Square D XUM4ApXBp XUM Photo Electric Sensors Instruction Manual
Square D XUM4ApXBp XUM Photo Electric Sensors

Photo-electric sensors – Miniature design

Photo-electric sensors - Miniature design

QR Code

http://qr.tesensors.com/XU0007

 Scan the code to access this Instruction Sheet and all product information in different languages or you can visit our website at: www.tesensors.com

We welcome your comments about this document. You can reach us through the customer support page on your local website.

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • Disconnect all power before servicing equipment.
  • Do not connect this device to AC power.
  • The power voltage must not exceed the rated range.

Failure to follow these instructions will result in death or serious injury.

WARNING

IMPROPER SETUP OR INSTALLATION

  • This equipment must only be installed and serviced by qualified personnel.
  • Read, understand, and follow the compliance below, before installing the XUM Photo-electric sensor.
  • Do not tamper with or make alterations on the unit.
  • Comply with the wiring and mounting instructions.
  • Check the connections and fastening during maintenance operations.
  • The proper functioning of the XUM photoelectric sensor and its operating line must be checked regularly and according to the application (for example number of operations, level of environmental pollution, etc.).

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Mounting and tightening torques

Mounting and tightening torques

LEDs and settings

LEDs and settings

Wiring diagrams

Wiring diagrams

Electrical equipment should be installed, operated and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
© 2023 Schneider Electric. “All Rights Reserved.”

Wiring precaution

NOTICE
REDUCTION OF SERVICE LIFE
Do not pull on the sensor cable.
Failure to follow these instructions can result in equipment damage.

Dimensions

Dimensions
Dimensions
Dimensions

Accessories

Mounting brackets (to order separately)

Accessories
Accessories

Pre-wired connectors (examples)

PVC cable for general use
PUR cable for severe industrial environments

M8, 4 pins

Cable length

| | | M8 – M12,

4 pins

Jumper length

|
PUR
|
PUR

---|---|---|---|---|---
PVC| PUR| PVC| PUR

2 m / 6.56 ft.

|

XZCPV0941L2

|

XZCP0941L2

|

XZCPV1041L2

|

XZCP1041L2

|

1 m / 3.28 ft.

|

XZCR1509041J1

|

XZ CR1510041J1

5 m / 16.4 ft.

|

XZCPV0941L5

|

XZCP0941L5

|

XZCPV1041L5

|

XZCP1041L5

|

2 m / 6.56 ft.

|

XZCR1509041J2

|

XZCR1510041J2

10 m / 32.8 ft.

|

XZCPV0941L10

|

XZCP0941L10

|

XZCPV1041L10

|

XZCP1041L10

| | |

Sensors position adjustment

Sensors position adjustment

Anti-interference for side by side mounting

Anti-interference system to ensure good detection even disturbed by another sensor when mounted side by side

Anti-interference system allows a side by side installation and ensures a reliable detection.

This Anti-interference system ensures an object detection in all conditions.

Output mode setting: Light-On or Dark-On (Light-On by default)

Output mode setting

Sensor sensitivity adjustment

For an accurate detection, follow the set up below. (eg. Dark objects, with holes or with small size to reflect properly the light beam).

| Light-On| Dark-On
---|---|---
| 1-Connect the sensor to the power supply (see page 1 for the wire connection & page 7 for the power voltage).

Before settings, start with the potentiometer at the minimum position (resulting to point A).

| 1-Connect the sensor to the power supply (see page 1 for the wire connection & page 7 for the power voltage).

Before settings, start with the potentiometer at the minimum position (resulting to point A).

| 2-Put the object in front of the sensor. Turn clockwise the potentiometer until the output led (yellow) switches on (resulting to point B).

| 2-Put the object in front of the sensor. Turn clockwise the potentiometer until the output led (yellow) switches off (resulting to point B).

| 3-For a stable detection, turn the potentiometer clockwise until the stability led (green) switches on & the output led (yellow) remained on (resulting to point C).

| 3-For a stable detection, turn the potentiometer clockwise until the stability led (green) switches on & the output led (yellow) remained off (resulting to point C).

| 4-The sensor is set and ready to detect

| 4-The sensor is set and ready to detect

Detection curves

XUM4: Diffuse reflective (0,25 m) – Object size / Sensing distance
XUM5: Diffuse reflective (1,9 m) – Object size / Sensing distance
XUM6: Diffuse reflective (1,1 m) – Object size / Sensing distance

Detection curves

XUM4: Diffuse reflective (0,25 m) – Lateral displacement
XUM5: Diffuse reflective (1,9 m) – Lateral displacement
XUM6: Diffuse reflective (1,1 m) – Lateral displacement

Detection curves

XUM4: Diffuse reflective (0,25 m) – Excess gain
XUM5: Diffuse reflective (1,9 m) – Excess gain
XUM6: Diffuse reflective (1,1 m) – Excess gain

Detection curves

Characteristics

Certification CE – UKCA – cULus

Sensing Range (using a white paper 200 x 200) Max. sensing distance (excess gain=1)| XUM5: 1,9 m – excess gain =1
1,5 m – excess gain=2
XUM6: 1,1 m – excess gain =1
0,8 m – excess gain=2
XUM4: 0,25 m – excess gain =1
0,17 m – excess gain=2
Color of detection light beam| XUM6: Red – XUM5 / XUM4: Infrared
Blind zone| XUM4 / XUM5 / XUM6: 10 mm
Hysteresis| 2% < H < 20% (at most sensitivity, white paper)
Sensing distance setting| Potentiometer 1 turn (~ 240 degres)
Light-On/Dark-On selection| Switch (~ 120 degres)
Output type| PNP or NPN
ON Voltage drop| 2 V max. (30 Vdc 100 mA) / 1,2 V max. (30 Vdc 10mA)
Current consumption| < 20 mA max.
Switching capacity| 100 mA
Response time| 0,5 ms max
Recovery time| 0,5 ms max
Switching frequency| 1000 Hz
Electrostatic discharge immunity| 4 kV (Contact), 8 kV (Air) conforming to IEC 61000-4-2
Electromagnetic field immunity| 10 V/m conforming to IEC 61000-4-3
Fast transients immunity| Burst 5 kHz – 2kV conforming to IEC 61000-4-4
Conducted disturbances immunity| 10 V conforming to IEC 61000-4-6
Emissivity Radiated disturbances| Class A conforming to EN 55011 / CISPR 11
Power Voltage| Rated operational voltage: 12…24 Vdc Ripple p-p 10% maximum
Operating range: 10…30 Vdc (including ripple)
Product protection| Power supply : Reverse polarity protection
Output: Short circuit protection
Reverse polarity protection
Light Immunity| Operating atmosphere;
Sunlight 40 kLx max.
Incandescent light 10 kLx max
Ambient Temperature| Operating : – 30…+55 °C (-22…+131 °F), Storage : – 40…+70 °C (-40…+158 °F)
Ambient Humidity| Operating : 35…95% RH, Storage : 35…95% RH
Degree of protection| IP65, IP67 conforming to IEC 60529
Vibration resistance| Frequency range: 10 Hz to 500 Hz
Acceleration: 9 gn
Shock resistance| Peak acceleration: 100 gn
Duration of the pulse: 11 ms
Material| Housing: PBT, Lens: PMMA, Operation cover: PC, Adjustment potentiometer: PBT

Manufacturer :
Schneider Electric Industries SAS
35 rue Joseph Monier
92500 Rueil Malmaison
France

UK Representative :
Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL
United Kingdom

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals