GENERAL ARUNA 301S RF Wireless Room Thermostats User Manual
- June 13, 2024
- GENERAL
Table of Contents
ARUNA 301S RF Wireless Room Thermostats
Product Information
The ARUNA 301S RF is a wireless room thermostat that allows
users to adjust the temperature for more comfortable and economic
heating/cooling. It offers daily and weekly programming options,
different mode options (comfort, economy, holiday), heating
calibration, ON/OFF control, wireless connection, heating/cooling
option, TPI algorithm for precise temperature measurement.
The ARUNA 301S RF comes with the following equipment:
- ARUNA 301S RF Room Thermostat
- Holder
- Alkaline Battery (AAA)
- Receiver
- Dowels and Screws
Technical Data for the Room Thermostat:
- Dimensions: 85mm / 125mm / 20mm
- Operating Current
- Temperature Measurement Accuracy
- Operating Temperature Range
- Battery Life
- Storage Temperature
Receiver Dimensions:
- Operating Current
- Relay NO Switching Current
- Storage Temperature
Product Usage Instructions
Button Functions on Room Thermostat:
- On/Off Button
- Heating & Cooling Option
- Weekly Program Button
- Temperature Adjustment Button (To Decrease)
- Temperature Adjustment Button (To Increase)
- Mode Button
Product Display Layout:
The Receiver has the following indicators:
-
Hour Indicator
-
Room Temperature
-
Economy Mode
-
Comfort Mode
-
Holiday Mode
-
Weekly Program Mode
-
Day Indicator
-
Battery Indicator
-
Set Temperature
-
Heating Indicator:
-
If the Heating Indicator is blinking, the heating unit is
working. -
If the Heating Indicator is steady, the heating unit is not
working.
-
-
Cooling Indicator:
-
If the Cooling Indicator is blinking, the cooling unit is
working. -
If the Cooling Indicator is steady, the cooling unit is not
working.
-
Receiver Button Functions:
-
Manual Operation Button: Deactivates the Receiver and allows
manual use of the heating/cooling unit. -
Pairing Button: Allows pairing the Receiver with the Room
Thermostat. -
Receiver LED Light
-
Receiver Power Cable Input
-
Heating/Cooling Unit Connection Cable Input
The Receiver LED can have the following descriptions:
- Steady Red
- Blinking Green
- Steady Green
- 3 Short Orange Blinking
- Steady Orange
- 3 Short Green Blinking
- Blinking Orange
- Blinking Red
Note: The Receiver and heating/cooling unit
should not have physical contact and should be protected against
materials such as liquid and dust. The distance between the Room
Thermostat and the Receiver should not exceed 20 meters or 2
floors. The Receiver must be installed at least 50 cm away from the
heating/cooling unit.
Receiver Setup:
-
1. First, shut down your heating/cooling unit and disconnect its
power source.
-
As shown in the connection diagram, connect one end of the
heating/cooling unit to the appropriate input on the Receiver.
DIGITAL ROOM THERMOSTAT generallife.com.tr
ENGLISH
ARUNA 301S RF USER MANUAL
GENERAL SPECIFICATIONS
ARUNA 301S RF is a wireless room thermostat. The user can get more comfortable
and economic heating/cooling by adjusting the room thermostat with the required
temperature.
Daily and Weekly Programming
Different Mode Options (Comfort, Economy, Holiday)
Heating Calibration
ON/OFF Control
Wireless Connection
Heating/Cooling Option
TPI Algorithm
Precise Temperature Measurement
ARUNA 301S RF and EQUIPMENTS ARUNA 301S RF Room Thermostat
Holder
Alkaline Battery
AAA AAA
Receiver
Dowels and Screws
TECHNICAL DATA Room Thermostat
Dimensions Operating Current Temperature Measurement Accuracy Operating
Temperature Range Battery Life Operating Temperature Storage Temperature
85mm / 125mm / 20mm
3V DC (2 x AAA alkaline battery) 0.1oC (5oC) (30oC)
1 Year (2 x AAA) (-10oC) (+50oC) (-20oC) (+60oC)
Receiver Dimensions Operating Current Relay NO Switching Current
Storage Temperature
ROOM THERMOSTAT Button Functions
90mm / 90mm / 25mm 230V AC 7A (240VAC Resistive Load) 10A (120VAC Resistive Load) (-20oC) (+60oC)
1
4
2
5
3
6
1
On/Off Button
2
Heating & Cooling Option
3
Weekly Program Button
4
Temperature Adjustment Button (To Decrease)
5
Temperature Adjustment Button (To Increase)
6
Mode Button
1
Product Display Layout
1
7
8
2
3
9
4 5
10 11
6
1 2 3 4 5 6 7 8 9
10
11
RECEIVER
1 2 3
Hour Indicator Room Temperature Economy Mode Comfort Mode Holiday Mode Weekly
Program Mode Day Indicator Battery Indicator Set Temperature Heating Indicator
– If the Heating Indicator is blinking, the heating unit is working. – If the
Heating Indicator is steady, the heating unit is not working. Cooling
Indicator – If the Cooling Indicator is blinking, the cooling unit is working.
– If the Cooling Indicator is steady, the cooling unit is not working.
1-Manual Operation Button: Deactivates the Receiver and allows you to use
heating/cooling unit manually. 2-Pairing Button: Allows pairing the Receiver
with the Room Thermostat. 3-Receiver LED Light 4-Receiver Power Cable Input
5-Heating/Cooling Unit Connection Cable Input
4
5
RECEIVER LED DESCRIPTIONS
Steady Red
Blinking Green Steady Green
3 Short Orange Blinking
Steady Orange 3 Short Green Blinking
Blinking Orange Blinking Red
Receiver has power but Receiver and Room Thermostat are not paired. Waiting for pairing signal from the Room Thermostat. Receiver and Room Thermostat are paired. Heating/cooling unit is not operating. Operate the heating/cooling unit signal has reached to the Receiver. Heating/cooling unit is operating. Shut the heating/cooling unit down signal has reached to the Receiver. Heating/Cooling unit operates in manual mode. Receiver did not get any signal from the Room Thermostat for 22 minutes or longer. Heating/cooling unit has shut down.
ROOM THERMOSTAT PLACEMENT Room Thermostat needs to be placed in the room which is used most frequently. For instance; living room or lounge. Placing the Room Thermostat in a spot that have air circulation like entrance of a room or side of window should be avoided. Also anywhere close to heating/cooling units such as radiator, stove and spots which get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot.
min. 20 cm
2
BATTERY PLACEMENT
Press the screwdriver forward from the space at the bottom of the Room Thermostat, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Align the front part of your Room Thermostat with corresponding slot on the back, and then push gently until the thermostat snaps into place. Low Battery Warning: When the ” ” icon appears on the screen, it means “low battery warning”. It is recommended to replace the batteries when this warning appears. Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries.
RECEIVER PLACEMENT
The important things to note for the Receiver placement are avoiding physical contact between the Receiver and heating/cooling unit, and protecting it against materials such as liquid, dust etc.
The devices should be placed in order to minimize the damage to the received
and transmitted signals by paying attention to the following points; The
devices should not be mounted on metal surfaces. The devices should not be
installed close to electrical cables and electronic
equipment such as computers and television units. The devices should not be
installed near large metal structures or other building
materials using fine metal meshes such as special glass or special concrete.
Distance between the Room Thermostat and the Receiver should not exceed 20
meters or 2 floors. Receiver must be installed at least 50 cm away from the
heating/cooling unit.
RECEIVER SETUP First, shut down your heating/cooling unit and your
heating/cooling unit’s power
source with all electrical current (fuse, socket etc.) As shown in the
connection diagram, connect one end of the heating/cooling unit
connection cable to the COM and the other to the NO input of the Receiver.
Connect the other ends of the cable -which you connected to the Receiver- to
room thermostat connection terminal as shown in your heating/cooling unit’s
user manual. You must first connect the Receiver power cable to the Receiver
and then to the fuse which the heating/cooling unit is connected. After
completing the cable connection process, firstly turn on your fuse and then
your heating/cooling unit. By pressing the Receiver’s manual usage button for
2 seconds, you should see the Orange Light blinking on the Receiver. In this
way, after making sure that the heating/cooling unit is operating, press the
same button again for 2 seconds and see that the Orange LED turns off. Set up
the Room Thermostat to pair the Receiver with the Room Thermostat.
RECEIVER WIRING DIAGRAM
COM NO
AC (230V)
HEATING/COOLING UNIT
Warning! Operations within the heating / cooling unit or the electrical
installation must be carried out by professionally qualified persons.
3
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER Primarily press the sync button
of the Receiver for 2 seconds and see blinking
green light of the Receiver. While your device is turned off, press and hold
the “On/Off” button for 3 seconds. Press the button until the ” ” menu
appears. Press the “Up” or “Down” button of your Room Thermostat while the LED
is
flashing green. If the pairing is successful, the green flashing LED on the
Receiver will be steady. Receiver and Room Thermostat have been paired to each
other.
ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly sensitive.
You may need to calibrate your Room Thermostat if you would like to get the same
temperature values with other thermometers in your living space.
While your device is turned off, press and hold the “On/Off” button for 3 seconds.
Press the “On/Off” button until the ”
” menu appears. In order to see the
desired temperature, set the temperature difference by pressing the
“Temperature Adjustment Buttons”. This value can be arranged between “-8° C”
and “+8° C”.
In order to save the settings and exit, press the “On/Off” button until the device
turns off.
Note: Recommended temperature calibration is “0.0°C”.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting and heating/cooling
modes to factory setting. In order to reset your Room Thermostat to factory setting:
While your device is turned off, press and hold the “On/Off” button for 3 seconds.
Press the “On/Off” button until the ” ” menu appears.
While in the ”
” menu, select the ” ” option by using the “Up” or “Down”
buttons and press the “On/Off” button.
Your device will be turned off and reset to factory settings.
DAY AND HOUR SETTINGS While your Room Thermostat is on, keep pressing the
“Weekly Program” button
for 3 seconds. At the first screen that appears, hour part will be blinking.
You may set the time
with the “Up” and “Down” buttons. After setting the time, the “Heating &
Cooling Option” button needs to be pressed
once. For minute setting, minute part will be blinking. You may set the minute
with the “Up” and “Down” buttons. After setting the minute, the “Heating &
Cooling Option” button needs to be pressed once to set the day of the week.
Monday has set as the first day of the week and indicated with number “1”.
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday,
4Thursday, 5-Friday, 6-Saturday and 7-Sunday When setting is done, you may
exit by pressing the “Weekly Program” button for 3 seconds.
MODE SETTING
MODES
PRESET MODES
WEEKLY PROGRAM
MODE
MANUAL MODE
Comfort Mode
Economy Mode
Holiday Mode
Your Room Thermostat has 5 different modes. 3 of them (Comfort, Economy and
Holiday Mode) are preset modes. Other modes are manual mode and weekly program
mode. In preset modes, temperature values are based on user’s choices which
have been set in the beginning. Manual mode allows the Room Thermostat to
operate within the temperature which is required and set directly by user.
Weekly Program mode continues to work according to the weekly schedule
determined by the user. In order to change the temperature values of preset
modes: Press and hold the “Mode” button for 3 seconds while your Room
Thermostat is
on. Comfort Mode temperature value will appear. You may adjust the temperature
value of Comfort Mode by pressing the “Up” and “Down” buttons. When setting is
done, you may adjust the temperature value of Economy Mode
with the “Up” and “Down” buttons by pressing the “Mode” button again. You may
exit the setting screen by pressing the “Mode” button 3 seconds. In order to
change the manual mode temperature, press the “Up” or “Down” button
while in the main screen. The Room Thermostat will switch to Manual Mode once
pressed the “Up” or “Down” button. You may press the “Mode” button to switch
to the other modes.
4
WEEKLY PROGRAM You may set the operating schedule of your Room Thermostat with
weekly program mode. 7 different temperature values can be set for each day in
weekly programming. These values can be set in temperature adjustment screens
” P0-P6”. In order to set the weekly schedule, press and hold the “Weekly
Program” button
for 3 seconds while your Room Thermostat is on. The “Hour, Minute and Day”
setting will appear. Press the “Heating & Cooling Option” button until the
“Weekly Program” menu (P0) appears. Days of the week will be blinking on the
screen. You can initiate the weekly program setting if you wish to set the
same schedule for every day of the week. Press the “Up” button once if you
wish to set the same schedule for the weekdays. First five days of week will
be blinking on the screen. Press the “Up” button once more if you wish to set
the same schedule only for the weekend. Last two days of the week will be
blinking on the screen. Press the “Up” button one more time if you wish to set
the same schedule for every day of the week. 1st day of the week will be
blinking on the screen. You can switch between the days by pressing the “Up”
button. Press the “Down” button in order to switch to the previous day. Press
the “Weekly Program” button once to set a schedule. “P0” will be blinking on
the screen. Set the temperature value of “P0” by pressing the “Weekly Program”
button once more. The hour setting of “P0” cannot be changed since it’s
factory setting. Press the “Weekly Program” button again. Day indicator will
be blinking. If you will not change the day, press the “Weekly Program” button
again and switch to the “P1” setting by pressing the “Up” button. First, hour
setting will appear on the screen. Once you complete the hour setting, adjust
the minute setting by pressing the “Weekly Program” button. After the minute
setting, press the “Weekly Program” button to set the temperature value.
Follow the same steps for other schedule settings. Once all changes made,
press and hold the “Weekly Program” button for 3 seconds to save. Note: In
order to check the weekly schedule which has been set without making any
changes, press the “Weekly Program” button once while your Room Thermostat is
on. Press the “Up” and “Down” buttons to see the days, press the “Mode” button
to see the settings between “P0-P6”.
TPI ROOM THERMOSTAT WORKING LOGIC Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI technology predict when the temperature of your home will rise above or below the set temperature and turn the heating / cooling unit on and off accordingly. This ensures that your home stays at the temperature you set without maximum deviations up and down. What is TPI? TPI technology is designed to ensure that you get the best possible energy efficiency from your heating / cooling system. It measures and applies the best possible timings to deliver and maintain your home at the set temperature level. How does TPI work? Thanks to the advanced artificial intelligence technology found in the software, it adapts to the temperature change of the environment in which it is located. By creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how to maintain this temperature. In this way, it provides minimum energy consumption by calculating how long your heating / cooling unit should work for. What is the difference? In non-TPI room thermostats, the heating / cooling unit works and stops continuously until it exceeds the set temperature value. If the set temperature drops below a certain amount, the heating / cooling unit will work again. This creates greater temperature fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide higher savings and comfort compared to On/Off room thermostats with the advantages it has.
Heating Mode Your room thermostat takes the average room temperature of last 40 seconds as basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
TEMPERATURE (ºC)
Desired Temperature
TPI Room Thermostat
30
23
5
Time
5
Cooling Mode Your room thermostat takes the average room temperature of last 40 seconds as basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC
TEMPERATURE (ºC)
Desired Temperature
TPI Room Thermostat
30
23
5
Time
Your Room Thermostat sends the last status signal to the Receiver every 10 minutes. Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that the connection is broken and stops the heating/cooling operation for safety reasons. Likewise, in cases where the electricity comes back after a power failure, the Receiver does not operate the heating/cooling unit until ‘operate’ signal reaches from the Room Thermostat. However, in this case, if the Room Thermostat continues to operate normally, it will continue to work properly without any need for intervention since it sends a status signal to the Receiver every 10 minutes.
WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT If the placement of the TPI Room
Thermostats is changed, the learning process
will restart. The learning process should be considered as 7 days. If the TPI
Room Thermostats are de-energized (battery replacement), the learning
process will restart. The learning process should be considered as 7 days.
FREQUENTLY ASKED QUESTIONS Is my Room Thermostat compatible with my heating/cooling unit? If your heating/cooling unit has On-Off connections, your Room Thermostat is compatible. You can find information about your heating/cooling unit from your heating/cooling unit operating manual or from your heating/cooling unit service. How will I connect my heating/cooling unit with my Receiver? We recommend that the connection between the Receiver and heating/cooling unit should be made by professionally qualified persons. 2×0.75 mm cable is sufficient for the Receiver heating/cooling unit connection. Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of your heating/cooling unit. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Receiver as shown in the “RECEIVER WIRING DIAGRAM” section. The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
ISIPARK Ç VE DI TC. N. ISITMA SSTEMLER OTO. SAN.A.. which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarniç – Gaziemir –
ZMR TÜRKYE confirms and declares that the product marked with CE and its
specifications below is covered by the provisions of the mentioned directive.
Brand
: GENERAL Life
Product Name : ARUNA 301S RF
Product Type : Digital Room Thermostat
Compatible Directives:
Radio and Telecommunications Terminal Equipment Regulation 2014/53/EU
(R&TTE/RED EN 301 489-1 V2.1.1:2017,
EN 300 220-1 V3.1.1:2017, EN 301 489-3 V2.1.1:2017,
EN 300 220-2 V3.1.1:2017, EN 62479: 2010)
Electromagnetic Compatibility Regulation 2014/30/EU
(EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007)
Low Voltage Directive 2014/35/EU
(LVD EN 60730-2-9:2010, EN 60730-1:2011)
Additional Information: The mentioned product can be used with heating/cooling
units with On-Off output and compliance with the directives only covers the
product. ISIPARK is not responsible for the entire system’s compliance with the
directives. This statement is not valid if changes are made to the product without
our approval.
6
WARRANTY CONDITIONS 1-The warranty period starts from the invoice date and
warranted against manufacturing defects for 5 years. 2-Devices and apparatus
are delivered to the customer in working condition in our company. On-site
commissioning is subject to a service fee. 3-The repair of the devices and
apparatus covered by the warranty is carried out in our company factory and
should send by contracted transportation company. In onsite services, the
transportation and accommodation expenses of the service personnel belong to
the customer. The shift fee during transportation is added to the service fee
and collected in advance. 4-The maintenance of devices and apparatus is done
in our company. For the maintenance of the devices and apparatus, the round
travel fares belong to the customer. 5-In case of malfunctioning of the
devices and apparatus whose warranty period continues, it is tested in our
company whether the malfunction is caused by a customer or manufacturer fault,
and it is reported with a report issued by our company. 6-In case of detection
of manufacturer-induced errors of devices and apparatus whose warranty period
continues, the customer can request a replacement or repair of the devices and
apparatus at full expense by the manufacturer, unless it’s higher than the
product’s price. 7-In the event that the faults of the devices and apparatus
whose warranty period continues are determined as caused by the customer, all
expenses would belong to the customer. 8-Customers should be aware of damages
(if there is any) of product and warn manufacturer since the day warranty
duration starts. If customer do not warn manufacturer with knowledge of
damage, customer lose the rights of article 6. 9-Malfunctions resulting from
the use of devices and apparatus contrary to the matters stated in the User
Manual are not covered by the warranty. 10-Devices and their apparatus are out
of warranty if they are beaten, broken or scratched by the customer.
11-Damages resulting from the use of devices and apparatus belonging to other
brands and models without the approval of the manufacturer are not covered by
the warranty. 12-Battery leakage and errors due to rust, oxidation and liquid
contact by working in acidic / humid environments are not covered by the
warranty. 13-When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that will occur are out
of warranty. 14-Damages that may occur during the transportation of devices
and apparatus are not covered by the warranty. Customers can take
transportation insurance. 15-Damages caused by mains voltage / faulty
electrical installation are not covered by the warranty. 16-Devices and
apparatuses are out of warranty for malfunctions caused by force majeure such
as fire, flood, and earthquake etc. 17-All of the devices and apparatuses,
including all their parts, are under the warranty of our company. 18-In case
of malfunction of the devices and apparatuses within the warranty period, the
time spent during repair period is added to the warranty period. The repair
period of the product cannot exceed 20 working days. This period starts from
the date of notification to the service station of the malfunction related to
the product or, in the absence of a service station, to the seller, dealer,
agency, representative, importer or manufacturer of the product. Consumer can
report the problem by; phone, fax, e-mail, registered and reply paid letter or
a similar way. However, in case of a conflict, responsibility of prove is
belong to the customer. If the malfunction of the product is not repaired
within 20 working days, the manufacturer-producer or importer; has to allocate
another product with similar features to the use of the consumer until the
repair of the product is completed, 19-Although the consumer uses his/her
repair rights, -If the product breaks down for 4 times in a year or 6 times in
warranty duration and these problems effects main purpose of the product.
(Starting from delivery time during warranty.) -Exceeding the maximum time
required for repair, -In the event that the service station is not available,
if it is determined that the repair of the defect is not possible with the
report prepared (in order) by one of the seller, dealer, agency,
representative, importer or manufacturer, a refund or a price discount at the
rate of defect can be requested. 20-The customer can make complaints and
appeals to consumer courts or consumer arbitration committees. 21-The warranty
document must be kept by the customer during the warranty period. If the
document is lost, a second document will not be issued. In case of loss,
repair and replacement of devices and apparatus will be made for a fee.
7
WARRANTY CERTIFICATE
Manufacturer Title: ISIPARK Ç DI TC. A.. Adsress: Fatih Mah. 1188 Sk. No:13/A
Sarniç Gaziemir zmir-TÜRKYE Tel: +90 (232) 457 99 50 Fax: +90 (232) 457 91 22
E-Mail: generallife@generallife.com.tr Authorised Signatory: Company Stamp:
Product Type: Digital Room Thermostat Brand: GENERAL Life Model: ARUNA 301S RF
Guarantee Period: 5 Years Max. Time to Repair: 20 Days Banderole and Serial
Number:
Vendor Title:
Address:
Tel:
Fax:
E-Mail:
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
Product Type: Digital Room Thermostat Brand: GENERAL Life Model: ARUNA 301S RF
STAMP
Isipark reserves the rights of changing product specifications and user
manuals. *For all changes,you may visit generallife.com.tr
8
V-01.2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>