SolarV GmbH 4924100 25.6V 100AH LiFePO4 Battery Instruction Manual

June 12, 2024
SolarV GmbH

SolarV GmbH 4924100 25.6V 100AH LiFePO4 Battery

LiFePO4 Battery 25.6V 100Ah

Dimension (mm)

SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-1

SolarV® Lithium iron phosphate (LiFePO4 or LFP) batteries are considered to be more environmentally friendly energy storage than traditional lead-acid batteries, and they comply with the European RoHS regulations. Lithium storage batteries boast excellent safety, reliability, and high efficiency. The high number of cycles ensures a long lifespan and up to 80% usable capacity without deep discharge. The integrated BMS in our LiFePO4 battery ensures a high level of protection functions to safeguard against overvoltage and overcharging. The SolarV® LiFePO4 batteries offer a proven advantage with their unparalleled energy storage-to-weight ratio – a weight savings of over 60% compared to AGM/Gel batteries. With the newly integrated Bluetooth communication feature, it enables operational monitoring through our Smart App for iOS and Android devices. Recommended applications include campervans, boats, PV systems, recreational applications, and uninterruptible power supplies (UPS).

Special features

  • High energy density with low weight – 60% lighter than AGM/gel batteries
  • Absolutely maintenance-free operation
  • Integrated Bluetooth for connectivity – operational monitoring at any moment. (Max distance 30m)
  • Integrated BMS with numerous protection features
  • Up to 80% usable capacity without deep discharge
  • Up to 3 times as many cycles as conventional lead-acid batteries
  • Self-discharge < 5% per month
  • Product Warranty: 2 years

Technical Specifificatitions

Electrical Parameters

Nominal Voltage 25.6V
Rated Capacity 100Ah
Energy 2560 Wh
Resistance ≤35m Ω
Efficiency ≥0.98
Cycle Life1C,80%DOD,25 ℃) >2000 cycles @1C, 80% DOD
Self Discharge <5% per Month
Max.Cell in Series/Parallel 8S/ 1P

Discharge Parameters

Continuous Discharge Current 100A
Pulse Discharge Current 110A(<10S)
Recommended Volt. Disconnect 20V

BMS Discharge Cut-off

Voltage

| 20V
Reconnect Voltage| 24V
Short Circuit Protection| 300-800us

Temperature Parameters

Discharge Temperature -20℃ to 60℃
Charge Temperature 0℃ to 55℃
Storage Temperature -20℃ to 60℃
BMS High-Temperature Cut- off 65℃

Mechanical Parameters


Dimension(L×W×H)

| 480x170x240mm
---|---
18.90x 6.69x 9.45″
Weight| 19.5 kg
Terminal Type| M8
**| ABS
Housing Protection| IP65
Cell Type-Chemistry**| LiFePO₄ Cell
 | Bluetooth

Charge Parameters

Charge Method CC-CV
Charge Voltage 28.4~29.2V
Recommended Float Voltage 27~27.6V
Recommended Charge Current 50A
Maximum Charge Curren 100A
BMS Charge Cut-off Voltage 30V

Technical Diagrams

SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-2 SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-
FIG-3

APP-Download

Please scan the QR code or click the link to download SolarV LFP App

SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-4

Operation manual

  1. Click on the App iconSolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-5
  2. Click „ADD NEW BATTERY”SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-6
  3. Turn on BluetoothSolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-7
  4. Search for your battery. If it does not appear in the list, click on ”Refresh“SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-8
  5. Click on the Bluetooth name that is written on the battery. You will now be taken to the home page of the appSolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-9
  6. Swipe the page to the left to display the basic information, protection status and protection statisticsSolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-10 SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-11
  7. Click on the data behind the nominal capacity, enter the correct capacity in the pop-up field, and click on,, confirm” to complete the modification.

SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-12

Troubleshooting

error display troubleshooting

Cell fully charged on Stop charging or discharge
Cell under voltage on Charge the battery
Battery fully charged on Stop charging or discharge
Battery under voltage on Charge the battery
Charging high temperatures on Stop charging and move the battery to a

shady area; the battery will automatically return to normal


Charging low temperature on

| Stop charging and move the battery to a warmer (room) temperature environment; the battery will automatically return to normal
Discharging high temperatures on| Stop discharging and move the battery to a shady area; the battery will automatically return to normal
Discharging low temperatures on| Stop discharging and move the battery to a warmer (room) temperature environment; the battery will automatically return to normal
Charging over current on| Stop charging and check the charger output current.
Discharging over current on| Stop discharging and make sure the load current is not within the battery’s maximum discharge current range
Short circuit on| Fix the short circuit error. If the error cannot be cleared automatical- ly, charge the battery to clear the error. If this is not possible, send the battery to the workshop for repair
Front-end detection IC error| Depot repair
Charging timeout shutdown| Depot repair

SolarV GmbH

SolarV-GmbH-4924100-25-6V-100AH-LiFePO4-Battery-FIG-13

Copyright© 2022 SolarV GmbH All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals