Thank you for purchasing an Aquatic Life T5HO G3 Hybrid Fixture.
When maintained properly, this unit will provide you with years of service.
Your G3 Hybrid fixture allows for the power cords to exit the same side of the
fixture. In addition, the endcaps that conceal the cords can be adjusted for
peninsula tank installations. The power cord uses a C14 type connector, to
easily switch the type of power outlet plug or extend the length of the cord.
The HEP® brand ballasts work with 100-277 V, 50-60 Hz electric and use end-of-
life protection to prevent bad lamps from lighting.
WE TEST EACH FIXTURE BALLAST PRIOR TO SHIPPING THE FIXTURE. IF LAMPS DO NOT
WORK, REFER TO THE TROUBLESHOOTING SECTION.
| WARNING: Please read carefully before proceeding with installation.
Your failure to follow any attached instructions and operating parameters may
lead to the product’s failure.
---|---
A) READ & FOLLOW ALL SAFETY INSTRUCTIONS.
B) DANGER To avoid possible electric shock, special care should be taken
since water is employed in the use of aquarium equipment. For each of the
following situations, do not attempt repairs by yourself; contact Aquatic Life
for assistance
- If the appliance falls into the water, DON’T reach for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately. (Non-immersible equipment only)
- If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. (Immersible equipment only)
- Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet.
- Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner.
- To avoid the possibility of the appliance plug or receptacle getting wet,
position aquarium stand and tank to one side of a wall-mounted receptacle to
preventwater from dripping onto the receptacle or plug. A “drip loop,” should
be arranged by the user for each cord connecting an aquarium appliance toa
receptacle. The “drip loop” is that part of the cord below the level of the
receptacle, or the connector if an extension cord is used, to prevent water
traveling along the cord and coming in contact with the receptacle. If the
plug or receptacle does get wet, DON’T unplug the cord. Disconnect the fuse or
circuit breaker that supplies power to the appliance.
Then, unplug and examine for presence of water in receptacle.
C) Close supervision is necessary when any appliance is used by or near children.
D) To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, etc.
E) Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank the cord to pull the plug from outlet. Grasp the plug and pull to disconnect.
F) Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
G) Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
H) Make sure an appliance mounted on a tank is securely installed before operating it.
I) Read and observe all the important notices on the appliance.
J) If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
K) For added safety, the appliance can be plugged into a receptacle controlled by a GFCI (ground fault interrupter) circuit breaker. The device must be properly connected to a grounded three-prong receptacle. Not all GFCI outlets work with electronic ballasts.
L) This appliance is intended FOR HOUSEHOLD USE ONLY.
M) SAVE THESE INSTRUCTIONS.
FIXTURE ASSEMBLY
Step 1 – Lay the two fixtures upside down on a surface that won’t scratch
the finish.
Power cords should be positioned on the same sides as pictured.
| NOTE: It is important for the reflector side to be facing up for
assembly.
---|---
Step 2 – Attach the two metal endplates to each side of the fixtures
using the four machine screws and nuts.
Repeat on other end of fixture to secure the second Endplate.
Step 3 – Before installing the Endcaps, it is important to route your LED
fixture cords along one or both sides of the fixture endplate.
Step 4 – Install both Endcaps on each end of the fixture. There is a top
and bottom to the Endcaps. The ribbed side is the top, smooth side is the
bottom. Route cords through open end of Endcap.
Step 5 – Install the two long screws through the Endcap corners on the
non-cord side of the fixture.
Step 6 – Remove the reflector protective film and install the T5HO lamps
of your choice into the silicone endcaps. Secure the lamps with the clip at
the end of each lamp.
Step 7 – Turn fixture over and install the LED fixture brackets and then
secure your LED fixture to the brackets. Use the short screws to lock the
brackets in place.
Step 8 – Pull any excess LED cords through the Endcap(s) so there is no
excess cord in themiddle of the Hybrid fixture.
SUSPENSION HARDWARE INSTALLATION
Step 1 – Turn the end of the suspension hardware counter-clockwise to
widen the end and insert into the opening in the center of the fixture. Slide
the suspension hardware toone side of the fixture. Repeat with the other
suspension cable and slide to the opposite side of the fixture.
Step 2 – Turn the suspension top clockwise to lock in place
TROUBLESHOOTING
PROBLEM:
One side of the Hybrid Fixture is not working.
99.9% of the time when one side of the Hybrid fixture is not working, it is a lamp issue. Even new lamps can be prone to not working.
The HEP® brand ballasts used in the Hybrid fixtures include an end-of-life protection feature. This means if one of the lamps isn’t firing properly, it will stop the ballast from working.
This feature prevents the lamp from overheating and possibly causing a fir
LAMP TEST:
Unplug the power cord from the power outlet. Now plug the fixture back into a
live power outlet.
DO THE LIGHTS FLASH ON AND THEN GO OFF?
IF YES, you have one or two bad lamps and need to replace your lamps.
FOLLOW THESE STEPS IF ONE FIXTURE IS NOT WORKING:
- Unplug both sides of the Hybrid fixture and turn it over so you can see the lamps.
- Number the silver ends of the lamps with a permanent marker (1, 2, 3, 4).
- Plug in both sides of the Hybrid fixture and note which number lamps are not working.
- Unplug the two fixtures swap the lamps between the working side with the nonworking side. Make sure to move them as a pair.
| NOTE: It is important to unplug the fixture to reset the end-of-life protection in the ballast.
---|--- - Plug in the fixture that was not working.
It should now be working.
The ballasts used in the Hybrid fixture are a “Series” type, meaning that if
one lamp is bad, both lamps will not work in the fixture.
You can now try different combinations of the numbered (1, 2, 3, 4) lamps to
determine which lamp(s) is bad
All HEP ballasts are tested in every fixture prior to boxing and shipping.
If you need additional support, please contact Customer Service at
customersupport@aquaticlife.com
UNIT MAINTENANCE
Turn off the power to the T5HO Fixture and LED Fixtures and unplug the fixtures. Wipe the housing with a clean moist/semi dry cloth to remove dust, salt and other debris that may build-up on the fixture.
PRODUCT REGISTRATION
Register Online at www.aquaticlife.com
Lifetime Products is committed to reducing our carbon footprint and we
appreciate your time in registering electronically.
PRODUCT ASSISTANCE
Contact Aquatic Life at CustomerSupport@aquaticlife.com
LIMITED WARRANTY
Aquatic Life warrants that this product (excluding lamps) shall be free from defective electrical components and leaks or cracks due to defects in materials or workmanship for a period of twelve (12) months from the date of purchase. If a defect is shown, Aquatic Life will, at Aquatic Life’s sole discretion, either repair or replace the product without charge. No cash refunds will be made. This warranty is provided solely to the original consumer purchaser of the product and may not be transferred or assigned.
This warranty does not apply to damage resulting from accident, misuse, abuse, lack of reasonable care, failure to follow safety and installation instructions, use of the product with non-standard electrical service, or any other defect not resulting from defects in the electrical components of the product or defects in materials or workmanship. This warranty will not be effective unless and until the Aquatic Life product is shown to have been used in accordance with the safety and installation instructions accompanying the product.
THIS CONSTITUTES AQUATIC LIFE’S ENTIRE WARRANTY AND AQUATIC LIFE MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. AQUATIC LIFE, LLC SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF AQUATIC LIFE, LLC CANNOT LAW FULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. AQUATIC LIFE IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY. AQUATIC LIFE EXPRESSLY DISCLAIMS ALL ALLEGED DAMAGES FOR LOSS OF MARINE LIFE, PERSONAL INJURY, AND/OR PROPERTY DAMAGE.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of implied warranties or conditions, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary by state or province.
Aquatic Life shall not have any obligations under this warranty unless the owner notifies Aquatic Life in writing of any alleged defect(s) within 30 days of discovery of the defect(s).Any notice to Aquatic Life must be delivered by United States or electronic mail to the following address:
Aquatic Life
9710 Klingerman St. | S El Monte, CA | 91733
Email:customersupport@aquaticlife.com