hansgrohe 27075000HG Ecostat Shower Combination Instruction Manual
- June 12, 2024
- hansgrohe
Table of Contents
- hansgrohe 27075000HG Ecostat Shower Combination
- Safety Notes
- Installation Instructions
- Technical Data
- Symbol description
- Safety Function
- Adjustment
- ECOSTOP
- Maintenance
- Operation
- Dimensions
- Spare parts
- Test certificate
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
hansgrohe 27075000HG Ecostat Shower Combination
MODELS
Safety Notes
- Gloves should be worn during installation to prevent crushing and cutting injuries.
- The shower system may only be used for bathing, hygienic and body cleansing purposes.
- Children as well as adults with physical, mental and/or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
- The hot and cold supplies must be of equal pressures.
Installation Instructions
The fitting must be installed, flushed and tested after the valid norms!
Thermostatic mixer in conjunction with combination boilers
- If fitting a hand shower remove the water limiter from the shower.
- If the continuous water heater causes any problems, or you have different water pressures you must install a water limiter to the cold supply, (ordered separately,article number 97510000).
- Thermostatic mixer Shower: When using the Ecostat with combination boilers, the Ecostop safety set 95042000 has to be removed.
Technical Data
- Operating pressure: max. 1 MPa
- Recommended operating pressure : 0,1 – 0,5MPa
- Test pressure : 1,6MPa (1 MPa = 10 bar = 147 PSI)
- Hot water temperature: max. 80°C
- Recommended hot water temp.: 65°C
Symbol description
Do not use silicone containing acetic acid!
Safety Function
The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
ECOSTOP
Maintenance
Operation
open
hot
cold
close
open
hot
cold
close
Dimensions
Flow diagram
- Shower
- Bath tub
Spare parts
Test certificate
TROUBLESHOOTING
Fault
- Insufficient water
- Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed
- Spout temperature does not correspond with temperature set
- Temperature regulation not possible
- Shower or spout dripping
- Instantaneous heater didn’t work with thermostat
Cause
- Supply pressure inadequate
- Filters are dirty (96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat, shut-off unit damaged
- Ecostop ring not removed.
- Flow limiter in handshower isn’t removed
- Filters are dirty
- Non return valve hasn’t moved back
Remedy
- Check water pressure (If a pump has been installed check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-thermo cartridge (96922000)
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 °C to 65 °C
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Remove ecostop ring (95042000)
- Remove flow limiter
- Clean the filter exchange filter
- Exchange non return valves
Hansgrohe · Postfach 1145 · D-77761 Schiltach
- Telefon +49 (0) 78 36/51-1282
- Telefax +49 (0) 7836/511440
- E-Mail : info@hansgrohe.com
- Internet : www.hansgrohe.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>