KINGgates FREDDY2 Universal Radio Receiver for Electric Gates Instruction Manual
- June 12, 2024
- KINGgates
Table of Contents
- FREDDY2 Universal Radio Receiver for Electric Gates
- EU DECLARATION OF CONFORMITY
- DISPOSAL
- PRODUCT DESCRIPTION AND INTENDED USE
- RELAY CONTACTS
- TECHNICAL DATA
- PROGRAMMING
- SELECTION OF THE RECEIVER CHANNEL
- PROGRAMMING OF THE MONOSTABLE FUNCTION
- REMOTE RADIO LEARNING
- CANCELLATION OF A SINGLE TRANSMITTER
- TOTAL CANCELLATION OF TRANSMITTERS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FREDDY2
12/24V outdoor receiver.
Installation and use instructions
Made in Italy
FREDDY2 Universal Radio Receiver for Electric Gates
EU DECLARATION OF CONFORMITY
The manufacturer V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy declares that the products: FREDDY2
comply with the following directives:
- 2014/53/UE (RED Directive)
- RoHS-3 2015/863/EU
Racconigi, 01/03/2023
Legal representative of V2 S.p.A.
Roberto Rossi
DISPOSAL
As for the installation operations, even at the end of this product’s life
span, the dismantling operations must be carried out by qualified experts.
This product is made up of various types of materials: some can be recycled
while others need to be disposed of.
Find out about the recycling or disposal systems envisaged by your local
regulations for this product category.
Important! – Parts of the product could contain pollutants or hazardous
substances which, if released into the environment, could cause harmful
effects to the environment itself as well as to human health.
As indicated by the symbol opposite, throwing away this product as domestic
waste is strictly forbidden. So dispose of it as differentiated waste, in
accordance with your local regulations, or return the product to the retailer
when you purchase a new equivalent product.
Important! – the local applicable regulations may envisage heavy
sanctions in the event of illegal disposal of this product.
PRODUCT DESCRIPTION AND INTENDED USE
The receivers in this series are intended for controlling the automation type
door openers, gate openers and the like, lights and electrical circuits in
general.
Any other use is improper and prohibited!
Specifications:
-
Monostable, bistable or timer operating logic.
-
Possibility to select the contact type (N.A or N.C.) of the relay 1 through a dedicated jumper J1.
The contact of relay 2 is of N.A. type, to have an N.C. contact.
It is necessary to make changes to the hardware of the printed circuit -
It is possible to store up to 504 different codes with self-learning mode
-
Memory full warning: the receiver blinks 15 times
-
Self-learning of transmitters managed by radio
RELAY CONTACTS
The contacts to the terminal board concerning the four relays are of normally
open (N.O.) type.
For a normally closed (N.C.) contact of relay 1, move the jumper J1 to
position 2 (Fig. 1).
For a normally closed contact (N.C.) of relay 2 short-circuit point A with
point B and cut the track at point C (Fig. 2) of the relay concerned.
TECHNICAL DATA
Frequency | 433,92 MHz |
---|---|
Power supply | 12 – 24 Vac / 12 – 36 Vdc |
Relay contacts | 1A / 30Vdc |
Temperature | -20 ÷ +60°C |
Consumption | 16 mA @ 24Vdc (stand by) |
Sensibility | ≥ -103 dBm |
S/N | > 17dB @ 100dBm m=100% |
Size | 132 x 26 x 74 mm |
Protection degree | IP55 |
PROGRAMMING
IMPORTANT: to memorize the code in the correct way it is necessary to
keep a minimum distance of 1,5 metres between the transmitter and the
receiver’s antenna.
The self learning programming system enables the code memorization and the
setting of the following functioning modes:
MONOSTABLE: it activates the corresponding relay through the time of TX
transmission. When the transmission stops, the relay goes automatically off.
BISTABLE: it activates the corresponding relay on the first TX transmission.
The relay goes off on the second transmission.
TIMER: the tx transmission activates the corresponding relay which goes off
after the set time (max 7,5 minutes).
SELECTION OF THE RECEIVER CHANNEL
To select the channel of the receiver to be programmed, press the P1 button for N times, as indicated in the table: the LED corresponding to the selected channel turns on
SELECTED CHANNEL | N° IMPULSES P1 | LED ON |
---|---|---|
Ll | L2 | |
CHANNEL 1 | 1 | • |
CHANNEL 2 | 2 |
PROGRAMMING OF THE MONOSTABLE FUNCTION
- Select the channel of the receiver to be programmed
- Within 5 seconds, press and hold the button on the remote control (about 2 sec.)
- The led of the receiver goes out and goes on again: the code has been memorised and the receiver remains standby for 5 s with a new code to be memorised
- Memorise all the remote control units necessary
- After 5 seconds without a valid transmission, the led is turned off and the receiver returns to normal operating mode
PROGRAMMING THE TIMER FUNCTION
- Select the channel of the receiver to be programmes and hold pressed the P1 button: the LED corresponding to the selected channel will turn on for a few seconds
- When the led goes off, release the P1 button.
- The led starts a sequence of flashings at low speed (1 flash per second). The number of flashing corresponds to the time which can be set as shown in the table.:
N° Flashing| Time
---|---
1| 01 sec.
2| 02 sec.
3| 03 sec.
4| 04 sec.
5| 05 sec.
6| 06 sec.
7| 07 sec.
8| 08 sec.
9| 09 sec.
10| 10 sec.
11| 11 sec.
12| 12 sec.
13| 13 sec.
14| 14 sec.
15| 15 sec.
16| 30 sec.
17| 1 min.
18| 1,5 min.
19| 2 min.
20| 2,5 min.
21| 3 min.
22| 3,5 min.
23| 4 min.
24| 4,5 min.
25| 5 min.
26| 5,5 min.
27| 6 min.
28| 6,5 min.
29| 7 min.
30| 7,5 min.
31| BISTABLE - Count the number of led flashings corresponding to the time you wish to set
- Press the rx button P1 during the wished flashing: the sequence of flashings stops and the led remains on
- Within 5 seconds, press and hold the button on the remote control (about 2 sec.)
- The led on the receiver is turned off and then comes on again: the code has been memorised and the receiver remains standby for 5 s with a new code to be memorised
- Memorise all the remote control units necessary
- After 5 seconds without a valid transmission, the led is turned off and the receiver returns to normal operating mode
PROGRAMMING OF THE BISTABLE FUNCTION
- Select the channel of the receiver to be programmes and hold pressed the P1 button: the LED corresponding to the selected channel will turn on for a few seconds
- When the led goes off, release the P1 button.
- The led starts a sequence of flashings at low speed (1 flash per second). When the 30 flashings of the timer function are over, the led remains on.
- Within 5 seconds, press and hold the button on the remote control (about 2 sec.)
- The led on the receiver is turned off and then comes on again: the code has been memorised and the receiver remains standby for 5 s with a new code to be memorised
- Memorise all the remote control units necessary
- After 5 seconds without a valid transmission, the led is turned off and the receiver returns to normal operating mode
REMOTE RADIO LEARNING
This procedure allows to memorize new transmitters by radio, in sequence and
without removing the receiver from the installation.
The transmitter which allows to enable the programming by radio must be
memorized in advance.
The keys of all the transmitters saved in the memory via radio will have the
same logic as for those of the transmitter that enabled programming.
Therefore, if the transmitter that activated programming has key 1 saved only,
the new transmitters can only be saved using key 1.
- Press for at least 4 seconds the keys 1+2 of one transmitter that is already saved
- Release both keys
- Press, within 5 seconds, the key of the new transmitter that you intend to save
- Release the key and repeat the procedure for the other keys of the remote control or with other radio controls to be saved
CANCELLATION OF A SINGLE TRANSMITTER
- Turn off the power to the receiver
- Holding down the P1 key, reactivate the power supply: LED L1 lights up steadily for a few seconds then starts flashing
- During flashing, release the P1 key: LED L1 turns on steadily
- Hold down a key of the transmitter that you want to delete: LED L1 turns off and on again
- Release the key: the transmitter has been deleted (all keys memorized) and the receiver remains on hold for 5 sec. of another transmitter to be deleted
- After 5 seconds without any operation, the LED turns off and the receiver returns to normal operation
NOTE: if you try to delete a transmitter that is not memorized, the L1 LED flashes multiple times
TOTAL CANCELLATION OF TRANSMITTERS
- Turn off the power to the receiver.
- Holding down the P1 key, reactivate the power supply: LED L1 lights up steadily for a few seconds then starts flashing
- Keep the button pressed until LED L1 remains on steady
- Release the P1 key: the total cancellation is started and ends after a few seconds when the LED goes out
+39 0172 1812574
Technical support
Monday/Friday 8.30-12.30 ; 14-18
(UTC+01:00 time)
CODE: ZIS631 – 11/07/2023
Installer details
Company……
Address………..
Province………
Tel…..
Contact person……….
Stamp………
Manufacturer’s details
**** Brand of V2 S.p.A.
Corso Principi di Piemonte 65/67 – 12035 RACCONIGI CN (ITALY)
info@king-gates.com
– www.king-gates.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>