DAVIES CRAIG THERMATIC Fan Switch Instruction Manual
- June 12, 2024
- DAVIES CRAIG
Table of Contents
- THERMATIC Fan Switch
- Changing Airflow Direction:
- Mounting Instructions:
- Controlling the Thermatic® Fan.
- [0445, #0448, #0435, #0438 & #0500). (Sold separately)
- Wiring Instructions:
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
World’s best auto cooling
THERMATIC Fan Switch
Instruction Manual
THERMATIC Fan Switch
THERMATIC® FAN INSTALLATION INSTRUCTIONS
Suitable for Davies Craig: 8”, 9”, 10” Slimline, 10” High Power, 12”, 12” High
power, 14” Slimline, 14” High Power and 16” Fans (12V & 24V)
BEFORE COMMENCING INSTALLATION, PLEASE READ THESE INSTRUCTIONS THOROUGHLY.
FAILURE TO COMPLY MAY VOID YOUR WARRANTY
All Davies, Craig Thermatic® Fans include 4 mounting feet. All Davies, Craig
Thermatic® Fans are designed for both UPSTREAM and DOWNSTREAM applications.
They are factory assembled to be mounted Upstream.
Changing Airflow Direction:
Remove the clip or undo the hex nut, depending on model, from the centre of
the fan blade.
Remove the fan blade from the motor shaft, turn it over and replace. In every
case the instruction, printed on the blade, ‘This side must face front of
vehicle’ and ‘this side must face rear of vehicle’ must be followed.
Re-secure the fan blade.
For 14” and 16” fans ensure the washer is located underneath the clip
For 8”, 9”,10” and 12” fans ensure the blade spacer remains in place with
smaller diameter is towards the motor and larger diameter towards the blade.
Ensure the hex nut is tight, if possible, torque the Hex Nut to 2.7 N.m (2
ft.lbf).
Before mounting the fan to the face of the radiator/condenser, note the
direction of the arrow on the fan blade. The fan must rotate in the indicated
direction.
Mounting Instructions:
When mounting the fan, take care not to cause any distortion to the shroud.
NOTE: The small holes around the perimeter of the fan are intended for
use with the Quick fit kit, not bolts. When using bolts, it is recommended to
use the mounting feet (supplied) or M6 nuts inserted into the mounting feet
slots.
Take the 4 mounting feet supplied and install them onto the Fan Shroud in the
desired locations around the perimeter of the shroud.
Position the Fan against the radiator core or air conditioning condenser core.
If using Parts #1000, #1001, #1002 or #1003 use the provided hardware to mount
the fan to the core as per the instructions provided. Otherwise,
Quick Fit Kit Part #0579 or Mounting Hardware Part #0578 can be purchased
separately.
When installing the fan to the core don’t use excessive force as this can
result in damage to the core. Your Fan MUST rotate in the direction indicated by the arrow
and the instruction on the hub of the fan blade “This side must face front of
vehicle” must be complied with in all cases.
Controlling the Thermatic® Fan.
The Thermatic® fan can be wired to run continuously or manually switched on
and off. For optimal control, Davies, Craig recommends the use of a Thermal
Fan Switch.
Davies, Craig has a full range of Thermatic® Switches available in both
mechanical (#0401, #0404 & #0400) and Digital Thermatic® Fan Switches (#0444,
0445, #0448, #0435, #0438 & #0500). (Sold separately)![DAVIES CRAIG THERMATIC
Fan Switch - fig 3](https://manuals.plus/wp-content/uploads/2023/08/DAVIES- CRAIG-THERMATIC-Fan-Switch-fig-3.jpg)
Wiring Instructions:
It’s recommended you disconnect the battery before installing your fan.
When using a Thermatic® Switch, follow the installation instructions provided
with your product.
The wiring diagram below is for basic fan operation. The switch can be a
manual or a Thermal Switch.
Make a temporary connection of the two wires from the motor to power and
earth.
Run the fan,
if it turns in the direction of the arrow, make the connections permanent.
if not swap the motor leads and make the connections permanent. These installation instructions
may suit most applications but there are circumstances surrounding some engine
designs, environments, and the nature of the system involved, which may
require other installation arrangements not outlined here. Frequently Asked
Questions (FAQ) are listed on our website:
www.daviescraig.com.au. Emails can be
directed to info@daviescraig.com.au or +61
(0) 3 9369 1234 during business hours.
WARRANTY
Davies, Craig Pty Ltd warrants Electric Fans and Transmission Oil Coolers for
a period of three years or 2000 hours continuous running (whichever is the
lesser) from the date of purchase. Davies, Craig Pty Ltd warrants Electric
Water Pumps (EWP), Electric Booster Pumps (EBP), Controllers, Switches and
Accessories for a period of two years or 2000 hours continuous running
(whichever is the lesser) from the date of purchase. Davies, Craig shall carry
out, free of cost, any repairs that are reasonably necessary to correct any
fault in the operation of your Davies, Craig product provided that such a
fault is directly attributable to a defect in the workmanship or materials
used in the manufacture of the part(s). This warranty is void if the product
is misused, altered, tampered with, or is installed or used in a manner that
is inconsistent with Davies, Craig’s written recommendations and/or
installation instructions. Labour and consequential costs are excluded. TPMS
products carry a 1-year warranty.
DAVIES, CRAIG PTY. LTD.
To make a warranty claim, go to:
daviescraig.com.au/warranty
61-67 Taras Av (P.O. Box 363)
Altona Nth, Vic 3025 Australia
Phone: +61(0)3 9369 1234
Fax: +61(0)3 9369 3456