Aprilaire AUV24V Residential UVC Coil Cleaner Instruction Manual

June 13, 2024
Aprilaire

UVC
UV24V Residential UVC Coil Cleaner
Instruction Manual INSTRUCTION MANUAL
Model AUV24V
Residential UVC Coil Cleaner
Installed By:……………………………………..
Installer Phone:……………………………………
Date Installed:………………………………………

ALL RIGHTS RESERVED. AUGUST 2022 V.1 (PHOTOS ILLUSTRATING PRODUCTS ARE NON CONTRACTUAL)
**** NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP

**** IMPORTANT SAFETY INSTRUCTIONS

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
READ AND SAVE THESE INSTRUCTIONS

  1. Installation and servicing of UV units or systems (in an air conditioning system or not) can be hazardous. Only trained and qualified service personnel should install, repair or service equipment.

  2. Untrained personnel can perform basic maintenance functions such as replacing the lamp. All other operations should be performed by trained service personnel.
    CAUTION: UNIT IS NOT A TOY. KEEP AWAY FROM UNSUPERVISED CHILDREN. DO NOT LEAVE CHILDREN UNATTENDED WITH THE UNIT.

  3. DO NOT hang onto the UV unit or system.

  4. When installing or servicing an overhead UV unit or system, be careful not to fall off the stepladder. Furthermore, make sure the UV unit or system latches are always in place to prevent falling parts.

  5. Units that are obviously damaged must not be operated.

  6. CAUTION: When working on the UV unit or system, observe precautions on the literature, tags and labels attached to the UV unit or system, and all other safety precautions considered as best practices in the HVAC industry, if applicable.

  7. When applicable, local regulation may comprise more restrictive installation and/or certification requirements. The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own

  8. Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

  9. All UV units or systems contain a UV-C source. Damage to the housing or unintended use of the UV unit or system may result in harmful UV-C leaks. UV-C may, even in little doses, cause harm to the eyes and skin.

  10. Never expose eyes or skin to an operating UV lamp.Therefore, before installing or performing maintenance on the UV unit or system, TURN OFF AND DISCONNECT the UV unit or system from all power sources (there may be more than one switch to disconnect) and also disconnect the HVAC system, is applicable.
    **WARNING**
    High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation.

  11. UV light can cause color changes or structural degradation of plastics, rubber, and other non-metallic materials used in the HVAC system.
    • Install lamp in a location that prevents exposure to these materials or shield them with aluminum tape or sheet metal.
    • Do not install within 6ft of flex duct.
    • Do not install near the HVAC air filter.

  12. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

  13. Just like conventional fluorescent lamps, UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use in the same way as any other fluorescent lamps. Contact and follow the specific instructions of your local and national authorities.

  14. Use only specified AprilAire branded replacement UV lamps for your UV unit or system. Use of any other lamps will void your warranty and can result in damage to the UV unit or system.

  15. This AprilAire UV unit is not waterproof. DO NOT INSTALL OUTDOORS OR IN WET LOCATION.

  16. The use of a UV unit or system is a supplement to and not a substitute for standard infection control practices; users must continue to follow all current infection control practices, including those related to the cleaning and disinfection of environmental surfaces.

  17. Check for existing holes in duct and repair prior to installation.

  18. Always TURN OFF AND DISCONNECT the HVAC unit / system before attempting any service

  19. Ensure ANY drilled holes and fasteners do not damage the AC EVAP Coil, Lines or any other components in the area.

For any inquiries, issues or concerns on a UV unit or system, contact:
AprilAire Customer Support: aprilaire.com/contact or Call: 800.334.6011
SAVE THESE INSTRUCTIONS

ABOUT THE PRODUCT

HOW IT WORKS
When a bio-film (a coating of microbial growth) covers a coil, it acts as an adhesive, attracting dirt and coating the fins of the coil.
This results in an odor emanating from the equipment and a loss in energy efficiency as the equipment must work harder to provide the same air temperature. Installed on the air conditioning’s evaporator coil, the AUV24V keeps the system running at top  fficiency, saving you electricity, and preventing the coil from becoming a source of bad air quality and bad odor.
The UVC (254 nm) wavelengths produced by AprilAire UV units and systems are the same as the ultraviolets produced by the Sun. The UVC attacks the micro- organisms on a molecular level deactivating the contaminants. Unlike conventional UVC Lamps on the market, AprilAire UV units and systems use a process designed to deliver the maximum UV dosage to the moving airstream or surface.
CAUTION: Never expose eyes or skin to an operating UVC Lamp.

OPTIONAL ACCESSORIES AND KIT

  • Step Down Transformer (AC) to convert a regular outlet (120 VAC) to 24 VAC if the necessary power (20VA minimum) is not available from your HVAC System: 120 VAC to 24 VAC 40VA AprilAire Part Number: 8029

For instruction manuals or information about your optional accessories and/or kits, please contact: AprilAire Customer
Support: Aprilaire.com / contact or Call: 800-334-6011

SETUP & INSTALLATION: UV-C LAMP

WHAT YOU WILL NEED:

  • Utility knife
  • Marker
  • 3/8” fluted drill bit
  • Phillips # 2 screwdriver
  • Power Drill
  • ¼” Nut Driver
  • 1” stepped metal drill bit
  • Measuring Tape
  • 18 gauge wiring and connectors

WHAT’S INCLUDED:

  • Lamp Housing Assembly
  • UVC Lamp
  • Ballast
  • UV caution decal
  • Maintenance decal
  • Pair of cotton gloves
  • 2 self-tap Phillips screws
  • 2 short Phillips screws
  • 1 long Philips screw
  • 6 hex head sheet metal screws
  • Lamp retainer ring
  • Viewing port insert

CAUTION
Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Tighten all fasteners by hand taking care not to leave loose or overtighten. Confirm you have access to the necessary power source for the product requirements (see unit or system label).
STEP BY STEP INSTALLATION GUIDE – EXTERIOR BRACKET METHOD

  1. IMPORTANT WARNINGS PRIOR TO BEGINING INSTALLATION
    a. Never look at UVC Lamp while energized
    b. Disconnect and turn off power to all HVAC equipment prior to installation
    c. Ensure adequately clear space exists behind mounting points, selected lamp location, screws, and potential overshooting of drill bits when puncturing sheet metal.
    d. Do not over tighten screws as they may lose their holding power and lead to improper installation

  2. Clear working area and unpack all included equipment from box; set aside on clear working space. Lamp should remain in cardboard sleeve for protection until installed into bracket.

  3. Mark appropriate lamp installation position relative to the evaporator coil. Please reference image 90-2737 for UVC lamp placement in relation to the coil. The location should also be centered on the ductwork for even light distribution. Ensure enough free space for the main mounting bracket and power cord is present on exterior of sheet metal.
    a. When installing the UV lamp in an air handler, position a single lamp off- center to avoid interference with the blower as shown in Option 1. If installing on the front face of the unit, install (2) UV lamps on either side of the A-coil as shown in Option 2.

  4. Locate appropriate ballast installation position relative to lamp installation position. Ensure this position will be within reach of the ballasts power cord once installed. Confirm access to 24V AC power is available to be connected after ballast installation (if unavailable, a separately sold AC transformer is recommended). Mark screw hole mounting points for future reference.

  5. Mark appropriate UV shielded view port position relative to lamp location. The view port should be placed 3-12 inches away from light source with direct line of sight to allow for monitoring of lamp status when unit is powered on. Only visible spectrum blue light will pass through this view port, while the damaging UV light is completely blocked.

  6.  Drill a 1-inch hole at the marked lamp installation location using the stepped drill bit. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other equipment when puncturing sheet metal.

  7. Mount the back plate to the ductwork using included self-tapping sheet metal screws. The flat side of the bracket should contact the ductwork. Ensure the center lamp hole aligns with the newly drilled hole to allow for lamp installation. Orient bracket housing into desired final position and secure with sheet metal screws in 2 mounting through holes.

  8. Mount UVC Lamp in housing assembly. Start by lightly threading 2 included Philips screws into the lamp retainer mounting points, allow enough space for retainer ring plate to slide under screw head. Carefully cut open lamp packaging and put on protective gloves. Insert the non-power terminal end of the lamp though the center lamp hole until contact is made with the shaft flange. Align retainer ring mounting slot with previously installed screws and compress the lamps shaft shoulder between the retainer ring and mounting plate. Twist the retainer ring so that the screw shafts contact the opposite end of the mounting slots. Tighten down screws by hand.
    a. ONLY handle lamp with clean gloves. If lamps surface becomes contaminated, clean with isopropyl alcohol.

  9. Mount ballast at previously marked position. Align the ballast into desired final position before securing with sheet metal screws at mounting points. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other equipment when puncturing sheet metal.

  10. Apply included informative and warning stickers in a clearly visible location near the lamp and ballast.

  11. Drill a 3/8” hole for the view port using a fluted drill bit at the previously marked location. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other equipment when puncturing sheet metal. Firmly press included plastic viewport piece into drilled hole such that the flat side will be on the exterior of the sheet metal and the flange is completely contacting the ductwork exterior. Pressing too hard may result in damage to the view port.

  12. Wire 24VAC power to the ballast
    a. If using 24V from furnace control board
    i. Make sure that the HVAC equipment can supply a minimum of 20VA
    ii. Connect the two black wires to the R and C terminals on HVAC Equipment
    b. If using a separate 24V transformer
    i. Install transformer per manufacturers specifications
    ii. Connect 24V to the two black wires at the transformers output terminals

  13. Connect the ballasts right angled 4-hole plug to the UVC Lamps 4-pronged terminal. The connection is keyed and may require the power cord fitting be rotated 90 degrees to properly mate with the lamp power terminals. Once connected, the cord may be rotated into the desired final position without disassembling the unit.

  14. Restore power to all HVAC equipment and allow 30 seconds for equipment to reach steady state before checking LED indicator and view port for equipment status
    a. If UVC light can be seen escaping duct work immediately turn off power and seal discovered light paths with UV resistant sealer
    b. If LED indicator is solid and view port is illuminated, equipment is functioning properly
    c. If LED indicator is flashing, proceed to trouble shooting section for error code reference

For any inquiries, issues or concerns on a UV unit or system, contact:
AprilAire Customer Support: aprilaire.com/contact or Call: 800.334.6011
STEP BY STEP INSTALLATION GUIDE – INTERNAL MAGNET METHOD

  1. IMPORTANT WARNINGS PRIOR TO BEGINING INSTALLATION
    a. Never look at UVC Lamp while energized
    b. Disconnect and turn off power to all HVAC equipment prior to installation
    c. Ensure adequately clear space exists behind mounting points, selected lamp location, screws, and potential overshooting of drill bits when puncturing sheet metal.
    d. Do not over tighten screws as they may lose their holding power and lead to improper installation

  2. Clear working area and unpack all included equipment from box; set aside on clear working space. Lamp should remain in cardboard sleeve for protection until installed into bracket.

  3. Gain access to the ductwork interior located around the evaporator coil. If an existing entry way does not exist, a new entryway may need to be created prior to installation. Ensure adequately clear space exists behind any drilling location to prevent potentially damaging other equipment when puncturing sheet metal.

  4. Mark appropriate lamp installation position relative to the evaporator coil. Please reference image 90-2737 for UVC lamp placement in relation to the coil. The location should also be centered on the ductwork for even light distribution. Ensure there will be enough free space for the bracket and magnet once installed.

  5. Locate appropriate ballast installation position relative to the marked lamp installation position. Ensure this position will be within reach of the ballasts power cord once both are installed. Confirm access to 24V AC power is available to be connected after ballast installation (if unavailable, a separately sold AC transformer is recommended). Mark screw hole mounting points for future reference.

  6. Mark appropriate UV shielded view port position relative to lamp location. The view port should be placed 3-12 inches away from light source with direct line of sight to allow for monitoring of lamp status when unit is powered on. Only visible spectrum blue light will pass through this view port, while the damaging UV light is completely blocked.

  7. Mount ballast at previously marked position. Align the ballast into desired final position before securing with sheet metal screws at mounting points. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other  equipment when puncturing sheet metal.

  8. Apply included informative and warning stickers in a clearly visible location near the lamp and ballast.

  9. Cut sheet metal to allow power cord access to the product once installed. This can be achieved by drilling a 1” hole near the final lamp position or by notching the access panel. If drilling a hole, use the stepped drill bit at the previously marked location. If notching access panel, cut sheet metal with shears, and dry fit the power cord into the notch. Ensure no sharp edges will contact the power cords insulation. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other equipment when puncturing sheet metal.

  10. Add offset bracket to main bracket, secure pieces with the two included self-tapping Philips screws.

  11. Attached the magnet to the offset bracket using the included long Philips screw and nut. The Philips head should be on the exterior of the assembly, opposite the base plate.

  12. Mount UVC Lamp in housing assembly. Start by lightly threading 2 included Philips screws into the lamp retainer mounting points, allow enough space for retainer ring plate to slide under screw head. Carefully cut open lamp packaging and put on protective gloves. Insert lamp through center lamp hole until contact is made with the shaft shoulder near the lamps power terminals. Align retainer ring mounting slot with previously installed screws and compress the lamps shaft shoulder between the retainer ring and mounting plate. Twist the retainer ring so that the screw shafts contact the opposite end of the mounting slots. Tighten down screws by hand.
    a. ONLY handle lamp with clean gloves. If lamps surface becomes contaminated, clean with isopropyl alcohol.

  13. Carefully position the assembly inside the duct work, allow magnet to fully adhere to sheet metal before releasing grip. Depending on space requirements, you may need to follow step 15 first to allow unit to be plugged in.

  14. Connect the ballasts right angled 4-hole plug to the UVC Lamps 4-pronged terminal. The connection is keyed and may require the power cord fitting be rotated 90 degrees to properly mate with the lamp power terminals. Once connected, the cord may be rotated into the desired final position without disassembling the unit.

  15. Seal around the power cord using UVC resistant sealant, be careful not to damage cord insulation on sharp metal edges.

  16. Drill 3/8” hole for view port using fluted drill bit. Ensure adequately clear space exists behind drilling location to prevent potentially damaging other equipment when puncturing sheet metal. Firmly press included plastic viewport piece into drilled hole such that the flat side will be on the exterior of the sheet metal and the flange is completely contacting the ductwork exterior. Pressing too hard may result in damage to the view port.

  17. Wire 24VAC power to the ballast (20VA)
    a. If using 24V from furnace control board
    i. Make sure that the HVAC equipment can supply a minimum of 20VA
    ii. Connect the two black wires to the R and C terminals on HVAC Equipment
    b. If using a separate 24V transformer
    i. Install transformer per manufacturers specifications
    ii. Connect 24V to the two black wires at the transformers output terminals

  18. Restore power to all HVAC equipment and allow 30 seconds for equipment to reach steady state before checking LED indicator and view port for equipment status
    a. If UVC light can be seen escaping duct work immediately turn off power and seal discovered light paths with UV resistant sealer
    b. If LED indicator is solid and view port is illuminated, equipment is functioning properly
    c. If LED indicator is flashing, proceed to trouble shooting section for error code reference

For any inquiries, issues or concerns on a UV unit or system, contact:
AprilAire Customer Support: aprilaire.com/contact or Call: 800-334-6011

OPERATION

HOW TO OPERATE YOUR PRODUCT
The AprilAire AUV24V is an automatic unit that is designed to run constantly when powered on. As long as the blue glow can be seen through the viewport and the Ballasts LED indicator remains solid, no action is required for the product to continually sanitize the evaporator coil surface. SYSTEM OK – NO ACTION REQUIRED
LED FLASH 1X/ 1 SEC PAUSE – SEE TROUBLE SHOOTING SECTION 1
LED FLASH 2X/ 1 SEC PAUSE – SEE TROUBLE SHOOTING SECTION 2
LED FLASH 3X/ 1 SEC PAUSE – SEE TROUBLE SHOOTING SECTION 3
LED FLASH 4X/ 1 SEC PAUSE – SEE TROUBLE SHOOTING SECTION 4
LED FLASH 5X/ 1 SEC PAUSE – SEE TROUBLE SHOOTING SECTION 5
CAUTION: The suggested operating temperature range is 10 to 66°C (50 to 150°F). Operating the AprilAire AUV24V outside this range will result in decreased performance.
HOW TO READ THE BALLAST LED INDICATOR
The error code is determined by the LED flashing pattern on the ballast. The flashing pattern on the ballast is determined by the number of LED blinks (1 to 5) followed by a 1 second pause. This pattern will repeat continuously until the error code is cleared.

MAINTENANCE

• For 700 series humidifiers installed in direct proximity to exposure from a UVC Lamp, be sure to inspect feed tube annually and replace if discolored, cracked, brittle, or has visible damage.
LAMP REPLACEMENT
CAUTION: In order to avoid reduced performance of lamp, do not touch lamp glass without gloves. (clean with a lint free cloth or wipe and isopropyl rubbing alcohol if needed)

  1. Disconnect Power to Ballast and remove power cord from Lamp terminals. Allow the Lamp to cool fully before continuing with replacement.

  2. Remove the retaining ring by loosening the 2 screws on the retainer ring just enough to allow the retainer ring to be rotated freely. Turn retainer ring counterclockwise until the screw heads can pass through the retainer plate. Pull retaining ring away from unit to free Lamp from assembly.

  3. Carefully remove the UVC Lamp from the bracket by holding onto the exposed portion of the Lamp and pulling straight back until Lamp is completely removed from bracket.
    NOTE: UVC Lamps can be disposed/recycled after use as you would any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions.

  4. Put on included gloves and remove lamp from its individual packaging. Clean lamp with isopropyl rubbing alcohol if needed.

  5. Insert opposite end of lamp from the flange and connectors though center Lamp hole in bracket and duct. Once installed, repeat step 2 in reverse to secure Lamp in place. Do not over tighten screws.

  6. Reset the Ballasts Lamp maintenance timer. Press and hold Ballast reset button for 3 seconds or until LED indicator blinks. The timer has now been reset for 1 full year.

HOW TO CLEAN YOUR PRODUCT
CAUTION: Under no circumstance should water be sprayed or splashed onto the product. To clean Lamp, remove fully from unit per instructions in the lamp replacement sections steps 1- 3
For optimal performance, the lamp should be kept free of dust and residue deposit. To ensure this, it is recommended to clean once every two to three months with a soft tissue and alcohol-based solution. Always spot test the cleaner to make sure it does not damage the surface. See the Lamp Replacement section for instructions on how to safely remove Lamp for cleaning
ELECTRICAL RATINGS, POWER CONSUMPTION
The product is rated at 24 VAC.
See product label to confirm power consumption of your specific unit or system.

TROUBLESHOOTING

CAUTION: The user that changes or modifies the device without being expressly approved by the party responsible for compliance may void the user’s authority to operate the equipment.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
If your product is not working properly, refer to the following.
SECTION 1
Code 1 (EC1) – Lamp has reached 1 year of operation. Purchase a genuine replacement lamp and follow the instructions to replace the lamp in the Maintenance section Lamp Replacement and Timer Reset
SECTION 2
Error Code 2 (EC2) – Lamp has failed. – Press the reset button once to attempt to restart the lamp.

  • Shut off the power to the ballast (hard reset), wait 10 seconds and turn the power back ON.
  • Get a genuine replacement lamp and reset lamp timer or call customer service.

SECTION 3
Error Code 3 (EC3)

  • Ballast has failed.
  • Press the reset button once to attempt to restart the ballast.
  • Shut the power to the ballast (hard reset), wait 10 seconds and turn the power back ON.
  • Contact Dealer/AprilAire for Replacement of Ballast

SECTION 4
Error Code 4 (EC4) – Voltage to the ballast is less than 18VAC.

  • Power source (furnace control panel or transformer) does not provide sufficient power output (measured in VA).
  • Install a dedicated transformer (8029 or other UL approved transformer) that provides a minimum output of 20 VA at 24 VAC.
  • Contact your contractor or customer service

LIMITED WARRANTY

Your Research Products Corporation AprilAire® UVC Lamp is expressly warranted for one (1) year from date of installation to be free from defects in materials or workmanship. Any modifications to the product voids the warranty.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such one (1) year period and which is returned not later than thirty (30) days after said one (1) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the UVC Lamp.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE UVC LAMP ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECTS(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Your Research Products Corporation AprilAire® UVC Ballast is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship. Any modifications to the product voids the warranty.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the Ballast.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE UVC BALLAST ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECTS(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
WARRANTY REGISTRATION
Visit us online at www.aprilaire.com to register your AprilAire product. If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P.O. Box 1467, Madison, WI 53701.
Your warranty registration information will not be sold or shared outside of this company.

CUSTOMER SERVICE

FOR ADDITIONAL GUIDANCE OR TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR APRILAIRE CUSTOMER SERVICE
Toll-Free Phone #: 800.334.6011
Website: aprilaire.com/contact
CONTACT PAGE ON WEBSITE
Please be sure to specify product name.
Replacement parts for this product
AUVRPB Regular intensity 16” UVC Lamp
8029 Step-down transformer 120VAC to 24VAC (40VA)
WARNING
Use only specified AprilAire branded replacement UVC Lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

B2209998 • 61002237 • 11.22
© 2022 AprilAire | aprilairepartners.com | 800.334.6011
AprilAire reserves the right to change specifications without notice.