INTERMATIC ST01 Heavy-Duty Programmable Timer User Guide
- June 12, 2024
- Intermatic
Table of Contents
INTERMATIC ST01 Heavy-Duty Programmable Timer
Product Information: In-Wall Timer with Astro or Countdown
Feature
The In-Wall Timer with Astro or Countdown Feature is a programmable timer
designed for residential and commercial applications. It allows you to
automate the operation of various electrical devices based on a pre-set
schedule. The timer has several features, including adjustable timing
settings, language selection, and the ability to program specific events or
use pre-set templates. It is compatible with a wide range of loads, including
resistive, tungsten, ballast, electronic ballast, motor, and DC loads.
Ratings
- Operating Voltage: 120-277 VAC, 50/60 Hz
- Resistive (heater): 15 A, 120-277 VAC
- Tungsten (incandescent): 15 A, 120 VAC; 6 A, 208-277 VAC
- Ballast (fluorescent): 8 A, 120 VAC; 4 A, 208-277 VAC
- Electronic Ballast (LED): 5 A 120 VAC; 2 A 277 VAC
- Load Rating (Motor): 1 HP, 120 VAC; 2 HP, 240 VAC
- DC Loads: 4 A, 12 VDC; 2 A, 28 VDC
- Operating Temperature: –
- Dimensions: 4 1/8 H x 1 3/4 W x 1 13/16 D
- Neutral Not Required
Safety Section
- WARNING: Risk of Fire or Electric Shock
- NOTICE: batteries.
Product Usage Instructions
- Before proceeding with installation, ensure that the battery is removed.
- To factory reset the timer, press and hold the ON/OFF button while using a paper clip or pen to press and release the RESET button. Release the ON/OFF button when “INIT” is displayed on the screen.
- Select the desired language by pressing the ON/OFF button to cycle through the options (ENG – English, FRN – French, etc.). Press the ON/OFF button to confirm.
- Select the time zone by pressing the ON/OFF button to cycle through the options (Alaska, Atlantic, Central, Eastern, Hawaii, Mountain, Newfoundland, Pacific). Press the ON/OFF button to confirm.
- Select the country by pressing the ON/OFF button to cycle through the options (USA, Mexico, Canada). Press the ON/OFF button to confirm.
- Enter the latitude and longitude coordinates by pressing the ON/OFF button to cycle through the digits. Press the ON/OFF button to confirm each digit. Note: No decimal point will be displayed.
- Set the offset for Dusk and Dawn settings (optional) by pressing the ON/OFF button to cycle through the options (0-99 minutes). Press the ON/OFF button to confirm.
- The current time and setup will be displayed. Proceed to program setup.
- To select the desired schedule type, press the MODE button until “PGM” is displayed. Press the ON/OFF button to enter the programming menu.
- Choose between programming template events or programming-specific events.
- If using templates, press the ON/OFF button on the desired template. Press MODE to select AUTO to RAND for random activation.
- If programming specific events, enter the desired ON and OFF times by pressing the ON/OFF button to cycle through the digits. Press the ON/OFF button to confirm each digit.
- Repeat step 11 for additional events.
- Select the days of the week for the events by pressing the ON/OFF button to cycle through the options (ALL, SUN, MON, TUE, WED, THU, FRI, SAT, M-F, WKD). Press the ON/OFF button to confirm.
- Press the MODE button to exit programming mode.
RATINGS
ST01/ST01K | EI600 | |
---|---|---|
Operating Voltage | 120-277 VAC, 50/60 Hz | |
Resistive (heater) | 15 A, 120-277 VAC | 20 A, 120-277 VAC |
Tungsten (incandescent) | 15 A, 120 VAC; 6 A, 208-277 VAC | |
Ballast (fluorescent) | 8 A, 120 VAC; |
4 A, 208-277 VAC
| 16 A, 120-277 VAC
Electronic Ballast (LED)| 5 A 120 VAC; 2 A 277 VAC
Load Rating (Motor)| 1 HP, 120 VAC; 2 HP, 240 VAC
DC Loads| 4 A, 12 VDC; 2 A, 28 VDC
Operating Temperature| 32° F to 104° F (0° C to 40° C)
Dimensions| 4 1⁄8” H x 1 3⁄4” W x 1 13⁄16” D
Neutral Not Required
SAFETY SECTION
Risk of Fire or Electric Shock
- Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing (including replacing the battery).
- Installation and/or wiring must be in accordance with national and local electrical code requirements.
- Use COPPER conductors ONLY.
- Do Not recharge, disassemble, heat above 212° F (100° C), crush, or incinerate the Lithium battery. Keep out of reach of children.
- Replace the battery with Type CR2 only which is certified by Underwriters Laboratories (UL).
- Do NOT use a timer to control devices that could have dangerous consequences due to inaccurate timing, such as: sun lamps, saunas, heaters, slow cookers, etc.
NOTICE
- Follow local electrical codes during installation.
- Risk of timer damage due to leakage if the weak battery is not replaced promptly.
- Dispose of product per local regulations for disposal of Lithium batteries
TIMER INTERFACE
PRODUCT DESCRIPTION
The ST01 and EI600 series timers combine scheduling, and countdown features
into one simple-to-install unit. Features include 7-day programming with
optional Automatic Daylight- Saving Time (DST) adjustment, 40 available event
spaces for building any combination of scheduled events (Dawn, Dusk, or
Specific times), RAND (random) feature used to deter unwanted visitors,
providing an “occupied” look when you’re away, and more. The DOWN (countdown)
function is designed for turning devices Off after activation, ranging from
one second up to 24 hours, and is incandescent, fluorescent, CFL, and LED
compatible. The ST01/EI600 can handle most load types does not require a
neutral wire connection, and supports three languages, English (ENG), Spanish
(SPAN), and French (FRN), making it ideal for many applications
IMPORTANT NOTES
Please read these notes before continuing.
- The timer is battery-powered and does not need AC power for initial setup and programming; it also controls the ON/OFF function (“clicking” sound) and maintains the time and date.
- BATT LOW flashes on display when the battery strength is low.
- When replacing the battery, first disconnect the AC power. Once the old battery is removed, you’ll have a few minutes to insert the new battery before the date and time settings are lost. All other settings will remain in memory, without battery or AC power.
- AUTO (automatic) and RAND (random) modes don’t appear in the menu options until at least one ON or OFF event is programmed.
- All menus “loop” (repeat options at the end of the menu). When in a specific MENU, press ON/OFF to loop within that MENU.
- The + or – buttons change what is flashing on the screen. Hold them down to scroll faster.
- The countdown (DOWN) function allows users to decide between setting a 3-minute shut-off warning WARN (warning) or turning WARN (warning) off.
PRE-INSTALLATION
Before programming, install the supplied battery.
- Gently pry open the access door, located below the ON/OFF button, and remove the battery tray from the timer. (Search for YouTube video for “ST01 Programmable Timer Battery Replacement”)
- Place the supplied CR2 battery into the tray. Make sure to match the + and – markings on the battery to the tray. Install the tray into the timer.
- The product initializes and enters the MAN (manual) MODE of operation with the time blinking at 12:00 am
Note: If the display does not flash at 12:00 am, check/replace the battery before proceeding.
PROGRAMMING
Follow these steps for the initial setup and programming of the ST01 and EI600
series timers.
Factory Reset Timer
- Press and hold ON/OFF (continue holding until step 3)
- Using a paper clip or pen, press and release the RESET button.
- When you see INIT on the display then release the ON/OFF button PRO-TIP: The choice of languages are ENG (English), FRN (French), and SPAN (Spanish)
- Use the + or – to select the desired language
- Press ON/OFF to confirm
- Use + or – to select the timer’s function you want to use STD (Standard) timer operation (on and off times. DOWN (Countdown) timer
- Press ON/OFF to confirm
Next Step
- For Standard Operation (STD): 12:00 am will flash showing
- MAN after Factory Reset; to program, go to “Initial Setup.”
- For Countdown Operation (DOWN), the screen will display OFF; to program, go to “COUNTDOWN OPERATION ONLY.”
STANDARD OPERATION ONLY
Initial Setup
-
Press the MODE button until you see SETUP on the display
-
Press the ON/OFF button to confirm
-
Use the + or – to set the current time of day HOUR (make sure your AM or PM is correct)
-
Press the ON/OFF button to confirm
-
Use the + or – to set the current time of day MINUTE
-
Press the ON/OFF button to confirm
-
Press the + or – to set the current YEAR
-
Press the ON/OFF button to confirm
-
Press + or – to set the current MONTH
-
Press the ON/OFF button to confirm
-
Press + or – to set the current DATE
-
Press the ON/OFF button to confirm
-
Make sure it is showing the correct DAY of WEEK (today)
-
Press the ON/OFF button to confirm
-
Press + or – to select if the timer will adjust for DAYLIGHT SAVING TIME (DST) in spring and fallAUTO means it will adjust automatically
-
OFF means it will not change
-
Press the ON/OFF button to confirm
-
Press the + or – to select your TIMEZONE
-
Alaska (AKT), Atlantic (AT), Central(CT) (default), Eastern (ET), Hawaii (HT), Mountain (MT), Newfoundland (NT), Pacific (PT))
-
Press the ON/OFF button to confirm
-
Press + or – to select your COUNTRY (CTRY)
-
USA (default), Mexico (MEX), Canada (CAN)
-
Press the ON/OFF button to confirm PRO-TIP: Refer to the QR code under warranty information for the latitude and longitude chart.
-
Press + or – button to select your LATITUDE (LAT)
-
Press the ON/OFF button to confirm
-
Press + or – button to select your LONGITUDE (LONG)
-
Press the ON/OFF button to confirm
NOTE: No decimal point will be displayed. For example, LAT 48.0 should be entered as 480 PRO-TIP: You have the option to “Offset” the Dusk and Dawn settings from 0 to 99 minutes. -
Press + or – button to adjust the current DAWN time (you can include an offset here).
-
Press the ON/OFF button to confirm
-
Press + or – button to adjust the current DUSK time (you can include an offset here).
-
Press the ON/OFF button to confirm (You will now see your current time and SETUP) – Proceed to Program Setup
Programming Setup
PRO-TIP: Before Standard Programming Setup, you’ll need to determine which
type of schedule fits your application from the list below:
- T1= Template 1 – On at DUSK. Off at Dawn
- T2= Template 2 – On at DUSK. Off at 10:00 PM
- T3= Template 3 – On at DUSK. Off at 10:00 PM.
- On at 5:00 AM. Off at Dawn.
Specific Time – ON/OFF
- Press the MODE button until you see PGM on the screen.
- Press the ON/OFF button to enter the programming menu.
Advance to “Programming Template Events” or “Programming Specific Events”. Programming Template Events PRO-TIP: Templates are set for all days initially.
- When you first enter the PGM menu press the + or – to select a template.
- Press the ON/OFF button on the template you wish to use
- The last step is to press MODE to select AUTO to RAND (random).
Programming Specific Events
PRO-TIP: You will need a minimum of 2 events (one for ON and one for OFF)
-
When you first enter the PGM menu, press the + or – to advance to event # 01. 2. Press the ON/OFF button to confirm
-
Press the + or – to select if this will be an ON or OFF event
-
Press the ON/OFF button to confirm
-
Press the + or – to select if this will be a DAWN, DUSK or Specific Time event (specific time will have a time flashing)
-
Press the ON/OFF button to confirm
-
For Specific Time: Press + or – to set the hour you want (make sure the AM or PM is correct)
-
Press the ON/OFF button to confirm the hours
-
Press the + or – to set the minutes
-
Press the ON/OFF button to confirm Press + or – button to select what day or group of days you want this event to happen. PRO-TIP: ALL- all seven days of the week Individual Day- select: SUN, MON, TUE, WED, THU, FRI or SAT
M-F- Monday through Friday WKD- Saturday and Sunday -
Press the ON/OFF button to confirm
-
If you need to set another event, Press the + button to advance to the next event and repeat steps starting from step 2.
-
When you’re finished adding events, Press the MODE button to advance to AUTO (automatic) or RAND (Random) MODE.
EDIT, SKIP, DELETE STANDARD EVENTS
- Press MODE until PGM appears on the display.
- Press ON/OFF to confirm.
- Press + or – to select EDIT or ERASE EDIT will let you make changes to the schedule and advance to step #4 ERASE will erase ALL programmed events.
- If you select ERASE, press ON/ OFF to confirm, and advance to PROGRAMMING STANDARD EVENTS to program event(s), or
- Press MODE to go to MAN (Manual).
- Press ON/OFF to confirm
- Press the + button to find the event number you want to it, Skip or Erase (ERAS).
- Press ON/OFF to confirm.
- Press the + button to select one of the options below.
- ON – The timer will turn on at this time.
- OFF – The timer will turn OFF at this time.
- If you selected ON or OFF, please go back to Step #5 under “PROGRAMMING SPECIFIC EVENTS”
- SKIP – This will hide or bypass this event that you might want to use at a later date. The timer will ignore any “skipped” events. This is helpful for unusual programming needs, like vacation settings.
- ERAS (erase) – This will erase the selected event.
- If you selected SKIP or ERASE you can continue to step #5 under “PROGRAMMING SPECIFIC EVENTS” or Press MODE to return to AUTO, RAND (random) or MAN (manual).
COUNTDOWN OPERATION ONLY
Countdown Setup
PRO-TIP: The time will move faster the longer you hold down the button.
- Use the + or – button to set the amount of countdown time you would like.
- Press the ON/OFF button to confirm
- Press and hold the MODE and ON/OFF buttons and hold for 5 seconds. The display will show the WARN (warning) menu.
- Press the + or – to select FLASH or OFF.
- Off — the warning function is turned OFF.
- Flash — when the timer reaches minutes before shut-off, it will flash the controlled lights (or other circuit) for 1 second. A “sunburst” icon will appear on the display
- Press the MODE button to confirm
- Press the + or – to select the desired LOCK option.
- None — no locking function is set.
- Pause — users cannot use the Pause function to suspend the timer countdown.
- Time — users can review but not change the time setting. Users can adjust a running countdown but may not exceed the locked shut-off setting.
- All — both the pause and setting or changing of the timer’s shut-off setting is locked.
- Press the MODE button to confirm, the display will show OFF
Change the Countdown Time
PRO-TIP: If the timer is in LOCK MODE, you may not be able to make any changes
to the set time. To start or stop the countdown, press the ON/OFF button.
To pause the countdown, press the Mode button.
- Press the ON/OFF button until the screen shows OFF
- Press and hold the + or – button to set the amount of countdown time you want.
Countdown Operating Tips
- Checking Timer Setting — Press the + or – button to check the timer setting. The display shows the timer setting for 2 seconds.
- Setting Timer When Locked — To unlock the timer, please see the Countdown Setup section.
- Setting Timer When NOT Locked — When the timer is NOT LOCKED, the user can adjust timer settings but must turn the timer OFF before adjusting
- Pausing a Countdown — When the timer is NOT locked, press the MODE button to pause a countdown in progress.
- Pause bars flash while the count holds steady. Press MODE again to continue the countdown or press the ON/OFF button to power the load OFF.
- Shortening or lengthening a Countdown in progress
- To change the remaining countdown in progress, press and hold the + or – button or the ON/OFF button until the display shows the time setting you want for this cycle only.
- When the timer begins its next cycle, the countdown will return to the programmed setting. When locked you can only increase the amount of time to the maximum time set.
- Using the Remote Switch in a 3-Way — When controlling the timer with the remote switch, toggle the remote switch once to toggle on or off.
INSTALLATION
PRO-TIP: When installing a timer with either a contractor or motor load, a
noise filter is recommended (ET-NF). An example of single-pole and three-way
wiring follows. For other three-way wiring scenarios, go to
wwwintermatic.com. Disconnect the power at the
service panel.
- Remove wall switches, if applicable.
- Strip the existing wire ends to 7/16”.
- Wire the timer into the wall box.
Single-Pole Wiring
A | Black — Connects to the hot (black) wire from the Power Source |
---|---|
B | Blue — Connects to the other wire (black) from the load |
C | Red — This wire is not used in single-switch installations. |
Cap with a twist connector
D| Green — Connects to the supplied ground
Three-Way Wiring
PRO-TIP: The distance between the timer and the remote switch must not exceed
100 feet. The wiring shown below is for a timer replacing a three-way switch
at the line side
A| Black — Connect to the wire removed from the “COMMON” terminal of the
switch being replaced
---|---
B| Blue — Connect to one of the other wires removed from the switch being
replaced. Record the wire color connected to the blue wire for use during
load-side installation
C| Red — Connect to the remaining wire removed from the switch being replaced.
Record the wire color
connected to the red wire for use during load-side
installation
D| Green — Connect to the supplied ground
E| Jumper Wire — At the other three-way switch, install the supplied jumper
wire between wire B and the common terminal
FINALIZING INSTALLATION
- Make sure the provided twist-on wire nuts are secure, then tuck the wires into the timer wall box, leaving room for the timer.
- Using the provided screws, secure the timer to the wall box.
- Cover the timer with the wall plate and secure using the provided screws.
- For three-way wiring, install the remote switch in the wall box.
- Install the wall plate and secure it.
- Reconnect the power at the service panel.
Testing the Timer
Make sure the timer displays MAN (manual) MODE during testing
Single-Pole Wiring Test
To test the timer, press ON/OFF several times. The timer should “click” and
the Controlled light or device (load) should turn ON or OFF.
Three-Way Wiring Test
-
To test the timer, test with the remote switch in each of its two positions.
-
Press ON/OFF several times. The timer should “click” and the controlled light or device (load) should turn ON or OFF.
-
If the timer clicks, but the load does not operate:
- Disconnect the power at the service panel.
- Re-check the wiring and make sure the load is functional.
- Reconnect the power at the service panel.
- Retest.
-
If the timer clicks, the load only operates when the remote switch is in one of its two positions, repeat Step 3, a-d, but interchange the two traveler wires (wires Between the timer and the remote three-way switch) connected to red and blue timer wires
PRO-TIP: Consult a qualified electrician if the switch and timer fail to operate as intended -
When the timer “clicks” and the controlled device turns ON and OFF as programmed, the timer is successfully installed!
TROUBLESHOOTING
Note: For more troubleshooting tips, contact Intermatic Technical Support
at: 815-675-7000.
Observed Problem | Possible Cause | What to Do |
---|
Timer display is blank, and the timer does not “click” when you try to turn it on or off.| • Battery is missing
• Battery has no charge
• Battery was installed incorrectly
| • Install a battery
• Replace the battery
• Make sure the battery is installed correctly.
Timer does not switch ON/OFF but display looks normal| • Timer is not set in AUTO, RAND, or MAN MODE
• Battery is low and needs replaced
| • Press MODE to select the operational MODE you want to use
• Replace battery
---|---|---
Timer resets to 12:00| • Timer is installed in conjunction with a contactor or
motor load.| • Install a noise filter (ET-NF) at source of noise
Timer won’t enter AUTO or RAND mode when “MODE” is pressed| • No schedule is
selected| • Proceed to “Programming Standard Events” section
Timer operates at incorrect times, or skips programmed EVENT times| • The
active schedule has conflicting or incorrect events
• Battery may be weak.
| • Review programed events, revise as necessary.
• Replace battery.
| • Timer is in RAND mode, which varies switching times up to +/- 15 minutes|
• Select “Auto Mode”
Load only operates when: remote (three- way) switch is in one position, or
timer ignores the remote switch.| • The remote switch is wired incorrectly.| •
Recheck the wiring,
especially for the jumper
The timer ignores three-way remote switch even though it is wired correctly, or the load turns off immediately after being turned ON| • The remote switch or timer is wired incorrectly.
• There is an excessive length of wire (greater than 100 feet).
| • Contact a qualified electrician
| • The remote switch is not functioning properly or worn out.|
The battery tray is difficult to replace.| • Battery is not seated in the
tray| • Seat the battery in the tray, then reinstall.
| • The tray is misaligned
| • The contact tabs in tray are bent
TROUBLESHOOTING CONT
The timer operation is sluggish, or not switching ON/ OFF at all.| • Even
though the BATT” message is not displayed, the battery is getting weak.| •
Test battery by pressing the ON/OFF button, there should be a “click” sound on
the timer
---|---|---
| • Replace the battery
Timer shows ON but the light or other controlled device is OFF.| • The light
or controlled device itself may be switched OFF.
• The breaker may be tripped
• Loose wiring connection
| • Make sure the light or controlled device is switched ON
and plugged in.
• Check for a tripped breaker
• Check wiring
The timer waits| • This is intentional to allow you to operate the switch a
second time to restart without powering the load OFF.
1 second to
power OFF after
pressing the ON/
OFF button or
operating the
remote switch
The timer is acting erratically.| • Operating software has become
confused and needs to be reset.
| • Perform a Reset: Follow instructions to “Factory Reset Timer”
The timer setting cannot be changed, or the PAUSE
button does not function.
| • The timer setting or pause functions are locked.| • Reset DOWN (countdown) MODE by proceeding to Step 1, under “Countdown Setup”
LIMITED WARRANTY
Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 300, Libertyville, IL 60048. For additional products or warranty information go to: http://www.Intermatic.com or call 815-675-7000, M-F 8 AM to 4:30 pm Please scan the QR code for the longitude and latitude chart
Please scan the QR code for longitude and latitude chart.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>