PUR SPAS Converting 120V Hot Tube to 240V Instructions

June 12, 2024
PUR SPAS

PUR SPAS Converting 120V Hot Tube to 240V

PUR SPAS Converting 120V Hot Tube to 240V product

Product Information

The product being discussed is a hot tub manufactured by Gecko Equipment. This user manual provides instructions for converting a 120V hot tub to 240V. It is important to note that this guide is intended for certified electricians only. The manual emphasizes the need for professional expertise and strongly advises against attempting the conversion without proper certification.

Gecko Electrical Box Diagram (Annex 1)

The electronic box of the hot tub is located under the keyboard, behind the side panel. To perform the conversion, follow these steps:

  1. Open the electric box.
  2. Locate the terminal at the main power input.
  3. Disconnect the cable at positions N, L1, and G from the 120V.
  4. Remove the brown wire at position L2 from the terminal at the main power input.
  5. Connect the necessary cables to the 240V. Refer to the diagram in Annex 1 and information on wire in Annex 2.
  6. Close the electronic box, seal the Thermo foil, and close the side panel.

Hot Tub Usage Instructions

To complete the conversion and activate the hot tub, follow these steps:

  1. Open the hot tub.
  2. On the keypad, press the light button for 30 seconds or until the code “b” appears.
  3. Using the up arrow, navigate to number 32 so that “b32” is displayed on the keyboard.
  4. Press the light button one last time to confirm.

It is emphasized that users should also consult the user’s manual that came with the hot tub for additional useful information.

Important Electrical Information

When operating the hot tub on 240V, it is crucial to use a 40 amp GFCI breaker. For 120V use, a GFCI directly into the wire is provided and must only be plugged into a dedicated 15 amp hot tub outlet.
For the conversion to 220V, the user must connect the spa to a 220V 40A (minimum) GFCI breaker and the home electrical panel. The appropriate wire size depends on the distance between the spa and the wall outlet:

  • If the spa is more than 50′ from the wall outlet: use a grounded 6 AWG/3 wire.
  • If the spa is located within 50′ from the wall outlet: use a grounded 8 AWG/3 wire.

It is strongly recommended to hire a certified electrician to install the GFCI breaker and connect the spa to the house electrical panel. If the spa only operates on a 220V electrical circuit, no conversion is needed for the spa pack. However, if the spa is convertible from 110V to 220V, instructions for the conversion can be found inside the spa pack cover. If there are any questions or concerns, users may contact the service department at info@purspas.com.

IMPORTANT
This guide is intended for certified electricians only. It is strongly not recommended to do the conversion if you are not a certified electrician. to do the conversion if you are not a certified electrician.

  1.  The electronic box is located under the keyboard, behind the side panel;

  2. Open the electric box;

  3. Locate the terminal at the main power input.

    • Disconnect the cable at positions N, L1 and G from the 120 V;

    • Remove the brown wire at position L2 from the terminal at the main power input;

    • Connect the necessary cables to the 240V. See diagram in Annex 1 and information on wire in Annex 2;

  4. Close the electronic box, seal the Thermo foil and close the side panel;

  5. Open the hot tub;

  6. On the keypad, press the “light” button for 30 seconds or until the code “b” appears;

  7. With the up arrow, click until number 32 so you have b32 on the keyboard:
    PUR SPAS Converting 120V Hot Tube to 240V 06

  8. Press the “light” button one last time to confirm.

IMPORTANT
You must use a 40 amp GFCI when on 240V. For 120V use, a GFCI directly into the wire is provided and must only be plugged into a dedicated 15 amp hot tub outlet.

DON’T HESITATE
TO READ THE USER’S MANUAL THAT CAME WITH THE HOT TUB. LOTS OF USEFUL INFORMATION IS INCLUDED.

INFORMATION ON WIRE

ANNEX 2
If you plan to operate your spa using a 220V electrical supply, you will be required to install a 220V 40A (minimum) GFCI breaker. You have to connect your spa to this GFCI breaker and your home electrical panel.

WHICH WIRE TO USE?

  1.  If the spa is more than 50’ from the wall outlet: a grounded 6 AWG/3 wire
  2.  If the spa is located within 50’ from the wall outlet: a grounded 8 AWG/3 wire

Don’t forget, we recommend using a certified electrician to install your GFCI breaker and to connect your spa to your house electrical panel. If your spa only runs on a 220V electrical circuit, no conversion is needed for the spa pack.
If your spa is convertible from 110V to 220V, you will find instructions to convert the spa pack on the inside of the spa pack cover.PUR SPAS Converting
120V Hot Tube to 240V 09Having any questions? You may contact our service department info@purspas.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals