Graphy GR-THSP-000 Tera Harz Spinner User Manual
- June 12, 2024
- Graphy
Table of Contents
Graphy GR-THSP-000 Tera Harz Spinner
Product Information
The Tera Harz Spinner is a powerful centrifuge designed for aligner production, providing more accurate results. It features a durable and silent operation, along with flexible interior space for efficient resin wash. The device is equipped with a safety rotation control device to prevent aligner shape deformation caused by centrifugal force. It also includes surround inside heating for improved resin flowability and efficient resin discharge. The Tera Harz Spinner is patented by Graphy and offers easy opening and closing, as well as a safety stop feature. It is designed to be light and sturdy, making it easy to place and use. The device is controlled through a digital knob, which allows users to monitor the status and control the operation easily.
Product Usage Instructions
To use the Tera Harz Spinner for aligner production, please follow these instructions:
- Hang the aligner basket securely on the hooks provided with the centrifuge. If you need additional hooks, please request them from Graphy Inc.
- Install the hooks onto the basket and mount the holder securely. Ensure that the basket is correctly installed in the grooves at the bottom of the centrifuge.
- Hang the printed aligners in the basket, making sure that the inside of the aligner faces the wall of the basket. This should be done before detaching the supports from the aligners to avoid damage.
- Place the aligner in the basket, ensuring that the inside of the aligner is facing the wall of the basket.
- Connect the adapter and turn on the power. The centrifuge will automatically turn on.
- After closing the lid (cap), turn the circular panel in front of the centrifuge clockwise to set the desired time. The device will start working 5 seconds after setting the time. You can increase the time further if needed. The device can be reset or paused using the buttons provided.
- After centrifugation, take out the aligner placed on the hook for further processing.
Please note that resin reuse is not recommended as it may affect the 3D
printer and output quality. If using recycled resin, all impurities must be
filtered out using an ultra-fine filter or similar method. The device includes
a resin drawer for quick maintenance, and it is recommended to clean only the
handle of the holder using IPA (isopropyl alcohol). The drawer storage located
at the bottom of the machine allows users to conveniently maintain it
themselves. Please be aware that the device is not designed for user-
detachable parts to minimize rotational vibration during assembly.
Lastly, the Tera Harz Spinner is not limited to aligner production and can be
used for removing residual resin from various prosthetics or shapes depending
on the design of the hook.
INTRODUCTION
This is the video being played. (Digital knob)
Centrifuge to remove the residual resins
For more accurate results Spins even faster Durable, Silent
Efficient resin wash Practical, Fast Flexible Interior Space Safety rotation control d device (No aligner shape deformation by centrifugal force).
Surround inside heating Improved resin flowability Efficient resin discharge
.
Patented by Graphy
OVERVIEW
Video (Operation)
Running at 500 rpm, no shake, no noise
Using a centrifuge to remove the residual resins
- As shown in the left image, there are hooks provided with the centrifuge. The hooks are for fixing the Direct Aligners to the basket.
- If you need the Hook, please request Graphy Inc.
- Install the hooks as shown in the image below. Mount the holder securely to the basket. Please check if the basket is correctly installed in the grooves at the bottom of the centrifuge.
- Hang the printed aligners in the basket and make sure that the inside of the aligner.
- Carry out this process before detaching the Supports from the aligners. Without the Supports, the Direct Aligners may be damaged.
- When placing the aligner in the basket, make sure the inside of the aligner is facing the wall of the basket.
- Automatically turns on when the power is turned on after connecting the adapter.
- After closing the lid(cap), turn the circular panel in front of the centrifuge clockwise to set to 5 (5 minutes. increment by minute). It works after 5 seconds after setting the time. You can increase the time further as needed.
- Reset: On/off with the click of a button
- Pause: Open a below drawer or lid(cap)
- After centrifugation, take out the aligner placed on the hook.
Maintenance
Simple, Easy maintenance
- Resin reuse is not recommended. (affects 3D printer and output)
- If using recycled resin, all impurities must be filtered out. (Using an ultra fine filter, etc.)
- If there are impurities, it may affect the 3D printer and the result.
Resin drawer to facilitate quick maintenance
Basket cleaning
- It is recommended to clean only the handle of the holder.
- The older can be removed by hand.
- It can be cleaned using IPA (isopropyl alcohol).
- It is not necessary to wash the entire basket.
- Drawer storage is located at the bottom of the front of the machine.
- It is designed so that users can conveniently maintain it by themselves.
- It is not a structure that users can detach. (This is because there is a part that needs attention when assembling to minimize rotational vibration.)
Note
- Applicable to multiple 3D printed outputs, not just Aligner Depending on the design of the hook, it is possible to remove residual resin of various prosthetics or shapes.
- Currently, we only have aligner optimized hook designs that can be manufactured according to market needs.
- Caution Do not insert your hand into the machine when rotation is stopped (beep sounds) by stopping or pausing.
- Please install the equipment on a flat and sturdy surface. When placing the aligner on the hook, please align the center of rotation. For example, if two are mounted, it is recommended to position them at 180 degrees.
- If the center of gravity is tilted, friction with the wall may occur and the rotation speed may decrease.
- Before recycling the remaining resin collected in the drawer, check and remove foreign substances before use. (Not recommended)
Specification
- Info Centrifuge for aligner (Using a centrifuge to remove the residual resins)
- Overall Size 390W x 450D x 430H
- Weight 14 kg
- Capacity Max. 16 aligner
- Time 5 min. Automatically turn off Adjustable time
- Function Digital Knob Control Inside heating (works when running) Safety stop (10 seconds)
- RPM 500rpm
- Power 50W
- Rated Voltage BLDC motor : free voltage 100 240v, 5A