HydraProbe SDI-12 Soil Moisture Sensor User Guide
- June 12, 2024
- HydraProbe
Table of Contents
HydraProbe SDI-12 Soil Moisture Sensor User Guide
Introduction
SDI-12 is a specialized communication protocol designed specifically for
environmental sensors.
It’s an ideal choice for remote and low-power applications due to its minimal
power consumption and reliable communication with minimal noise and
interference.
Being a standardized protocol, SDI-12 allows for seamless integration of
sensors and data loggers from different manufacturers into the same system,
which simplifies setup and saves time and resources.
However, if you require longer communication distances, higher data rates, or
need to interact with a wider range of devices, Modbus may be a better choice.
You can learn more about SDI-12 by visiting http://www.sdi-12.org
Older versions of Hydra Probe firmware may have different commands, contact
Stevens Water for more information
Technical Specifications
Power | Requirements | 9 to 16 VDC (12VDC Ideal) |
---|---|---|
Consumption | 1 mA Idle, 25 mA for 2s Active | |
Wiring | Red | + Power Input |
Black | Ground | |
Blue | SDI-12 Data Signal |
How To Use
Using SDI-12 involves setting up a master-slave communication system between
devices.
The master device sends requests to the slave devices to read or write data,
and the slave devices respond with the requested data.
The basic steps to use SDI-12 are below:
-
Set up the physical connection: Connect the SDI-12 device to your data logger or microcontroller using a compatible interface cable.
The cable should have three wires: power (positive and negative) and data. -
Set up the SDI-12 communication parameters: Configure your data logger or microcontroller to communicate with the SDI-12 device.
-
Assign SDI-12 addresses: Assign a unique SDI-12 address to each slave device on the network.
-
Send SDI-12 commands: The commands typically include a command code (e.g., “M” for measurement) and an address (e.g., “0” for the first device on the bus).
The device will respond with the requested data.
Many data loggers have a “transparent mode” to communicate directly with the sensor. -
Interpret the data received from the SDI-12 device: The data may be in a specific format or units depending on the device type.
-
Test: Test the communication between the devices and make any necessary adjustments to the commands or settings.
Addressing
The first character of any command or response on SDI-12 is the sensor
address.
A lowercase ‘a’ is used to represent the address.
Each SDI-12 sensor must have its own unique address.
The default address is “0”.
SDI-12 Command | Response | Description |
---|---|---|
aAb! | b | Change Sensor Address |
a – Sensor Address
b – New Sensor Address
Identification
A request for identification will return the sensor address, part number,
firmware version, sensor version, calibration, and serial number.
SDI-12 Command | Response | Description |
---|---|---|
aI! | a12STEVENSWnnnnnv.vvvcSNxxxxxxxx | Send Identification |
a – Sensor address
12 – SDI-12 protocol version STEVENSW – Manufacturer nnnnn – Part number v.vvv
– Firmware version
c – Calibration xxxxxxxx – Serial number
Measurements
SDI-12 Command | Response | Description |
---|---|---|
aM! | atttn | Request Measurement |
a – Sensor address | Send Measurement Readings The following tables list the values and units: Command| P1| P2| P3| P4| P5| P6| P7|
P8| P9 Pore Water Offset Calibration G – General Accuracy and Ranges Parameter| *Accuracy of soil moisture depends on the soil and is highly variable. Model Numbers 02| Professional, w/25 ft. cable Read User Manual Online (PDF format) >>
ttt – seconds (000 – 999) until the measurement is ready
n – number of data fields (1-9) in the measurement
aD0!| a
F – Soil Moisture
I – Bulk EC (Temp Corrected)
G – Temperature (C)
---|---|---
aD1!| a
H – Temperature (F)
J – Bulk EC
L – Real Dielectric Permittivity
aD2!| a
M – Imaginary Dielectric Permittivity
K – Pore Water EC
O – Dielectric Loss Tangent
aM1!| atttn| Request Measurement
ttt – seconds (000 – 999) until the measurement is ready
n – number of data fields (1-9) in the measurement
aD0!| a
L – Real Dielectric Permittivity
M – Imaginary Dielectric Permittivity
N – Imaginary Dielectric Permittivity (Temperature Corrected)
aD1!| a
O – Dielectric Loss Tangent
P – Diode Temperature
Selector Order
Parameter
Unit
F
Soil Moisture
Water fraction by Volume (wfv)
G
Soil Temperature
Celsius (C)
H
Soil Temperature
Fahrenheit (F)
I
Bulk EC
(Temperature Corrected)
Siemens/Meter (S/m)
J
Bulk EC
Siemens/Meter (S/m)
K
Pore Water EC
Siemens/Meter (S/m)
L
Real Dielectric Permittivity
–
M
Imaginary Dielectric Permittivity
–
N
Imaginary Dielectric Permittivity
(Temperature corrected)
–
O
Dielectric Loss Tangent
–
P
Diode Temperature
Celsius (C)
SDI-12 Measurement Sets
aM! and aC!| F| I| G| H| J| L| M| K| O
aM1! and aC1!| L| M| N| O| P| | | |
SDI-12 Command
Response
Description
aXR_PWOS!
a
Read Pore Water Offset
aXWPWOS
a
Write Pore Water Offset
aXD PWOS!
a+3.4
Reset Pore Water Offset to default 3.4
The following extended command will change the coefficients in one of two
general formulas that translate the real dielectric permittivity to soil
moisture.
In many cases, the Hydra Probe will not need to be recalibrated.
The default General calibration has been heavily reviewed and will provide
reasonable accuracy for most applications.
If you need to change the calibration or if a custom calibration is required,
we recommend referring to the Hydra Probe user manual for more information.
SDI-12 Command
Response
Description
aXR_SOIL!
a<G/O/R/C/K>
Get Current soil type
O – Organic
R – Rockwool
C – Custom 1
K – Custom 2
aXWSOIL
G – General
O –Organic
R – Rock Wool
C – Custom 1
K – Custom 2
aXR_COEFA!| a| Read coefficient A
aXR_COEFB!| a| Read coefficient B
aXR_COEFC!| a
aXR_COEFD!| a
aXR_COEFE!| a
aXR_COEFF!| a
aXR_COEF!| a
aXWCOEFA!| a| Write coefficient A
aXWCOEFB!| a| Write coefficient B
aXWCOEFC
aXWCOEFD
aXWCOEFE
aXWCOEFF
---|---|---
aXD_COEF!| a
---|---
Soil moisture for inorganic mineral soils| *Accuracy: +/- 0.01 WFV for
most soils ( m3,m-3)
+/- <0.03 for fine textured soil (typical)
Range: From Complete Dry to Full Saturation (0% to 100% of saturation)
Bulk EC| Accuracy: +/- 2.0% or 0.02 S/m Whichever is greater
Range: 0 to 1.5 S/m
Temperature| Accuracy: +/- 0.3 °C
Range:** -40 to 75 °C
Inter-Sensor Variability| +/- 0.012 WFV (Typical)
Pore Water EC| Hillforts Equation, depends on soil conditions Version Part # Suffix
04| Professional, w/50 ft. cable
06| Professional, w/100 ft. cable References