Hom-io 559503047 CronoTermostato Digital Wifi Instruction Manual

June 12, 2024
Hom-io

Hom-io 559503047 CronoTermostato Digital Wifi

Hom-io-559503047-CronoTermostato-Digital-Wifi-fig-1

Android also can search “Smart life” at Google Play, iPhone also can search or “Smart life” at App Store.

  • Turn on the thermostat, long press for 3-5 seconds, the “OFF” and will flashing in the same time, short press for pairing thermostat with APP.

Package Contents

  • Digital Thermostat 1 pc
  • User manual 1 pc
  • Assembly kit 503 1 pc

Product Specifications

  • Power: 90-240Vac 50/60HZ
  • Display accuracy: 0.5°C
  • Probe sensor: NTC(1 Ok) 1 %
  •   Contact capacity: 3N250V{WW); 16N250V (WE)
  • Working environment temperature: 0~90°C
  • Range of temperature adjustment: 5~35°C
  • Range of temperature display: 0~70°C
  • Insulating condition: Normal environment
  • Running program: Set per 1 week as a cycle
  •   Output: Switch relay
  • Installation: Wall mounted or on battery seat
  • Size (mm): 868630

Before wiring and installing

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application.
  3. Installer must be a trained experienced service technician.
  4.  After installation is complete check out produce operation as provided in these instructions
    CAUTION Electrical shock or equipment Damage Hazard or short equipment circuitry.

Wiring Diagram

  • Electric heating wiring diagram

  • Water heating wiring diagram (do not connect terminal “close 4” of electric valve)

  • Water heating and gas wall-hung boiler heating, no contact wiring diagram, (disconnection when electric valve close).

Note: 3 & 4 connect with power, 5 & 6 connect with gas boiler, 1 & 2 connect with thermal actuator, please do not connect 1 &2 to gas boiler,lf you connect it wrongly, there will be Short circuit, our gas boiler board will be damaged.

Displays

Description of icon

Hom-io-559503047-CronoTermostato-Digital-Wifi-fig-9

Operation key

Hom-io-559503047-CronoTermostato-Digital-Wifi-fig-10

Programmable

5+2 (factory default), 6+ 1 and 7 models 6 times period setting for user choose. In the advanced options choose model of you need, under power on state, long press for 3-5 seconds enter into programming mode setting, then short press choose: hour, minute, time period, and press to adjust data, finished setting, about 10 seconds will automatic save and exist.

Hom-io-559503047-CronoTermostato-Digital-Wifi-fig-12

The optimum comfort temperature is 18°C-22°C.

A Advanced options

Under turn off state, long press for 3-5 seconds to access advanced setting.
From A 1 to AE, short press : to choose the option, and adjust data by , short press to switch next option. Remain about 10 seconds after finish setting will quit setting.


NO

| ****

Setting Options

| ****

Data Setting Function

| ****

Factory Default

---|---|---|---
Al| Measure Temperature Calibration| -9 I +9 °C| 0.5 °C Accuracy Calibration


A2

| Measure Temperature Calibration| 0.5 I 2.5 °C| 1 °C
A3| Children lock setting| 0: half lock                1: full lock| 0: half lock


A4

| Power with memory function| 0: Power with memory function

1: Shutdown power after power off 2: Shutdown power after power on

| 0
AS| Backlight Sleep time| time 5-30 Sec 10| 10 Sec


AG

| Weekly programming selection| 0: 5 + 2

1:6+ 1

2:7

| ****

0


A7

| Setting temperature lowest limit| 1 / 10 °C| 5 °C


AS

| Setting temperature highest Limit| 20 /70 °C| ****

35 °C


A9

| Limit value of low temperature for external sensor (anti-freeze protection)| 1. 1 / 10 °C

2. Exc eed 10 °C, scre en display [–],Low temperature protection was cancelled.

| ****

S °C


AA

| Limit value of high temperature for external sensor| 1. 35 /70 °C

2. Under 35 °C, screen displ ay [ — ] , high temperature protection was cancelled.

| ****

45 °C


AB

| External sensors limit temperature control return difference| 1 /9 °C| 2 °C



AC

| Window ventilation function setting| Press  ,display 10°C, when temperature 10°C turn on window ventilation function, stop heating mode, press   display–, turn off Window ventilation| Disabled —


AD

| Window ventilation running time| 10/20 mins| 10mins


AE

| Restore factory defaults| Long press key  , Display A, press OK key whole show|

Advanced options

Under turn off state, long press for 3-5 seconds to access advanced setting.
From BN to BO, short press to choose the option, and adjust data by , short press to switch next option. Remain about 10 seconds after finish setting will quit setting.

NO

| Setting Options| Data Setting Function| Factory Default
---|---|---|---

BN

|

Options of sensor control

| N1: Built-in sensor (high temperature protection close) N2: External sensor (high temperature protection close) N3: Built-in sensor control temperature, external sensor limit temperature (external sensor detect the temperature is higher than highest temperature of external sensor, thermostat will disconnect relay, turn off load)| N1

BC

|

Descaling function

| 0: Close descaling function

1: Open descaling function (valve is continuously closed over 100 hours, it will be opened for 3 minutes automatically

| 0

BO

| Procedure parameters| unchangeable| 10

Return Difference: limit valve of external sensor is 45 °C for factory default (A6), value of external sensor control return difference (A3) is 2. When temperature rise to 45 °C, then relay stop working and will remind high temperature production alarm. If temperature decline to 43°C relay continue to work and heating alarm will be relieved. (it can be operated, only when indoor temperature is lower than setting temperature).
Sensor Fault Display: please choose correct working way of built-in and external sensor, if choose wrongly or sensor  fault (breakdown), “E1 “or”E2″will be displayed on the screen. Thermostat will stop heating until the fault is eliminate

Installation

Hom-io-559503047-CronoTermostato-Digital-Wifi-fig-14

Product Compliance

According to Directive 2012/19/EU of the European Parliament and of the Council, of 4 july 2012, on waste electrical and electronic equipment (WEEE), the presence of the crossed-out bin symbol indicates that this appliance is not to be considered as urban waste: its disposal must therefore be carried out by separate – collection. Disposal in a non-separate manner may constitute a potential harm to the environment and health. This product can be returned to the distributor when purchasing a new device. Improper disposal of the appliance constitutes misconduct and is subject to sanctions by the Public Security Authority. For further information, contact the local administration responsible for environmental matters.

Simplified EU Declaration of Conformity

  • Hereby, manufacturer Melchioni S.p.A. declares that the radio equipment type Wi-Fi Digital Thermostat Mod.
  • HOM-TERMO-PLUS (code 559593047) is in compliance with Directive 2014/53/EU.
  • The full text of the EU declaration of conformity is available at the following internet address: http://www.melchioni.it.

ABOUT COMPANY

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hom-io User Manuals

Related Manuals