ProNav AlphaBNWAS Bridge Navigational Watch Alarm System Instruction Manual

June 12, 2024
ProNav

ProNav AlphaBNWAS Bridge Navigational Watch Alarm System

ProNav-AlphaBNWAS-Bridge-Navigational-Watch-Alarm-System-PRODUCT-
IMG

  • Compact design to fit in any existing console
  • Easy to install and operate
  • Set-up is protected by key-switch
  • Extendible with other alarm with Alarm Unit

ProNav-AlphaBNWAS-Bridge-Navigational-Watch-Alarm-System-
FIG-1

Features

A Bridge Navigational Watch Alarm System (BNWAS) is an aid to help protect the Ship’s Officers required to ensure the presence of the Officer of the Watch on the bridge and to carry out one-man bridge duties. A BNWAS monitors bridge activity and detects any absence on the bridge that could lead to shipping accidents. The BNWAS system monitors the awareness of the Officer of the Watch (OOW) and warns the Master and/or another qualified Officer if the Officer of the Watch becomes incapable of performing duties through whatever cause.

  • Cost-effective design
  • Operator friendly
  • IMO approved
  • Flexible configuration
  • Uniform product philosophy
  • Extendable by means of extra reset buttons
  • Reports to the officer’s cabins
  • Dimming function
  • Possibility to switch on automatically with the autopilot
  • Communication interface to VDR and ECDIS (NMEA)

Integrate in design

The AlphaBNWAS is available in standard- and MF line versions. When the AlphaBNWAS system is implemented into an Alphabridge design, a separate version of the control unit will be available with a modified front panel to comply with the recognizable corporate Alphabridge black or grey style.

Approved system

  • Ship owners can now meet these requirements in a cost-effective way by choosing the Alphatron Watch Alarm system called the AlphaBNWAS.
  • The AlphaBNWAS is a Bureau Veritas MED-certified Bridge Navigational Watch Alarm System mandatory on SOLAS vessels of 150GT and up and passenger vessels irrespective of the size of the vessel.

Alarm stages

ProNav-AlphaBNWAS-Bridge-Navigational-Watch-Alarm-System-
FIG-2

1st stage alarm

Once the dormant period ends, a visual indication inside the main unit will be activated. If not reset within 15 seconds of the visual indication, an audible alarm is sounded. This main unit is on the bridge and warns the person on watch he should reset the alarm. The alarm can be reset on the main unit or on the remote reset button or with a motion sensor. If the person on watch does not reset the alarm within 30 seconds the second stage alarm will sound.

2nd stage alarm
If at the first stage the audible alarm is not reset, 15 seconds after the audible alarm, another audible alarm is sounded in the backup officer’s and/or Master’s cabin. This can also be done by using the officer’s selector switch (optional), that can connect up to 6 different officers cabin units.

3rd stage alarm
If at the second stage the audible alarm is not reset, 90 seconds after it, another unique audible alarm with sufficient volume is sounded at the locations of further crew members capable of taking corrective actions. If the officer does not reset within 3 minutes the 3rd stage alarm will sound all over the vessel.

  • Except for passenger’s vessels, the second and third stage alarm can be combined to sound at all locations. If this is applied, the third stage alarm may be omitted.
  • For very large vessels, sufficient time of up to 3 minutes must be accounted for the backup officer or the Master to the reach the Bridge to tend to the situation.

Specifications

Main unit

Power supply| 18-28 VDC@180mA max
Input| Reset
Output| 4 potential free
Mounting| Flush mount
Protection| Set-up is protected by key-switch
Dimensions
Standard version| 72x144x88 (WxHxD); Cut out: 67×139 (WxH)
MF line version| 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
Buzzer Unit|
---|---
Power supply| 18-33 VDC@30mA max
Dimensions|
Standard flush mount| 72x96x70mm (WxHxD) Cut out: 67×91 (WxH)
Standard wall mount| 80x105x28mm (WxHxD)
MF line version| 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
Reset Unit|
---|---
Power supply| 18-33 VDC@30mA max
Dimensions|
Standard| 72x96x70mm (WxHxD); Cut out: 67×91 (WxH)
MF line| 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
Selector Switch|
---|---
Power supply| 18-28 VDC@10mA max
Dimensions|
Standard| 72x144x70mm (WxHxD)

Cut out: 139×67 mm (WxH)

MF line| 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
10 Channel Alarm Unit|
---|---
Power supply| 18-30VDC@150mA
Interface| Modbus interface (RS485)
Input (digital)| 10 digital inputs (NO/NC)
Output| 3 group outputs
Input| 3 lock inputs
Alarm relay| Potential free alarm relay
Dimensions|
Standard| 72x144x75mm (WxHxD);

Cut out: 139×67 mm (WxH)

Horn|
---|---
Power supply| 8-35VDC
Operating Temp| -25°C to + 70°C / IP65
Frequency| 400-2850Hz
Dimensions|
Standard| 98x104mm (RxH)
PIR Sensor|
---|---
Specifics| 110° angle and 360° overview
Dimensions|
Standard| 59x107x39mm (WxHxD)

Tech Specs

Main unit G-002351

Buzzer Unit G-002369

Reset Unit G-002368

Selector Switch G-002370

In the box

AlphaBNWAS MF Line

  • AlphaBNWAS Main unit -Alpha MF line
  • AlphaBNWAS Reset unit -Alpha MF line
  • AlphaBNWAS cabin unit buzzer -Alpha MF line
  • AlphaBNWAS selector -Alpha MF line
    • G-002362
    • G-002365
    • G-002366
    • G-002367
    • G-002364
    • G-002368
    • G-002369
    • G-002370

AlphaBNWAS

  • AlphaBNWAS Main Unit watch alarm, flush mount LR approved
  • AlphaBNWAS cabin unit buzzer, flush mount
  • AlphaBNWAS cabin unit buzzer, wall mount
  • AlphaBNWAS reset button
  • AlphaBNWAS selector switch
  • AlphaBNWAS outdoor wing remote reset
    • G-002351
    • G-002352
    • G-002374
    • G-002354
    • G-002355
    • G-002357

Accessories

  • AlphaBNWAS 10 Channel Alarm Unit
  • AlphaBNWAS Alarm horn
  • AlphaBNWAS connection box
  • AlphaBNWAS Flush mount bracket for Buzzer-and reset unit mounting
  • AlphaBNWAS wall mounting box
  • AlphaBNWAS Flush mount bracket for main-unit mounting
  • AlphaBNWAS NMEA activation unit
  • AlphaBNWAS Main connection board
  • AlphaBNWAS Extension connection board
  • AlphaBNWAS Selector switch connection board
  • AlphaBNWAS motion sensor
  • Cable to connect Main Unit to Main Connection board, 2 meter
    • G-002350
    • G-002353
    • G-002356
    • G-002371
    • G-002359
    • G-002360
    • G-002361
    • G-006949
    • G-002371
    • G-002372
    • G-002373
    • G-002375
    • NL1-003200

JRC Tokyo

  • 1-7-32 Tatsumi, Koto-ku
  • Tokyo 135-0053
  • Japan
  • +81 3 5534 7800

JRC/Alphatron Marine B.V.

  • Schaardijk 23
  • 3063 NH Rotterdam
  • The Netherlands
  • +31 10 453 4000

JRC Shanghai

  • Floor 9-A Building C2,
  • Shanghai International Trade Center,
  • 1599 New Jinqiao Road,
  • Pudong, Shanghai, China 201206
  • +86-21-2024-0607

JRC South East Asia

  • 100 Pasir Panjang
  • 118518 Singapore
  • Singapore
  • +65 6863 0335

JRC/ProNav AS

  • Hovlandsveien 52
  • 4374 Egersund
  • Norway
  • +47 5146 4300

JRC Americas

  • 1205 Butler Road
  • TX 77573 Houston
  • United States of America
  • +1 281 271 4600
  • www.pronav.no

Product and/or specifications could change without notice © All rights reserved, JRC/AM -20.06/207/2