- Features:
- 100% full load burn-in test
- Universal AC input
- Small size and high efficiency
- Conforms to EMC EN5502 GB9254
- Built-in EMI filter with tiny ripple
- Complies with safety standards UL60950 GB4943 EN60850
- Protection against short circuits, overvoltage, overload, and temperature
Product Usage Instructions
The LLP100 CV+CC is a power supply unit that provides a regulated output voltage for various applications. Please follow the instructions below for proper usage:
- Check the model number on the product to ensure it is the correct version for your requirements. The available models are LLP100-W1V12 (12V output) and LLP100-W1V24 (24V output).
- Connect the AC input to a universal power source within the specified input voltage range.
- Ensure the AC input current is within the recommended limits.
- Connect the output of the power supply to your device or circuit, making sure to match the required voltage (12V or 24V) and current specifications.
- Verify that the output voltage error is within acceptable limits. If not, please contact the manufacturer for assistance.
- Monitor the output current to ensure it stays within the rated output current range. Do not exceed the maximum output power.
- Check for any ripple and noise in the output and take appropriate measures if necessary.
- Ensure proper power factor by maintaining the recommended input voltage range.
- During cold start, monitor the current and ensure it is within expected levels. Also, note the start, rise, and hold time for reference.
- Monitor the static current to ensure it is within acceptable limits.
- Take note of the overload protection feature, which safeguards against excessive current.
- Be aware of the short circuit protection and the over temperature protection features to prevent any damage to the power supply or connected devices.
Environment and Safety Standards:
- Working Temperature: [Provide temperature range]
- Working Humidity: [Provide humidity range]
- Storage Temperature: [Provide temperature range]
- Storage Humidity: [Provide humidity range]
- Withstand Voltage: [Provide voltage]
- Insulation Resistance: [Provide resistance]
- Safety Standards: [Provide safety standards]
- EMC Standards: [Provide EMC standards]
FEATURES
- 100% full load burn-in test
- Universal AC input
- Small size and high efficiency
- Conform to EMC EN5502 GB9254
- Built-in EMI filter with tiny ripple
- Comply with the safety standards UL60950 GB4943 EN60850
- Protection: short circuit/over Voltage/over/load temperature
MODEL | LLP100-W1V12 | LLP100-W1V24 |
---|
OUTPUT
| Rated Voltage| 12V| 24V
No-load voltage| <12.6V| <24.6V
Output voltage error| 12V±5%| 24V±3%
Rated output current| 8.3A±10%| 4.2A±10%
Output current range| 0~8.3A| 0~4.2A
Rated output power| 100W| 100W
Maximum Output Power| 105W| 105W
Ripple and Noise| ≤120mVp-p| ≤150mVp-p
INPUT
PROTECTION
| POWER FACTOR(Typ.)| 0.6| 0.6
Input Voltage Range| AC 110~240V; 47Hz~63Hz
AC input current| 1.0A/AC 115V; 0.5A/AC 230V
Efficiency| 86%
Cold start current| 30A/AC230V
Start, rise, hold time| 2000ms,50ms,20ms
Static current| <10mA/240VAC
Overload protection
| 105-120% of rated power 100W Hiccup mode,
the circuit returns to normal after the abnormal condition is removed
Overcurrent protection
| Circuit protection is when the maximum voltage exceeds the circuit; when the
abnormality is removed, the circuit returns to normal.
Short circuit protection| Short circuit more than 3 times, no damage, can
automatically recover.
Over temperature protection
| ≥105℃ start protection;
circuit output normal after temperature returns to normal
ENVIRONMENT
| WORKING TEMP, HUMIDITY| -20℃~60℃;20%~90%RH
WORKING HUMIDITY| -40℃~85℃;10%~95%RH
STORAGE TEMP, HUMIDITY| 10~500Hz 2G 10.min/1 cycle Time duration 60 minutes
Each axis
SAFETY
| WITHSTAND VOLTAGE| AC/DC: 3KV
Insulation resistance| Between input and output 100M ohm s/DC500V
STANDARDS
| Safety Standards| EN62368;EN61347
EMC standards| EN55032
PACKAGE
| Weight| Product Net Weight Kg
---|---|---
Packing| Carton Size: 395295210mm 100PCS/CTNS
Special Instructions
| 1. all parameters are measured at AC220V voltage input, rated load and 25°C, when not specified otherwise.
2. ripple and noise voltages are measured at the end of a 20 MHz bandwidth oscilloscope with 12″ twisted pair plus 0.1 uF and 47 uF.
Structural Parameters and Guidance for Use
Power Supply Appearance and Dimensions
Derating Curve
Static Characteristics(12V)
REMARKS:
- The above-mentioned data were measured at 230VAC input and 25°C.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Cut the AC input before checking any mal phenomenons.
- Make sure the INPUT &OUPUT were in the right situation before connecting to the power supply.
- Be aware of high power pressure may be caused by short circuits when installing metal casing products.
- Please contact us at in@smpspower.com for further solution if any unforeable problem happens