CAME ZLJ24 Control Board Instruction Manual

June 13, 2024
CAME

CAME ZLJ24 Control Board

CAME ZLJ24 Control Board

Control Board

Control Board

Electrical connections

TSP00 – Transponder sensor
LT001 – Magnetic card reader

Electrical connections
N.B.: insert the (R700) coding board to have the (TSP00) sensor or (LT001) card reader recognised.

L-N Power supply 230 V DC 50/60 Hz
M1-N1 24 V DC gearmotor (FROG A24/A24E – F1024 – F4024/E) featuring delayed action on opening
M2-N2 24 V DC gearmotor (FROG A24/A24E – F1024 – F4024/E) featuring delayed action on closing
2-FA1-FC1 Endstop (FROG A24 – F1024 – F4024) featuring delayed action on opening
2-FA2-FC2 Endstop (FROG A24 – F1024 – F4024) featuring delayed action on closing
M1-N1-E1 24 V DC gearmotor (AXO) featuring delayed action on opening
M2-N2-E2 24 V DC gearmotor (AXO) featuring delayed action on closing
M1-N1 24 V DC gearmotor (FROG A24E – F7024E) featuring delayed action on opening
M2-N2 24 V DC gearmotor (FROG A24E – F7024E) featuring delayed action on closing
+ E – Encoder A (FROG A24E – F7024E) featuring delayed action on opening
+ E – Encoder B (FROG A24E – F7024E) featuring delayed action on closing

10-11 Terminals for powering 24 V DC accessories
10-E Cycle lamp / Flashing light (socket rating: 24 V – 25 W max.)
10-5 Open gate indicator-light (socket rating: 24 V – 3 W max.)
11-ES Electro lock connection (12 V – 15W max)
2-CX..CY..CZ Re-open during closing (N.C.) socket, re-close during opening, partial stop or stand-by Obstacle
1-2 Stop button (N.C. contact)
2-3 Opening button (N.O. contact)
2-4 Closing button (N.O. contact)
2-3 P Partial opening button (N.O.)
2-7 Keys itch and/or commands button (N.O.)
B1-B2 Possible output of the radio receiver’s second channel (N.O.).
Socket rating: 1 A – 24 V DC. Antenna connection

Electrical connection for the photocells functions test

Electrical connection for the photocells functions
test
Electrical connection for the photocells functions
test

At each opening and closing command, the control board assesses the efficiency status of the control devices (photocells). Any anomaly found is signaled with the flashing of the LED on the control panel. Consequently it cancels any commands coming from the remote control or the button.

Electrical connection to enable the photocell safety test:

  • the transmitter and the receiver, must be connected as per the diagram;
  • from the functions menu, select “safety tests” and select either CX – CY – CZ input/s to activate the test.

Restore backup: to load the data saved on the memory roll onto card A

Restore backup: to load the data saved on the memory roll onto
card

To reset the previous configurations insert the “Memory Roll” and read the data as shown in the figure.
Note: If you have saved the settings in the “Memory Roll”, you will have to reset all the settings as explained in the panel’s original manual. You can request a copy from you local assistance provider.

Restore backup: to load the data saved on the memory roll onto
card

Disposal

This product, including the packaging, is made up of several types of materials that can be recycled. Investigate the recycling or disposal systems of the product, complying with prevailing local legislation. Some electronic components may contain polluting substances. Do not litter.

The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelling automatics s.p.a. to notify users.

Customer Support

GAMEWorld

UNITED KINGDOM – CAME United Kingdom Ltd. AME United Kingdom Ltd.
Unit 3 Orchard Business Park – Town Street, Sandiacre
Nottingham Ng10 5du – (+44) 115 9210430 – (+44) 115 9210431
BELGIUM – CAME Belgium Sprl AME Belgium Sprl
Zoning Ouest 7
7860Lessines – Lessines – (+32) 68 333014 – (+32) 68 338019

CAME-Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals