Hopeland HZ340 Smart 340 IoT RFID Reader User Manual
- June 12, 2024
- Hopeland
Table of Contents
- Hopeland HZ340 Smart 340 IoT RFID Reader
- Product Information: HZ340/380 Smart 340/380
- Technical Specifications
- Product Usage Instructions
- Specifications
- Sketch map
- Installation Instructions
- Common Failures
- Packaging Accessories and Storage
- After-sale Service
- Warranty Description
- FCC warning
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hopeland HZ340 Smart 340 IoT RFID Reader
Product Information: HZ340/380 Smart 340/380
The HZ340/380 Smart 340/380 is a cost-effective fixed UHF RFID reader that supports ISO18000-6C/6B protocols. It has four/eight ports and supports China standard dual frequency 920MHz~ 925MHz and 840MHz – 845MHz, FCC 902MHz ~ 928MHz and ETSI 865MHz ~ 868MHz frequencies. It has an optional output power of 0 ~ 30dBm, high recognition sensitivity, fast speed, strong anti- interference ability, high multi-antenna recognition efficiency, and structure anti-collision and shock resistance.
Technical Specifications
Features
- Support protocol: ISO18000-6B/C EPC C1G2
- Rich communication interfaces: RJ-45, RS232
- Support tag data filtering
- RSSI support: the strength of the signal can be sensed
- Adjustable RF output power
- Working mode: fixed frequency/frequency hopping optional
- Support antenna detection function
- Support online upgrade
- I/O interface: 2 optocoupler inputs, 2 relay outputs (drive capacity: DC 30V/ 2A, AC 125V/0.3A)
Main Functions and Technical Performance
-
Working frequency: GB:920MHz~925MHz,840MHz~845MHz,
FCC:902MHz~928MHz , ETS:865MHz~868MHz (depending on tag type and application environment) -
Channel occupied bandwidth:
Product Usage Instructions
- Connect the HZ340/380 Smart 340/380 to a power source and turn it on.
- Connect the RFID reader to your computer or network using either the RJ-45 or RS232 communication interface.
- Adjust the RF output power as needed.
- Select the working mode as either fixed frequency or frequency hopping.
- Configure tag data filtering and RSSI support as needed.
- Ensure that the antenna detection function is enabled.
- Use the optocoupler inputs and relay outputs as needed.
- Upgrade the firmware as needed using the online upgrade feature.
Specifications
Features
Smart HZ340/380 is a cost-effective four-port/eight-port fixed UHF RFID
reader, it supports ISO18000-6C/6B protocols. The work frequency includes
China standard dual frequency 920MHz~ 925MHz and 840MHz – 845MHz, FCC 902MHz ~
928MHz and ETSI 865MHz ~ 868MHz.
Output power from 0 ~ 30dBm optional, it has the characteristics of high
recognition sensitivity, fast speed, strong anti-interference ability, high
multi-antenna recognition efficiency, and structure anti-collision and shock
resistance.
Main Functions and Technical Performance
Product Features
- Support protocol: ISO18000-6B/C EPC C1G2
- Rich communication interfaces: RJ-45, RS232
- Support tag data filtering
- RSSI support: the strength of the signal can be sensed.
- Adjustable RF output power
- Working mode: fixed frequency/frequency hopping optional
- Support antenna detection function
- Support online upgrade
- I/O interface: 2 optocoupler inputs, 2 relay outputs (drive capacity: DC 30V/ 2A, AC 125V/0.3A)
Performance Parameters
- Working frequency: GB:920MHz~925MHz,840MHz~845MHz, FCC:902MHz~928MHz , ETS:865MHz~868MHz
- RF output power (port): 30dBm±1 (MAX)
- Output power adjustment: 1 dB step
- Reading distance: 0m~8m (related to factors such as transmitting power, antenna type, tag type and application environment)
- Channel occupied bandwidth: <200KHz
- RS232 interface communication rate: 115200bps(default),19200 bps,9600bps
- AC-DC power adapter: AC input 100V~240V,50Hz~60Hz DC output 24V/2.5A
Environmental Parameters
- Working temperature: -20℃~+70℃
- Working humidity: 5%~90%RH (+25℃)
Sketch map
Physical construction
Smart 340/380 Reader Volume Parameter is:
- 170mm×120mm×25mm
Net Weight
- 1 Kg
Interface Diagram
Power, Communication and I/O Interfaces
Figure 2-2 is a schematic diagram of the reader and the power supply, communication and I/O interface panel. For details, see Table 2-1.
Table 2-1 Reader power supply, communication and I/O interfaces
Interface ID | Interface Name | Detailed Description |
---|
DC24V IN
| Power supply
interface
|
DC, 10~30V, power capacity not less than 20W.
LAN
|
Ethernet interface
| 10/100M Ethernet interface, reader control and
communication interface.
RS232| RS232| Serial port, reader control and communication interface.
I/O Port| I/O interfaces| See 2.3.2 for detailed definition
I/O Interface Definition
I/O control signal definitions are shown in Table 2-2:
Table 2-2 I/O control interface signal function definition
Pin ID | Pin Description |
---|---|
R1 | Relay 1# output; DC_MAX: 30V, 2A; AC_MAX: 125V, 0.3A; logic ‘0’ indicates |
open circuit,
logic ‘1’ indicates closed, default is open circuit.
L1| Relay 1# output; DC_MAX: 30V, 2A; AC_MAX: 125V, 0.3A; logic ‘0’ indicates open circuit,
logic ‘1’ indicates closed, default is open circuit.
R2| Relay 2# output; DC_MAX: 30V, 2A; AC_MAX: 125V, 0.3A; logic ‘0’ indicates open circuit,
logic ‘1’ indicates closed, default is open circuit.
L2| Relay 2# output; DC_MAX: 30V, 2A; AC_MAX: 125V, 0.3A; logic ‘0’ indicates open circuit,
logic ‘1’ indicates closed, default is open circuit.
IN1| Optocoupler 1# input, DC, 0~24V, higher than 1V is high level, lower than
1V is low level
IN2| Optocoupler 2# input, DC, 0~24V, higher than 1V is high level, lower than
1V is low level
GND| Ground
GND| Ground
GPI Usage Example:
Infrared sensor type selection: Choose PNP NO type, which means that the
infrared is normally low, when the object is detected, the signal line outputs
a positive voltage signal.
GPO
Usage Example:
Relay type GPO: GPO is equivalent to a switch, logic ‘0’ means open circuit,
logic ‘1’ means closed, default is open circuit state. You can connect the
alarm light, buzzer, etc. to the GPO for use. The usage is shown in the
following figure.
Coaxial RF Feeder Cable (optional)
RF cable should use SMA (internal thread, internal needle) connector, the
maximum cable length is not more than 5m, impedance is 50Ω, and the insertion
loss is less than 2dB. You can also choose a high-performance cable, increase
the length appropriately, and try to reduce the insertion loss as much as
possible.
Note: The long RF cable or poor contact of the cable connector will cause
excessive attenuation of the transmitted signal and the received echo signal
and deteriorate the reading / writing performance.
Network Connection Diagram
The network interface is used for long-distance high-speed connection (not
greater than 80 m). It can be connected to a switch or router via a network
cable or it can be directly connected to a PC network interface. The specific
connection is shown in Figure 2-5:
Installation Instructions
Precautions
To ensure the normal and stable operation of the device and your personal
property and safety, please carefully read the following notes before install
HZ340/380 reader.
- Firstly, check whether the power socket is connected to the ground, and to see whether the local power supply voltage is in accordance with the applicable voltage range of the reader;
- Check the device and the external connection if is closely connected;
- Pay attention to the type selection and the length limit of the network cable and the serial cable:
- Network cable connects directly, no longer than 80 meters
- Serial cable connects directly, no longer than 10 meters
- When installing several readers, the antenna position and the antenna spacing should be appropriate to avoid interference with each other.
Installation Conditions
Before installing the reader, please check carefully whether the product is in
good condition and the accessories are complete. If there are any parts
missing or damage, please contact the supplier in time.
Device Connection
Connect Power Adapter
- Plug the power cord into the AC power supply outlet and then plug the other end of the power cord into the power connector of the reader and fasten it.
- Power on the reader, wait for about 10 seconds, and the system completes the initialization process and enters the standby state.
Connect External Antenna and RF Cable
The reader built with four/eight SMA coaxial cable connectors for connecting
external antennas, select low consumption RF cable, connectors should be
tightened (Ensure to be waterproof when install outdoors);
The reader antenna angle or tilt need to adjust to the best position through
the actual test according to the specific application.
Connect to PC
- The reader is supplied with different dedicated connection cables for the network, USB and power interfaces.
- The RS232 interface is used for short-distance communication (not greater than 10m). It can be connected to the PC serial port through the DB9 connector to realize the communication between the PC and the reader.
- The RJ45 network port is used for long-distance communication (not greater than 80m), and an extended network cable can be used to connect to a PC.
Install Reader
The reading and writing range of the reader depends on the on-site
application, the tilt angle of the antenna is adjusted to achieve the best
reading and writing performance.
Acceptance
The acceptance criteria are mainly given from two aspects: structure and
performance.
Structural Acceptance
- Whether the reader is fixed firmly without looseness;
- Whether the cables are connected firmly;
- Whether the screws are tightened.
Performance Acceptance
- Whether the reader is working normally;
- Whether the reading range is reasonable.
Common Failures
Daily Maintenance
Daily maintenance of Smart 340/380 reader during use:
- Check whether the RF connector is tightened
- Check whether the screws fixing the reader and antenna are loose
- Check whether the outer shielding layer is disconnected at the RF cable connector
- Check whether the power cord of the reader is connected firmly
Common Failure Analysis and Solution
-
Power supply system failure::
Check whether the power supply of the power adapter is normal and whether the AC power supply voltage is between 100V and 240V -
After power on, the panel indicator does not light up::
Confirm whether the communication is normal, if not, please contact after- sales service. -
The serial port cannot be connected:
The serial port cable is not connected or not firmly connected Whether the serial port connection baud rate of the reader is correct Is the selected COM port correct? -
The network port cannot be connected:
The default IP address of the Smart 340/380 reader is set at the factory: 192.168.1.116. Make sure that the IP address of the PC and the IP address of the reader are in the same network segment, such as “192.168.1.XXX”. Connect with the reader, if you forget the IP address of the reader, you can reset the IP address of the reader through the serial port connection or pressing reset button for 10 seconds. -
The reader cannot read tags
-
Check if the antenna number is set correctly
-
Check if the tag is damaged
-
Check whether the tag placement position is within the effective reading and writing range of the reader
Check whether there is electromagnetic interference between readers or other devices
For problems that users cannot solve by themselves, please contact after-sales service.
Packaging Accessories and Storage
Package
Carton box size: 252mm271.5mm53.5mm (inner size)
Accessories
In order to facilitate future storage and transportation, after unpacking the
Shine 340/380 reader, properly store the box and packaging materials. In
addition to the reader, the box also includes the accessories required for the
use of the product. Please confirm whether the product and accessories are
complete according to the product packing list. If there is any discrepancy or
damage, please contact the after-sales service in time. The specific packing
list is shown in Table 5-1:
Table 5-1 Packing list
No | Name | Unit | Quantity | Remarks |
---|---|---|---|---|
1 | Smart 340/380 reader | 1 | Set | Included |
2 | Power adapter 24V/2.5A | 1 | Pcs | Included |
3 | AC power cord | 1 | Pcs | Included |
4 | LAN Cable | 1 | Pcs | Included |
5 | Mounting screws M4*8 + Foot padΦ4 | 4 | Set | Included |
6 | 8P GPIO connector | 1 | Pcs | Included |
7 | fixed bracket | 1 | Pcs | Included |
8 | warranty card | 1 | Pcs | Included |
9 | Certificate of approval | 1 | Pcs | Included |
Storage Requirements
Smart 340/380 reader should be stored in below conditions:
- Environmental temperature: -40℃~ +85℃
- Relative humidity: 5% RH ~ 90%RH
After-sale Service
Letter to Customers
Since our aim is to continuously improve our products for better user
experience, we may modify the product characteristics, composition and design
of circuits without given notifications. Thus the real product may be not in
accordance with this manual. Generally, we will provide timely amendments to
this manual. If it’s not provided timely, please consult our service
department.
Shenzhen Hopeland Technologies Co., Ltd.
Guarantee card of Shenzhen Hopeland Technologies Co., Ltd
Product Name| | Model No.|
---|---|---|---
Product Code| | Level|
Description of troubles|
User’s name| | Postcode|
Contact Person| | Contact No.|
Warranty Description
In order to offer users better service, our company provide warranty card with each device, please keep it to enjoy the service.
- Products can replace free under conditions within one month after sale, in the precondition of normal operation without repairing.
- Free maintenance won’t be given under the following circumstance:
- The damage of the terminal caused by high voltage of the power grid.
- The damage caused by misuse or operated improperly.
- The damage caused by excessive vibration when user delivering.
- The software of this product can be upgraded freely, users can be training in our company for free.
- Will be charge appropriately if the user doesn’t have a warranty card.
- Users will need to fill out the warranty card for repair service, and sent back to Hopeland.
FCC warning
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with RF radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
Read User Manual Online (PDF format)