SAL Lighting S9141TC2WH 92mm Tradegem II LED Downlight Instructions

June 12, 2024
SAL Lighting

SAL Lighting S9141TC2WH 92mm Tradegem II LED Downlight

SAL-Lighting-S9141TC2WH-92mm-Tradegem-II-LED-Downlight-
fig-1

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and AS/NZS Standards, which require installation in accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.

SPECIFICATION

SAL-Lighting-S9141TC2WH-92mm-Tradegem-II-LED-Downlight-
fig-3

Electrical class Fitting Ill, Driver 11 Beam angle 110°
Power factor >0.9 Earth Leakage current <lmA
Operating ambient min/max (0C) 0 to 25 Storage ambient limit (0C) 0 ta 60
Operating humidity +l0% ta 85% RH, NC Storage humidity +l0% to 85% RH, NC
Calculated TM – 21, L70 @ 85 °C (hrs) 59,000 Reported TM-21, 85 °C,L70
(hrs) >36,000
Aiming restrictions (if any) No Product application Interior residential,

commercial spaces
IK rating (if relevant)| N/A| Product installation orientation| Horizontal ceiling mount, recessed
CCT (K) switch control (TC)| Yes| Dimmable| Yes
Insulation cover rating (if any)| IC-4 (for NZ IC-F)| PIXIE connectivity| Yes switch & dimming
Replaceable LED| No (see clause 8)| IP rating| IP20 from above ceiling, IP44 from below ceiling
User replaceable LED| No (see clause 8)| Attachment type| X
IP rating for interior products: The designated IP rating is “from below the ceiling” unless otherwise specified.
IP rating ALL products; Termination of the product must be made in accordance with the IP rating.
Earth Leakage current: Is calculated in accordance with AS/NZ 60598.1.2017/Arndt 1:2017.

General product application requirements (if applicable)

  1. CCT or POWER selections (where supplied)- IMPORTANT, where CCT colour temperature or POWER selection switching is provided, it is important to switch OFF the power before the selection is made, otherwise equipment damage may occur.

  2. Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.

  3. Switching or test intervals – For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision of a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications and a six (6) hour duration for Residential applications should be considered.

  4. Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that reflects the installation environment and maintains the product in a clean and functional condition.
    IMPORTANT – The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable cannot be replaced and the luminaire must be destroyed.

  5. Adverse, corrosive and coastal installation environments – Unless the product is specifically designated for such applications in these installation instructions, which is supported by a professional maintenance program; installation of equipment in such environments is not recommended.

  6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party changes in dimmer compatibility.

  7. Suspended products- For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.

  8. Light source replacements – (Non-replaceable light sources) – The light source of the product is deemed not replaceable, when the product reaches its end of life the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) – The light source of the product must only be replaced by the manufacturer or qualified installer. Caution, risk of electric shock.

  9. Interior downlights and sensors with remote drivers and electrical accessories – The mounting facilities provided for the transformer/driver (if any), need only be utilized if in the application of the product is required by AS3000. Drivers are not designed for installation environments that restrict conventional airflow.

  10. Floodlight products – Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and 15 metres in height, subject to the desired optical performance being achieved. For floodlight installation environments that have restricted access (eg: columns and roof ines) which are subject to unstable electrical supply or electrical surges (which void warranty), consideration of the installation of an independent surge protector is strongly recommended.

  11. Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific emergency commissioning instructions, this battery MUST be connected at the time of installation.

  12. Specific installation procedures (if any) – this device must be installed by a licensed electrician:

SAL-Lighting-S9141TC2WH-92mm-Tradegem-II-LED-Downlight-
fig-2
SAL-Lighting-S9141TC2WH-92mm-Tradegem-II-LED-Downlight-
fig-4

  *  **NOTE:** (1) CG* – Remote control gear provided (if any) must not be covered.
  *  **NOTE:** (2) IC ratings shown (if any are made in accordance with AS/NZS6058 test procedures that stipulate the type of insulated material composition covering an IC-4 rated product being equivalent to formed insulation, where 200mm is equivalent to an Rl 4.0 classification in accordance with AS/NZ4859.1.
  1. Warranty – In accordance with SAL’s standard terms and conditions of sale, SAL warrant this product to be free from defects in materials and or workmanship for a period as stated below for goods not subject to incorrect installation, maintenance, operation, mishandling, environmental, unauthorised modifications or electrical operating conditions outside the nominated product specification as detailed in these installation instructions. The benefits to you given by this warranty are in addition to other rights and remedies you have under law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
    Warranty term – Residential usage (60) months, Commercial usage (36) months, Replaceable Lamps (where supplied) (12) months and Lithium batteries where supplied (24) months from date of purchase. For New Zealand, please refer to www.sal.co.nz for warranty conditions and service.

How to make a claim?

  • Step # 1 – Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following
    information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.

  • Step # 2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;

SAL-Lighting-S9141TC2WH-92mm-Tradegem-II-LED-Downlight-
fig-3

  • Step # 3 – Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be returned to SAL as per the above nominated locations.
  • Step # 4 – Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of installation, product removal, return freight and or testing fees are not the responsibility of SAL.

ABOUT COMPANY

  • SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474
  • Copyright SAL VI OCT 2022
  • www.sal.net.au 

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>