Brilliant 19847 2Light Heater with Exhaust Fan and CCT LED Light Instruction Manual
- June 13, 2024
- brilliant
Table of Contents
Brilliant 19847 2Light Heater with Exhaust Fan and CCT LED Light
Product Information
The HORIZON Model No.: 19847 is a 2Light Heater with Exhaust fan and CCT LED light. It is designed to provide heating, ventilation, and lighting in a single unit. The product must be installed by a qualified electrician in accordance with the latest AS/NZS 3000 electrical standards and relevant amendments.
Please read all instructions before commencing installation even if you are
familiar with this type of products. The HORIZON 2L Heater with exhaust fan
and LED light must be installed by qualified electrician. THIS FITTING MUST BE
INSTALLED BY A QUALIFIED ELECTRICAL CONTRACTOR in
accordance with the latest AS/NZS 3000 and relevant amendments
FOR YOUR SAFETY
- To prevent electrical shock, please ensure that power is DISCONNECTED before
- Be aware of the height of your Refer to ‘Working at Heights “ guide from your local or State Authorities.
- This product must be used only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to If you have questions, contact the supplier or local agent.
- All wiring must be carried out by a licensed electrician in accordance with all applicable national / local codes and standards. Also check with the local council regulations regarding installation of exhaust
- When cutting into the ceiling material, care must be taken to ensure you do not damage the existing ceiling structure, existing electrical wiring and other hidden
- The heater must be properly earthed/grounded.
- The lamps are extremely hot when in Do not touch the lamps with any part of your body when in use. Allow all lamps to cool sufficiently before touching or replacement.
- For the purpose of avoiding any fumes leaking into your bathroom, the duct for the heater must not be laid together with ducts for air-fuelled water heaters or other open-fire
- Power cable used for wiring must be appropriately rated . ( Preferred minimum 10A load).
- Any alterations or additions to building wiring must be completed by a licensed electrician or person authorised by legislation to work on the fixed wiring of any electrical installation
- The heat lamp is not suitable for continuous use for more than 30 Note: The LED light and the exhaust fan can be used continuously.
Keep this document handy for future reference.
Introduction
Please read these instructions carefully prior to installation and operation. Care should be taken when installing to prevent damage to the unit.
Before Installation
- A few minutes planning can make a big difference to the installation time and also to your satisfaction with the function of your
- Remove heat globes from the unit before installation to prevent
- Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists (at least 50mm clearance) and that there is sufficient height clearance (at least 220mm) from the Check if the electrical wiring can be routed from the wall switches to the mounting location.
- Ceiling insulation should be kept well clear away from the unit and all ducting
- The unit should not be installed directly above a shower or Refer to the ‘zones’ in bathroom in AS/NZS 3000.
- The unit must not be installed where it will be subject to direct
- This product is designed for installation in flat ceilings Don’t mount on a sloping ceiling or a vertical wall.
- The Infra-Red lamps are not designed to heat the entire room area, they provide instant heat to persons standing directly underneath Install your unit above the area where ‘drying off’ usually occurs.
- Your heater lamps are not designed for extended periods of operation, as this could cause overheating of the heater lamps and premature
- For exhaust fan to work efficiently an equivalent volume of air must enter the room being extracted. Generally, air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will operate poorly.
- Ensure there is at least 50mm clearance from joists and atleast 220mm height clearance from the unit.
- Check if the electrical wiring can be routed from the wallswitches to the mounting location.
Installation
- The recommended installation height is 2.4m. Remove the heatglobes from the unit before installation to prevent breakages.
- Ensure the area behind the intended location is clear of allcables, pipes, and joists. Use the provided card template to markthe cut out hole on the ceiling. The cut out hole size is 355mm x200mm.
- The unit can be mounted between joists using the inbuilt clipfasteners or against a joist using a screw through the flangeplate.
- Undo the front cover by detaching the 4 x springs.
- Remove the terminal cover on the rear of the base and connectwires as per the wiring diagram and instructions provided.
- If ducting is required, connect it after the unit is installedin the ceiling.
- Gently insert the unit into the cut out hole, ensuring to movethe side mounting clips inwards to avoid damaging the plasterboard.Tighten the screws for the clips to secure the unit in place.
- Hold the fascia against the body of the unit and the ceiling,then reattach the securing spring clips to hold the fascia inplace.
- Screw the two large heat lamps into the E27 lampholders,ensuring a firm connection without over tightening.
- If necessary, attach ducting to extract air to the outer wallusing 1.5m long flexible ducting, cable ties, and vent outlet grillprovided. Secure the flexible duct to the unit and the outer wallvent using cable ties.
- Check that all connections are secure.
- Turn the power ON.
- You can operate the unit using the wall switch.
Electrical wiring diagram
The wiring diagram is shown on Figure 7.
The unit requires ‘permanent active’. The fitting is fitted with a thermostat which will turn the motor ( FAN) ‘ON’ when the temperature exceeds 80C.
- Double pole disconnecting device (K) must be fitted in the circuit.
- Ensure the power is switched “OFF” at the mains before commencing
- Remove the cover on the back of the enclosure to access the
- Connect wires as per electrical wiring diagram Ensure connections are firm and secure.
- Replace the cover removed
Note: Red warning label must be permanently displayed on the cover of the unit WARNING: Permanent Active! Isolate at main switchboard before removing cover.
Operation
Your Brilliant Horizon Heater lamp uses Infrared heating lamps as a heat source. It also has an exhaust fan and an LED light.
- Heating: Switch the ‘Heat’ button ‘ON’ on the wall switch. The heat globes provide instantaneous heat from the moment they are switched ‘ON’.
- Exhaust Fan : Use the switch button ‘Fan’ to turn it ON and
- CCT LED Light: Operate the LED light independently from heat globes, using ‘Light’ On /Off switch
Change LED Light Colour Temperature: The colour temperature of CCT LED can be changed between 3000K, 4200K and 6000K. To change colour temperature, switch ON the light first, then switch the light ‘ OFF – ON – OFF – ON ’ within 3 seconds
Cleaning
- Switch off the power before commencing cleaning and wait until the globes cool down.
- Regularly wipe globes and front fascia with soft cloth soaked with water or neutral detergent if
- Clean the exhaust fan from dust and dirt with dry or wet cloth if
- Clean the exhaust ducting kit and ensure airways are clean and there are no obstructions at the exit from the wall.
Specifications
Model No | 19847/05 -White and 19847/11- Silver |
---|---|
Fascia colour | /05- White ; /11- Silver |
Voltage and power | 230V or 240V AC 50Hz 633W Max. |
Heat Lamps | 2 x 275W , 240V AC, R125, E27 |
Motor | 75W |
CCT LED
| 3000K, 900lm; 4200K, 1050lm; 6000K, 1000lm;
9W, Non dimmable
Air Movement| <300m3/h (at exit point from the unit)
Cut out hole size| 355mm x 200mm
Dimensions| Length 419mm x Width 244mm x Depth 210mm
Accessories
| Aluminium duct Φ125mm by 1.5m with fixing clamps and vent outlet grille-
included
Switch| 3-way gang switch, SAA approved- included
Noise| 45 dB
IP rating| IP X2 ; IPX4 LED globe only
PTC| 80C
Weight| 3kg
Installation in bathrooms
| Suitable for Installation in Zone 2 and Zone 3 in bathrooms as per AS/NZS 3000.
NOTE: Not suitable for installation in Zone 1 and Zone 0.
Minimal clearance distances:
Warranty:
Brilliant Lighting warrants this product against defects in manufacture and workmanship for a period of 3 years from date of purchase. For products used in non-domestic or commercial applications, Brilliant Lighting warranties this product for a period of 3 months from date of purchase. This warranty is only valid for products installed by a qualified electrical contractor and operated within the guidelines specified by Brilliant Lighting, and within the correct operating voltage ranges as stated on the product’s rating label.
Warranty does not include damage or loss arising from incorrect installation, operation or maintenance of this product, damage caused through modification, incorrect installation, service by unqualified or unauthorised personnel or lack of regular maintenance and cleaning. Proof of installation by qualified personnel may be required, eg. Electrical Safety Certificate. Proof of purchase must be supplied with all warranty claims.
This warranty is provided in addition to any other rights and remedies of the customer under any law. In applications not intended for household, personal or domestic use, liability is limited to replacement or reimbursement of product only.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure.
Any claim under this warranty must be made within the specified warranty period from date of purchase of this product. To make a claim under the warranty, take the product (with proof of purchase – receipt or similar) to the store where you purchased the product or contact Brilliant Lighting at the address below.
This warranty is given by:
Brilliant Lighting (Aust)Pty. Ltd. ABN 37 006 203 694
- 956 Stud Road Rowville, VIC 3178
- Phone: 03 9765 2555
- Email: info@brilliantlighting.com.au MADE IN CHINA
Read User Manual Online (PDF format)