KERRA Intro Solo Curved Shower Cubicle Instruction Manual
- June 12, 2024
- KERRA
Table of Contents
KERRA Intro Solo Curved Shower Cubicle
Warning: All elements should be checked before assembly. Do not assemble the product in case any of its elements has been found damaged.
Thank you for purchasing our product. Before you start the assembly, please make familiar with these instructions. Diagrams and figures in these instructions are simplified and contain only the details that are necessary for correct assembly of the product. Current version of the instructions is available at the web page www.kerra.eu/?lang=en.
ATTENTION: Failing to follow the recommendations included in these instructions may be the basis for rejecting a possible claim.
PLACE OF ASSEMBLY
- area occupied by the product
- area that must be left free after mounting of the product
NOTES BEFORE ASSEMBLY
- The compartment, in which the product will be installed should be equipped with efficient and effective ventilation and heating system. The product may not be mounted in rooms, where the temperature could drop down below 5°C, due to possible damages that can be caused by frost penetration.
- The place where the product is to be assembled should have level floor with the same elevation as the other parts of the compartment and vertical even walls. The product is not intended for mounting in wall recesses.
- For assembly of the product, empty space should be left around it, according to the fig. 1 – it is necessary for the proper operation and maintenance of the product.
- Glass elements of the product are made from safety glass. The imperative is to exercise extreme caution during unpacking, handling and assembly of the parts made of glass. Glass panes should not be placed directly on the floor or put against walls. They must not be hit or levered by means of hard tools. Use rubber hammer to put glass panes, sections and seals in place. Damaged glass pane will break down to small fragments.
- All elements should be checked before assembly. Do not assemble the product in case any of its elements has been found damaged.
TOOLS NEEDED
- Smar silikonowy
- Silikon
LIST OF PARTS
Operational element
OPERATIONAL ELEMENTS
PRODUCT ASSEMBLY
- The upper and lower horizontal sections are different. Spacing of the upper section stops is larger than that of the lower section.
Warning: The studs attached to the set are not universal. The studs should be selected according to the wall the product is to be mounted to!
- Clean all surfaces to be sealed before applying silicone! It is recommended to wait 24 hours before the adhesive sets.
- After silicone has bonded, check tightness and remove possible leakages!
SAFETY AND USE THE PRODUCT
NOTES CONCERNING SAFETY, USE AND PROPERTIES OF THE PRODUCT
- For safety reasons, electric appliances must not be used inside the product. Such appliances should be kept beyond the reach of persons using the product.
- Do not leave metal objects inside the product. They could corrode.
- For safety reasons, children should use the product under supervision of adults.
- Repairs should only be carried out by authorized service personnel.
- The product is only intended for non-commercial household purposes.
- The cabin door should not be opened or closed violently. Do not lean against the glass panes.
- Persons under the influence of alcohol or narcotics should not use the product.
- Do not allow contact of the product with water with temperature above 65°C, open flame or glowing objects
- Strictly forbidden is even the slightest contamination with the nail polish or hairspray.
- The product can be only used when it is fastened to the wall.
- Do not use the product when it is damaged.
- In case water jet is directed directly to the sealing areas or their vicinity, it is possible that small amounts of water leak to the outside of the product.
- Product components should not be exposed to long-term UV rays.
- Dimensional tolerance of glass panes: thickness – 0.3 mm; convexity – 1 mm; height/width – 3 mm.
- Tolerances of other dimensions: for dimensions ≤ 1000 mm – ± 5 mm; for dimensions > 1000 mm – ± 10 mm.
- Lifetime of operational elements up to 12 months.
- It is not recommended to use replacement products of other manufacturers. Differences in the parameters can influence correct operation of the product.
MAINTENANCE
- After each use, the product should be thoroughly flushed with clean water and wiped with moistened cloth – prolonged contact of the product surface with personal hygiene products can cause damage of its surface or corrosion of metal elements. Before it completely dries, the door should be left open and good ventilation of the compartment ensured. The cloth used, may not contain scrubbing or scratching fibres.
- Product surface must be cleaned using mild detergents and a soft cloth. After cleaning, the product must be rinsed with plenty of clean water and dried – long contact of the product surface with detergents may cause damage to the surface or corrosion of metal components
- Warning: Before the application of an agent, make sure it will not damage product surface. If the MSDS provided by the manufacturer does not contain sufficient information regarding the use on a particular surface, it is recommended to test the agent on a part that is not readily visible. Do not use aggressive agent, containing caustic (e.g., sodium hydroxide, NaOH), irritating or abrasive substances. These may damage product surface. The cloth used must not contain scouring or abrasive fibres
- To remove limestone deposit and scale, citric acid can be used diluted with water in proportion 1:5.lution Descaled surfaces should be thoroughly flushed with clean water and dried. Prolonged contact with descaling agent can cause damage to its surface or corrosion of metal elements.
- At least once in a month inspection of the operational elements should be carried out and loss of silicone grease on rollers completed. Used-out elements should be replaced.
- If the product is intensively used, or at least 30 hours per month, it is recommended to carry out maintenance activities described in items 4 above more frequently than once in two weeks.
Instructions version : 1.0
Manufacturer
- NOVOTERM Sp. z o.o.
- ul. Zimowa 6, PL 70-807 Szczecin
- www.novoterm.eu