HEAT AND GLOW 6K 8K Series Direct Vent Gas Fireplace Instruction Manual

June 12, 2024
HEAT AND GLOW

HEAT AND GLOW 6K 8K Series Direct Vent Gas Fireplace

Product Information

The product is a Direct Vent Gas Fireplace with the following specifications:

  • Actual Dimensions: 6K x 6K
  • Front Width: 41″ [1041]
  • Height: 40-7/8″ [1038]
  • Depth: 21-7/16″ [545]
  • Glass Size: 34-1/4″ x 24-3/4″ [870 X 629]
  • BTU/Hour Input: 16,000 – 30,000 BTUs (NG), 17,000 – 29,000 BTUs (LP)
  • Weight: 163 lbs [74 kgs]

For detailed installation dimensions and requirements, please scan the QR code provided in the user manual.

Product Usage Instructions

BASIC CORNER INSTALLATION:

Adjust the framing dimensions for interior chase sheathing, such as sheetrock. Please refer to the installation manual for additional venting scenarios.

COMBUSTIBLE MANTEL PROJECTIONS:

Measurements in inches:

| To Ceiling| 18| 12| 11| 10| 32| 9| 8| 25| 7| 6| 5
---|---|---|---|---|---|---|---|---|---|---|---|---
| | | | | | | | | | | |
Measurement from fireplace opening to bottom of appliance:| = 33-1/2″| | | | | | | | | | |

Note: Measurement is taken from the top of the opening. Portrait front requires taller combustible clearances or Passive Heat.
Please refer to the installation manual for details.

NON-COMBUSTIBLE MANTEL PROJECTIONS:

| To Ceiling| 18| 12| 11| 10| 9| 8| 7| 32| 25| 19| 18| 17
---|---|---|---|---|---|---|---|---|---|---|---|---|---
| | | | | | | | | | | | |
Measurement from fireplace opening to bottom of appliance:| = 33-1/2″| | | | | | | | | | | |

Note: Measurement is taken from the top of the opening.

EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS:

Wall Penetration: Do not pack vent framing hole with insulation or other material.

  • A: 3″ minimum
  • B*: 10″ minimum

Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch above the center of the horizontal vent pipe. Note: If the overhang (A) is less than 2 inches, clearance from the top of the termination cap to the bottom of the overhang (B) may be 0 inches.

If using heat management, please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting, TV clearances,finishing requirements, fronts, etc., can be found in the installation and owner’s manual.

Specifications

6K
Direct Vent Gas Fireplace

Scan QR code for installation manual for final dimensions and requirements.

Adjust framing dimensions for interior chase sheathing (such as sheetrock)

ACTUAL DIMENSIONS

| FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR INPUT
---|---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 34-1/4″ x 24-3/4″ [870 X 629]| 16,000 – 30,000 BTUs (NG)

17,000 – 29,000 BTUs (LP)

FRAMING DIMENSIONS

| FRONT WIDTH| HEIGHT| DEPTH| WEIGHT
---|---|---|---|---
42″ [1067]| 40-1/8″ [1019]| 22″ [559]| 163 LBS [74 KGS]

Adjust framing dimensions for interior chase sheathing (such as sheetrock)

BASIC CORNER INSTALLATION

Reference install manual for additional venting scenarios

COMBUSTIBLE MANTEL PROJECTIONS

Note: Measurement is taken from top of the opening,NOT the top of the fireplace.
Portrait front requires taller combustible clearances or Passive Heat; see install manual for details.

NON-COMBUSTIBLE MANTEL PROJECTIONS

Note: Measurement is taken from top of the opening, NOT the top of the fireplace.

COMBUSTIBLE MANTEL LEGS OR WALL PROIECTIONS

If A minimum is __ , then **B maximum is __.**

A| Inches| 2-7/16| 3-7/16| 4-7/16| 5-7/16| 6-7/16| 7-7/16
Millimeters| 62| 87| 113| 138| 164| 189
B| Inches| 1| 2| 3| 4| 5| Cl)
Millimeters| 25| 51| 76| 102| 127| Cl)

Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

NON-COMBUSTIBLE MANTEL LEGS OR WALL PROIECTIONS

If A minimum is __ , then **B maximum is __.**

A| Inches| 0-7-7/16| 7-7/16
Millimeters| 0-189| 189
B| Inches| 6| Cl)
Millimeters| 152| Cl)

Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

If using heat management please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting,TV clearances, finishing requirements, fronts, etc can be found in the installation and owner’s manual

EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS

NOTE: If overhang (A) is less than 2 inches, clearance from top of termination cap to bottom of overhang (B) may be 0 inches.

  • A – Measured from back of vent cap to end of overhang
  • B – Measured from bottom of overhang to top of termination cap Vinyl Siding Shield (TRAP-VSS) Information

TRAP-VSS required if overhang (A) is greater than 3 inches but less than 5 inches and B dimension is less than 18 inches.

TRAP-VSS recommended if either of the below is true:

  • Overhang (A) is less than 5 inches (to combat water infiltration)
  • A vinyl overhang is present

WALL PENETRATION

DO NOT PACK VENT FRAMING HOLE WITH INSULATION OR OTHER MATERIAL.

Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25 mm) above the center of the horizontal vent pipe.

Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.