elumen8 Virtuoso 600 Profile WW Filter Frame Runner User Manual

June 12, 2024
elumen8

elumen8 logo Virtuoso 600 Profile WW Filter Frame Runner
User Manual

elumen8 Virtuoso 600 Profile WW Filter Frame Runner -
icon Order code: ELUM136
Virtuoso 600 Profile WW

User Manual

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!

  • Before your initial start-up, please make sure that there is no damage caused during transportation.
  • Should there be any damage, consult your dealer and do not use the equipment.
  • To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
  • Please note that damages caused by user modifications to this equipment are not subject to warranty.

CAUTION!
KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

  • Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
  • Never remove warning or informative labels from the unit.
  • Do not open the equipment and do not modify the unit.
  • Do not connect this equipment to a dimmer pack.
  • Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
  • Only use the equipment indoors.
  • Do not expose to flammable sources, liquids or gases.
  • Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
  • Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
  • Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodicall
  • If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
  • Never touch the fixture during operation as it may be hot.
  • If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
  • If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
  • Only use fuses of same type and rating.
  • Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
  • This lighting fixture is for professional use only – it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
  • Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
  • WARRANTY: Two years from date of purchase.

OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
Please note: These fixtures are intended for stage lighting and entertainment applications only, and are not intended for extended periods of use, including but not limited to house-light, industrial or architectural applications and should only be operated with short duty cycles.

Product overview & technical specifications

Virtuoso 600 Profile WW
The Virtuoso 600 is a compact Profile that features an advanced WW LED system which excels in delivering super smooth dimming and is suitable for many applications. Focus the fixture without DMX signal at the push of a button thanks to the ‘instant focus’ mode. On board features include DMX, RDM and adjustable PWM rate. The fixture is enclosed in a compact, robust chassis and features four framing shutters plus an M size gobo slot further expanding the versatility of this fixture.elumen8 Virtuoso 600 Profile WW Filter Frame
Runner - icon

  • 2 year warranty
  • 1 x 150W warm-white LED (3200K)
  • Manually adjustable beam angle: 25°- 50°
  • 25° – 17,650 Lux @ 2m, 50° – 5,137 Lux @ 2m
  • CRI: 98
  • Refresh rate: 1.2kHz, 2.4kHz, 4kHz, 6kHz or 25kHz selectable
  • Beam framing shutters
  • M size gobo slot
  • DMX channels: 1/2 or 4 selectable
  • RDM (Remote Device Management)
  • Dimmer pack control
  • Manual and master/slave modes
  • 0 – 100% 8 or 16 bit dimming
  • Variable strobe
  • 4 push button menu with LCD display
  • PowerCON TRUE1 input/output
  • 5-Pin XLR input/output
  • 3 selectable fan modes (live, power and studio)
  • Instant fast focus mode
Specifications Virtuoso 600 Profile WW
Power consumption 172W
Power supply 100~240V, 50/60Hz (voltage selector switch)
Fuse T3.15A 250V
Dimensions 370 x 220 x 480mm
Weight 6.1kg
Order code ELUM136

elumen8 Virtuoso 600 Profile WW Filter Frame Runner -
Diagram

Technical specifications

elumen8 Virtuoso 600 Profile WW Filter Frame Runner - Diagram
1elumen8 Virtuoso 600 Profile
WW Filter Frame Runner - Diagram 2

01 – LCD display
02 – Function buttons
03 – PowerCON TRUE1 input
04 – 5-Pin DMX input
05 – Beam framing shutters
06 – 5-Pin DMX output| 07 – PowerCON TRUE1 output
08 – Fuse T3.15A 250V
09 – Hanging bracket adjustment knobs
10 – Safety eye
11 – Hanging bracket
12 – Voltage selector switch
---|---

In the box:
1 x fixture,
1 x safety wire &
1 x power cable

Installation

Before installing the fixture, the supporting structure (ie. truss) must be able to hold a minimum of 10 times the fixtures weight without any deformation (eg. 15kg – 150kg point load). The fixture must be secured with a secondary safety attachment when being installed (ie. an appropriate safety cable).
Never stand directly below the fixture when mounting, removing, and/or servicing.
Overhead installation requires experience and qualifications to calculate working load limits, the material being used at the installation area and periodic safety inspections of the fixture and installation material. If you do not have the relevant experience and/or qualifications please do not attempt the installation yourself. The installation should be checked annually by a qualified person.elumen8 Virtuoso 600 Profile WW Filter Frame Runner -
Diagram 3The Elumen8 Virtuoso 600 Profile WW can be operated in a number of mounting positions as shown in the diagram above, hanging upside-down from the ceiling or truss, mounting sideways on truss or stood upright on a flat level surface. Always use a safety wire as an extra safety precaution to prevent damage/injury in the event a clamp fails (see the next page for clamp installation). Never use the carry handles for secondary attachments.

Installation:

  1. Fasten the clamp to the fixtures bracket with a bolt and lock nut through one of the mounting holes.
  2. Mount the fixture onto your truss system via the clamp and tighten to ensure secure.
  3. Pull the safety cable through the fixture bracket and around the truss.

elumen8 Virtuoso 600 Profile WW Filter Frame Runner - Diagram
4

Focus adjustment

Beam Focus:

  1. Loosen the beam focus knobs located at the bottom of the barrel.
  2. Slide the lens tube forward or backward until you achieve the desired focus.
  3. Once the fixture is focussed, tighten the beam focus knobs.

elumen8 Virtuoso 600 Profile WW Filter Frame Runner - Diagram
5 Shutters:
The shutters are located inside the barrel. They can be adjusted via the shutter handles to adjust the shape of the beam.elumen8 Virtuoso 600 Profile
WW Filter Frame Runner - Diagram 6

Operating instructions

Main Menu| Sub Menus| Values (Default Settings in BOLD)| Description
---|---|---|---
STATIC| MOTE| 0-255| Manual mode
STROBE| 0-25
ADDRESS| 001-512| DMX address settings
RUN MODE| MU| DMX mode
Slave| Master/slave mode
DMMR| Dimmer control mode
SENS| Auto detect DMX/DMMR mode
PERSONALTY| UNO (1 channel)| MAX channel mode settings
DOS (2 channel)
STD.P (4 channel)
SETTING| PASSCODE (

)| RESET| PASSCODE (... , )| Restore factory settings DIMMER| DISH| Dimmer settings DIMS DIM2 DIM1 OFF DMX ERROR| SAVE| DMX fail settings BLACK PWM RATE| 1200HZ| Refresh rate settings 2400HZ 4000HZ 6000HZ 25000HZ PERFORM| LIVE (low)| Fan speed settings POWER (high) STUDIO (auto) OISP KEY| ON| Display lock setting (passcode is UP . DOWN>.. . ) OFF DISP TIME| ON| Display backlight settings 10S 30S 2MIN N FO| FIXTURE HOURS| xxh| Fixture hours VERSION| V)00000000| Software version RDM| UID| OX02e5)00000ODI| Fixture 010 LABEL| Virtuoso COO Profile WW| Fixture model

DMX channel modes:
UNO (1 channel mode)

Channel Value Function
CH1 000-255 Master dimmer (0-100%)

DOS (2 channel mode)

Channel Channel Function
CH1 CH1 Master dimmer (0-100%)
CH2 CH2 Dimmer fine (0-100%)

STD.P (4 channel mode)

Channel Value Function
CH1 000-255 Master dimmer (0-100%)
CH2 000-255 Dimmer fine (0-100%)
CH3 Strobe
000-009 No function
010-099 Strobe (slow-fast)
100-109 No function
110-179 Lightning strobe
180-189 No function
190-255 Random strobe
CH4 Control
000-060 No function
061-070 Live
071-080 Studio
081-090 Power
091-100 No function
101-110 Dimmer off
111-120 Dimmer Dim4
121-150 No function
151-160 1200Hz
161-170 2400Hz
171-180 4000Hz
181-190 6000Hz
191-200 25000Hz
201-210 All reset
211-255 No function

DMX setup

Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output, see images below.        elumen8 Virtuoso
600 Profile WW Filter Frame Runner - Diagram 7Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

3-Pin: CABL185 – 2m CABL187 – 5m CABL188 – 10m
5-Pin: CABL10 – 2m CABL11 – 5m CABL12 – 10m

Notice:
Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Pin Confguration

3-Pin| 5-Pin
Pin 1- Ground
Pin 2 – Negative
Pin 3 – Positive
–| Pin 4 – N/C
–| Pin 5 – N/C

elumen8 Virtuoso 600 Profile WW Filter Frame Runner - Diagram
8 Line termination:
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin – Order ref: CABL90, 5-pin – Order ref: CABL89)

| Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.|
---|---|---

5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.elumen8
Virtuoso 600 Profile WW Filter Frame Runner - Diagram 11

Multiple fixture power linking

Power linking:
This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 8 fixtures @ 240V or 4 fixtures @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.
Please note: Caution should be used when power linking other fixtures to the Virtuoso 600 Profile as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.elumen8 Virtuoso 600 Profile WW
Filter Frame Runner - Diagram 12

WEEE notice

Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

elumen8 logowww.prolight.co.uk
Virtuoso 600 Profile WW User Manual

Documents / Resources

| elumen8 Virtuoso 600 Profile WW Filter Frame Runner [pdf] User Manual
ELUM136, Virtuoso 600 Profile WW Filter Frame Runner, Profile WW Filter Frame Runner, Filter Frame Runner, Frame Runner
---|---

Read User Manual Online (PDF format)