP = command / response mode;
SCP-12 = only displayed content and status will be output, it’s compatible with NCI-SCP12(NCI3835);
Eh-sp2 = See Appendix ;
Lfuulf /——- = special characters. Do not
use.
---|---|---|---|---
SINGLE
EH-SCP
SCP-12
Eh-sp2
Lfuulf
Lfuu–
Lf–lf
Lf
–uulf
–uu–
__ lf
USB
Port (com2)
| BAUD.RT| 600| 9600| Sets the baud rate of com2
1200
2400
4800
9600
19200
BYT.FMT| 8N1| 8N1| Sets the bits format of com2
7O1
7E1
7O2
7E2
OUT.MOD| NONE| PRT.CMD| Sets the output mode of com2: NONE = no
communication; CONT = continuous output;
PRINT = press PRINT key for output; CMD = via print format command only;
PRT.CMD = output with PRINT key and print format command ( See FMT ) ;
STABLE = output when the weight stable condition is met (See Motion settings)
Note: when set to PRINT or CMD mode, the weighing must be in stable condition.
CONT
PRINT
CMD
PRT.CMD
STABLE
| FMT
See Appendix
| MULTPL| MULTPL| Com2 output content and format:
MULTPL = default format. See Appendix ;
SINGLE= only displayed content and current status will be output, it’s compatible with NCI-SCP01;
EH-SCP = command / response mode;
SCP-12 = only displayed content and status will be output, it’s compatible with NCI-SCP12(NCI3835);
Eh-sp2 = See Appendix ;
Lfuulf /——- = special characters. Do not use.
---|---|---|---|---
SINGLE
EH-SCP
SCP-12
Eh-sp2
Lfuulf
Lfuu–
Lf–lf
Lf—-
–uulf
–uu–
____ lf
BEEP| KEY| YES / NO| YES| Yes = enables the beep when
a key is pressed
COMPAR
mode
| NONE| NONE| COMPARE function modes:
NONE = disabled .
L.LOW
IN.LMT
O.HIGH
OUT.LMT
HOLD
Function
| HLD.MOD| NONE| AUTO| Enables the HOLD function mode: NONE =
disabled.
TOGGLE (Manual) = if selected, press the HOLD key to enter HOLD mode. If the
weight is over (NLD.RNG) and stable (STB.TIM), the data is hold on the
display. Press the HOLD key to exit the Hold mode.
AVERAG = if selected, the weight over (NLD.RNG), which variation is less than
(HLD.RNG), it’s averaged in (AVG.TIM) and hold on the display. To exit this
mode: press the HOLD key or wait (HLD.TIM) elapses.
TOGGLE
AVERAG
| | AUTO| | AUTO = if selected, acts as the AVERAG mode and after
each NLD.RNG zero, any loads over (NLD.RNG), is hold on the display.
---|---|---|---|---
AVG.TIM
Average| 1 ~ 60| 5| Averages weights in Hold mode for: 1~60
seconds.
STB.TIM
Stable| 3*AVG.TI M ~ 255| 15*| Allows 3(AVG.TIM) ~ 255
seconds for stable conditions to be met in Hold mode.
HLD.TIM
Hold| 0 ~ 65535| 0| Displays Hold mode weight for:
0 = until HOLD key pressed;
1~65535 = the scale exits the Hold mode after 1 ~ 65535 seconds.
HLD.RNG
Oscillations| 0 ~ 255| 5| Sets the weight oscillation range
that can be averaged in Hold mode:
0 = any weight range can be averaged;
1 ~ 255 = only the weight which oscillates within the 1 ~ 255 div
range can be averaged.
NLD.RNG**
No Load Detected Range
| | 1 ~ 255| 10| Sets the weight range that the indicator
considers as the Zero range for the relevant function e.g. Auto Hold Mode.
1 ~ 255 = the range of weight is 1 ~ 255 div.
Note: It must be above the Config-Motion.
A.OFF.T| | 0 ~ 255| 3| Sets the auto off time:
0 = disabled;
1 ~ 255 = if in standby mode for 1~ 255 minutes, turn the scale off.
LCD.BLT| | AUTO| AUTO| Sets the LCD backlight:
Auto: if in standby mode for 10 seconds, turn the display backlight off.
OFF:always off; Onaway’s on.
OFF
ON
LCD.CST| | CST1-5| CST5| Adjusts the LCD contrast
5.2 Diagnostics
In the menus below there are various submenus available to check the scale LCD
display and COMM Ports statuses and SBI 210-LCD indicator information.
5.2.1 Test Menu
In general weighing mode, press the PRINT and ZERO/ON/OFF keys.
Release the keys when the “TEST” message pops up to open the Calibration
Menu. The number of calibrations is shown.
Navigate the menu using the keys, press the TARE key to confirm or the
ZERO/ON/OFF key to cancel the operation / exit the menu.
TEST
SubMenu1| | | | Description| | |
DSP.TST| LCD testing : the indicator lights all the annunciators,
including the 8 digits.
232.RD| RS232 receive data testing : the indicator displays 2.RD.–
It receives and displays any HEX codes less than 7F. E.g. ,If the code
received is 0x31, the indicator displays 2.RD.31
232.TD| RS232 send data testing: the indicator displays 2.TD.55 and the
serial port continuously transmits 0x55. Use the and keys to change the
character.
USB.RD| USB receive data testing: same as RS232 receiving data testing.
USB.TD| USB send data testing: same as RS232 send data testing.
KEY.TST
| Operation keys testing: the indicator displays KEY.–
The following code will be displayed when any of the below key is pressed
| HOLD| 01| | PRINT| 02|
ACC| 04| UNIT| 08
TARE| 10| ZERO| 20
5.2.2 Misc Menu
In general weighing mode, press the ACC/TOTAL and ZERO/ON/OFF keys.
Release the keys when the “MISC” message pops up to open the Misc. Menu.
Navigate the menu using the keys, press the TARE key to confirm or the
ZERO/ON/OFF key to cancel the operation / exit the menu.
MISC
SubMenu1| Description
CODE| Do not use.
VOL| Checking the voltage: the indicator board voltage is shown U X.X (V )
VER| Checking the version: the indicator software version is shown
5.3 Calibration Menu
The scale is configured from the factory to match the specified settings for
each unit, as defined by the product specifications and sales brochure.
Modification of the settings can be accomplished by altering the calibration
settings below.
Calibration and/or configuration of calibration settings of your scale should
be accomplished by a trained service technician using certified weights to
ensure proper operation and accuracy. Calibration is not covered under
warranty.
5.3.1 Calibration Options
In general weighing mode, press the TARE and ZERO/ON/OFF keys. Release
the keys when the “CAL” message pops up to open the Calibration Menu. The
number of calibrations is shown.
Navigate the menu using the keys, press the TARE key to confirm or the
ZERO/ON/OFF key to cancel the operation / exit the menu.
CAL
SubMenu1| SubMenu2| Option| Description
ZERO| | | Adjusts the CAL.P0 point only.
LINE| CAL.P0| | Stores the Zero calibration point (mandatory).
CAL.P1| | Adds the cal. point 1 (mandatory). Use a standard weight over
10% F.S.
END.Y| YES / NO| Saves and exits the calibration points:
Yes = go to CAL.END;
No = add another calibration point
CAL.P2| | Adds the cal. point 2 (optional). Use a standard weight over
10% F.S. and load used in CAL.P1.
END.Y| YES / NO| Saves and exits the calibration points:
Yes = go to CAL.END;
No = add another calibration point
CAL.P3
| | Linear calibration point3: do third weight point calibration, standard weight must be over 10%FS and be larger than it in CAL.P2 , this point can be omitted.
GEO
| |
16
| Do not use.
See SBI 210-LCD Operation Manual. See Confi-Geo.Cal
INPUT| | | Do not use.
| | | See SBI 210-LCD Operation Manual.
---|---|---|---
CAL.END| | | Saves and exits the calibration points. The indicator
reboots in weighing mode.
5.3.2 Calibration Procedure
The procedure covers the Line Calibration. You can add up to 1+3 calibration
points.
Calibration and/or configuration of calibration settings of your scale should
be accomplished by a trained service technician using certified weights to
ensure proper operation and accuracy.
Calibration is not covered under warranty.
-
Turn the scale on and zero the display, if necessary, by pressing the ZERO/ON/OFF key.
-
Press the TARE and ZERO/ON/OFF keys. Release the keys when the “CAL” message pops up to open the Calibration Menu. The number of calibrations is shown.
-
Press the ACC/TOTAL key to select the “LINE” menu option.
-
Make sure that there is no weight on the platform scale.
-
Press the TARE key to open the Line Calibration mode.
CAL.P0, and 0 will be displayed. Press the UNIT key for more than 2.5s to change the calibration unit. -
Press the TARE key to store the Zero Calibration Point. CAL.P1, and the scale capacity will be displayed.
-
Use the ↑ ↓ → keys to change the CAL.P1 weight value (>10% of the scale capacity)
-
Place the certified weight over the scale platform.
-
Press the TARE key to store the CAL.P1 Point.
-
Press the TARE key to save the calibration points and exit the Calibration mode or, press the PRINT key to add CAL.P2/3 points.
On calibration complete, the indicator will reboot and return to general weighing mode.
If there’s an error occurred in calibration, the message “CAL.Er” is displayed. Repeat steps 5 to 9 to adjust the calibration points.
5.4 Service Configuration Menus
The scale is configured from the factory to match the specified settings for
each unit, as defined by the product specifications and sales brochure.
Modification of the SBI 210-LCD Indicator settings can be accomplished by
altering the configuration settings in the Config Menu.
**** The configuration and test of your scale should be accomplished by a
trained service technician.
5.4.1 Configuration Options
Press and hold the HOLD key then turn the indicator on by pressing the
ZERO/ON/OFF keys.
Release the ZERO/ON/OFF key when the display lights.
Release the HOLD key when the message “CONFIG” pops up to open the
Configuration Menu.
The number of time that the indicator has been configured is displayed.
Navigate the menu using the keys, press the TARE key to confirm or the
ZERO/ON/OFF key to cancel the operation / exit the menu.
CONFIG
SubMenu1| SubMenu2| Option| Default| Description
RESET| | YES / NO| NO| Resets the configuration to factory
setting.
REGULA| | NONE| NONE| Do not use.
See SBI 210-LCD Operation Manual.
USA
CANAD
EUROPE
PRIM.N| | 100 ~ 100000| 2000 (USA)
2500 (UK/EU)| Sets the number of divisions (div) of the primary unit of
measure (lb).
PRIM.D| | 0.0001 ~
50
| 0.5 (USA)
0.2 (UK/EU)| Sets the weight division (1 div = 0.5 lb) value of the first
unit of measure.
The division value of the secondary unit of measure (1 div = 0.2 kg) is
automatically determined by the indicator according to the first unit.
PRIM. UT| | kg / lb| lb (USA)
kg (UK/EU)| Selects the primary unit of measure: kg or lb.
The default calibration unit is the primary unit.
SECND.N| | 100 ~ 125000| 2500 (USA)
2000 (UK/EU)
| Sets the number of divisions (div) of the secondary unit of measure (kg).
Max 1.25(PRIM.N)
MOTION| | 1 ~ 255| 4| Sets the in-motion weight divisions
range:
1 ~ 255 = ±0.25div (1~255)
OVER.LD| | 0 ~ 100| 0| Sets the overload weight limit:
0 = FS + 9 div
1~100 = 101%FS ~ 200%FS
UNITS| kg| YES / NO| YES| Sets the active unit of
measure:
Yes = enable the unit;
lb| YES / NO| YES
| oz| YES / NO| NO| No = the unit is not active.
---|---|---|---|---
lb oz| YES / NO| NO
ZRO.PNT| IZSM| 0 ~ 100| 100| Sets the initial zero
(power on zero) weight range: 0 = no limit;
1 ~ 100 = (calibration zero point) ±1%FS ~ (calibration zero point)
±100%FS
IN.IZSM| WEIGHT| WEIGHT| Sets the weight type as current
initial zero point when current weight is inside the IZSM range:
WEIGHT = current weight;
CAL.ZRO = calibration zero; LAST.Z.T = last zero/tare value.
CAL.ZRO
LAST.Z.T
OV.IZSM| DSP.OVR| DSP.OVR| Sets the weight type as current
initial zero point when current weight is outside the IZSM range:
DSP.OVR = if the initial zero is over range, display the 0—- error;
WEIGHT = current weight; CAL.ZRO = calibration zero; LAST.Z.T = last zero/tare
value.
WEIGHT
CAL.ZRO
LAST.Z.T
SAZSM| 0 ~ 100| 20| Sets the ZERO key range: 0 = no limit;
1~100 = (initial zero point) ±1%FS ~ (initial zero point) ±100%FS
ZRO.PNT| AZSM| 0 ~ 100| 56| Sets the Automatic Zero
Tracking weight range:
0 = 0 div. Disabled;
1 ~ 100 = ±(0.2+0.05*(1~100)) div/sec
FILTER| | L1/ L2/ L3| L3| Filtering settings
FUNC| HOLD| YES / NO| YES| Yes = enables the Hold
function;
COUNT| YES / NO| YES| Yes = enables the Count mode;
PERCNT| YES / NO| YES| Yes = select the displayed % value
format 100% , 100.0% or 100.00%
| BMI| YES / NO| NO| No = disabled.
See MS 1000-LCD Operation Manual.
---|---|---|---|---
COMPAR| YES / NO| YES| Yes = enables the Compare mode;
ACCUMU| YES / NO| YES| Yes = select the Accumulation mode:
MANUAL: add up the current value to memory when the TOTAL key is pressed.
AUTO: add up the current value to memory when the scale is stable and weight
is over (NLD.RNG)
GEO.CAL| YES| YES| Yes = enables the Geographical Adjustment Factor in the Calibration Menu.
Specifications
Part Number | Capacity & Resolution |
---|---|
8.10036E+11 | DS1000 LCD 500kg x 0.2kg / 1000lb x 0.5lb |
DS1000 Platform:
Size: flat area: 31.5” x 25.2” (800mm x 640mm), including ramps 31.34” x
38.26” (1050mm x 972mm).
Material: mild steel with powder coat paint finish.
Construction: heavy duty welded channel support; 4-planner beam load cells
with adjustable locking feet; ABS junction box – IP65 with 10 ft (3 m)
interface cable.
SBI 210-LCD Indicator:
Display: 6 digits 38mm / 1.5” high, seven segments LCD display.
Power: 9V 600MA adaptor body with USA plugs (included) and 6xAA batteries (not
included).
Operating temperature range: 32~104°F (0~40°C) max relative humidity 80% at
86°F (30°C).
Communication interface: Full-duplex RS-232 & USB type A ports (Coms cable not
supplied).
Operation keys: HOLD, PRINT/FUNC, ACC/TOTAL, UNIT/DATA, TARE, ZERO/ON/OFF
Weighing Accuracy: +/- 3d
Tare Range: 100% subtractive
Zero Range: +/-2% FS
Cable Connection
Pin1: Excitation +
Pin2: Sense +
Pin3: Signal +
Pin4: Excitation –
Pin5: Sense –
Pin6: Signal –
Pin7: Shield
The 7-pin connector from indicator cable (10 in)| The 7-pin connector from
Load cell cable (10 ft)
---|---
|
Appendix – Print Out Formats (FMT)
MULTIPLE
All Modes:
GROSS: 123 lb 4.56 oz
TARE: 11 lb 2.22 oz
NET: 112 lb 2.34 oz
TOTAL: 789 lb 15.2 oz
AWT35-100107 Rev AB
PERCENTAGE: 0%
SAMPLE WT: 0 lb
SAMPLE PT: 0%
ACC.N: 0
TOTAL: 0%
BMI Mode:
SCALE ID: 123456
GROSS: 110.0 kg
TARE: 10.0 kg
NET: 100.0 kg
HEIGHT: 170 cm
BMI: 34.6
SINGLE
Bit | Byte 1 (H1) | Byte 2 (H2) | Byte 3 (H3) | Byte 4 (H4) |
---|
0
| 0=stable| 0= not under capacity| 00=compare disable 01=lower limit 10=ok
11=upper limit
| 00=general weighing 01=count weighing 10=percent weighing
11=other mode
1= not stable| 1= under capacity
1
| 0= not at zero point| 0= not over capacity
1= at zero point| 1= over capacity
2
| 0=RAM ok| 0=ROM ok| 0= gross weight| 0=not in HOLD
1= RAM error| 1=ROM error| 1= net weight| 1=in HOLD
3
| 0= eeprom OK| 0=calibration ok| 0=initial zero ok| 0=battery ok
1= eeprom error| 1=calibration error| 1=initial zero error| 1=low battery
4| always 1| always 1| always 1| always 1
5| always 1| always 1| always 1| always 1
6| always 0| always 1| always 1| always 0
7| parity| Parity| parity| Parity
Command| Response
---|---
ASCII| HEX
W
**** ①
②
③
| | ④ W1W2W3W4W5 EH-SCP 0 | 0=Stable weight data 1 | 0= Within weighing range 2 | 0=Within weighing range 3 | 0= Within range 4 | 0= Not at center of zero SCP-12 0 | 0=Scale in motion| 1 = Under capacity 1 | 0= Scale at zero| 1 = Over capacity 2 | 0=RAM error| 1 = ROM error 3 | 0= EEPROM error| 1 = Faulty calibration EH-SP2 Becknell USA AWT35-100107 Rev AB Read User Manual Online (PDF format) >>
---|---|---
S
Z
T
U
L
X
others| |
Bit
Status Byte
1=Scale in motion
1= Over capacity
1= Under zero
1= Outside zero capture range
1= Center of zero
5| always 1
6| always 1
7| parity
Command| Response
---|---
ASCII| HEX
W| 57| Read scale weight:
| | ①general data
②if current weight is invalid
---|---|---
Z| 5a| Simulate ZERO key:
L| 4c| Switch to and send standard weight. Same as W above
K| 4b| Switch to and send metric weight. Same as W above
others| | Un-known commands:
Bit
Status Byte1
Status Byte2
1=Stable| 0 = Not under capacity
1= Not at zero| 0 = Not over capacity
1= RAM okay| 0 = ROM okay
1= EEPROM okay| 0 = Calibration okay
4| Always 1| Always 1
5| always 1| always 1
6| always 0| always 0
7| parity| parity
Command| Response
---|---
ASCII| HEX
W
MM
Status Byte
gg
Scale in motion
GG
Stable weight data
Command
Response
---
---
ASCII
HEX
< CR>
0d
1000 Armstrong Dr.
Fairmont MN 56031
Toll free:800-637-0529
Tel:507-238-8702
Fax:507-238-8271
Email:sales@brecknellscales.com
http://brecknellscales.com
Becknell UK
Foundry lane,
Smethwick, West Midlands
England, B66 2LP
Tel:+ 44 (0) 8452 466717
Fax:+44 (0) 8452 466718
Email:sales@brecknellscales.co.uk
http://brecknellscales.comRead User Manual Online (PDF format)
Download This Manual (PDF format)