Aqua FMCG BWPlus Boot Washer Instruction Manual
- June 13, 2024
- Aqua
Table of Contents
Aqua FMCG BWPlus Boot Washer
Important notes
Explanation of pictograms
It is essential to follow the safety instructions and warnings contained in this manual!
Danger!
Threat to human life and health
Warning!
Possible damage to the machine
Tip!
Draws attention to the use, eg. during startup and other useful information.
Low shoes washing
Place on a canister of liquid cleaning agent / disinfectant
Warning!
Warning of electric shock
Warning!
Rotating components
General remarks
Before beginning operations related to transport, installation, commissioning,
cleaning, maintenance and repair of the device, read this instruction manual.
All persons involved in the execution of these tasks, must observe this
manual. To protect the people and things you should follow all safety rules
contained in this document.
Compliance with the information and recommendations contained in this
document, safety rules and instructions for startup and any other instruction
is necessary in order to avoid hazards and damage.
It is required that all work related to transportation, assembly, installation
(connection to the electricity grid, connection to water and sewage networks),
commissioning, cleaning,
Important notes
maintenance and repairs performed by qualified personnel with the appropriate
permissions. Qualified personnel are persons who, because of their education,
experience and training as well as knowledge of relevant standards, accident
prevention regulations and operating conditions are authorized to perform the
tasks required for mobilization of equipment hygiene. In carrying out the
above mentioned operations should be observed first of all technical data and
information about permissible use, assembly, connected, ambient conditions and
operation described in the product documentation.
In order to avoid malfunctions, the recommended maintenance and inspections
should be performed by trained personnel.
Packaging, transportation, storage
PACKAGING
The manufacturer sends the device protected by two layers of foil:
- outer layer – foil stretch,
- inner layer – foil technology (not applicable to devices with surface polished ceramic).
Before installation steps should be removed from the machine stretch foil and check if the device has not been damaged during transport.
WARNING
It is prohibited to install and run devices damaged.
If in doubt, contact the service.
If not detected any damage to the device, you can remove the foil technology.
TRANSPORTATION
During transport device should be prevented from slipping, falling over,
strong shocks and other mechanical damage.
Internal transport should be means of transport adapted to the dimensions and
weight of the device. When transporting large devices with large weight
manufacturer suggests the use of a pallet truck or forklift.
STORAGE
Before installing and operating the device should be stored in a closed, dry place, protected from mechanical damage.
Sole and leg washing unit for low-heeled shoes
Intended use
Washer used for mechanical cleaning and disinfection of working low-heeled
shoes.
In accordance with the Regulation of the European Parliament and EC Council
no. 852/2004 of
29.04.2004 in hygiene of foodstuffs food market entrepreneur shall ensure
proper hygienic conditions in order to prevent contamination of foodstuffs.
Technical details
No. | Length, mm | Width, mm | Height, mm |
---|---|---|---|
550601 | 850 | 400 | 1100 |
Drive unit: 0.25 / 0.37 kW
- detailed data according to nameplate
Power supply: 400 V, 50 ÷ 60 Hz
Water supply: G ½”
Water discharge: PVC Ø 50 mm
Number of rotary brushes: 1 profiled rotary brush
Actuation: photocell (F) or switch placed in holder (M)
Type of liquid – cleaner
– disinfectant cleaner
– disinfectant
Installation water pressure: 5 ÷ 6 bar
Temp. of water connected to washer: max. 40 ° C
Security level : IP 55
Weight : ~ 30 kg
Design
Washer body are made of stainless steel 1.4301, rotary brushes of plastic,
while shaft support bearings of self-lubricating polyethylene.
The main element of the washer is the body with built-in remaining elements of
the device.
A handle in the form of a properly shaped pipe with a photocell (F) / switch
(M) at the end is adapted to the side wall of the body (the photocell can also
be placed in one of the walls of the washcloth). The body is supported on
adjustable footers. The working element of the washer comprises one profiled
rotary brush. Brush is driven by a gear motor.
Mixed water is supplied to the washer working area (sprayed onto the brush) by
means of spray tubes. Water flow during washer operation is controlled by a
solenoid valve. Water used during the washing process is discharged into the
sewage system through a bottom outlet. The cleaner / disinfectant cleaner /
disinfectant is supplied from the container by means of an injector built into
the plumbing system. The washer electrical system is built-in inside the body,
while the controller box is placed in a safe housing. The device is delivered
with a power supply cable L = 4 metre with a 16 A / 400 V plug with five pins.
Installation
The washer should be installed as per site’s separate technological design.
The washer installation involves:
- It is necessary to clean the water system before connecting the device to it.
- levelling the washer by means of adjustable feet,
- connection to the electrical system, from a 400 V socket – FIVE-WIRE SUPPLY LINE, SOCKET SECURED WITH RESIDUAL-CURRENT DEVICE connection to the electrical system should ensure appropriate direction of brush rotary motion
- connection to the plumbing system via a hose ending with a shut-off valve with strainer filter, connection diameter G ½”,
- connection to the sewage system, ensuring water tightness of connections ( 50 mm).
Device personalization
- Setting cleaner / disinfectant cleaner / disinfectant feeding amount
The amount of liquid fed to the brushes is controlled via the injector knobs (see photo 2.).
In order to control amount of the fed liquid, unscrew the metal plate on the side wall of the body and slide-mounted system in which is arranged an injector (see photo 1). Detailed manual injector was connected to the OMM (Appendix 2).
Operation
In order to wash footwear, the worker should put the foot with the shoe in the
washer (put it on the brush). Then, pressing the switch or closer to the thumb
photocell or put the shoe in the bathtub (photoelectric bath tub). Brush is
started by the control system. Brush is started simultaneously with opening of
the solenoid valve. It enables supply of water to the spray tube. Water flow
activates the injector which sucks in the cleaner / disinfectant – cleaner /
disinfectant from the container. The necessary condition for the intake of
liquid to occur is water intake. The amount of the obtained liquid is directly
proportionate to the amount of collected water but it also depends on the
installation water pressure value and personal settings of the device. The
water sprayed on the brush supports the cleaning process and facilitates
drainage of removed contamination.
Brush will rotate as long as you hold (press) button (switch) or the thumb
will be in range of the photocell or how long will the shoe be in the tub.
Cleaning and maintenance
Cleaning
Due to hygienic reasons, daily cleaning of the washer is necessary. The washer structure enables simple and not requiring the use of additional tools removal of brushes and their preparation for cleaning.
Procedure for cleaning the device:
-
Close the water supply and switch off the main power supply.
-
Remove the brushes by lifting them up.
-
Larger contamination needs to be manually removed from the washer bath.
-
Wash all brushes with high pressure washing equipment using a suitable cleaner and rinse them thoroughly afterwards.
NOTE! Follow the instructions of the cleaning agent manufacturer. -
Spray the entire device with a suitable cleaning agent.
NOTE! Follow the instructions of the cleaning agent manufacturer. -
After a specified time rinse agent used for cleaning the surface of the device.
-
Wipe the photocell with a soft cloth without the use of cleaning agents.
-
Place the washed brushes back in the washer bath.
-
Switch on the main power supply and water connection.
-
Check whether the device is functioning properly.
The device may be cleaned with a pressure device at the following pressure settings ≤ 14 bar.
DO NOT:
- use chloric detergents for washing the device.
Detailed rules of stainless steel maintenance and cleaning have been attached to this OMM (Appendix 1).
Maintenance
Each time after cleaning the device, check all metal parts in terms of their functioning, material wear and tear as well as device tightness.
In order to effectively clean footwear soles and uppers, brushes should have bristle of appropriate length.
Depending on the brush wear, it is possible to replace its the entire brush. In order to replace used up brushes, contact the service.
Repairs and maintenance inspections may be performed only by one trained and authorized person.
Periodical inspections should be performed every 1000 hours after disconnecting the washer from the mains. Inspection should include:
- checking the oil level in the gear motor transmission (according to the instruction of the gear motor),
- checking solenoid valve operation (if necessary, disassemble the valve head and remove the accumulated deposit),
- check the water tightness of connections (if necessary, replace the gaskets).
In case of hard or iron-containing water, perform the valve inspection every 500 h.
Periodically (as per relevant regulations), inspect the condition and resistance of wiring insulation, as well as the effectiveness of neutral grounding.
OHS rules
General Industrial Safety regulations apply.
Utilization
The device must be disposed according to its properties and applicable regulations.
Final remarks
The manufacturer reserves the right to any construction changes.
Guarantee
Statutory guarantee period for this type of devices applies. Failing to comply with the rules herein may result in losing the guarantee rights.
Manufacturer
AWE POLAND, Sp. z o.o.
ul. Inwalidów 3
85-749 Bydgoszcz
tel. 052/345-24-44
WARNING!
The manufacturer is not liable in the event of improper use of the machine and
non-use of the manual.
STAINLESS STEEL MAINTENANCE AND CLEANING
INTRODUCTION
The products of our company are made of 304 grade stainless steel.
304 grade stainless steel is austenitic chrome-nickel low carbon steel. It is
used in food and chemical industry equipment, etc. This steel is corrosion-
resistant in the atmospheric environment, natural water, alkali solutions and
some organic and inorganic acids. Chemical composition of 304 grade stainless
steel:
C < 0.03%;
Si < 1.0%;
Mn < 2.0%;
P < 0.045%;
S < 0.015%;
N < 0.011%;
Cr = 18.0%-20.0%;
Ni = 10.0%-12.0%
PASSIVE LAYER
In stainless steels, oxygen reacts with chrome atoms contained in steel. Chrome atoms and oxygen form a layer of chromium oxide which provides a natural protection against corrosion factors. The above phenomenon is called a surface passivation reaction, hence the resulting protective layer is referred to as a passive layer.
CORROSION
Although, the passive layer is formed on stainless steel surfaces, there are cases when it corrodes due tothe following conditions:
- influence of hydrochloric acid and chlorine,
- no ongoing maintenance which leads to the formation of strong acid solutions on steel walls (water evaporates and an acid solution remains),
- an environment more aggressive than steel provided for it;
- contamination during installation and manufacture (lime, cement, foreign metallic inclusions as a result of using angle grinders nearby or unsuitable assembly tools),
- contact with normal carbon steel (scratching with black steel during transportation or storage),
- insufficient room ventilation or even their absence in aggressive environments (there must always be an air flow in ventilation ducts).
Symptoms of stainless steel corrosion are different. One can notice that
corrosion appears usually on various types of internal (non-metallic
inclusions, separations, deformations) and external (edges, scratches, dents,
residues of scale, sediments, etc.) surfaces, while smooth and homogeneous
surfaces are much more resistant to corrosion. Therefore, it is necessary to
ensure proper pickling and passivation of a surface.
The mechanism of destruction and the type of corrosion depend on a specific
environment and steel affected by it. The following types of corrosion may
occur depending on the environment and stainless steel:
- surface (uniform),
- pitting,
- intergranular,
- stress,
- crevice.
Pitting corrosion is the most frequently occurring corrosion caused by
inappropriate stainless steel maintenance, more specifically due to the use of
chlorinated cleaning agents.
Pitting corrosion is a form of a localised environmental attack leading to
local losses (pits) in material. It is caused by the influence of galvanic
cells formed between a passivated steel surface and clearly localised non-
passivation areas laying on it. Oxygen or oxidising substances in a cathodic
cell areas (passivated) are required for pitting corrosion to occur. If they
are absent, cathodic areas polarize and the cell stops functioning.
Solutions which cause pitting corrosion of stainless steels most frequently
are chlorine solutions. For this type of corrosion, condition of a steel
surface is very important. The smoother and cleaner the surface, the smaller
the intensity of the said corrosion.
A quality assessment of the effects of this type corrosion is difficult since
damage can be very serious at a minor weight loss. It is assumed that an
average number of pits per area unit and their greatest depth can serve as
some indicators.
MAINTENANCE AND CLEANING
When using stainless steel furniture and equipment, a layer of chromium oxide
present on the steel surface must be taken care of. Compounds used in food
industry which disturb the passive layer (chromium oxide) include compounds
containing chlorides – salt, disinfectants and acids (water from sauerkraut,
cucumbers, acid juices, vinegar, etc.). Water is the most effective
neutraliser of chlorides and weak acids.
Of course, each material requires to be kept clean. Stainless steel is not an
exception to this rule and each user must be aware that regular cleaning and
maintenance of stainless products is required.
Cleaning should remove dirt and sediments, which left for too long on a
stainless steel surface may initiate corrosion and tarnishing of the surface.
In a highly contaminated or aggressive environment (seaside towns, rooms of
increased humidity and temperature, rooms requiring frequent use of
disinfectants, in particular containing chloride compounds), cleaning should
be done more frequently. The frequency of cleaning should be empirically
determined.
In order to prevent a surface of stainless steel equipment from being destroyed due to inappropriate maintenance, the following guidelines should be complied with:
- The following should not be used: agents containing chlorides and bleach or – under no circumstances – silver cleaners.
- Steel wool, sand paper, rough cleaners, scouring, grinding and polishing powders, etc. shall not be used as they scratch the surface.
- Steel pads for scouring or wire brushes shall not be used – they can leave sediments of carbon steel on the surface which will eventually lead to material rusting.
- First discolouration and dusts appearing during material use can be removed with a regular piece of cloth, chamois leather or a nylon sponge in case of higher contaminations.
- If iron particles generated during installation, etc. appear on stainless steel components, they should be immediately removed. Such particles corrode, thus they can break the passive layer protecting stainless steel, leading to corrosion as a result. Such sediments should be removed mechanically or with stainless steel cleaning agents.
- If there are pits on a component, they should be pickled with acid or removed mechanically.
- Local discolouration, grease marks – if small, they can be removed with soap water.
- Products for cleaning stainless steel and alcohol-based preparations can be used for cleaning they do not pose a threat to the corrosion properties of stainless steel.
- After cleaning, it is always recommended to polish the surface with a dry piece of cloth.
The table below presents the most frequent types of contaminations and methods of handling:
The table below presents the most frequent types of contaminations and methods of handling:
Contaminations | Cleaners |
---|---|
Finger marks | Water with soap and detergent |
Glass cleaning agents without chlorides
Lime sediment| Vinegar-water solution
Oils and greases| Alcohol-based agents (only with methyl alcohol,
isopropyl alcohol) Solvents, e.g. acetone
Paints| Agents for removing paint coating, based on alkaline compounds
or solvents
Cement and mortar| Solvent containing a small amount of phosphoric acid,
then water
Iron particles – from tools and after contact with structural steel|
At an early stage – mechanically
If pits appear – with pickling and passivating pastes
The frequency of cleaning components made of stainless steel is individual – it all depends on the degree of wear and contamination. It should be done in such intervals so as to reduce the risk of stainless steel component rusting. The frequency of cleaning of stainless steel devices is analogous to the frequency of cleaning household sinks, stainless steel.
OHS RULES
Prior to proceeding with cleaning, it is absolutely required to read data sheets of products applied for cleaning and follow manufacturers’ guidelines. It is necessary to use personal protective equipment, ensure adequate ventilation and pay attention to fire hazards.
ADJUSTABLE SINGLE INJECTOR
INSTALLATION INSTRUCTION
INSTALLATION
The injector may be installed in any position in the water line with the arrow in the director of flow. Drop end of plastic tubing with strainer into fluid product container. Cut tubing to convenient length, and slip open end over injector fitting.
OPERATION
Warning: Use care when handling hazardous chemicals.
Note: The injector will not operate if the input water temperature exceeds
70 ° C.
See Fig. 1 for location of water bypass screw and fine metering adjustment
screw. Turn on water supply valve. The injector may draw momentarily as the
system is filling but normally will stop as the system builds up to full
pressure. To actuate injector, turn the bypass screw clockwise until product
begins to be drawn from the container. After the fluid reaches the injector,
the feed rate may be adjusted to the desired rate by turning the bypass screw.
The maximum injection rates are shown in Table 2. For low injection rates, it
is advisable to set the bypass screw for more injection than required; then
turn the fine metering screw clockwise to reduce injection to the desired
rate. Table 1 shows the operation range of the injector. If the injector will
not draw with the bypass screw full in, then the water flow is below the range
of the injector. If the injector draws with the screw full out but pressure
lose is excessive, then flow is above the range of the injector.
TABELE 1
Water Pressure
( bar)
| Operating Range (Liter per Minute)
---|---
0,7| 1,9 – 13,2
1,4| 2,1 – 16,6
2,8| 2,7 – 20,4
4,1| 3,0 – 24,2
6,9| 3,8 – 30,2
13,8| 5,3 – 41,6
27,6| 7,2 – 56,7
34,5| 7,9 – 64,3
- 48,3| 9,5 – 75,6
- 68,9| 11,2 – 86,9
- 103,4| 13,2– 105,8
- 137,9| 17,8 – 139,9
- 206,8| 18,9 – 170,1
*SPECIFY – S Stainless Steel Knob – Part No. 24-32S or Part No. 24-32ST (for tips) for pressure exceeding 48,3 bar.
TABELA 2
Fluid Viscosity (cps) | Maximum Injection (l/min.) |
---|---|
1 | 0,5 |
75 | 0,25 |
200 | 0,12 |
**SERVICING
**
CAUTION: Turn off water supply before servicing.
The check valve parts are in the metering knob and can be cleaned by removing the four screws. The knob may be rotated if it is more convenient to have the adjusting screw on another side of the injector. As with any injector, if spray jets become clogged or downstream restriction increases in any manner, the injector will stop drawing fluid. If it is inconvenient to remove the restriction immediately, the injector may be put back into operation by turning, the water bypass screw further clockwise; this adjusts the injector to the lower flow rate. The bypass screw should be reset once the restriction is removed.
CAUTION: When servicing, make sure that replacement parts have been installed according to drawing. Be certain to check valve parts are in place.
SPARE PARTS
NO. | PART NO. | DESCRIPTION |
---|---|---|
1 | 24-33 | Screw #8 – 32 x 7/8 Lg. (4 Reqd.) |
2 | 24032 | Metering Knob Assy. |
3 | 24032PS | Metering Knob Assy. |
4 | 24-32S | Metering Knob Assy. (Stainless) |
5 | 24-32ST | Metering Knob Assy. (Stainless Steel with Tips) |
6 | 24-32T | Metering Knob Assy. (Tips) |
7 | 100-24 | Metering Screw |
8 | 100—24PS | Metering Screw (-BP Injectors) |
9 | 24-25 | Check Valve O-Ring (EP) |
10 | 24-24P | Check Valve Ball (Teflon) |
11 | 24-24S | Check Valve Ball (Stainless) |
12 | 24-23 | Check Valve Spring |
13 | 24-34- | Check Valve Core (Specify Model No.) |
14 | 25-29 | O-ring (EP) |
15 | 100-12 | Vinyl Tubing (3/8” OD x 8’ Lg.) |
16 | 61-107-2 | Ceramic Weight (1/4” ID, 3/8” OD Tubing) |
17 | 24-11MP | Foot Strainer |
21 | 24-36 | By-pass Screw Retainer |
22 | 24-25 | O-Ring (EP) (7/32 x 11/32 x 1/16) |
23 | 24-35 | By-pass Screw |
FMCG Industry Solutions Pty Ltd
ABN 22 135 446 007
****Factory 11A, 1 – 3 Endeavour Rd, Caringbah NSW 2229
www.fmcgis.com.au
sales@fmcgis.com.au
1300 628 104 or 02 9540 2288
References
- Azot – Wikipedia, wolna encyklopedia
- Chrom – Wikipedia, wolna encyklopedia
- Fosfor – Wikipedia, wolna encyklopedia
- Krzem – Wikipedia, wolna encyklopedia
- Mangan – Wikipedia, wolna encyklopedia
- Nikiel – Wikipedia, wolna encyklopedia
- Siarka – Wikipedia, wolna encyklopedia
- Węgiel (pierwiastek) – Wikipedia, wolna encyklopedia
Read User Manual Online (PDF format)