SANPU LLP100 Power Supply

Product Information

  • Product Name: LLP100 CV+CC
  • Manufacturer: Shenzhen SANPU Intelligent Technology Co., Ltd.
  • Features:
    • 100% full load burn-in test
    • Universal AC input
    • Small size and high efficiency
    • Conforms to EMC EN5502 GB9254
    • Built-in EMI filter with tiny ripple
    • Complies with safety standards UL60950 GB4943 EN60850
    • Protection against short circuits, overvoltage, overload, and temperature

Product Usage Instructions

The LLP100 CV+CC is a power supply unit that provides a regulated output voltage for various applications. Please follow the instructions below for proper usage:

  1. Check the model number on the product to ensure it is the correct version for your requirements. The available models are LLP100-W1V12 (12V output) and LLP100-W1V24 (24V output).
  2. Connect the AC input to a universal power source within the specified input voltage range.
  3. Ensure the AC input current is within the recommended limits.
  4. Connect the output of the power supply to your device or circuit, making sure to match the required voltage (12V or 24V) and current specifications.
  5. Verify that the output voltage error is within acceptable limits. If not, please contact the manufacturer for assistance.
  6. Monitor the output current to ensure it stays within the rated output current range. Do not exceed the maximum output power.
  7. Check for any ripple and noise in the output and take appropriate measures if necessary.
  8. Ensure proper power factor by maintaining the recommended input voltage range.
  9. During cold start, monitor the current and ensure it is within expected levels. Also, note the start, rise, and hold time for reference.
  10. Monitor the static current to ensure it is within acceptable limits.
  11. Take note of the overload protection feature, which safeguards against excessive current.
  12. Be aware of the short circuit protection and the over temperature protection features to prevent any damage to the power supply or connected devices.

Environment and Safety Standards:

  • Working Temperature: [Provide temperature range]
  • Working Humidity: [Provide humidity range]
  • Storage Temperature: [Provide temperature range]
  • Storage Humidity: [Provide humidity range]
  • Withstand Voltage: [Provide voltage]
  • Insulation Resistance: [Provide resistance]
  • Safety Standards: [Provide safety standards]
  • EMC Standards: [Provide EMC standards]

FEATURES

  • 100% full load burn-in test
  • Universal AC input
  • Small size and high efficiency
  • Conform to EMC EN5502 GB9254
  • Built-in EMI filter with tiny ripple
  • Comply with the safety standards UL60950 GB4943 EN60850
  • Protection: short circuit/over Voltage/over/load temperature
MODEL LLP100-W1V12 LLP100-W1V24

OUTPUT

| Rated Voltage| 12V| 24V
No-load voltage| <12.6V| <24.6V
Output voltage error| 12V±5%| 24V±3%
Rated output current| 8.3A±10%| 4.2A±10%
Output current range| 0~8.3A| 0~4.2A
Rated output power| 100W| 100W
Maximum Output Power| 105W| 105W
Ripple and Noise| ≤120mVp-p| ≤150mVp-p

INPUT

PROTECTION

| POWER FACTOR(Typ.)| 0.6| 0.6
Input Voltage Range| AC 110~240V; 47Hz~63Hz
AC input current| 1.0A/AC 115V; 0.5A/AC 230V
Efficiency| 86%
Cold start current| 30A/AC230V
Start, rise, hold time| 2000ms,50ms,20ms
Static current| <10mA/240VAC

Overload protection

| 105-120% of rated power 100W Hiccup mode,

the circuit returns to normal after the abnormal condition is removed

Overcurrent protection

| Circuit protection is when the maximum voltage exceeds the circuit; when the abnormality is removed, the circuit returns to normal.
Short circuit protection| Short circuit more than 3 times, no damage, can automatically recover.

Over temperature protection

| ≥105℃ start protection;

circuit output normal after temperature returns to normal

ENVIRONMENT

| WORKING TEMP, HUMIDITY| -20℃~60℃;20%~90%RH
WORKING HUMIDITY| -40℃~85℃;10%~95%RH
STORAGE TEMP, HUMIDITY| 10~500Hz 2G 10.min/1 cycle Time duration 60 minutes Each axis

SAFETY

| WITHSTAND VOLTAGE| AC/DC: 3KV
Insulation resistance| Between input and output 100M ohm s/DC500V

STANDARDS

| Safety Standards| EN62368;EN61347
EMC standards| EN55032

PACKAGE

| Weight| Product Net Weight Kg
---|---|---
Packing| Carton Size: 395295210mm 100PCS/CTNS

Special Instructions

| 1.  all parameters are measured at AC220V voltage input, rated load and 25°C, when not specified otherwise.

2.  ripple and noise voltages are measured at the end of a 20 MHz bandwidth oscilloscope with 12″ twisted pair plus 0.1 uF and 47 uF.

Structural Parameters and Guidance for Use

Power Supply Appearance and Dimensions

Derating Curve

Static Characteristics(12V)

REMARKS:

  1. The above-mentioned data were measured at 230VAC input and 25°C.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Cut the AC input before checking any mal phenomenons.
  4. Make sure the INPUT &OUPUT were in the right situation before connecting to the power supply.
  5. Be aware of high power pressure may be caused by short circuits when installing metal casing products.
  6. Please contact us at [email protected] for further solution if any unforeable problem happens

Tel : 086 755 2306 0905
Fax : 086 755 2304 1269
Website : www.smpspower.com
Add: 5th Floor, B3 Building, Huafeng Shiji Industrial park, Hangcheng Road, Xixiang, Bao’an district, Shenzhen P.R.C.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SANPU User Manuals

Related Manuals