cartell CP-4 Automatic Gate Opener Instruction Manual
- June 4, 2024
- cartell
Table of Contents
Instruction Manual
INSTALLATION INSTRUCTIONS FOR CP-4 AUTOMATIC GATE OPENER
CP-4 Automatic Gate Opener
SERIAL NUMBER
There is a barcode serial number on the bottom of “puck” and on the product box. When calling to talk about your product, please have this number handy.
TRENCH PIPE & CABLE
- Trench 1/2″ PVC pipe to the placement of CP-4
- The smooth out the entire length of cable before pulling thru the PVC pipe
- Gently pull cable thru PVC pipe (may need wire lubricant)
CONDUIT & SLIP JOINT
After pulling cable through plastic conduit, insert conduit inside slip joint
on “puck.”
DO NOT GLUE (to uninstall later, if needed).
CONNECT TO THE GATE
CP-4 works with all gate operators―powered or solar, single or dual free exit
terminals.
VOLTAGE | CURRENT |
---|
8-24 VAC
8-30 VDC
| Standby: 30-70 µA
Alarm: 40-60 mA
TEST SENSITIVITY
NOTE: IN MOST CASES DO NOT ADJUST SENSITIVITY OR REMOVE THE LID.
SENSITIVITY ADJUSTMENT
HIGH (Default)
Detects vehicle going
5 MPH 12-14’ away
1 & 2 in OFF position|
MEDIUM
Detects vehicle going
5 MPH 6-8’ away
1 ON & 2 OFF position|
LOW
Detects vehicle going
5 MPH 2-4’ away
1 & 2 in ON position|
NOTE: HIGHEST SENSITIVITY IS WITH DIP SWITCHES IN THE OFF POSITION
NOTE: DIP SWITCH COLOR MAY VARY
BURY CONDUIT & “PUCK”
Trigger gate by swinging steel over puck (or driving by). If the gate opens correctly, bury the conduit and puck at least 5″ – 8″ below the surface.
IF ANIMALS TRAMPLE ON TOP OF A BURIED PUCK OPEN THE GATE, BURY THE PUCK DEEPER, PACK DIRT AROUND IT, AND MAKE IT IMMOVABLE.
OTHER INSTRUCTIONS
NOTE: CP-4 IS NOT A SAFETY. YOU MUST ADD EXTERNAL SAFETY WHEN USING CP-4.
- CP-4 may be installed above ground by screwing a “puck” directly into an immovable object.
- If installed above ground, use a conduit to mechanically protect the cable (animals will eat).
- The vehicle needs to be going at least 5 MPH and must pass the sensor to be detected.
Install CP-4 at least:
- 6-10 feet away from buried power, telephone, or invisible dog fence
- 10 feet away from natural gas lines
- 20 feet away from a power pole with a transformer
- 100 feet back from railroad traffic
- 200 feet away from high power substation power lines
- 80-100 feet back from the gate operator
Technical Specifications
Power Required | 8–24 VAC or 8–30 VDC |
---|---|
Stand-By Current | 30–70 Microamps (μA) |
Alarm Current | 30–40 Milliamps (mA) |
Relay Time | 2–3 seconds |
Relay Contacts | SPDT, floating, N.O. or N.C. (Form C) |
Relay Contact Rating | 1 amp/24 VDC (1 mA at 5 VDC min. load) |
Enclosure Rating | IP68 |
Strength Rating | 9.53 ton-force 8646 kgf |
Temperature Range | -25° F. – +140° F. |
-32° C. – 60° C.
Dimensions| 4.5 in. dia. x 2.5 in. high
11.43 cm dia. x 6.35 cm high
Weight| 5 lbs. (2.7 KG) with 100 ft. cable
The CP-4 complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
WARNING: This product can expose you to chemicals including Acrylonitrile, which is known in the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
RETURNING MERCHANDISE
CONSUMER: Contact your installer
INSTALLER: CALL BEFORE DIGGING UP Call
717-532-0033, option 1 to troubleshoot
and receive a Return Merchandise Authorization (R.M.A.) number. Write the
R.M.A. number on the return shipping box and any correspondence included with
the defective product.
DISTRIBUTOR : Send installers directly to Cartell, citing 717-532-0033( option 1) as a phone number.
5 YEAR WARRANTY
All Cartell products are warranted against defects in material and workmanship
for five years. This warranty does not cover defects caused by, but not
limited to acts of God, improper installation, abuse, fire damage, electrical
surges, integrated system failures, improper lid/gasket installation,
overtightening screws, stripping screw holes, and damage to cable caused by
slicing, pulling, tangling, improper splicing, and failure to run cable in
non-metallic conduit.
CONTACT INFORMATION
TECH SUPPORT | 717-532-0033, option 1 |
---|---|
RMAs | 717-532-0033, option 1 |
SHIPPING | 717-532-0033, option 2 |
ACCOUNTING | 717-532-0033, option 3 |
INSIDE SALES | 717-532-0033, option 4 |
info@cartell.com | |
ORDERING (Distributors only) | orders@cartell.com |
ADDRESS | 510 West King Street Shippensburg, PA 17257 |
WEBSITE | www.cartell.com |
NOTES: ———————-
Copyright © 2022 by Cartell