top systems M8 Mega ANL and Class T Fuseholders Instruction Manual
- June 13, 2024
- top systems
Table of Contents
top systems M8 Mega ANL and Class T Fuseholders Instruction Manual
Specifications
-
Higher voltages may require additional safety measures
-
For M8 ANL type fuses
-
For M10 ANL type fuses
Removing the top cover
Assembly sequence of nut, washers and cable lugs (see also precaution 4) |
Break out cover sides by hand at required cable access locations
Installation details
Precautions
- Please install this product in a dry, indoor location.
- To avoid fire hazards, use correctly sized cables which are suitable to carry the expected load currents in your application. Please check our website for more information.
- To avoid fire hazards or damaging the fuse holder, please make sure that all nuts are securely tightened. Please apply our recommended torque ratings of 13Nm for M8 nuts and 22Nm for M10 and M12 nuts.
- To avoid fire hazards or damaging the fuse holder, please make sure that spring- and flat washers are always placed directly below the nut. Never place washers between: busbar and cable lug, fuse and cable lug, multiple cable lugs on the same stud, busbar and link plate, cable lug and link plate or fuse and link plate.
- Please make sure that all connection cables are properly strain relieved, to avoid excessive mechanical stress on the fuse holder.
DC Modular features
- Tin plated high purity copper busses provide maximum conductivity.
- Stainless steel studs, washers and nuts for optimal corrosion resistance.
- Unique grid optimized footprints allows space saving arrangements of multiple DC Modular products.
- Special fiber reinforced plastic base offers excellent high temperature properties, good chemical resistance and high strength.
- Common interconnection heights for easy combining of multiple products using optional link plates (not suitable for Mega (300A) and ANL (300A) fuseholders).
- Robust transparent covers with breakouts to allow wire access from any direction.
- Smart terminal design allows dual mirrored cable lug connections.
- Easy in-system fuse and connection access due top locked covers (except Mega (300A) and ANL (300A) fuseholders).
- The DCM Mega Fuseholders are compatible with the following fuse products: Littelfuse® ’Mega’ and Cooper Bussmann® ’AMG’.
- The DCM ANL Fuseholders are compatible with the following fuse products: Cooper Bussmann® ’ANL’ and ’ANN’ and Littelfuse® ’CNN’ and ’CNL’.
- The DCM Class-T Fuseholders are compatible with the following fuse products: Cooper Bussmann® / Edison® ’JJN’ and ’TJN’, Littelfuse® ’JLLN’ and Mersen® ’A3T’.
Top Systems BV | Lemsteraak 6 | 2411 NC Bodegraven | The Netherlands | www.top.systems
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>