robuste R2011 Versatile IoT Router with 5 Ethernet Ports User Manual
- June 12, 2024
- robuste
Table of Contents
- Regulatory and Type Approval Information
- Radio Specifications for Europe
- Simplified EU Declaration of Conformity
- Safety Information
- Overview
- Package Checklist
- Panel Layout(May vary on difference models)
- Interface Descriptions
- Hardware Installation
- Login to the Device
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
R2011
Version: 1.0.1
Date: Nov. 28, 2022
Regulatory and Type Approval Information
Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits
Name of
the Part| Hazardous Substances
---|---
(pb)| (Hg)| (Cd)| (Cr(VI))| (PBB)| (PBDE)| (DEHP)| (BBP)| (DBP)| (DIBP)
Metal parts| o| o| 0| 0| –| –| –| | |
Circuit modules| o| o| 0| 0| 0| 0| 0| 0| 0| 0
Cables and cable assemblie s| o| 0| 0| 0| 0| 0| 0| 0| 0| 0
Plastic and polymeric parts| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0
o: Indicates that this toxic or hazardous substance contained in all of the
homogeneous materials for this part is below the limit requirement in RoHS2.0.
X: Indicates that this toxic or hazardous substance contained in at least one
of the homogeneous materials for this part might exceed the limit requirement
in RoHS2.0.
-: Indicates that it does not contain the toxic or hazardous substance.
Radio Specifications for Europe
RF technologies | 2G, 3G, 4G, Wi-Fi |
---|---|
Cellular Frequency* | 2G GSM: 83/B8 |
3G WCDMA: B1/B8
4G LTE FDD: B1/B3/B7/B8/B20/B28A LTE-TDD: 838/B40/B41
Max RF power| 33 dBm±2dB@GSM, 24 dBm+1/-3dB@WCDMA, 23 dBm±2dB@LTE, 18 dBm@Wi-
Fi
- May vary on difference models.
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC & IC Radiation Exposure Statement
This equipment complies with FCC and Canada radiation exposure limits set
forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of
20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Simplified EU Declaration of Conformity
We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is available at the following internet address: www.robustel.com/certifications/
Safety Information
General
- The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment.
- Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited.
- Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliance, etc.
- An external antenna must be connected to the router for proper operation. Only uses approved antenna with the router. Please contact authorized distributor on finding an approved antenna.
RF exposure
- This device meets the official requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
- The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable limits.
Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open.
Router may be used at this time.
The symbol indicates that the product should not be mixed with general household waste but must be sent to separate collection facilities for recovery and recycling.
**** The symbol indicates that the product meets the requirements of the applicable EU directives.
The symbol indicates that the product meets the requirements of the relevant UK legislation.
Related download link
Find more product documents or tools at:
www.robustel.com/en/documentations/
Technical Support
Tel: +86-20-82321505
Email: support@robustel.com
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest
document version contains all updates made to previous versions.
Date| Firmware Version| Document Version| Change
Description
---|---|---|---
06-Jul-22| 5.0.0| 1.0.0| Initial release.
Nov. 28, 2022| 5.0.0| 1.0.1| Added declaration for product.
Overview
Robustel R2011 Industrial Cellular Router is a rugged, versatile 4G router with 5 Ethernet ports, dual SIM single standby capability and a range of advanced functions for mission critical IoT or M2M applications.
Package Checklist
Before commencing installation ensure your package has the following components:
Note: The accessories could be different on specific order.
Panel Layout(May vary on difference models)
Interface Descriptions
- Power Supply. 2-pin 3.5 mm male terminal block
PIN| Description| Note|
---|---|---|---
1| V+| Positive| Note: Voltage input range:9-36V
2| V-| Negative
2. LED Indicator
Name | Color | Status | Description |
---|---|---|---|
RUN | Green | On, solid | Router is powered on (System is initializing) |
On, blinking | Router starts operating | ||
Off | Router is powered off | ||
MDM | Green | On, solid | Successful link connection |
On, blinking | Link connection is working | ||
Off | Link connection is not working | ||
Wi-Fi | Green | On, solid | Wi-Fi is working normally |
Off | Wi-Fi is not working or abnormal | ||
RSSI | Green | Three lights on | Signal Level: Best Signal Level |
Wireless module: 21-31dB (signal strength)
Two lights on| Signal Level: Average Signal Level
Wireless module: 11-20dB (signal moderate)
One light on| Signal Level: Abnormal Signal Level Wireless module: 21-31dB
(signal weak)
Off| No signal
Note: You can choose the display type of USR LED. For more details, please
refer to
RT123_SM_RobustOS Software Manual, Services > Advanced > System >System
Settings > User LED Type.
3. Reset Button
Feature | Operation |
---|---|
Reboot | Press and hold the RST button for 2— 5 seconds under the operating |
status.
Restore to default configuration| Press and hold the RST button for 5-10
seconds, the RUN LED starts blinking quickly, the router will restore to
default configuration.
Restore to factory default settings| Once the operation of restoring default
configuration is performed twice within one minute, the router will restore to
factory default settings.
Note: The more details please refer to RT123 SM Robust OS Software Manual, 2.3
Factory Reset.
4. Ethernet Ports.
There are five Ethernet ports on R2011 Gateway, including ETH0 (WAN/LAN) and
ETH1, ETH2, ETH3, ETH4. Each has two LED indicators. The green one is a link
indicator but the yellow one doesn’t mean anything. For details about status,
see the table below.
Ethernet LED Indicator | Status | Description |
---|
Link indicator
(Green)| On, solid| Connection is established
On, blinking| Data is being transferred
Off| Connection is not established
Hardware Installation
-
SIM Card Installation. Remove the SIM card cover to insert the SIM cards into the device, then screw up the cover.
-
Antenna Installation. Rotate the antenna into the antenna connector accordingly. Here take the cellular antenna as example.
-
Mounting Kit installation.
① Wall mounting
② DIN rail mounting
-
Power Supply installation. Insert the power supply cord into the corresponding terminal block if needed, then insert the terminal block into the power connector.
-
Connect the Router to a Computer. Use a standard network cable to connect the Ethernet port of the router to a PC, when it is configured as 5 LAN, it can be connected to (ETH0~ETH4); when it is configured as 1 WAN+4 LAN, it can be connected to (ETH1~ETH4) ).
-
Grounding the Device. Grounding will help to prevent the noise effect due to electromagnetic interference (EMI). Connect the device to the site ground wire by the grounding screw before powering on.
Login to the Device
-
Connect the router’s Ethernet port to a PC with a standard Ethernet cable.
-
Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.
-
To enter the gateway’s web interface, type http://192.168.0.1 into the URL field of your Internet browser.
-
Use login information shown in the product label when prompted for authentication.
-
After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.
-
The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.
-
The more configuration details please refer to RT123_SM_RobustOS Software Manual. (END)
Support: support@robustel.com
Website: www.robustel.com
© 2022 Guangzhou Robustel Co.,Ltd.
All rights reserved. Subject to change without notice.
RT070_HM_R2011
References
- 4G/LTE/5G/Cellular Routers, Gateways and Modems for Industrial IoT - Robustel
- 4G/LTE/5G/Cellular Routers, Gateways and Modems for Industrial IoT - Robustel
- Certifications | Robustel - Industry-leading IoT Solutions Provide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>